Anca Maria Nagy-Kiss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anca Maria Nagy-Kiss has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- José Ragot
Université de Lorraine, CRAN, UMR 7039, 2 avenue de la forêt de Haye, Vandoeuvre-lès-Nancy Cedex, 54516, France
12 shared publications - Benoit Marx
Université de Lorraine, CRAN, UMR7039, 2 avenue de la Forêt de Haye, Vandoeuvre-lès-Nancy Cedex, 54516, France
10 shared publications Georges Schutz
Luxembourg Institute of Science and Technology
9 shared publicationsGilles Mourot
CRAN
9 shared publicationsG. Schutz
3 shared publicationsG. Mourot
Nancy universite
2 shared publications
Latest Publications
- 30 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Analyse et synthèse de multimodèles pour le diagnostic : application à une station d’épuration
Cette thèse traite de l’analyse et de la synthèse de multimodèles pour la simplification de modèles, l’estimation d’état et le diagnostic des systèmes non linéaires caractérisés par une ou plusieurs échelles de temps. Ces travaux visent, dans un premier temps, à développer une procédure systématique de transformation d’un système non-linéaire en le récrivant sous une forme multimodèle, en évitant quelques inconvénients majeurs : la transformation est réalisée sans perte d’information, le choix de différents points de fonctionnement n’est plus nécessaire, le choix de variables de prémisse est réalisé d’une façon systématique. De plus, la méthode offre le choix entre différents multimodèles. Ce degré de liberté sera utilisé pour faciliter les études de contrôlabilité, d’observabilité et d’analyse de stabilité. Dans un deuxième temps, l’obtention de la forme à perturbations singulières d’un système non linéaire est proposée, en éliminant quelques contraintes structurelles et en rendant l’identification et la séparation des échelles de temps indépendante de la structure du modèle. Dans un troisième temps, la synthèse de plusieurs observateurs robustes vis-à-vis des perturbations, des erreurs de modélisation et des entrées inconnues a été réalisée afin dereconstruire l’état et l’entrée inconnue du système. La difficulté de cette étude provient du fait que le multimodèle utilisé dépend de variables de prémisse non mesurables, situation qui n’est pas intensivement étudiée, alors qu’elle est naturellement issue de l’approche par transformation système non linéaire!multimodèle. Ensuite, le diagnostic de défauts de systèmes est réalisé au moyen de bancs d’observateur à entrées inconnues permettant la génération et la structuration de résidus indicateurs de défauts. Finalement, tous les travaux proposés sont appliqués au modèle d’une station d’´epuration, Activated Sludge Model No.1, qui est largement utilisé dans le domaine du traitement des eaux usées
- 30 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Analyse et synthèse de multimodèles pour le diagnostic : application à une station d’épuration
Cette thèse traite de l’analyse et de la synthèse de multimodèles pour la simplification de modèles, l’estimation d’état et le diagnostic des systèmes non linéaires caractérisés par une ou plusieurs échelles de temps. Ces travaux visent, dans un premier temps, à développer une procédure systématique de transformation d’un système non-linéaire en le récrivant sous une forme multimodèle, en évitant quelques inconvénients majeurs : la transformation est réalisée sans perte d’information, le choix de différents points de fonctionnement n’est plus nécessaire, le choix de variables de prémisse est réalisé d’une façon systématique. De plus, la méthode offre le choix entre différents multimodèles. Ce degré de liberté sera utilisé pour faciliter les études de contrôlabilité, d’observabilité et d’analyse de stabilité. Dans un deuxième temps, l’obtention de la forme à perturbations singulières d’un système non linéaire est proposée, en éliminant quelques contraintes structurelles et en rendant l’identification et la séparation des échelles de temps indépendante de la structure du modèle. Dans un troisième temps, la synthèse de plusieurs observateurs robustes vis-à-vis des perturbations, des erreurs de modélisation et des entrées inconnues a été réalisée afin dereconstruire l’état et l’entrée inconnue du système. La difficulté de cette étude provient du fait que le multimodèle utilisé dépend de variables de prémisse non mesurables, situation qui n’est pas intensivement étudiée, alors qu’elle est naturellement issue de l’approche par transformation système non linéaire!multimodèle. Ensuite, le diagnostic de défauts de systèmes est réalisé au moyen de bancs d’observateur à entrées inconnues permettant la génération et la structuration de résidus indicateurs de défauts. Finalement, tous les travaux proposés sont appliqués au modèle d’une station d’´epuration, Activated Sludge Model No.1, qui est largement utilisé dans le domaine du traitement des eaux usées
- 22 December 2016
- Published by Springer Nature
- p. 159-187
Reducing Complexity of Nonlinear Dynamic Systems
- 22 December 2016
- Published by Springer Nature
- p. 159-187
Reducing Complexity of Nonlinear Dynamic Systems
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1274-1280
State, unknown input and uncertainty estimation for nonlinear systems using a Takagi-Sugeno model
The paper addresses a systematic procedure to deal with the state, unknown input and parameter uncertainty estimation for nonlinear time-varying systems. This is realized by designing a robust observer for dynamic nonlinear systems using a Takagi-Sugeno (T-S) multi-model (MM) approach with nonlinear outputs. The method applies the technique of descriptor systems by considering unknown inputs and parameter uncertainty as auxiliary state variables. This approach allows to apply the tools of the linear automatic to dynamic nonlinear systems by using the Linear Matrix Inequalities (LMI) optimization. The observer estimates the previous mentioned variables and minimizes the effect of external disturbances on the estimation error. The model uncertainties are included in the model in a polynomial way which allows to consider the model uncertainty estimation as a fault detection problem. The residual sensitivity to faults while maintaining robustness according to a noise signal is handled by ℋ ∞ /ℋ - approach.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1274-1280
State, unknown input and uncertainty estimation for nonlinear systems using a Takagi-Sugeno model
The paper addresses a systematic procedure to deal with the state, unknown input and parameter uncertainty estimation for nonlinear time-varying systems. This is realized by designing a robust observer for dynamic nonlinear systems using a Takagi-Sugeno (T-S) multi-model (MM) approach with nonlinear outputs. The method applies the technique of descriptor systems by considering unknown inputs and parameter uncertainty as auxiliary state variables. This approach allows to apply the tools of the linear automatic to dynamic nonlinear systems by using the Linear Matrix Inequalities (LMI) optimization. The observer estimates the previous mentioned variables and minimizes the effect of external disturbances on the estimation error. The model uncertainties are included in the model in a polynomial way which allows to consider the model uncertainty estimation as a fault detection problem. The residual sensitivity to faults while maintaining robustness according to a noise signal is handled by ℋ ∞ /ℋ - approach.
- 1 November 2013
- Published by Elsevier in Journal of Process Control
- Vol. 23 (10) , 1528-1544
Estimation and diagnosis using multi-models with application to a wastewater treatment plant
- 1 November 2013
- Published by Elsevier in Journal of Process Control
- Vol. 23 (10) , 1528-1544
Estimation and diagnosis using multi-models with application to a wastewater treatment plant
- 1 September 2012
- Published by Wiley
- p. 75-113
Diagnosis of Systems with Multiple Operating Modes
- 1 January 2012
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 45 (13) , 485-490
Observer synthesis for uncertain nonlinear systems. Application to waste-water treatment plants
- 1 January 2012
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 45 (13) , 485-490
Observer synthesis for uncertain nonlinear systems. Application to waste-water treatment plants
- 1 November 2011
- Published by Elsevier in Control Engineering Practice
- Vol. 19 (11) , 1354-1362
State estimation of two-time scale multiple models. Application to wastewater treatment plant
- 1 November 2011
- Published by Elsevier in Control Engineering Practice
- Vol. 19 (11) , 1354-1362
State estimation of two-time scale multiple models. Application to wastewater treatment plant
- 1 August 2011
- Published by Elsevier in Journal of Process Control
- Vol. 21 (7) , 1105-1114
Observers design for uncertain Takagi–Sugeno systems with unmeasurable premise variables and unknown inputs. Application to a wastewater treatment plant
- 1 August 2011
- Published by Elsevier in Journal of Process Control
- Vol. 21 (7) , 1105-1114
Observers design for uncertain Takagi–Sugeno systems with unmeasurable premise variables and unknown inputs. Application to a wastewater treatment plant
- 1 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01912216,p. 5689-5694
State estimation of two-time scale multiple models with unmeasurable premise variables. Application to biological reactors
This paper deals with the state estimation of nonlinear systems. The systems under study are characterized by two-time scale models. The state estimation is performed by designing a proportional integral observer (PIO) with unknown inputs. In order to design such an observer, the nonlinear model is transformed into an equivalent multiple model form and the fast dynamics are considered as unknown inputs. An application to an ASM1 model of Wastewater Treatment Plants (WWTP) is considered and the obtained numerical results show the performances of the proposed approach.
- 1 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01912216,p. 5689-5694
State estimation of two-time scale multiple models with unmeasurable premise variables. Application to biological reactors
This paper deals with the state estimation of nonlinear systems. The systems under study are characterized by two-time scale models. The state estimation is performed by designing a proportional integral observer (PIO) with unknown inputs. In order to design such an observer, the nonlinear model is transformed into an equivalent multiple model form and the fast dynamics are considered as unknown inputs. An application to an ASM1 model of Wastewater Treatment Plants (WWTP) is considered and the obtained numerical results show the performances of the proposed approach.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1353-1358
State estimation for wastewater treatment plant with slow and fast dynamics using multiple models
This paper addresses the state estimation of two-time scale nonlinear systems by designing an unknown input multi-observer (UIMO). In order to design such an observer, the nonlinear system is transformed into an equivalent multiple model form and the fast dynamics are considered as unknown inputs. An application to a model of Wastewater Treatment Plants (WWTP) is considered and gives encouraging results.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1353-1358
State estimation for wastewater treatment plant with slow and fast dynamics using multiple models
This paper addresses the state estimation of two-time scale nonlinear systems by designing an unknown input multi-observer (UIMO). In order to design such an observer, the nonlinear system is transformed into an equivalent multiple model form and the fast dynamics are considered as unknown inputs. An application to a model of Wastewater Treatment Plants (WWTP) is considered and gives encouraging results.