Ivana Abramovic
Research Subjects
Ivana Abramovic has a total of 654 co-authors. Here are the top co-authors by number of shared publications:
D. Moseev
Max-Planck Institut fur Plasma Physik 3 , Wendelsteinstraße 1, D-17491 Greifswald, Germany
6 shared publications- Mirko Salewski
Department of Physics, Technical University of Denmark, Lyngby, Denmark
5 shared publications - Massimo Nocente
Department of Physics, University of Milano-Bicocca 1 , Milan 20126
4 shared publications - Aaron Michael Rosenthal
Commonwealth Fusion Systems 2 , Devens, Massachusetts 01434
3 shared publications - Clayton Edward Myers
Commonwealth Fusion Systems , Devens, Massachusetts 01434
3 shared publications - Ella Fox-Widdows
Commonwealth Fusion Systems , Devens, Massachusetts 01434
3 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Measurements for fusion power to demonstrate Q fus > 1 on SPARC (invited)
The SPARC tokamak’s primary goal in the first operational campaign is achieving net fusion energy gain (Qfus> 1), targeting a fusion power (Pfus) of 8–30 MW in deuterium–tritium (DT) plasma. For an optimally accurate and widely accepted demonstration of breakeven, the SPARC team is preparing for three independent methodologies to measure Pfus. The first method relies on neutron flux monitors and a neutron activation system, which together offer high time-resolution data using ionization chambers and dosimetry foils for absolute yield measurements. These are calibrated via an in situ DT neutron generator and detailed neutronics models. The second method employs collimated neutron diagnostics. A core-viewing magnetic-proton recoil spectrometer analyzes the neutron energy spectrum, while a poloidal profiler uses scintillator and diamond detectors to derive the DT neutron emissivity profile. Together, these diagnostics allow for a precise reconstruction of Pfus from core emissions. The third method calculates Pfus by volume-integrating the fusion reactivity using data from an array of kinetic profile diagnostics. Key inputs include temperature profiles from x-ray spectroscopy and electron–cyclotron emission measurements, plasma/electron density from Thomson-scattering, interferometry and edge-reflectometry, and fuel ion and impurity levels (Zeff) from optical and vacuum-UV spectroscopy. Neutral gas diagnostics and optical spectroscopy provide the critical fuel ion concentrations, which are also needed for corrections for the non-DT neutron contributions. By integrating these complementary techniques, SPARC ensures a robust and verified demonstration of Qfus > 1 in its first campaign.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Open AccessMeasurements for fusion power to demonstrate Q fus > 1 on SPARC (invited)
The SPARC tokamak’s primary goal in the first operational campaign is achieving net fusion energy gain (Qfus> 1), targeting a fusion power (Pfus) of 8–30 MW in deuterium–tritium (DT) plasma. For an optimally accurate and widely accepted demonstration of breakeven, the SPARC team is preparing for three independent methodologies to measure Pfus. The first method relies on neutron flux monitors and a neutron activation system, which together offer high time-resolution data using ionization chambers and dosimetry foils for absolute yield measurements. These are calibrated via an in situ DT neutron generator and detailed neutronics models. The second method employs collimated neutron diagnostics. A core-viewing magnetic-proton recoil spectrometer analyzes the neutron energy spectrum, while a poloidal profiler uses scintillator and diamond detectors to derive the DT neutron emissivity profile. Together, these diagnostics allow for a precise reconstruction of Pfus from core emissions. The third method calculates Pfus by volume-integrating the fusion reactivity using data from an array of kinetic profile diagnostics. Key inputs include temperature profiles from x-ray spectroscopy and electron–cyclotron emission measurements, plasma/electron density from Thomson-scattering, interferometry and edge-reflectometry, and fuel ion and impurity levels (Zeff) from optical and vacuum-UV spectroscopy. Neutral gas diagnostics and optical spectroscopy provide the critical fuel ion concentrations, which are also needed for corrections for the non-DT neutron contributions. By integrating these complementary techniques, SPARC ensures a robust and verified demonstration of Qfus > 1 in its first campaign.
- Open Access
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Synthetic measurements of runaway electron synchrotron emission in the SPARC tokamak
With plasma currents up to 8.7 MA, the SPARC tokamak runs the risk of forming multi-MA beams of relativistic “runaway” electrons (REs), which could damage plasma facing components if unmitigated. The infrared (IR) and visible imaging and visible spectroscopy systems in SPARC are designed with measurements of synchrotron emission from REs in mind. Synchrotron radiation is emitted by REs along their direction of motion, opposite the plasma current. Matched clockwise and counterclockwise wide views are proposed to detect synchrotron and background radiation, allowing observation of RE synchrotron emission in both plasma current configurations. Due to SPARC’s high toroidal magnetic field strength, 12.2 T on axis, the synchrotron light spectrum is expected to peak in the visible-IR wavelength range. The synthetic diagnostic tool, Synchrotron Orbit-Following Toolkit, is used to model synchrotron images and spectra for three scenarios, with appropriate magnetic equilibria for each: REs generated during plasma current ramp-up, steady-state flat-top (although unlikely, but serving as a reference), and disruptions. Required time resolutions, achievable spatial coverage, and appropriate spectral ranges for various RE energies are assessed.
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Open AccessSynthetic measurements of runaway electron synchrotron emission in the SPARC tokamak
With plasma currents up to 8.7 MA, the SPARC tokamak runs the risk of forming multi-MA beams of relativistic “runaway” electrons (REs), which could damage plasma facing components if unmitigated. The infrared (IR) and visible imaging and visible spectroscopy systems in SPARC are designed with measurements of synchrotron emission from REs in mind. Synchrotron radiation is emitted by REs along their direction of motion, opposite the plasma current. Matched clockwise and counterclockwise wide views are proposed to detect synchrotron and background radiation, allowing observation of RE synchrotron emission in both plasma current configurations. Due to SPARC’s high toroidal magnetic field strength, 12.2 T on axis, the synchrotron light spectrum is expected to peak in the visible-IR wavelength range. The synthetic diagnostic tool, Synchrotron Orbit-Following Toolkit, is used to model synchrotron images and spectra for three scenarios, with appropriate magnetic equilibria for each: REs generated during plasma current ramp-up, steady-state flat-top (although unlikely, but serving as a reference), and disruptions. Required time resolutions, achievable spatial coverage, and appropriate spectral ranges for various RE energies are assessed.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy. SPARC’s first campaign plan is to achieve Qfus > 1 using an ICRF-heated, 15 m from the center of the tokamak, on the other side of a 2.4 m concrete shielding wall. A series of 31 large-scale penetrations have been included in the SPARC Tokamak Hall to facilitate integration of early campaign diagnostics and to provide upgradability.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessOverview of the early campaign diagnostics for the SPARC tokamak (invited)
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy. SPARC’s first campaign plan is to achieve Qfus > 1 using an ICRF-heated, 15 m from the center of the tokamak, on the other side of a 2.4 m concrete shielding wall. A series of 31 large-scale penetrations have been included in the SPARC Tokamak Hall to facilitate integration of early campaign diagnostics and to provide upgradability.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Development of a bolometry diagnostic for SPARC
To control and optimize the power of the SPARC tokamak, we require information on the total radiated power of the plasma and its 2D and 3D spatial distribution. The SPARC bolometry diagnostic is being designed and built to measure the radiated power for controlling power balance, investigating the dissipation capabilities of various divertor concepts, and measuring the efficacy of the disruption thermal load mitigation. Proven resistive bolometer sensor technology will be used, with 248 lines of sight integrated into pinhole cameras in 20 different locations. This diversity of views will allow the bolometers to view the core, divertor, and particularly X-points of the plasma with high resolution. 14 of these camera locations are dedicated to 2D equilibrium radiated power, while the remaining six locations are designed to measure 3D radiated energy during disruptions. The bolometer sensor holders, pinhole camera boxes, and cabling have been designed to survive the high neutron flux (but low fluence) and up to 400 °C temperatures seen during operation and vacuum bake. The resistive bolometer sensors use Au absorbers with an Al heat conduction layer and C anti-reflective layer. These sensor chips are wire-bonded to an AlN circuit board, both of which are held inside a custom AlN and stainless steel bolometer holder. Design and optimization of the pinhole camera lines of sight are performed using Cherab. This work details the current state of the design of the SPARC bolometry diagnostic and its interfaces, as well as ongoing work to validate the design.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Development of a bolometry diagnostic for SPARC
To control and optimize the power of the SPARC tokamak, we require information on the total radiated power of the plasma and its 2D and 3D spatial distribution. The SPARC bolometry diagnostic is being designed and built to measure the radiated power for controlling power balance, investigating the dissipation capabilities of various divertor concepts, and measuring the efficacy of the disruption thermal load mitigation. Proven resistive bolometer sensor technology will be used, with 248 lines of sight integrated into pinhole cameras in 20 different locations. This diversity of views will allow the bolometers to view the core, divertor, and particularly X-points of the plasma with high resolution. 14 of these camera locations are dedicated to 2D equilibrium radiated power, while the remaining six locations are designed to measure 3D radiated energy during disruptions. The bolometer sensor holders, pinhole camera boxes, and cabling have been designed to survive the high neutron flux (but low fluence) and up to 400 °C temperatures seen during operation and vacuum bake. The resistive bolometer sensors use Au absorbers with an Al heat conduction layer and C anti-reflective layer. These sensor chips are wire-bonded to an AlN circuit board, both of which are held inside a custom AlN and stainless steel bolometer holder. Design and optimization of the pinhole camera lines of sight are performed using Cherab. This work details the current state of the design of the SPARC bolometry diagnostic and its interfaces, as well as ongoing work to validate the design.
- Open Access
- 14 December 2022
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 88 (6) , 895880604
Data-driven model discovery for plasma turbulence modelling
An important problem in nuclear fusion plasmas is the prediction and control of turbulence which drives the cross-field transport, thus leading to energy loss from the system and deteriorating confinement. Turbulence, being a highly nonlinear and multiscale process, is challenging to theoretically describe and computationally model. Most advanced computational models fall into one of the two categories: fluid or gyro-kinetic. They both come at a high computational cost and cannot be applied for routine simulation of plasma discharge evolution and control. Development of reduced models based on (physics informed) artificial neural networks could potentially fulfil the need for affordable simulations of plasma turbulence. However, the training requires an extensive data base and the obtained models lack extrapolation capability to scenarios not originally encountered during training. This leads to reduced models of limited validity which may not prove adequate for predicting scenarios in future machines. In contrast, we explore a data-driven model discovery approach based on sparse regression to infer governing nonlinear partial differential equations directly from the data. Our input data are generated by simulations of drift-wave turbulence according to the Hasegawa–Wakatani and modified Hasegawa–Wakatani models. Balancing model accuracy and complexity enables the reconstruction of the systems of partial differential equations accurately describing the dynamics simulated in the input data sets. Sparse regression is not data hungry and can be extrapolated to unexplored parameter ranges. We explore and demonstrate the potential of this approach for fusion plasma turbulence modelling. The findings show that the methodology is promising for the development of reduced and computationally efficient turbulence models as well as for existing model cross-validation.
- 14 December 2022
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 88 (6) , 895880604
Open AccessData-driven model discovery for plasma turbulence modelling
An important problem in nuclear fusion plasmas is the prediction and control of turbulence which drives the cross-field transport, thus leading to energy loss from the system and deteriorating confinement. Turbulence, being a highly nonlinear and multiscale process, is challenging to theoretically describe and computationally model. Most advanced computational models fall into one of the two categories: fluid or gyro-kinetic. They both come at a high computational cost and cannot be applied for routine simulation of plasma discharge evolution and control. Development of reduced models based on (physics informed) artificial neural networks could potentially fulfil the need for affordable simulations of plasma turbulence. However, the training requires an extensive data base and the obtained models lack extrapolation capability to scenarios not originally encountered during training. This leads to reduced models of limited validity which may not prove adequate for predicting scenarios in future machines. In contrast, we explore a data-driven model discovery approach based on sparse regression to infer governing nonlinear partial differential equations directly from the data. Our input data are generated by simulations of drift-wave turbulence according to the Hasegawa–Wakatani and modified Hasegawa–Wakatani models. Balancing model accuracy and complexity enables the reconstruction of the systems of partial differential equations accurately describing the dynamics simulated in the input data sets. Sparse regression is not data hungry and can be extrapolated to unexplored parameter ranges. We explore and demonstrate the potential of this approach for fusion plasma turbulence modelling. The findings show that the methodology is promising for the development of reduced and computationally efficient turbulence models as well as for existing model cross-validation.
- Open Access
- 1 March 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (3) , 035252
Collective Thomson scattering model for arbitrarily drifting bi-Maxwellian velocity distributions
In this paper we derive the equations of collective Thomson scattering (CTS) for an arbitrarily drifting magnetized plasma described by a bi-Maxwellian distribution. The model allows the treatment of anisotropic plasma with different parallel and perpendicular temperatures (with respect to the magnetic field) as well as parallel and perpendicular plasma drift. As could be expected, parallel observation directions are most sensitive to the parallel temperature and drift, whereas perpendicular observation directions are most sensitive to the perpendicular temperature and the perpendicular drift along the observation direction. The perpendicular drift can be related to the radial electric field. Measurements with a spectral resolution better than 0.5 MHz are necessary for the inference of the radial electric field. This spectral resolution and the required scattering geometry are attainable with the current setup of the CTS diagnostic on Wendelstein 7-X.
- 1 March 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (3) , 035252
Open AccessCollective Thomson scattering model for arbitrarily drifting bi-Maxwellian velocity distributions
In this paper we derive the equations of collective Thomson scattering (CTS) for an arbitrarily drifting magnetized plasma described by a bi-Maxwellian distribution. The model allows the treatment of anisotropic plasma with different parallel and perpendicular temperatures (with respect to the magnetic field) as well as parallel and perpendicular plasma drift. As could be expected, parallel observation directions are most sensitive to the parallel temperature and drift, whereas perpendicular observation directions are most sensitive to the perpendicular temperature and the perpendicular drift along the observation direction. The perpendicular drift can be related to the radial electric field. Measurements with a spectral resolution better than 0.5 MHz are necessary for the inference of the radial electric field. This spectral resolution and the required scattering geometry are attainable with the current setup of the CTS diagnostic on Wendelstein 7-X.
- 1 February 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (2) , 023501
Forward modeling of collective Thomson scattering for Wendelstein 7-X plasmas: Electrostatic approximation
In this paper, we present a method for numerical computation of collective Thomson scattering (CTS). We developed a forward model, eCTS, in the electrostatic approximation and benchmarked it against a full electromagnetic model. Differences between the electrostatic and the electromagnetic models are discussed. The sensitivity of the results to the ion temperature and the plasma composition is demonstrated. We integrated the model into the Bayesian data analysis framework Minerva and used it for the analysis of noisy synthetic data sets produced by a full electromagnetic model. It is shown that eCTS can be used for the inference of the bulk ion temperature. The model has been used to infer the bulk ion temperature from the first CTS measurements on Wendelstein 7-X.
- 1 February 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (2) , 023501
Forward modeling of collective Thomson scattering for Wendelstein 7-X plasmas: Electrostatic approximation
In this paper, we present a method for numerical computation of collective Thomson scattering (CTS). We developed a forward model, eCTS, in the electrostatic approximation and benchmarked it against a full electromagnetic model. Differences between the electrostatic and the electromagnetic models are discussed. The sensitivity of the results to the ion temperature and the plasma composition is demonstrated. We integrated the model into the Bayesian data analysis framework Minerva and used it for the analysis of noisy synthetic data sets produced by a full electromagnetic model. It is shown that eCTS can be used for the inference of the bulk ion temperature. The model has been used to infer the bulk ion temperature from the first CTS measurements on Wendelstein 7-X.
- 1 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (8) , 083507
Fast analysis of collective Thomson scattering spectra on Wendelstein 7-X
Two methods for fast analysis of Collective Thomson Scattering (CTS) spectra are presented: Function Parametrization (FP) and feedforward Artificial Neural Networks (ANNs). At this time, a CTS diagnostic is being commissioned at the Wendelstein 7-X (W7-X) stellarator, with ion temperature measurements in the plasma core as its primary goal. A mapping was made from a database of simulated CTS spectra to the corresponding ion and electron temperatures (Ti and Te). The mean absolute mapping errors are 4.2% and 9.9% relative to the corresponding Ti, for the ANN and FP, respectively, for spectra with Gaussian noise equivalent to 10% of the average of the spectral maxima in the database at 650 sampling points per GHz and within a limited parameter space. Although FP provides some insight into the information contents of the CTS spectra, ANNs provide a higher accuracy and noise robustness, are easier to implement, and are more adaptable to a larger parameter space. These properties make ANN mappings a promising all-round method for fast CTS data analysis. Addition of impurity concentrations to the current parameter space will enable fast bulk ion temperature measurements in the plasma core region of W7-X.
- 1 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (8) , 083507
Fast analysis of collective Thomson scattering spectra on Wendelstein 7-X
Two methods for fast analysis of Collective Thomson Scattering (CTS) spectra are presented: Function Parametrization (FP) and feedforward Artificial Neural Networks (ANNs). At this time, a CTS diagnostic is being commissioned at the Wendelstein 7-X (W7-X) stellarator, with ion temperature measurements in the plasma core as its primary goal. A mapping was made from a database of simulated CTS spectra to the corresponding ion and electron temperatures (Ti and Te). The mean absolute mapping errors are 4.2% and 9.9% relative to the corresponding Ti, for the ANN and FP, respectively, for spectra with Gaussian noise equivalent to 10% of the average of the spectral maxima in the database at 650 sampling points per GHz and within a limited parameter space. Although FP provides some insight into the information contents of the CTS spectra, ANNs provide a higher accuracy and noise robustness, are easier to implement, and are more adaptable to a larger parameter space. These properties make ANN mappings a promising all-round method for fast CTS data analysis. Addition of impurity concentrations to the current parameter space will enable fast bulk ion temperature measurements in the plasma core region of W7-X.
- 10 July 2018
- Published by IOP Publishing in Nuclear Fusion
- Vol. 58 (9) , 096019
Alpha-particle velocity-space diagnostic in ITER
- 10 July 2018
- Published by IOP Publishing in Nuclear Fusion
- Vol. 58 (9) , 096019
Alpha-particle velocity-space diagnostic in ITER
- Open Access
- 1 February 2018
- Published by IOP Publishing in Nuclear Fusion
- Vol. 58 (3) , 036017
Deuterium temperature, drift velocity, and density measurements in non-Maxwellian plasmas at ASDEX Upgrade
- 1 February 2018
- Published by IOP Publishing in Nuclear Fusion
- Vol. 58 (3) , 036017
Open AccessDeuterium temperature, drift velocity, and density measurements in non-Maxwellian plasmas at ASDEX Upgrade