Piotr Szwedziak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Piotr Szwedziak has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Vargas Jentzsch
SAMS Research Group Université de Strasbourg CNRS Institut Charles Sadron UPR 22 Strasbourg France
3 shared publications - Jan Löwe
MRC Laboratory of Molecular Biology, Cambridge CB2 0QH, UK
3 shared publications - Michel Rickhaus
Department of Organic Chemistry, University of Geneva, 30 quai Ernest-Ansermet, Geneva, Switzerland, 1211
3 shared publications - Andres Kaech
Center for Microscopy and Image Analysis, University of Zurich, Zurich, Switzerland
2 shared publications - Andrzej Dziembowski
International Institute of Molecular and Cell Biology in Warsaw
2 shared publications - Ariel Amir
Department of Physics of Complex Systems, Weizmann Institute of Science, Rehovot, Israel
2 shared publications
Latest Publications
- Open Access
- 21 May 2026
- Published by Elsevier in SSRN Electronic Journal
Automated LN₂ refill device for uninterrupted cryoFIB-SEM operations
Due to recent technological advances, in situ structural cell biology is becoming a high throughput microscopy technique as all the steps of the workflow, from sample preparation to data analysis, are executed faster, more reliable and more reproducible. Sample thinning by cryoFIB-SEM is an essential tool in preparing electron transparent lamellae of biological specimens suitable for further characterization by cryoET. Modern cryoFIB-SEM instruments can be operated remotely and are capable of automated and unsupervised lamellae preparation. To take full advantage of these developments they need a constant supply of LN₂ to maintain cryogenic conditions inside the microscope chamber. Here, we introduce a custom automated LN₂ refill system that is compatible with gas cooled cryostages, supports long-term cryoFIB-SEM operations and liberates the user from highly repetitive and manual work. We believe this solution can be utilized with other cryoSEM or cryoFIB-SEM devices requiring N2 gas-flow cooling and might be particularly beneficial in BSL-3 or BSL-4 laboratories where minimizing physical presence is essential for biosafety reasons.
- 21 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAutomated LN₂ refill device for uninterrupted cryoFIB-SEM operations
Due to recent technological advances, in situ structural cell biology is becoming a high throughput microscopy technique as all the steps of the workflow, from sample preparation to data analysis, are executed faster, more reliable and more reproducible. Sample thinning by cryoFIB-SEM is an essential tool in preparing electron transparent lamellae of biological specimens suitable for further characterization by cryoET. Modern cryoFIB-SEM instruments can be operated remotely and are capable of automated and unsupervised lamellae preparation. To take full advantage of these developments they need a constant supply of LN₂ to maintain cryogenic conditions inside the microscope chamber. Here, we introduce a custom automated LN₂ refill system that is compatible with gas cooled cryostages, supports long-term cryoFIB-SEM operations and liberates the user from highly repetitive and manual work. We believe this solution can be utilized with other cryoSEM or cryoFIB-SEM devices requiring N2 gas-flow cooling and might be particularly beneficial in BSL-3 or BSL-4 laboratories where minimizing physical presence is essential for biosafety reasons.
- Open Access
Automated LN 2 refill device for uninterrupted cryoFIB-SEM operations
Due to recent technological advances, in situ structural cell biology is becoming a high throughput microscopy technique as all the steps of the workflow, from sample preparation to data analysis, are executed faster, more reliable and more reproducible. Sample thinning by cryoFIB-SEM is an essential tool in preparing electron transparent lamellae of biological specimens suitable for further characterization by cryoET. Modern cryoFIB-SEM instruments can be operated remotely and are capable of automated and unsupervised lamellae preparation. To take full advantage of these developments they need a constant supply of LN 2 to maintain cryogenic conditions inside the microscope chamber. Here, we introduce a custom automated LN 2 refill system that is compatible with gas cooled cryostages, supports long-term cryoFIB-SEM operations and liberates the user from highly repetitive and manual work. We believe this solution can be utilized with other cryoSEM or cryoFIB-SEM devices requiring N2 gas-flow cooling.
Open AccessAutomated LN 2 refill device for uninterrupted cryoFIB-SEM operations
Due to recent technological advances, in situ structural cell biology is becoming a high throughput microscopy technique as all the steps of the workflow, from sample preparation to data analysis, are executed faster, more reliable and more reproducible. Sample thinning by cryoFIB-SEM is an essential tool in preparing electron transparent lamellae of biological specimens suitable for further characterization by cryoET. Modern cryoFIB-SEM instruments can be operated remotely and are capable of automated and unsupervised lamellae preparation. To take full advantage of these developments they need a constant supply of LN 2 to maintain cryogenic conditions inside the microscope chamber. Here, we introduce a custom automated LN 2 refill system that is compatible with gas cooled cryostages, supports long-term cryoFIB-SEM operations and liberates the user from highly repetitive and manual work. We believe this solution can be utilized with other cryoSEM or cryoFIB-SEM devices requiring N2 gas-flow cooling.
- Open Access
- 6 November 2025
- Published by Springer Nature in BMC Methods
- Vol. 2 (1) , 1-12
In situ structural analysis of mammalian cells using a 200 kV electron cryomicroscope – implications for research infrastructure
- 6 November 2025
- Published by Springer Nature in BMC Methods
- Vol. 2 (1) , 1-12
Open AccessIn situ structural analysis of mammalian cells using a 200 kV electron cryomicroscope – implications for research infrastructure
- Open Access
- 29 August 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (35) , eadx9030
Amyloid-β oligomers, curvilinear and annular assemblies, imaged by cryo-ET, cryo-EM, and AFM
Prefibrillar structures of the amyloid-β (Aβ) peptide are central to cytotoxicity in Alzheimer’s disease. Time-resolved imaging of oligomers has enabled quantification of their extension. A snapshot of these prefibrillar assemblies has been characterized using a combination of cryo–electron tomography (cryo-ET), cryo–electron microscopy (cryo-EM) single-particle analysis, and atomic force microscopy (AFM). A highly consistent diameter for all curvilinear protofibrils and oligomers of 2.8 nanometers suggests that these assemblies are structural extensions from the smaller oligomers. In situ AFM confirms that spherical oligomers template and extend over time into curvilinear protofibrils. Furthermore, their basic cross section suggests that amyloid fibrils might be initiated by the lateral binding of two curvilinear protofibrils. Cryo-ET/EM single particles also reveal ring-shaped annular assemblies. These have a central internal channel, ~1.4 nanometers in diameter, which is capable of traversing lipid membranes. Large conductance recorded using patch-clamp electrophysiology matches the internal diameter of the Aβ annular architecture.
- 29 August 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (35) , eadx9030
Open AccessAmyloid-β oligomers, curvilinear and annular assemblies, imaged by cryo-ET, cryo-EM, and AFM
Prefibrillar structures of the amyloid-β (Aβ) peptide are central to cytotoxicity in Alzheimer’s disease. Time-resolved imaging of oligomers has enabled quantification of their extension. A snapshot of these prefibrillar assemblies has been characterized using a combination of cryo–electron tomography (cryo-ET), cryo–electron microscopy (cryo-EM) single-particle analysis, and atomic force microscopy (AFM). A highly consistent diameter for all curvilinear protofibrils and oligomers of 2.8 nanometers suggests that these assemblies are structural extensions from the smaller oligomers. In situ AFM confirms that spherical oligomers template and extend over time into curvilinear protofibrils. Furthermore, their basic cross section suggests that amyloid fibrils might be initiated by the lateral binding of two curvilinear protofibrils. Cryo-ET/EM single particles also reveal ring-shaped annular assemblies. These have a central internal channel, ~1.4 nanometers in diameter, which is capable of traversing lipid membranes. Large conductance recorded using patch-clamp electrophysiology matches the internal diameter of the Aβ annular architecture.
- Open Access
- 5 May 2025
- Published by EMBL-EBI
Electron cryotomography of thin edges of U2OS cells using a 200 kV cryoTEM
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- 5 May 2025
- Published by EMBL-EBI
Open AccessElectron cryotomography of thin edges of U2OS cells using a 200 kV cryoTEM
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- Open Access
- 5 May 2025
- Published by EMBL-EBI
Electron cryotomography of thin edges of U2OS cells using a 200 kV cryoTEM
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- 5 May 2025
- Published by EMBL-EBI
Open AccessElectron cryotomography of thin edges of U2OS cells using a 200 kV cryoTEM
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- Open Access
- 5 May 2025
- Published by EMBL-EBI
Electron cryotomography of thin edges of U2OS cells using a 200 kV cryoTEM
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- 5 May 2025
- Published by EMBL-EBI
Open AccessElectron cryotomography of thin edges of U2OS cells using a 200 kV cryoTEM
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- Open Access
- 5 May 2025
- Published by EMBL-EBI
Electron cryotomography of thin edges of U2OS cells using a 200 kV cryoTEM
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- 5 May 2025
- Published by EMBL-EBI
Open AccessElectron cryotomography of thin edges of U2OS cells using a 200 kV cryoTEM
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- Open Access
- 24 April 2025
- Published by EMBL-EBI
Electron cryotomography of thin edges of U2OS cells using a 200 kV cryoTEM
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- 24 April 2025
- Published by EMBL-EBI
Open AccessElectron cryotomography of thin edges of U2OS cells using a 200 kV cryoTEM
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- Open Access
In situ structural analysis of mammalian cells using a 200 kV electron cryomicroscope – implications for research infrastructure
Background: Electron cryotomography is a powerful imaging technique allowing for studying functional cellular modules in their native environment with macromolecular resolution. However, it requires access to complex and expensive instrumentation, typically a 300 kV electron cryomicroscope equipped with an energy filter. Simpler and cheaper 200 and 100 kV instruments have been successfully used for single particle cryoEM analyses, which has helped to democratize the technique and broaden access. It has not been systematically studied if 200 kV electron cryomicroscopes can deliver meaningful and interpretable data with respect to electron cryotomography applications. Methods: Here, we set out to investigate if a 200 kV electron cryomicroscope without an energy filter can be utilized for in situ structural studies of mammalian cells by electron cryotomography of thin cell edges followed by extensive image analysis including segmentations, subtomogram averaging and molecular sociology studies of lipid droplets. Results: We demonstrate that the resulting tomograms of thin edges of U2OS cells are of sufficient quality to annotate the contents of the cell and observe spatial inter-relationships among macromolecules. In particular, we undertook a molecular sociology analysis of lipid droplets and addressed their subcellular distribution and interactions with other organelles. Additionally, we performed subtomogram averaging of purified 70S ribosomes that resulted in ∼15 Å resolution 3D reconstruction. Finally, we examined geographical distribution and scientific output of the two most common electron cryomicroscopy platforms and deduced that 200 kV instruments are heavily underutilized with respect to electron cryotomography applications. Discussion: This study demonstrates that 200 kV electron cryomicroscopes can be utilized for structural cell biology studies by electron cryotomography. Given the favorable ratio of their versatility versus costs we foresee that 200 kV electron cryomicroscopes will become workhorses of local electron cryomicroscopy facilities.
Open AccessIn situ structural analysis of mammalian cells using a 200 kV electron cryomicroscope – implications for research infrastructure
Background: Electron cryotomography is a powerful imaging technique allowing for studying functional cellular modules in their native environment with macromolecular resolution. However, it requires access to complex and expensive instrumentation, typically a 300 kV electron cryomicroscope equipped with an energy filter. Simpler and cheaper 200 and 100 kV instruments have been successfully used for single particle cryoEM analyses, which has helped to democratize the technique and broaden access. It has not been systematically studied if 200 kV electron cryomicroscopes can deliver meaningful and interpretable data with respect to electron cryotomography applications. Methods: Here, we set out to investigate if a 200 kV electron cryomicroscope without an energy filter can be utilized for in situ structural studies of mammalian cells by electron cryotomography of thin cell edges followed by extensive image analysis including segmentations, subtomogram averaging and molecular sociology studies of lipid droplets. Results: We demonstrate that the resulting tomograms of thin edges of U2OS cells are of sufficient quality to annotate the contents of the cell and observe spatial inter-relationships among macromolecules. In particular, we undertook a molecular sociology analysis of lipid droplets and addressed their subcellular distribution and interactions with other organelles. Additionally, we performed subtomogram averaging of purified 70S ribosomes that resulted in ∼15 Å resolution 3D reconstruction. Finally, we examined geographical distribution and scientific output of the two most common electron cryomicroscopy platforms and deduced that 200 kV instruments are heavily underutilized with respect to electron cryotomography applications. Discussion: This study demonstrates that 200 kV electron cryomicroscopes can be utilized for structural cell biology studies by electron cryotomography. Given the favorable ratio of their versatility versus costs we foresee that 200 kV electron cryomicroscopes will become workhorses of local electron cryomicroscopy facilities.