Hossein Abdolmohammad-Zadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hossein Abdolmohammad-Zadeh has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Elaheh Rahimpour
Pharmaceutical Analysis Research Center, Pharmaceutical Sciences Institute, Tabriz University of Medical Sciences, Tabriz, Iran
8 shared publications Zeynab Talleb
Research and Development Department, Zahravi Pharmaceutical Company, Tabriz, Iran
7 shared publicationsG.H. Sadeghi
5 shared publications- Mohammad Amjadi
Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
4 shared publications - Abbasali Zamani
Environmental Science Research Laboratory, Department of Environmental Science, Faculty of Science, University of Zanjan, Zanjan, Iran
3 shared publications Abulghasem Jouyban
3 shared publications
Latest Publications
- 20 December 2025
- Published by Springer Nature in Chemical Papers
- Vol. 80 (3) , 2983-2996
An efficient DMSPE technique based on magnetite/clinoptilolite zeolite nanocomposite for the pre-concentration of triptorelin in urine samples
- 20 December 2025
- Published by Springer Nature in Chemical Papers
- Vol. 80 (3) , 2983-2996
An efficient DMSPE technique based on magnetite/clinoptilolite zeolite nanocomposite for the pre-concentration of triptorelin in urine samples
- 4 December 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (47) , 9599-9607
A fluorescent sensor based on a silicon quantum dots/chitosan nanocomposite for tetracycline monitoring in serum samples
Schematic of the silicon quantum dots (SiQDs)/chitosan (CS) nanocomposite synthesis and spectrofluorometric detection of tetracycline (TC) using the novel “on–off” fluorescent nano-probe based on the synthesized SiQDs/CS nanocomposite.
- 4 December 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (47) , 9599-9607
A fluorescent sensor based on a silicon quantum dots/chitosan nanocomposite for tetracycline monitoring in serum samples
Schematic of the silicon quantum dots (SiQDs)/chitosan (CS) nanocomposite synthesis and spectrofluorometric detection of tetracycline (TC) using the novel “on–off” fluorescent nano-probe based on the synthesized SiQDs/CS nanocomposite.
- 16 October 2024
- Published by Elsevier
- p. 653-665
Membrane-based extraction techniques in food analysis
- 26 January 2023
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (6) , 1257-1270
A magnetic nano-biocomposite based on calcined Ni–Fe layered double hydroxide and chitosan as an adsorbent for cadmium(II)
- 26 January 2023
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (6) , 1257-1270
A magnetic nano-biocomposite based on calcined Ni–Fe layered double hydroxide and chitosan as an adsorbent for cadmium(II)
- 6 October 2022
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (2) , 389-397
Photocatalytic degradation of Indigo Carmine using aluminum-doped titanium dioxide/zinc ferrite nanocomposite under visible light
- 6 October 2022
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (2) , 389-397
Photocatalytic degradation of Indigo Carmine using aluminum-doped titanium dioxide/zinc ferrite nanocomposite under visible light
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
A Chemiluminescence Biosensor for Indirect Detection of Diazinon Using Molybdenum Disulfide/Zirconium Metal-Organic Framework Nanocomposite
In this research, a biosensor was introduced for indirect detection of diazinon using a molybdenum disulfide/zirconium metal-organic framework nanocomposite (MoS2@MIP-202(Zr)). The probe is based on the high peroxidase-like activity of the MoS2@MIP-202(Zr) nanocomposite on NaHCO3-H2O2 chemiluminescence system as well as the inhibitory effect of diazinon on enzymatic activity of acetylcholinesterase (AchE). In the presence of diazinon, AChE cannot effectively catalyze the breakdown of acetylcholine into choline, so the resulted H2O2 from choline oxidation is decreased, leading to diminish in the chemiluminescence signal. The analytical signal is gradually decreased with increase in diazinon concentration, and there is a linear relationship between the signal and diazinon concentration. Accordingly, after synthesis and characterization of MoS2@MIP-202(Zr) nanocomposite, it was employed as a green, cost-effective and easy probe for indirect detection of diazinon. In the optimal condition, the calibration graph was linear in the concentration range of 0.5‒300.0 nmol L−1. The limit of detection and limit of quantification of the method are 0.12 and 0.40 nmol L−1, respectively. The intra-day and inter-day relative standard deviations (% RSD n=5, diazinon concentration; 100 nmol L‒1) are 1.35 and 3.66%, respectively. The method was used for diazinon detection in water samples, and the relative recovery values between 95.0 and 102.5% were achieved for the spiked samples.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Chemiluminescence Biosensor for Indirect Detection of Diazinon Using Molybdenum Disulfide/Zirconium Metal-Organic Framework Nanocomposite
In this research, a biosensor was introduced for indirect detection of diazinon using a molybdenum disulfide/zirconium metal-organic framework nanocomposite (MoS2@MIP-202(Zr)). The probe is based on the high peroxidase-like activity of the MoS2@MIP-202(Zr) nanocomposite on NaHCO3-H2O2 chemiluminescence system as well as the inhibitory effect of diazinon on enzymatic activity of acetylcholinesterase (AchE). In the presence of diazinon, AChE cannot effectively catalyze the breakdown of acetylcholine into choline, so the resulted H2O2 from choline oxidation is decreased, leading to diminish in the chemiluminescence signal. The analytical signal is gradually decreased with increase in diazinon concentration, and there is a linear relationship between the signal and diazinon concentration. Accordingly, after synthesis and characterization of MoS2@MIP-202(Zr) nanocomposite, it was employed as a green, cost-effective and easy probe for indirect detection of diazinon. In the optimal condition, the calibration graph was linear in the concentration range of 0.5‒300.0 nmol L−1. The limit of detection and limit of quantification of the method are 0.12 and 0.40 nmol L−1, respectively. The intra-day and inter-day relative standard deviations (% RSD n=5, diazinon concentration; 100 nmol L‒1) are 1.35 and 3.66%, respectively. The method was used for diazinon detection in water samples, and the relative recovery values between 95.0 and 102.5% were achieved for the spiked samples.