Remy Tumbar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Remy Tumbar has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- David R. Williams
The Institute of Optics, University of Rochester
3 shared publications David J. Brady
University of Illinois at Urbana-Champaign
2 shared publicationsFred Reinholz
2 shared publicationsJessica Wolfing
2 shared publications- William H. Merigan
The Institute of Optics, University of Rochester
2 shared publications - Alfredo Dubra
Department of Ophthalmology, Stanford University, Palo Alto, CA 94303, USA
1 shared publication
Latest Publications
- 1 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Phase, amplitude and polarization microscope using a robust and compact interferometer
We coupled a compact and robust phase-shifting and shearing interferometer (sampling field sensor) to the imaging port of a standard, infinity corrected, transmission microscope to obtain phase, amplitude and polarization images of unstained biological samples.
- 1 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Phase, amplitude and polarization microscope using a robust and compact interferometer
We coupled a compact and robust phase-shifting and shearing interferometer (sampling field sensor) to the imaging port of a standard, infinity corrected, transmission microscope to obtain phase, amplitude and polarization images of unstained biological samples.
- 19 March 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (19) , D96-D109
Phase, amplitude, and polarization microscopy with a sampling field sensor
I describe an improved implementation of a previously reported interferometric device, the sampling field sensor (SFS) [Appl. Opt. 47, B32–B43 (2008)]. It provides X, Y, and shearing interferometric information simultaneously (space multiplexed) with amplitude and polarization information while using time-multiplexed phase shifting. Its simple common-path configuration makes it compact and vibration insensitive, as demonstrated by the phase estimation repeatability that was below the coherent noise floor (estimated at ). The SFS may be viewed as an efficient, robust and accurate full-field optical–digital interface, easy to integrate with traditional imaging systems. This is demonstrated by using the sensor as the focal plane array of a transmitted-light microscope in a straightforward setup using an illumination path polarization phase shifter. This work is focused on a qualitative demonstration and presents phase, amplitude, and polarization images of different types of human cheek cells and Caenorhabditis elegans larvae.- 19 March 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (19) , D96-D109
Phase, amplitude, and polarization microscopy with a sampling field sensor
I describe an improved implementation of a previously reported interferometric device, the sampling field sensor (SFS) [Appl. Opt. 47, B32–B43 (2008)]. It provides X, Y, and shearing interferometric information simultaneously (space multiplexed) with amplitude and polarization information while using time-multiplexed phase shifting. Its simple common-path configuration makes it compact and vibration insensitive, as demonstrated by the phase estimation repeatability that was below the coherent noise floor (estimated at ). The SFS may be viewed as an efficient, robust and accurate full-field optical–digital interface, easy to integrate with traditional imaging systems. This is demonstrated by using the sensor as the focal plane array of a transmitted-light microscope in a straightforward setup using an illumination path polarization phase shifter. This work is focused on a qualitative demonstration and presents phase, amplitude, and polarization images of different types of human cheek cells and Caenorhabditis elegans larvae.- 8 February 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (10) , B32-B43
Robust, common path, phase shifting interferometer and optical profilometer.
We describe an improved implementation of our previously reported common-path, phase shifting, and shearing interferometer. Using a time-multiplexed phase shifting scheme, we demonstrate higher sampling resolution, better light sensitivity, and use of arbitrary phase shifting algorithms. We describe microscopic imaging of the surface profile of a copper-plated silicon wafer and demonstrate that the system is vibration insensitive with repeatability. In a more general discussion of our method, we describe the different functional elements and suggest alternative designs and improvements. Possible uses include full-field coherent imaging and high dynamic range wavefront sensing, which we briefly discuss.- 8 February 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (10) , B32-B43
Robust, common path, phase shifting interferometer and optical profilometer.
We describe an improved implementation of our previously reported common-path, phase shifting, and shearing interferometer. Using a time-multiplexed phase shifting scheme, we demonstrate higher sampling resolution, better light sensitivity, and use of arbitrary phase shifting algorithms. We describe microscopic imaging of the surface profile of a copper-plated silicon wafer and demonstrate that the system is vibration insensitive with repeatability. In a more general discussion of our method, we describe the different functional elements and suggest alternative designs and improvements. Possible uses include full-field coherent imaging and high dynamic range wavefront sensing, which we briefly discuss.- 11 April 2007
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 24 (5) , 1313-1326
Large-field-of-view, modular, stabilized, adaptive-optics-based scanning laser ophthalmoscope
We describe the design and performance of an adaptive optics retinal imager that is optimized for use during dynamic correction for eye movements. The system incorporates a retinal tracker and stabilizer, a wide-field line scan scanning laser ophthalmoscope (SLO), and a high-resolution microelectromechanical-systems-based adaptive optics SLO. The detection system incorporates selection and positioning of confocal apertures, allowing measurement of images arising from different portions of the double pass retinal point-spread function (psf). System performance was excellent. The adaptive optics increased the brightness and contrast for small confocal apertures by more than and decreased the brightness of images obtained with displaced apertures, confirming the ability of the adaptive optics system to improve the psf. The retinal image was stabilized to within 90% of the time. Stabilization was sufficient for cross-correlation techniques to automatically align the images.- 11 April 2007
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 24 (5) , 1313-1326
Large-field-of-view, modular, stabilized, adaptive-optics-based scanning laser ophthalmoscope
We describe the design and performance of an adaptive optics retinal imager that is optimized for use during dynamic correction for eye movements. The system incorporates a retinal tracker and stabilizer, a wide-field line scan scanning laser ophthalmoscope (SLO), and a high-resolution microelectromechanical-systems-based adaptive optics SLO. The detection system incorporates selection and positioning of confocal apertures, allowing measurement of images arising from different portions of the double pass retinal point-spread function (psf). System performance was excellent. The adaptive optics increased the brightness and contrast for small confocal apertures by more than and decreased the brightness of images obtained with displaced apertures, confirming the ability of the adaptive optics system to improve the psf. The retinal image was stabilized to within 90% of the time. Stabilization was sufficient for cross-correlation techniques to automatically align the images.- 7 August 2006
- Published by Optica Publishing Group in Optics Express
- Vol. 14 (16) , 7144-7158
In vivo fluorescence imaging of primate retinal ganglion cells and retinal pigment epithelial cells
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 7 August 2006
- Published by Optica Publishing Group in Optics Express
- Vol. 14 (16) , 7144-7158
In vivo fluorescence imaging of primate retinal ganglion cells and retinal pigment epithelial cells
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 1 January 2006
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 32 (1) , 21-32
Aberrations induced in wavefront-guided laser refractive surgery due to shifts between natural and dilated pupil center locations
To determine the aberrations induced in wavefront-guided laser refractive surgery due to shifts in pupil center location from when aberrations are measured preoperatively (over a dilated pupil) to when they are corrected surgically (over a natural pupil). Center for Visual Science and Department of Ophthalmology, University of Rochester, Rochester, New York, USA. Shifts in pupil center were measured between dilated phenylephrine hydrochloride (Neo-Synephrine [2.5%]) and nonpharmacological mesopic conditions in 65 myopic eyes treated with wavefront-guided laser in situ keratomileusis (Technolas 217z, Bausch & Lomb). Each patient's preoperative and 6-month postoperative wave aberrations were measured over the dilated pupil. Aberrations theoretically induced by decentration of a wavefront-guided ablation were calculated and compared with those measured 6 months postoperatively (6.0 mm pupil). The mean magnitude of pupil center shift was 0.29 mm +/- 0.141 (SD) and usually occurred in the inferonasal direction as the pupil dilated. Depending on the magnitude of shift, the fraction of the higher-order postoperative root-mean-square wavefront error that could be due theoretically to pupil center decentrations was highly variable (mean 0.26 +/- 0.20 mm). There was little correlation between the calculated and 6-month postoperative wavefronts, most likely because pupil center decentrations are only 1 of several potential sources of postoperative aberrations. Measuring aberrations over a Neo-Synephrine-dilated pupil and treating them over an undilated pupil typically resulted in a shift of the wavefront-guided ablation in the superotemporal direction and an induction of higher-order aberrations. Methods referencing the aberration measurement and treatment with respect to a fixed feature on the eye will reduce the potential for inducing aberrations due to shifts in pupil center.
- 1 January 2006
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 32 (1) , 21-32
Aberrations induced in wavefront-guided laser refractive surgery due to shifts between natural and dilated pupil center locations
To determine the aberrations induced in wavefront-guided laser refractive surgery due to shifts in pupil center location from when aberrations are measured preoperatively (over a dilated pupil) to when they are corrected surgically (over a natural pupil). Center for Visual Science and Department of Ophthalmology, University of Rochester, Rochester, New York, USA. Shifts in pupil center were measured between dilated phenylephrine hydrochloride (Neo-Synephrine [2.5%]) and nonpharmacological mesopic conditions in 65 myopic eyes treated with wavefront-guided laser in situ keratomileusis (Technolas 217z, Bausch & Lomb). Each patient's preoperative and 6-month postoperative wave aberrations were measured over the dilated pupil. Aberrations theoretically induced by decentration of a wavefront-guided ablation were calculated and compared with those measured 6 months postoperatively (6.0 mm pupil). The mean magnitude of pupil center shift was 0.29 mm +/- 0.141 (SD) and usually occurred in the inferonasal direction as the pupil dilated. Depending on the magnitude of shift, the fraction of the higher-order postoperative root-mean-square wavefront error that could be due theoretically to pupil center decentrations was highly variable (mean 0.26 +/- 0.20 mm). There was little correlation between the calculated and 6-month postoperative wavefronts, most likely because pupil center decentrations are only 1 of several potential sources of postoperative aberrations. Measuring aberrations over a Neo-Synephrine-dilated pupil and treating them over an undilated pupil typically resulted in a shift of the wavefront-guided ablation in the superotemporal direction and an induction of higher-order aberrations. Methods referencing the aberration measurement and treatment with respect to a fixed feature on the eye will reduce the potential for inducing aberrations due to shifts in pupil center.
- Open Access
- 1 December 2005
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 5 (12) , 64
High-resolution in vivo imaging of primate retinal ganglion cells
We demonstrate here a method to image individual primate retinal neurons in vivo. Following the method of Dacey et al. 2003, we injected the LGN of healthy monkeys with rhodamine dextran, which is retrogradely transported to retinal ganglion cells. The monkey was sedated and in vivo images were acquired with a custom built, high resolution fluorescent scanning laser ophthalmoscope sampling the retina as finely as 512 pixels/deg. For fluorescence imaging, an argon/krypton laser provided 530 nm excitation light, and direct reflectance images could be obtained simultaneously with light from an 808nm laser diode. Estimated resolution of 2–5?m was achieved in reflectance and fluorescent images despite the small numerical aperture and higher order aberrations of the eye. Ganglion cells at 25 degrees eccentricity were resolved in individual frames. Extended light exposure with a small intense patch of light produced enhanced fluorescence (“fireworks”) similar to that observed in vitro by Dacey et al. 2003. Individual dendrites were not resolved, in part because of retinal image blur caused by the eye's aberrations. Future experiments will include the use of adaptive optics to reduce aberrations. In vivo imaging of primate ganglion cells may be useful in a number of future applications. For example, the phototoxicity of rhodamine can be exploited to create spatially localized lesions in individual classes of ganglion cell, allowing the visual significance of these classes of cells to be revealed in psychophysical experiments.
- 1 December 2005
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 5 (12) , 64
Open AccessHigh-resolution in vivo imaging of primate retinal ganglion cells
We demonstrate here a method to image individual primate retinal neurons in vivo. Following the method of Dacey et al. 2003, we injected the LGN of healthy monkeys with rhodamine dextran, which is retrogradely transported to retinal ganglion cells. The monkey was sedated and in vivo images were acquired with a custom built, high resolution fluorescent scanning laser ophthalmoscope sampling the retina as finely as 512 pixels/deg. For fluorescence imaging, an argon/krypton laser provided 530 nm excitation light, and direct reflectance images could be obtained simultaneously with light from an 808nm laser diode. Estimated resolution of 2–5?m was achieved in reflectance and fluorescent images despite the small numerical aperture and higher order aberrations of the eye. Ganglion cells at 25 degrees eccentricity were resolved in individual frames. Extended light exposure with a small intense patch of light produced enhanced fluorescence (“fireworks”) similar to that observed in vitro by Dacey et al. 2003. Individual dendrites were not resolved, in part because of retinal image blur caused by the eye's aberrations. Future experiments will include the use of adaptive optics to reduce aberrations. In vivo imaging of primate ganglion cells may be useful in a number of future applications. For example, the phototoxicity of rhodamine can be exploited to create spatially localized lesions in individual classes of ganglion cell, allowing the visual significance of these classes of cells to be revealed in psychophysical experiments.
- 1 November 2002
- Published by Optica Publishing Group in Applied Optics
- Vol. 41 (31) , 6621-6636
Sampling field sensor with anisotropic fan-out.
We describe a new common-path, phase-shift, and shearing interferometric device capable of single-shot detection of optical phase profiles. It samples the input field and uses birefringent plates to fan out phase-shifted copies of the samples in the empty space between them. The phase shifts are given by the thickness of the plates and not by the relative position of the components, as in classical interferometers. This makes the device insensitive to vibrations. We recorded repeatability better than lambda/100, even though strong shocks were applied to the air table in proximity to the system. We recorded better than lambda/1000 repeatability under quiet conditions and estimated the accuracy to be better than lambda/3000 at the shot-noise limit. In addition, the device is compact and easy to integrate in a variety of setups that require the measurement of optical phase profiles.
- 1 November 2002
- Published by Optica Publishing Group in Applied Optics
- Vol. 41 (31) , 6621-6636
Sampling field sensor with anisotropic fan-out.
We describe a new common-path, phase-shift, and shearing interferometric device capable of single-shot detection of optical phase profiles. It samples the input field and uses birefringent plates to fan out phase-shifted copies of the samples in the empty space between them. The phase shifts are given by the thickness of the plates and not by the relative position of the components, as in classical interferometers. This makes the device insensitive to vibrations. We recorded repeatability better than lambda/100, even though strong shocks were applied to the air table in proximity to the system. We recorded better than lambda/1000 repeatability under quiet conditions and estimated the accuracy to be better than lambda/3000 at the shot-noise limit. In addition, the device is compact and easy to integrate in a variety of setups that require the measurement of optical phase profiles.
- 1 January 2000
- Published by Optica Publishing Group in Applied Optics
- Vol. 39 (1) , 72-84
Wave-front sensing with a sampling field sensor
We present a new type of optical wave-front sensor: the sampling field sensor (SFS). The SFS attempts to solve the problem of real-time optical phase detection. It has a high space-bandwidth product and can be made compact and vibration insensitive. We describe a particular implementation of this sensor and compare it, through numerical simulations, with a more mature technique based on the Shack–Hartmann wave-front sensor. We also present experimental results for SFS phase estimation. Finally, we discuss the advantages and drawbacks of this SFS implementation and suggest alternative implementations.
- 1 January 2000
- Published by Optica Publishing Group in Applied Optics
- Vol. 39 (1) , 72-84
Wave-front sensing with a sampling field sensor
We present a new type of optical wave-front sensor: the sampling field sensor (SFS). The SFS attempts to solve the problem of real-time optical phase detection. It has a high space-bandwidth product and can be made compact and vibration insensitive. We describe a particular implementation of this sensor and compare it, through numerical simulations, with a more mature technique based on the Shack–Hartmann wave-front sensor. We also present experimental results for SFS phase estimation. Finally, we discuss the advantages and drawbacks of this SFS implementation and suggest alternative implementations.