Jan Odstrcilik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jan Odstrcilik has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Radim Kolar
Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication Brno University of Technology Brno Czech Republic
15 shared publications J. Jan
Brno University of Technology
4 shared publicationsJiri Gazarek
Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 61600, Czech Republic
4 shared publicationsJiri Jan
Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 61600, Czech Republic
4 shared publicationsAttila Budai
Pattern Recognition Lab and Erlangen Graduate School of Advanced Optical Technologies, University of Erlangen - Nuremberg, Martensstrase 3, 91058 Erlangen, Germany
3 shared publications- Ivo Provaznik
Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic
3 shared publications
Latest Publications
- Open Access
- 5 May 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (5) , e0284743
Comparative analysis of retinal photoplethysmographic spatial maps and thickness of retinal nerve fiber layer
The paper presents a comparative study of the pulsatile attenuation amplitude (PAA) within the optic nerve head (ONH) at four different areas calculated from retinal video sequences and its relevance to the retinal nerve fiber layer thickness (RNFL) changes in normal subjects and patients with different stages of glaucoma. The proposed methodology utilizes processing of retinal video sequences acquired by a novel video ophthalmoscope. The PAA parameter measures the amplitude of heartbeat-modulated light attenuation in retinal tissue. Correlation analysis between PAA and RNFL is performed in vessel-free locations of the peripapillary region with the proposed evaluating patterns: 360° circular area, temporal semi-circle, nasal semi-circle. For comparison, the full ONH area is also included. Various positions and sizes of evaluating patterns in peripapillary region were tested which resulted in different outputs of correlation analysis. The results show significant correlation between PAA and RNFL thickness calculated in proposed areas. The highest correlation coefficient Rtemp = 0.557 (pRnasal = 0.332, p<0.001). Furthermore, the results indicate the most relevant approach to calculate PAA from the acquired video sequences is using a thin annulus near the ONH center. Finally, the paper shows the proposed photoplethysmographic principle based on innovative video ophthalmoscope can be used to analyze changes in retinal perfusion in peripapillary area and can be potentially used to assess progression of the RNFL deterioration.
- 5 May 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (5) , e0284743
Open AccessComparative analysis of retinal photoplethysmographic spatial maps and thickness of retinal nerve fiber layer
The paper presents a comparative study of the pulsatile attenuation amplitude (PAA) within the optic nerve head (ONH) at four different areas calculated from retinal video sequences and its relevance to the retinal nerve fiber layer thickness (RNFL) changes in normal subjects and patients with different stages of glaucoma. The proposed methodology utilizes processing of retinal video sequences acquired by a novel video ophthalmoscope. The PAA parameter measures the amplitude of heartbeat-modulated light attenuation in retinal tissue. Correlation analysis between PAA and RNFL is performed in vessel-free locations of the peripapillary region with the proposed evaluating patterns: 360° circular area, temporal semi-circle, nasal semi-circle. For comparison, the full ONH area is also included. Various positions and sizes of evaluating patterns in peripapillary region were tested which resulted in different outputs of correlation analysis. The results show significant correlation between PAA and RNFL thickness calculated in proposed areas. The highest correlation coefficient Rtemp = 0.557 (pRnasal = 0.332, p<0.001). Furthermore, the results indicate the most relevant approach to calculate PAA from the acquired video sequences is using a thin annulus near the ONH center. Finally, the paper shows the proposed photoplethysmographic principle based on innovative video ophthalmoscope can be used to analyze changes in retinal perfusion in peripapillary area and can be potentially used to assess progression of the RNFL deterioration.
- 2 June 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (9) , e202200094
Multispectral retinal video‐ophthalmoscope with fiber optic illumination
Multispectral imaging is used in various applications including astronomy, industry and agriculture. In retinal imaging, the single‐shot multispectral image stack is typically acquired and analyzed. This multispectral analysis can provide information on various structural or metabolic properties. This paper describes the multispectral improvement of a video‐ophthalmoscope, which can acquire retinal video sequences of the optic nerve head and peripapillary area using various spectral light illumination. The description of the multispectral video imaging is provided and several applications are described. These applications include multispectral retinal photoplethysmography, visualization of spontaneous vein pulsation and multispectral RGB image generation.
- 2 June 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (9) , e202200094
Multispectral retinal video‐ophthalmoscope with fiber optic illumination
Multispectral imaging is used in various applications including astronomy, industry and agriculture. In retinal imaging, the single‐shot multispectral image stack is typically acquired and analyzed. This multispectral analysis can provide information on various structural or metabolic properties. This paper describes the multispectral improvement of a video‐ophthalmoscope, which can acquire retinal video sequences of the optic nerve head and peripapillary area using various spectral light illumination. The description of the multispectral video imaging is provided and several applications are described. These applications include multispectral retinal photoplethysmography, visualization of spontaneous vein pulsation and multispectral RGB image generation.
- Open Access
- 22 September 2020
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 259 (2) , 483-494
Imaging video plethysmography shows reduced signal amplitude in glaucoma patients in the area of the microvascular tissue of the optic nerve head
Purpose: To measure parameters of the cardiac cycle-induced pulsatile light absorption signal (plethysmography signal) of the optic nerve head (ONH) and to compare parameters between normal subjects and patients with different stages of glaucoma. Patients and methods: A recently developed video ophthalmoscope was used to acquire short video sequences (10 s) of the ONH. After image registration and trend correction, the pulsatile changing light absorption at the ONH tissue (excluding large vessels) was calculated. The changing light absorption depends on the pulsatile changing blood volume. Various parameters, including peak amplitude, steepness, time-to-peak, full width at half maximum (FWHM), and pulse duration, were calculated for averaged individual pulses (heartbeats) of the plethysmography signal. This method was applied to 19 healthy control subjects and 91 subjects with ocular hypertension, as well as different stages of primary open-angle glaucoma (17 subjects with ocular hypertension, 24 with preperimetric glaucoma, and 50 with perimetric glaucoma). Results: Compared to the normal subjects, significant reductions (p < 0.001) in peak amplitude and steepness were observed in the group of perimetric glaucoma patients, but no significant difference was found for time-to-peak, FWHM, and pulse duration. Peak amplitude and steepness showed high correlations with RNFL thickness (p < 0.001). Conclusions: The presented low-cost video-ophthalmoscope permits measurement of the plethysmographic signal of the ONH tissue and calculation of different blood flow-related parameters. The reduced values of the amplitude and steepness parameters in perimetric glaucoma patients suggest decreased ONH perfusion and blood volume. This outcome is in agreement with results from other studies using OCT angiography and laser speckle flowgraphy, which confirm reduced capillary density in these patients. Registration site: www.clinicaltrials.gov, Trial registration number: NCT00494923
- 22 September 2020
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 259 (2) , 483-494
Open AccessImaging video plethysmography shows reduced signal amplitude in glaucoma patients in the area of the microvascular tissue of the optic nerve head
Purpose: To measure parameters of the cardiac cycle-induced pulsatile light absorption signal (plethysmography signal) of the optic nerve head (ONH) and to compare parameters between normal subjects and patients with different stages of glaucoma. Patients and methods: A recently developed video ophthalmoscope was used to acquire short video sequences (10 s) of the ONH. After image registration and trend correction, the pulsatile changing light absorption at the ONH tissue (excluding large vessels) was calculated. The changing light absorption depends on the pulsatile changing blood volume. Various parameters, including peak amplitude, steepness, time-to-peak, full width at half maximum (FWHM), and pulse duration, were calculated for averaged individual pulses (heartbeats) of the plethysmography signal. This method was applied to 19 healthy control subjects and 91 subjects with ocular hypertension, as well as different stages of primary open-angle glaucoma (17 subjects with ocular hypertension, 24 with preperimetric glaucoma, and 50 with perimetric glaucoma). Results: Compared to the normal subjects, significant reductions (p < 0.001) in peak amplitude and steepness were observed in the group of perimetric glaucoma patients, but no significant difference was found for time-to-peak, FWHM, and pulse duration. Peak amplitude and steepness showed high correlations with RNFL thickness (p < 0.001). Conclusions: The presented low-cost video-ophthalmoscope permits measurement of the plethysmographic signal of the ONH tissue and calculation of different blood flow-related parameters. The reduced values of the amplitude and steepness parameters in perimetric glaucoma patients suggest decreased ONH perfusion and blood volume. This outcome is in agreement with results from other studies using OCT angiography and laser speckle flowgraphy, which confirm reduced capillary density in these patients. Registration site: www.clinicaltrials.gov, Trial registration number: NCT00494923
- Open Access
- 20 May 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-17
Registration of retinal sequences from new video-ophthalmoscopic camera
Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.
- 20 May 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-17
Open AccessRegistration of retinal sequences from new video-ophthalmoscopic camera
Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.
- 3 December 2015
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 178 (6) , 1154-1166
Envisaging the Regulation of Alkaloid Biosynthesis and Associated Growth Kinetics in Hairy Roots of Vinca minor Through the Function of Artificial Neural Network
Artificial neural network based modeling is a generic approach to understand and correlate different complex parameters of biological systems for improving the desired output. In addition, some new inferences can also be predicted in a shorter time with less cost and labor. As terpenoid indole alkaloid pathway in Vinca minor is very less investigated or elucidated, a strategy of elicitation with hydroxylase and acetyltransferase along with incorporation of various precursors from primary shikimate and secoiridoid pools via simultaneous employment of cyclooxygenase inhibitor was performed in the hairy roots of V. minor. This led to the increment in biomass accumulation, total alkaloid concentration, and vincamine production in selected treatments. The resultant experimental values were correlated with algorithm approaches of artificial neural network that assisted in finding the yield of vincamine, alkaloids, and growth kinetics using number of elicits. The inputs were the hydroxylase/acetyltransferase elicitors and cyclooxygenase inhibitor along with various precursors from shikimate and secoiridoid pools and the outputs were growth index (GI), alkaloids, and vincamine. The approach incorporates two MATLAB codes; GRNN and FFBPNN. Growth kinetic studies revealed that shikimate and tryptophan supplementation triggers biomass accumulation (GI = 440.2 to 540.5); while maximum alkaloid (3.7 % dry wt.) and vincamine production (0.017 ± 0.001 % dry wt.) was obtained on supplementation of secologanin along with tryptophan, naproxen, hydrogen peroxide, and acetic anhydride. The study shows that experimental and predicted values strongly correlate each other. The correlation coefficient for growth index (GI), alkaloids, and vincamine was found to be 0.9997, 0.9980, 0.9511 in GRNN and 0.9725, 0.9444, 0.9422 in FFBPNN, respectively. GRNN provided greater similarity between the target and predicted dataset in comparison to FFBPNN. The findings can provide future insights to calculate growth index, alkaloids, and vincamine in combination to different elicits.
- 3 December 2015
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 178 (6) , 1154-1166
Envisaging the Regulation of Alkaloid Biosynthesis and Associated Growth Kinetics in Hairy Roots of Vinca minor Through the Function of Artificial Neural Network
Artificial neural network based modeling is a generic approach to understand and correlate different complex parameters of biological systems for improving the desired output. In addition, some new inferences can also be predicted in a shorter time with less cost and labor. As terpenoid indole alkaloid pathway in Vinca minor is very less investigated or elucidated, a strategy of elicitation with hydroxylase and acetyltransferase along with incorporation of various precursors from primary shikimate and secoiridoid pools via simultaneous employment of cyclooxygenase inhibitor was performed in the hairy roots of V. minor. This led to the increment in biomass accumulation, total alkaloid concentration, and vincamine production in selected treatments. The resultant experimental values were correlated with algorithm approaches of artificial neural network that assisted in finding the yield of vincamine, alkaloids, and growth kinetics using number of elicits. The inputs were the hydroxylase/acetyltransferase elicitors and cyclooxygenase inhibitor along with various precursors from shikimate and secoiridoid pools and the outputs were growth index (GI), alkaloids, and vincamine. The approach incorporates two MATLAB codes; GRNN and FFBPNN. Growth kinetic studies revealed that shikimate and tryptophan supplementation triggers biomass accumulation (GI = 440.2 to 540.5); while maximum alkaloid (3.7 % dry wt.) and vincamine production (0.017 ± 0.001 % dry wt.) was obtained on supplementation of secologanin along with tryptophan, naproxen, hydrogen peroxide, and acetic anhydride. The study shows that experimental and predicted values strongly correlate each other. The correlation coefficient for growth index (GI), alkaloids, and vincamine was found to be 0.9997, 0.9980, 0.9511 in GRNN and 0.9725, 0.9444, 0.9422 in FFBPNN, respectively. GRNN provided greater similarity between the target and predicted dataset in comparison to FFBPNN. The findings can provide future insights to calculate growth index, alkaloids, and vincamine in combination to different elicits.
- 14 October 2015
- Published by Taylor & Francis
- p. 95-100
Classification-based blood vessel segmentation in retinal images
- 14 October 2015
- Published by Taylor & Francis
- p. 95-100
Classification-based blood vessel segmentation in retinal images
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 961-964
Method for adult cardiomyocyte long-term viability monitoring using confocal microscopy techniques
Freshly isolated myocytes lose their viability and functionality very early, from single hours to single days. So their viability is usually tested before the experiments or monitored continuously in periodic time intervals. But simple observations using viability kits (e. g. LIVE / DEAD Cell Imaging Kit, Life Technologies) for this purpose are not sufficient because of Calcein photobleaching and furthermore repeated testing is not possible. In this paper we tested advanced methods based on Calcium degradation and fluorescence lifetime measurement or cardiomyocyte shape properties calculations.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 961-964
Method for adult cardiomyocyte long-term viability monitoring using confocal microscopy techniques
Freshly isolated myocytes lose their viability and functionality very early, from single hours to single days. So their viability is usually tested before the experiments or monitored continuously in periodic time intervals. But simple observations using viability kits (e. g. LIVE / DEAD Cell Imaging Kit, Life Technologies) for this purpose are not sufficient because of Calcein photobleaching and furthermore repeated testing is not possible. In this paper we tested advanced methods based on Calcium degradation and fluorescence lifetime measurement or cardiomyocyte shape properties calculations.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23258861,p. 453-456
Computer analysis of isolated cardiomyocyte contraction process via advanced image processing techniques
Isolated cardiomyocytes have been used as valid and useful model in experimental cardiology research for decades. The cell contraction function is usually measured via expensive and complex instruments which can either damage the cell or take much time for setting up. In contrary, recent development of optical microscopy and digital cameras suggests utilization of touch-less cardiomyocyte video acquisition in connection with advanced image processing techniques for evaluation of the cell contraction process. The proposed paper presents an automatic membrane detection method via computer processing of acquired video-sequences by utilization of an active contour model. Evaluation of detected cell area is used for estimation of cardiomyocyte contraction function. The method is evaluated utilizing the comparison with contraction measurement performed via atomic force microscopy technique.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23258861,p. 453-456
Computer analysis of isolated cardiomyocyte contraction process via advanced image processing techniques
Isolated cardiomyocytes have been used as valid and useful model in experimental cardiology research for decades. The cell contraction function is usually measured via expensive and complex instruments which can either damage the cell or take much time for setting up. In contrary, recent development of optical microscopy and digital cameras suggests utilization of touch-less cardiomyocyte video acquisition in connection with advanced image processing techniques for evaluation of the cell contraction process. The proposed paper presents an automatic membrane detection method via computer processing of acquired video-sequences by utilization of an active contour model. Evaluation of detected cell area is used for estimation of cardiomyocyte contraction function. The method is evaluated utilizing the comparison with contraction measurement performed via atomic force microscopy technique.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2015 (1094687X) , 5247-5250
Retinal image registration for eye movement estimation
This paper describes a novel methodology for eye fixation measurement using a unique videoophthalmoscope setup and advanced image registration approach. The representation of the eye movements via Poincare plot is also introduced. The properties, limitations and perspective of this methodology are finally discussed.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2015 (1094687X) , 5247-5250
Retinal image registration for eye movement estimation
This paper describes a novel methodology for eye fixation measurement using a unique videoophthalmoscope setup and advanced image registration approach. The representation of the eye movements via Poincare plot is also introduced. The properties, limitations and perspective of this methodology are finally discussed.
- 17 July 2015
- Published by SPIE-Intl Soc Optical Eng
- p. 954006-954006-6
Non-mydriatic video ophthalmoscope to measure fast temporal changes of the human retina
- 17 July 2015
- Published by SPIE-Intl Soc Optical Eng
- p. 954006-954006-6
Non-mydriatic video ophthalmoscope to measure fast temporal changes of the human retina