Ghasem Karim-Nezhad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ghasem Karim-Nezhad has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Zeynab Khorablou
Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, 53714-161, Iran
10 shared publications - Mohammad Hasanzadeh
Pharmaceutical Analysis Research Center, Pharmaceutical Sciences Institute, Tabriz University of Medical Sciences, Tabriz, Iran
8 shared publications - Balal Khalilzadeh
Stem Cell Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; New Material and Green Chemistry Research Center, Khazar University, 41 Mehseti Street, Baku, AZ1096, Azerbaijan
7 shared publications Lotfali Saghatforoush
Department of Chemistry, Faculty of Science, Payame Noor University (PNU), P. O. Box: 58168-45164, Khoy, Iran
7 shared publications- Nasrin Shadjou
Department of Nanotechnology, Faculty of Chemistry, Urmia University, Urmia, Iran
7 shared publications Parisa Seyed Dorraji
Payame Noor Univ, Dept Chem, Tehran, Iran
7 shared publications
Latest Publications
- 1 December 2018
- Vol. 17 (1) , 52-62
Synergistic Effect of ZnO Nanoparticles and Carbon Nanotube and Polymeric Film on Electrochemical Oxidation of Acyclovir
A simple and selective carbon paste electrode has been developed for the electrochemical determination of acyclovir (ACV). This electrode was designed by incorporation of multiwalled carbon nanotubes (MWCNTs) and ZnO nanoparticles into the carbon paste matrix, and then poly (o-aminophenol; OAP) film were subsequently electropolymerized on it. The surface structure of nanoparticles were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Surface morphology and electrochemical properties of the prepared nanocomposite modified electrode were investigated by SEM and cyclic voltammetry (CV). The calibration graph was linear over the concentration range 0.089 to 7.96 mu g mL(-1) for ACV determination with a detection limit of 0.067 mu g mL(-1). The proposed electrode was successfully applied for ACV determination in pharmaceutical formulations with satisfactory results.
- 1 December 2018
- Vol. 17 (1) , 52-62
Synergistic Effect of ZnO Nanoparticles and Carbon Nanotube and Polymeric Film on Electrochemical Oxidation of Acyclovir
A simple and selective carbon paste electrode has been developed for the electrochemical determination of acyclovir (ACV). This electrode was designed by incorporation of multiwalled carbon nanotubes (MWCNTs) and ZnO nanoparticles into the carbon paste matrix, and then poly (o-aminophenol; OAP) film were subsequently electropolymerized on it. The surface structure of nanoparticles were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Surface morphology and electrochemical properties of the prepared nanocomposite modified electrode were investigated by SEM and cyclic voltammetry (CV). The calibration graph was linear over the concentration range 0.089 to 7.96 mu g mL(-1) for ACV determination with a detection limit of 0.067 mu g mL(-1). The proposed electrode was successfully applied for ACV determination in pharmaceutical formulations with satisfactory results.
- 16 October 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (12) , 2908-2915
Preparation of a Double‐step Modified Carbon Paste Electrode for Trace Quantification of Acyclovir Using TiO2 Nanoparticle and β‐Cyclodextrin
In this work we reported, a simple and reproducible double‐step modified carbon paste electrode (CPE) for recognition and designation of Acyclovir (ACV). In the first stage, for acquiring the structure of TiO2 NPs‐CPE, 5 % TiO2 nanoparticles (NPs) doped into the electrode tissue. In the second stage, β‐Cyclodextrin (β‐CD) anchored on the TiO2 NPs‐CPE surface by electropolymerization which yields a β‐CD/TiO2 NPs‐CPE. Topography, characteristics and electrochemical response of the fabricated electrodes with such techniques as: the field emission scanning electron microscopy (FESEM), chronocoulometry (CC), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were analyzed. Also the spent TiO2 NPs powders were characterized by X‐ray diffraction (XRD). The results illustrated that this sensor designed efficiently increases the surface area of composite electrode and the performance of the oxidation of ACV at the surface modified electrode compared to the bare electrode improved. Under the desirable situations, the proposed of analytical procedure was proved to be applicable in two linear calibration ranges betwixt 0.09 to 2.98 and 2.98 to 47.61 μM. The detection limit was estimated for low concentrations ACV 21 nM (S/N=3). Eventually, the fabricated composite electrode was successfully applied for the detection of trace amounts of the ACV in the blood serum samples.
- 16 October 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (12) , 2908-2915
Preparation of a Double‐step Modified Carbon Paste Electrode for Trace Quantification of Acyclovir Using TiO2 Nanoparticle and β‐Cyclodextrin
In this work we reported, a simple and reproducible double‐step modified carbon paste electrode (CPE) for recognition and designation of Acyclovir (ACV). In the first stage, for acquiring the structure of TiO2 NPs‐CPE, 5 % TiO2 nanoparticles (NPs) doped into the electrode tissue. In the second stage, β‐Cyclodextrin (β‐CD) anchored on the TiO2 NPs‐CPE surface by electropolymerization which yields a β‐CD/TiO2 NPs‐CPE. Topography, characteristics and electrochemical response of the fabricated electrodes with such techniques as: the field emission scanning electron microscopy (FESEM), chronocoulometry (CC), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were analyzed. Also the spent TiO2 NPs powders were characterized by X‐ray diffraction (XRD). The results illustrated that this sensor designed efficiently increases the surface area of composite electrode and the performance of the oxidation of ACV at the surface modified electrode compared to the bare electrode improved. Under the desirable situations, the proposed of analytical procedure was proved to be applicable in two linear calibration ranges betwixt 0.09 to 2.98 and 2.98 to 47.61 μM. The detection limit was estimated for low concentrations ACV 21 nM (S/N=3). Eventually, the fabricated composite electrode was successfully applied for the detection of trace amounts of the ACV in the blood serum samples.
- Open Access
- 1 July 2018
- Vol. 8 (3) , 266-275
Electrochemical Analysis of Tryptophan using a Nanostructuring Electrode with Multi-walled Carbon Nanotubes and Cetyltrimethylammonium bromide Nanocomposite
- 1 July 2018
- Vol. 8 (3) , 266-275
Open AccessElectrochemical Analysis of Tryptophan using a Nanostructuring Electrode with Multi-walled Carbon Nanotubes and Cetyltrimethylammonium bromide Nanocomposite
- 8 February 2018
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 15 (4) , 905-913
A promising electrochemical sensing platform based on copper nanoparticles-decorated polymer in carbon nanotube electrode for monitoring methimazole
- 8 February 2018
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 15 (4) , 905-913
A promising electrochemical sensing platform based on copper nanoparticles-decorated polymer in carbon nanotube electrode for monitoring methimazole
- Open Access
- 1 January 2018
- Published by National Library of Serbia in Journal of the Serbian Chemical Society
- Vol. 83 (4) , 449-462
Signal amplification for sumatriptan sensing based on polymeric surface decorated with Cu nanoparticles
A new nanocomposite, Cu NPs/poly-melamine, was deposited on a glassy carbon electrode by cyclic voltammetry. The uniform deposition of the nanocomposite was observed by the field emission scanning electron microscopy. The electron transfer characteristics of the drug sumatriptan (SUM), was greatly improved on the modified electrode. The prepared electrode was used for the sensitive determination of SUM by the differential pulse voltammetry. Linear calibration curve was obtained in the concentration ranges of 0.08–0.58 and 0.58–6.5 μM, and the detection limit of 0.025 μM. The proposed method was evaluated by the determination of SUM in human biological fluids such as urine and blood plasma with satisfactory results (recovery > 99 %).
- 1 January 2018
- Published by National Library of Serbia in Journal of the Serbian Chemical Society
- Vol. 83 (4) , 449-462
Open AccessSignal amplification for sumatriptan sensing based on polymeric surface decorated with Cu nanoparticles
A new nanocomposite, Cu NPs/poly-melamine, was deposited on a glassy carbon electrode by cyclic voltammetry. The uniform deposition of the nanocomposite was observed by the field emission scanning electron microscopy. The electron transfer characteristics of the drug sumatriptan (SUM), was greatly improved on the modified electrode. The prepared electrode was used for the sensitive determination of SUM by the differential pulse voltammetry. Linear calibration curve was obtained in the concentration ranges of 0.08–0.58 and 0.58–6.5 μM, and the detection limit of 0.025 μM. The proposed method was evaluated by the determination of SUM in human biological fluids such as urine and blood plasma with satisfactory results (recovery > 99 %).
- 25 October 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (45) , 6394-6402
Selective analysis of epinephrine in the presence of uric acid by using an amplified electrochemical sensor employing a gold nanoparticle decorated cysteic acid film
In the present work, an effective electrochemical sensor for the rapid and selective determination of epinephrine (EP) in the presence of uric acid (UA) based on a glassy carbon electrode (GCE) modified with gold nanoparticles (AuNPs) and cysteic acid was applied. This modified electrode exhibited a potent and persistent electron mediating behavior followed by well separated oxidation peaks of EP and UA. The surface and electrochemical characterization of the modified electrode was performed by field emission scanning electron microscopy (FESEM), chronocoulometry (CC), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The effective surface area (0.087 cm2) which is 4.8 times as much as that of the unmodified GCE, electron transfer coefficient (α = 0.31) and number of electrons involved in the rate determining step (nα = 2.2 ≈ 2) for EP were also determined using electrochemical approaches. Under optimal conditions, the AuNPs/cysteic acid/GCE displays a linear response for 0.4–11.7 μM EP and a good detection sensitivity of 1.2631 μA μM−1 and the detection limit is 80 nM (S/N = 3). The suggested sensor was successfully used for the determination of analytes in real samples with satisfactory results.
- 25 October 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (45) , 6394-6402
Selective analysis of epinephrine in the presence of uric acid by using an amplified electrochemical sensor employing a gold nanoparticle decorated cysteic acid film
In the present work, an effective electrochemical sensor for the rapid and selective determination of epinephrine (EP) in the presence of uric acid (UA) based on a glassy carbon electrode (GCE) modified with gold nanoparticles (AuNPs) and cysteic acid was applied. This modified electrode exhibited a potent and persistent electron mediating behavior followed by well separated oxidation peaks of EP and UA. The surface and electrochemical characterization of the modified electrode was performed by field emission scanning electron microscopy (FESEM), chronocoulometry (CC), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The effective surface area (0.087 cm2) which is 4.8 times as much as that of the unmodified GCE, electron transfer coefficient (α = 0.31) and number of electrons involved in the rate determining step (nα = 2.2 ≈ 2) for EP were also determined using electrochemical approaches. Under optimal conditions, the AuNPs/cysteic acid/GCE displays a linear response for 0.4–11.7 μM EP and a good detection sensitivity of 1.2631 μA μM−1 and the detection limit is 80 nM (S/N = 3). The suggested sensor was successfully used for the determination of analytes in real samples with satisfactory results.
- Open Access
- 1 April 2017
- Published by The Journal of Food and Drug Analysis (JFDA), Food and Drug Administration, Taiwan (TFDA) in Journal of Food and Drug Analysis
- Vol. 25 (2) , 293-301
Voltammetric sensor for tartrazine determination in soft drinks using poly ( p -aminobenzenesulfonic acid)/zinc oxide nanoparticles in carbon paste electrode
Zinc oxide nanoparticles (ZnO NPs) and p-aminobenzenesulfonic acid (p-ABSA) were used to fabricate a modified electrode, as a highly sensitive and selective voltammetric sensor, for the determination of tartrazine. A fast and easy method for the fabrication of poly p-ABSA (Pp-ABSA)/ZnO NPs-carbon paste electrode (Pp-ABSA/ZnO NPs-CPE) by cyclic voltammetry was used. By combining the benefits of Pp-ABSA, ZnO NPs, and CPE, the resulted modified electrode exhibited outstanding electrocatalytic activity in terms of tartrazine oxidation by giving much higher peak currents than those obtained for the unmodified CPE and also other constructed electrodes. The effects of various experimental parameters on the voltammetric response of tartrazine were investigated. At the optimum conditions, the sensor has a linear response in the concentration range of 0349-5.44 μM, a good detection sensitivity (2.2034 μA/μM), and a detection limit of 80 nM of tartrazine. The proposed electrode was used for the determination of tartrazine in soft drinks with satisfactory results.
- 1 April 2017
- Published by The Journal of Food and Drug Analysis (JFDA), Food and Drug Administration, Taiwan (TFDA) in Journal of Food and Drug Analysis
- Vol. 25 (2) , 293-301
Open AccessVoltammetric sensor for tartrazine determination in soft drinks using poly ( p -aminobenzenesulfonic acid)/zinc oxide nanoparticles in carbon paste electrode
Zinc oxide nanoparticles (ZnO NPs) and p-aminobenzenesulfonic acid (p-ABSA) were used to fabricate a modified electrode, as a highly sensitive and selective voltammetric sensor, for the determination of tartrazine. A fast and easy method for the fabrication of poly p-ABSA (Pp-ABSA)/ZnO NPs-carbon paste electrode (Pp-ABSA/ZnO NPs-CPE) by cyclic voltammetry was used. By combining the benefits of Pp-ABSA, ZnO NPs, and CPE, the resulted modified electrode exhibited outstanding electrocatalytic activity in terms of tartrazine oxidation by giving much higher peak currents than those obtained for the unmodified CPE and also other constructed electrodes. The effects of various experimental parameters on the voltammetric response of tartrazine were investigated. At the optimum conditions, the sensor has a linear response in the concentration range of 0349-5.44 μM, a good detection sensitivity (2.2034 μA/μM), and a detection limit of 80 nM of tartrazine. The proposed electrode was used for the determination of tartrazine in soft drinks with satisfactory results.
- 1 April 2017
- Published by American Scientific Publishers in Sensor Letters
- Vol. 15 (4) , 308-314
Enhancing the Sensitivity of Ketotifen Electrochemical Sensor Based on Electropolymerization of p-Aminobenzenesulfonic Acid on Glassy Carbon Electrode
In this letter, A poly(p-aminobenzenesulfonic acid) modified glassy carbon electrode (Pp-ABSA/GCE) is fabricated by electropolymerization of p-aminobenzenesulfonic acid (p-ABSA) monomer using cyclic voltammetry (CV) and was used for the determination of Ketotifen (KET). The surface morphology of the modified electrode was characterized by field emission scanning electron microscopy. Cyclic and differential voltammetric techniques were employed to study the electrochemical responses of KET at Pp-ABSA/GCE and bare GCE. KET exhibited an irreversible oxidation peak at both modified and bare GCE. The anodic peak currents of KET on the Pp-ABSA/GCE were about 8 fold higher than that of the unmodified electrodes. The influence of various parameters on the Pp-ABSA/GCE was investigated. Under the optimized working conditions, the oxidation peak current is linear to the KET concentration in the ranges of 0.2–6.4 μM and 6.4– 22.48 μM with a detection limit of 0.36 μM. The Pp-ABSA/GCE has been successfully applied and validated by analyzing KET in blood and pharmaceutical samples.
- 1 April 2017
- Published by American Scientific Publishers in Sensor Letters
- Vol. 15 (4) , 308-314
Enhancing the Sensitivity of Ketotifen Electrochemical Sensor Based on Electropolymerization of p-Aminobenzenesulfonic Acid on Glassy Carbon Electrode
In this letter, A poly(p-aminobenzenesulfonic acid) modified glassy carbon electrode (Pp-ABSA/GCE) is fabricated by electropolymerization of p-aminobenzenesulfonic acid (p-ABSA) monomer using cyclic voltammetry (CV) and was used for the determination of Ketotifen (KET). The surface morphology of the modified electrode was characterized by field emission scanning electron microscopy. Cyclic and differential voltammetric techniques were employed to study the electrochemical responses of KET at Pp-ABSA/GCE and bare GCE. KET exhibited an irreversible oxidation peak at both modified and bare GCE. The anodic peak currents of KET on the Pp-ABSA/GCE were about 8 fold higher than that of the unmodified electrodes. The influence of various parameters on the Pp-ABSA/GCE was investigated. Under the optimized working conditions, the oxidation peak current is linear to the KET concentration in the ranges of 0.2–6.4 μM and 6.4– 22.48 μM with a detection limit of 0.36 μM. The Pp-ABSA/GCE has been successfully applied and validated by analyzing KET in blood and pharmaceutical samples.
- 31 March 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (6) , B193-B199
L- Cysteine Based Polymer Matrix Decorated with Au-Nanoparticles: As a Sensing Platform for Simultaneous Determination of Hydroquinone and Catechol
In the present study reported, fully electrochemical methodology was used to prepare a new nanocomposite on a glassy carbon electrode. Cysteic acid was formed by electrochemical oxidation of L-cysteine on the surface of a glassy carbon electrode (GCE) and used as a proper polymeric framework for deposition of Au nanoparticles (AuNPs). Field emission scanning electron microscopy (FESEM) was used for the surface characterization. It was shown that this composite electrode not only separates the voltammetric signals of hydroquinone (HQ) and catechol (CC), but also shows higher oxidation current for these molecules. Under the optimized condition, a linear dynamic range of 0.09 μmol dm−3 to 39.2 μmol dm−3 range for hydroquinone with the detection limit of 20 nM and from 0.09 μmol dm−3 to 39.2 μmol dm−3 for catechol with the detection limit of 60 nM were obtained. The proposed method was evaluated by determination of HQ and CC in rain and tap water samples with satisfactory results (recovery > 96%).
- 31 March 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (6) , B193-B199
L- Cysteine Based Polymer Matrix Decorated with Au-Nanoparticles: As a Sensing Platform for Simultaneous Determination of Hydroquinone and Catechol
In the present study reported, fully electrochemical methodology was used to prepare a new nanocomposite on a glassy carbon electrode. Cysteic acid was formed by electrochemical oxidation of L-cysteine on the surface of a glassy carbon electrode (GCE) and used as a proper polymeric framework for deposition of Au nanoparticles (AuNPs). Field emission scanning electron microscopy (FESEM) was used for the surface characterization. It was shown that this composite electrode not only separates the voltammetric signals of hydroquinone (HQ) and catechol (CC), but also shows higher oxidation current for these molecules. Under the optimized condition, a linear dynamic range of 0.09 μmol dm−3 to 39.2 μmol dm−3 range for hydroquinone with the detection limit of 20 nM and from 0.09 μmol dm−3 to 39.2 μmol dm−3 for catechol with the detection limit of 60 nM were obtained. The proposed method was evaluated by determination of HQ and CC in rain and tap water samples with satisfactory results (recovery > 96%).
- 1 March 2017
- Published by American Scientific Publishers in Sensor Letters
- Vol. 15 (3) , 282-288
Applications of Polymer and Nanoscale Carbon-Based Materials in Piroxicam Sensing and Detection
In this paper, a new and convenient electrochemical sensor for detection of piroxicam (PXM) by differential pulse voltammetry (DPV) is presented. This sensor was fabricated by dripping welldispersed MWCNTs onto glassy carbon electrode (GCE) surface firstly, and then poly(L-arginine) film were subsequently electropolymerized on it to prepare P-L-Arg/MWCNTs/GCE. The surface morphology of the electrodes has been studied by scanning electron microscopy. Studies reveal that the irreversible oxidation of PXM was highly facile on P-L-Arg/MWCNTs/GCE. The dynamic detection range of this sensor to PXM was 0.49 μmol L–1 to 3.9 μmol L–1, with the detection limit of 0.34 μmol L–1. A new voltammetric method for determination of PXM was erected and shows good sensitivity and selectivity, very easy surface update and good stability. The analytical application of the modified electrode is demonstrated by determining PXM in pharmaceutical formulations and biological fluids (serum).
- 1 March 2017
- Published by American Scientific Publishers in Sensor Letters
- Vol. 15 (3) , 282-288
Applications of Polymer and Nanoscale Carbon-Based Materials in Piroxicam Sensing and Detection
In this paper, a new and convenient electrochemical sensor for detection of piroxicam (PXM) by differential pulse voltammetry (DPV) is presented. This sensor was fabricated by dripping welldispersed MWCNTs onto glassy carbon electrode (GCE) surface firstly, and then poly(L-arginine) film were subsequently electropolymerized on it to prepare P-L-Arg/MWCNTs/GCE. The surface morphology of the electrodes has been studied by scanning electron microscopy. Studies reveal that the irreversible oxidation of PXM was highly facile on P-L-Arg/MWCNTs/GCE. The dynamic detection range of this sensor to PXM was 0.49 μmol L–1 to 3.9 μmol L–1, with the detection limit of 0.34 μmol L–1. A new voltammetric method for determination of PXM was erected and shows good sensitivity and selectivity, very easy surface update and good stability. The analytical application of the modified electrode is demonstrated by determining PXM in pharmaceutical formulations and biological fluids (serum).