Gray Mullins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gray Mullins has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Kelly Costello
Department of Civil & Environmental Engineering, University of South Florida, Tampa, FL, USA
3 shared publications - Sarah Mobley
Department of Civil & Environmental Engineering, University of South Florida, Tampa, FL, USA
3 shared publications - Lucas Caliari de Lima
Univ. of South Florida
2 shared publications Rajan Sen
2 shared publications- Abla Zayed
Department of Civil & Environmental Engineering, University of South Florida, Tampa, FL 33620, USA
1 shared publication Amanda Lewis
Menard USA 2 , 1910 Cochran Rd., #900, Pittsburgh, PA 15220
1 shared publication
Latest Publications
- 30 June 2026
- Published by ASTM International in Geotechnical Testing Journal
- Vol. 49 (6)
Peak and Differential Temperature Estimation in Drilled Shafts Using Thermal Gradient Measurements
Temperature rise in curing concrete is a normal occurrence, but excessive temperatures can be detrimental to concrete strength and durability. Whereas high temperature concerns were once only anticipated in larger elements, the use of high-strength, high-cementitious content mix designs has shown that unsafe temperatures can develop in smaller elements as well. Although methods to predict the internal temperature distribution within foundation elements continue to evolve, current methods to determine when temperature limits have been exceeded are cumbersome, often involving cross-bracing or internal frameworks with embedded sensors that impede construction. This paper presents an innovative approach to predict peak and differential concrete temperatures in shafts using standard cage-based thermal integrity measurements; predictions are verified using data from sensors embedded in the concrete across the diameter of eight production drilled shafts. The proposed method addresses the gap between current mass concrete temperature specifications and the ability of practitioners to measure internal temperature to ensure compliance.
- 30 June 2026
- Published by ASTM International in Geotechnical Testing Journal
- Vol. 49 (6)
Peak and Differential Temperature Estimation in Drilled Shafts Using Thermal Gradient Measurements
Temperature rise in curing concrete is a normal occurrence, but excessive temperatures can be detrimental to concrete strength and durability. Whereas high temperature concerns were once only anticipated in larger elements, the use of high-strength, high-cementitious content mix designs has shown that unsafe temperatures can develop in smaller elements as well. Although methods to predict the internal temperature distribution within foundation elements continue to evolve, current methods to determine when temperature limits have been exceeded are cumbersome, often involving cross-bracing or internal frameworks with embedded sensors that impede construction. This paper presents an innovative approach to predict peak and differential concrete temperatures in shafts using standard cage-based thermal integrity measurements; predictions are verified using data from sensors embedded in the concrete across the diameter of eight production drilled shafts. The proposed method addresses the gap between current mass concrete temperature specifications and the ability of practitioners to measure internal temperature to ensure compliance.
- 1 February 2025
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 151 (2)
LRFD Resistance Factors for Base-Grouted Drilled Shafts in Cohesionless Soil
- 1 February 2025
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 151 (2)
LRFD Resistance Factors for Base-Grouted Drilled Shafts in Cohesionless Soil
- Open Access
Computational Fluid Dynamics Modeling of Concrete Flows in Drilled Shafts
Drilled shafts are cylindrical, cast-in-place concrete deep foundation elements. During construction, anomalies in drilled shafts can occur due to the kinematics of concrete, flowing radially from the center of the shaft to the concrete cover region at the peripheral edge. This radial component of concrete flow develops veins or creases of poorly cemented or high water-cement ratio material, as the concrete flows around the reinforcement cage of rebars and ties, jeopardizing the shaft integrity. This manuscript presents a three-dimensional computational fluid dynamics (CFD) model of the non-Newtonian concrete flow in drilled shaft construction developed using the finite volume method with interface tracking based on the volume of fluid (VOF) method. The non-Newtonian behavior of the concrete is represented via the Carreau constitutive model. The model results are encouraging as the flow obtained from the simulations shows patterns of both horizontal and vertical creases in the concrete cover region, consistent with previously reported field and laboratory experiments. Moreover, the flow exhibits the concrete head differential developed between the inside and the outside of the reinforcement cage, as exhibited in the physical experiments. This head differential induces the radial component of the concrete flow responsible for the creases that develop in the concrete cover region. Results show that the head differential depends on the flowability of the concrete, consistent with field observations. Less viscous concrete tends to reduce the head differential and the formation of creases of poorly cemented material. The model is unique, making use of state-of-the-art numerical techniques and demonstrating the capability of CFD to model industrially relevant concrete flows.
Open AccessComputational Fluid Dynamics Modeling of Concrete Flows in Drilled Shafts
Drilled shafts are cylindrical, cast-in-place concrete deep foundation elements. During construction, anomalies in drilled shafts can occur due to the kinematics of concrete, flowing radially from the center of the shaft to the concrete cover region at the peripheral edge. This radial component of concrete flow develops veins or creases of poorly cemented or high water-cement ratio material, as the concrete flows around the reinforcement cage of rebars and ties, jeopardizing the shaft integrity. This manuscript presents a three-dimensional computational fluid dynamics (CFD) model of the non-Newtonian concrete flow in drilled shaft construction developed using the finite volume method with interface tracking based on the volume of fluid (VOF) method. The non-Newtonian behavior of the concrete is represented via the Carreau constitutive model. The model results are encouraging as the flow obtained from the simulations shows patterns of both horizontal and vertical creases in the concrete cover region, consistent with previously reported field and laboratory experiments. Moreover, the flow exhibits the concrete head differential developed between the inside and the outside of the reinforcement cage, as exhibited in the physical experiments. This head differential induces the radial component of the concrete flow responsible for the creases that develop in the concrete cover region. Results show that the head differential depends on the flowability of the concrete, consistent with field observations. Less viscous concrete tends to reduce the head differential and the formation of creases of poorly cemented material. The model is unique, making use of state-of-the-art numerical techniques and demonstrating the capability of CFD to model industrially relevant concrete flows.
- 3 July 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 395
Effect of imperfect cure on tensile bond measurement
- 3 July 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 395
Effect of imperfect cure on tensile bond measurement
- 2 January 2022
- Published by Taylor & Francis in Architectural Engineering and Design Management
- Vol. 18 (1) , 26-37
Determination of safety factors for structural bamboo design applications
Use of bamboo as a construction material has world-wide potential given it is lightweight, highly-renewable, and fast-growing. The pitfall lies largely in the variability of the material properties reported by numerous investigators. Previous research has sought to correlate various material properties to external factors but results are conflicting. This paper applies the same approaches previously applied to other structural materials using U.S. approved standards. It outlines the significance of a common set of material properties with the goal of identifying the necessary safety factors designers can incorporate when using bamboo to ensure a given level of reliability and an acceptable failure rate. These results when combined with international building codes for bamboo can allow for greater structural application of bamboo in architectural designs.
- 2 January 2022
- Published by Taylor & Francis in Architectural Engineering and Design Management
- Vol. 18 (1) , 26-37
Determination of safety factors for structural bamboo design applications
Use of bamboo as a construction material has world-wide potential given it is lightweight, highly-renewable, and fast-growing. The pitfall lies largely in the variability of the material properties reported by numerous investigators. Previous research has sought to correlate various material properties to external factors but results are conflicting. This paper applies the same approaches previously applied to other structural materials using U.S. approved standards. It outlines the significance of a common set of material properties with the goal of identifying the necessary safety factors designers can incorporate when using bamboo to ensure a given level of reliability and an acceptable failure rate. These results when combined with international building codes for bamboo can allow for greater structural application of bamboo in architectural designs.
- Open Access
- 3 December 2021
- Published by International Association of Advanced Materials in Advanced Materials Proceedings
- Vol. 5 (2) , 1-5
Polymer Slurry in Foundation Construction
Research Article Open Access Polymer Slurry in Foundation Construction Sarah Mobley, Kelly Costello, Gray Mullins* Department of Civil & Environmental Engineering, University of South Florida, Tampa, FL 33620, USA Adv. Mater. Proc., 2020, 5 (2), 20020400 DOI: 10.5185/amp.2020.020400 Publication Date (Web):05 April 2020 Copyright © IAAM-VBRI Press Full Abstract
- 3 December 2021
- Published by International Association of Advanced Materials in Advanced Materials Proceedings
- Vol. 5 (2) , 1-5
Open AccessPolymer Slurry in Foundation Construction
Research Article Open Access Polymer Slurry in Foundation Construction Sarah Mobley, Kelly Costello, Gray Mullins* Department of Civil & Environmental Engineering, University of South Florida, Tampa, FL 33620, USA Adv. Mater. Proc., 2020, 5 (2), 20020400 DOI: 10.5185/amp.2020.020400 Publication Date (Web):05 April 2020 Copyright © IAAM-VBRI Press Full Abstract
- 1 May 2020
- Published by ASTM International in Geotechnical Testing Journal
- Vol. 44 (3) , 741-755
Selection of Thermal Integrity Data Regression Parameters
Thermal integrity profiling (TIP) is a nondestructive method of evaluating the as-built features of cast-in-place concrete foundation elements such as bored piles, drilled shafts, continuous flight auger piles, barrettes, dams, or diaphragm walls. The technology measures the temperature of curing concrete along the length of the element to detect the presence (or absence) of hydrating cement, alignment of the reinforcing steel, and rebar cover thickness. Like many integrity methods used for drilled shafts, direct comparison of local concrete conditions are made relative to the overall normal or average concrete conditions with two exceptions: the top and bottom of the element, which cannot be directly compared with the rest of the shaft temperature without adjusting those measurements to account for end effects. This paper outlines the selection of the end adjustment parameters to ensure the top and bottom shapes are properly defined. The presented data regression process is based on both numerical model findings as well as the statistical findings from 232 TIP-tested shafts on the same project.
- 1 May 2020
- Published by ASTM International in Geotechnical Testing Journal
- Vol. 44 (3) , 741-755
Selection of Thermal Integrity Data Regression Parameters
Thermal integrity profiling (TIP) is a nondestructive method of evaluating the as-built features of cast-in-place concrete foundation elements such as bored piles, drilled shafts, continuous flight auger piles, barrettes, dams, or diaphragm walls. The technology measures the temperature of curing concrete along the length of the element to detect the presence (or absence) of hydrating cement, alignment of the reinforcing steel, and rebar cover thickness. Like many integrity methods used for drilled shafts, direct comparison of local concrete conditions are made relative to the overall normal or average concrete conditions with two exceptions: the top and bottom of the element, which cannot be directly compared with the rest of the shaft temperature without adjusting those measurements to account for end effects. This paper outlines the selection of the end adjustment parameters to ensure the top and bottom shapes are properly defined. The presented data regression process is based on both numerical model findings as well as the statistical findings from 232 TIP-tested shafts on the same project.
- 1 November 2019
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 116 (6) , 75-86
Role of Porosity on Durability of Carbon Fiber-Reinforced Polymer-Concrete Bond
- 1 November 2019
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 116 (6) , 75-86
Role of Porosity on Durability of Carbon Fiber-Reinforced Polymer-Concrete Bond
- 1 July 2019
- Published by ASTM International
- p. 128-144
Automated Down-Hole Testing System for Drilled Shaft Slurry
Proper performance of slurries used to stabilize drilled shaft excavations is achieved by ensuring that the density, viscosity, and sand content stay within empirically defined limits set by past experience, research findings, or manufacturer recommendations. When slurry properties fall outside these limits, the excavation walls can collapse or material can become entrapped within the shaft concrete, or both. Therefore, it is imperative that the slurry be periodically tested starting prior to its introduction into the excavation. Because all measurements are performed manually, slurry testing is time-consuming. However, with the overwhelming advances in digital devices, it is not unreasonable to assume that slurry property tests are equally applicable to this trend. This paper introduces a prototype down-hole slurry testing system that was shown to be surprisingly easy and fast to use despite the experimental nature of the design. One of the demonstration shafts sampled at six different depths was tested in less than 10 min. In contrast, conventional, manually performed testing can take more than an hour to perform the same number of tests.
- 1 July 2019
- Published by ASTM International
- p. 128-144
Automated Down-Hole Testing System for Drilled Shaft Slurry
Proper performance of slurries used to stabilize drilled shaft excavations is achieved by ensuring that the density, viscosity, and sand content stay within empirically defined limits set by past experience, research findings, or manufacturer recommendations. When slurry properties fall outside these limits, the excavation walls can collapse or material can become entrapped within the shaft concrete, or both. Therefore, it is imperative that the slurry be periodically tested starting prior to its introduction into the excavation. Because all measurements are performed manually, slurry testing is time-consuming. However, with the overwhelming advances in digital devices, it is not unreasonable to assume that slurry property tests are equally applicable to this trend. This paper introduces a prototype down-hole slurry testing system that was shown to be surprisingly easy and fast to use despite the experimental nature of the design. One of the demonstration shafts sampled at six different depths was tested in less than 10 min. In contrast, conventional, manually performed testing can take more than an hour to perform the same number of tests.
- 6 June 2018
- Published by American Society of Civil Engineers (ASCE)
- p. 470-479
Effects of Temporary Casing on the Side Shear of Small Scale Rock Sockets in Limestone
The presence of temporary casing between freshly placed concrete and surrounding limestone formations may inadvertently leave crumbled debris upon casing extraction that may lead to side shear reduction. The primary objective of this work was to quantify how different methods of installation and extraction of temporary casings affect the side shear resistance on small scale limestone sockets. About 29 miniature shaft specimens were cast in six different simulated limestone beds ranging in strengths from 65 to 885 psi. Three casing installation/extraction methods were used: rotated with coarse cutting teeth, rotated with fine cutting teeth, and driven. At least one of the sockets in each bed was selected to be an uncased control, in which the casing was extracted and all debris were cleaned out prior to concreting. Results showed that the presence of casing caused loss in capacity. Weaker, more voided limestone was less affected than stronger, more contiguous material.
- 6 June 2018
- Published by American Society of Civil Engineers (ASCE)
- p. 470-479
Effects of Temporary Casing on the Side Shear of Small Scale Rock Sockets in Limestone
The presence of temporary casing between freshly placed concrete and surrounding limestone formations may inadvertently leave crumbled debris upon casing extraction that may lead to side shear reduction. The primary objective of this work was to quantify how different methods of installation and extraction of temporary casings affect the side shear resistance on small scale limestone sockets. About 29 miniature shaft specimens were cast in six different simulated limestone beds ranging in strengths from 65 to 885 psi. Three casing installation/extraction methods were used: rotated with coarse cutting teeth, rotated with fine cutting teeth, and driven. At least one of the sockets in each bed was selected to be an uncased control, in which the casing was extracted and all debris were cleaned out prior to concreting. Results showed that the presence of casing caused loss in capacity. Weaker, more voided limestone was less affected than stronger, more contiguous material.