Filip Čmiel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Filip Čmiel has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jaroslav Solař
VSB - Technical University of Ostrava
7 shared publications Radek Fabian
VŠB – TU Ostrava
5 shared publicationsMarketa Kozakova
VSB - Technical University of Ostrava
2 shared publications- Petr Alexa
VSB – Technical University of Ostrava
2 shared publications Zdeněk Peřina
VŠB – TU Ostrava
2 shared publicationsBlahoslav Maršálek
Academy of Science of Czech Republic
1 shared publication
Latest Publications
- 9 October 2017
- Published by SAGE Publications in Journal of Building Physics
- Vol. 41 (6) , 533-546
Infrared thermographic measurement of the surface temperature and emissivity of glossy materials
Determination of the surface temperature and emissivity of glossy materials is a complicated task due to the relatively wide range of emissivity values and the reflection of infrared radiation from surrounding objects. As a consequence, standard methods used in infrared thermography are not applicable. In this article, an alternative method is proposed for the measurement of the surface temperature and emissivity of glossy materials used in the external structures of buildings that is based on an external source of thermal radiation. It is shown that the method gives quite accurate values of emissivity of both low- and high-emissivity glossy materials, whereas the surface temperature of low-emissivity glossy materials is less accurate and strongly depends on the accuracy of the used thermal camera.
- 9 October 2017
- Published by SAGE Publications in Journal of Building Physics
- Vol. 41 (6) , 533-546
Infrared thermographic measurement of the surface temperature and emissivity of glossy materials
Determination of the surface temperature and emissivity of glossy materials is a complicated task due to the relatively wide range of emissivity values and the reflection of infrared radiation from surrounding objects. As a consequence, standard methods used in infrared thermography are not applicable. In this article, an alternative method is proposed for the measurement of the surface temperature and emissivity of glossy materials used in the external structures of buildings that is based on an external source of thermal radiation. It is shown that the method gives quite accurate values of emissivity of both low- and high-emissivity glossy materials, whereas the surface temperature of low-emissivity glossy materials is less accurate and strongly depends on the accuracy of the used thermal camera.
- 3 August 2015
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1122, 205-209
The Thermographic Measuring of the Surface Temperature of the Peripheral Wall after Removing a Technical Device for Elimination of Reflected Radiation
It is possible to measure the surface temperature of a peripheral wall in a certain point with an advantage when using a technical device for elimination of reflected radiation. Other advantages of the diagnostics of the peripheral wall using the infrared termographic system after removing the mentioned technical device from the wall is, that if we determine (using the technical device) the surface temperature in a determined point, then we are, after inserting it into the termographic systém, able to determine retroactively the real value of the apparent reflected temperature, and this is even done with higher accuracy. Then we use the value for a termographic measuring of all the surface of the peripheral wall, keeping the same angle of scanning.
- 3 August 2015
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1122, 205-209
The Thermographic Measuring of the Surface Temperature of the Peripheral Wall after Removing a Technical Device for Elimination of Reflected Radiation
It is possible to measure the surface temperature of a peripheral wall in a certain point with an advantage when using a technical device for elimination of reflected radiation. Other advantages of the diagnostics of the peripheral wall using the infrared termographic system after removing the mentioned technical device from the wall is, that if we determine (using the technical device) the surface temperature in a determined point, then we are, after inserting it into the termographic systém, able to determine retroactively the real value of the apparent reflected temperature, and this is even done with higher accuracy. Then we use the value for a termographic measuring of all the surface of the peripheral wall, keeping the same angle of scanning.
- 3 August 2015
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1122, 237-240
Verification of Applicability of Thermographical Measuring of the Surface Temperature and the Influence of Emissivity of Glossy Materials while Eliminating the Reflected Radiation Using a Metal Shield
The exact determination of emissivity and the following determination of the surface temperature of glossy materials can be carried out e. g. after applying a material with a known value of emissivity on the surface (e. g. self-adhesive foil or spray tint). The contribution deals with other possibility of determination of surface temperature and the influence of emissivity of glossy materials using a metal shield that reduces the negative influence of the reflected radiation during the termographical measurement.
- 3 August 2015
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1122, 237-240
Verification of Applicability of Thermographical Measuring of the Surface Temperature and the Influence of Emissivity of Glossy Materials while Eliminating the Reflected Radiation Using a Metal Shield
The exact determination of emissivity and the following determination of the surface temperature of glossy materials can be carried out e. g. after applying a material with a known value of emissivity on the surface (e. g. self-adhesive foil or spray tint). The contribution deals with other possibility of determination of surface temperature and the influence of emissivity of glossy materials using a metal shield that reduces the negative influence of the reflected radiation during the termographical measurement.
- 3 August 2015
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1122, 233-236
Verification of Applicability of Alternate Sources of Heat for Determination of the Surface Temperature and Emissivity of Glossy Materials
The value of the surface temperature and emissivity of glossy materials can be determined by the method of four points. However, in practical measurements on the peripheral walls of buildings there may occur situations where four points are not available. In such case it is possible to use alternate sources of heat.
- 3 August 2015
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1122, 233-236
Verification of Applicability of Alternate Sources of Heat for Determination of the Surface Temperature and Emissivity of Glossy Materials
The value of the surface temperature and emissivity of glossy materials can be determined by the method of four points. However, in practical measurements on the peripheral walls of buildings there may occur situations where four points are not available. In such case it is possible to use alternate sources of heat.
- 17 April 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 923, 187-190
The Elimination of Reflected Radiation in an Infrared Thermographic Measurement in the Exterior
The reflected radiation significantly negatively influences the results of the quantitative infrared thermographic measurement in the exterior. The paper deals the method of elimination of reflected radiation using appropriate equipment including examples of practical results of measurements.
- 17 April 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 923, 187-190
The Elimination of Reflected Radiation in an Infrared Thermographic Measurement in the Exterior
The reflected radiation significantly negatively influences the results of the quantitative infrared thermographic measurement in the exterior. The paper deals the method of elimination of reflected radiation using appropriate equipment including examples of practical results of measurements.
- 17 April 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 923, 183-186
Observation of Biological Pests on Building Facades by Thermocamera
Microorganisms on the facades of buildings (eg, algae and cyanobacteria) are the harmful factors that cause destruction of the surface of building materials in exterior (facade paints, plasters, masonry, stone, concrete, etc.). One of the properties of listed biological factors is the production of thermal energy, which can vary in different species. Mentioned energy can be recorded using infrared thermography. The paper contains the results of the examined expressions of the biological pests on the insulated facades of the buildings using infrared thermography.
- 17 April 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 923, 183-186
Observation of Biological Pests on Building Facades by Thermocamera
Microorganisms on the facades of buildings (eg, algae and cyanobacteria) are the harmful factors that cause destruction of the surface of building materials in exterior (facade paints, plasters, masonry, stone, concrete, etc.). One of the properties of listed biological factors is the production of thermal energy, which can vary in different species. Mentioned energy can be recorded using infrared thermography. The paper contains the results of the examined expressions of the biological pests on the insulated facades of the buildings using infrared thermography.
- 25 January 2013
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 652-654, 1169-1172
Experimental Measurements of the Selected Properties of AeroTherm
The thermally insulating compound AeroTherm appeared on the market in recent times. The manufacturer determines its thermal insulating properties. The aim of this article is to verify thermal-technical properties of AeroThermu on the lining from YTONG (autoclaved aerated concrete blocks) that serves as the supporting base.
- 25 January 2013
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 652-654, 1169-1172
Experimental Measurements of the Selected Properties of AeroTherm
The thermally insulating compound AeroTherm appeared on the market in recent times. The manufacturer determines its thermal insulating properties. The aim of this article is to verify thermal-technical properties of AeroThermu on the lining from YTONG (autoclaved aerated concrete blocks) that serves as the supporting base.
- 1 January 2013
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 649, 65-68
Effect of the Geometric Solution of Cladding on the Quality of the Indoor Microclimate
This paper deals with the comparison of the effect of the contact thermal insulation in the connection of the loggia slab to the stair wall of construction panel system T 06-B produced in Prefa Olomouc. Measurements took place in two panel houses, where parameters of internal and external air were measured. The thermally insulated building is compared with the untreated building. The temperature factor at the internal surface, which eliminates the boundary conditions of the measurement, was used as a comparative element. The measured values were statistically evaluated.
- 1 January 2013
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 649, 65-68
Effect of the Geometric Solution of Cladding on the Quality of the Indoor Microclimate
This paper deals with the comparison of the effect of the contact thermal insulation in the connection of the loggia slab to the stair wall of construction panel system T 06-B produced in Prefa Olomouc. Measurements took place in two panel houses, where parameters of internal and external air were measured. The thermally insulated building is compared with the untreated building. The temperature factor at the internal surface, which eliminates the boundary conditions of the measurement, was used as a comparative element. The measured values were statistically evaluated.
- Open Access
- 1 January 2011
- Published by VSB - Technical University of Ostrava in Transactions of the VŠB – Technical University of Ostrava, Civil Engineering Series
- Vol. XI (1) , 1-8
The Improvement of Thermal Properties of Cladding of the Educational Institution in Frydek Mistek
- 1 January 2011
- Published by VSB - Technical University of Ostrava in Transactions of the VŠB – Technical University of Ostrava, Civil Engineering Series
- Vol. XI (1) , 1-8
Open AccessThe Improvement of Thermal Properties of Cladding of the Educational Institution in Frydek Mistek