Arturo Estrada-Vargas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Arturo Estrada-Vargas has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Maximiliano Bárcena-Soto
Departamento de Química, Universidad de Guadalajara, C.P. 44430 Guadalajara, Jalisco, Mexico
6 shared publications - Norberto Casillas
Department of Chemistry, University of Guadalajara, Guadalajara, Mexico
4 shared publications - Carlos Alberto Carreón Gutiérrez
Universidad Autónoma de Tamaulipas
3 shared publications - Edith Xio Mara García García
Universidad de Guadalajara
3 shared publications - Mario Pérez González
Universidad de Guadalajara
3 shared publications Universidad de Guadalajara
3 shared publications
Latest Publications
- 6 May 2024
- Published by Astra Ediciones
- p. 79-84
Rocas sedimentarias
- 6 May 2024
- Published by Astra Ediciones
- p. 85-88
Rocas metamórficas
- 6 May 2024
- Published by Astra Ediciones
- p. 73-78
Rocas ígneas
- Open Access
- 23 May 2023
- Published by Frontiers Media SA in Frontiers in Environmental Science
- Vol. 11
Hydrogen peroxide formation in carbon clothes for enhancement of an electro-oxidation tertiary treatment for tequila vinasse wastewater
Carbon-based electrodes have been extensively used as cathodes for the electro-generation of H₂O₂, which is used in the production of the hydroxyl radical •OH to mineralize organic compounds in several types of wastewater. Carbon cloth has been also used in combination with activated carbon for the combined adsorption and oxidation of persistent organic compounds present in tequila vinasse wastewater. Whereas most of the works regarding the H₂O₂ electro-generation involve relatively complex processes to enhance the catalytic activity or the electrochemically active area of these electrodes, calcination by itself represents a simple and low-cost option to enhance these cathodic and anodic functions, especially in the fabrication of large area electrodes that could be needed to treat the large amount of tequila vinasse wastewater that is produced daily. In this work, the effect of calcination at 300°C and 600°C of carbon clothes in the oxidation current and H₂O₂ production at different potentials in H₂SO₄ was studied. Oxidation current increased 700% upon calcination at 600°C, compared to no calcination. H₂O₂ was produced only in a narrow range of polarizations, whereas calcination at 600 °C increased the generation rate from 7.1 ± 0.3 to 17.8 ± 0.4 mg L⁻1 h⁻1.
- 23 May 2023
- Published by Frontiers Media SA in Frontiers in Environmental Science
- Vol. 11
Open AccessHydrogen peroxide formation in carbon clothes for enhancement of an electro-oxidation tertiary treatment for tequila vinasse wastewater
Carbon-based electrodes have been extensively used as cathodes for the electro-generation of H₂O₂, which is used in the production of the hydroxyl radical •OH to mineralize organic compounds in several types of wastewater. Carbon cloth has been also used in combination with activated carbon for the combined adsorption and oxidation of persistent organic compounds present in tequila vinasse wastewater. Whereas most of the works regarding the H₂O₂ electro-generation involve relatively complex processes to enhance the catalytic activity or the electrochemically active area of these electrodes, calcination by itself represents a simple and low-cost option to enhance these cathodic and anodic functions, especially in the fabrication of large area electrodes that could be needed to treat the large amount of tequila vinasse wastewater that is produced daily. In this work, the effect of calcination at 300°C and 600°C of carbon clothes in the oxidation current and H₂O₂ production at different potentials in H₂SO₄ was studied. Oxidation current increased 700% upon calcination at 600°C, compared to no calcination. H₂O₂ was produced only in a narrow range of polarizations, whereas calcination at 600 °C increased the generation rate from 7.1 ± 0.3 to 17.8 ± 0.4 mg L⁻1 h⁻1.
- 3 October 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 28 (19) , 23699-23706
Study of a coupled adsorption/electro-oxidation process as a tertiary treatment for tequila industry wastewater
Vinasse wastewater from tequila industry that has been conventionally treated is usually characterized by a chemical oxygen demand (COD) above 150 mg L−1, which is the maximum content permitted for discharge by Mexican Regulation. In order to increase the wastewater quality, different processes were applied, and from the experimental results, the advantages and limitations were analyzed. In this way, although Fenton experiments showed acceptable COD removal efficiencies (79–90%), operation as well as cost limit its adoption as a viable technology. Therefore, additional experiments explored electro-Fenton (EF) as well as adsorption coupled to EF in a tubular reactor. The corresponding data revealed that there was no additional increase in COD removal performance probably due to the low oxygen solubility in the electrolytic solution and the high pH that prevents the existence of Fe2+ ions necessary for the Fenton mixture. In view of these results, when an activated carbon (AC) filter was coupled to polarization at current densities between 0.5 and 2 mA cm−2, removal efficiencies from 71 to 81%, corresponding to final COD of 78 to 33 mg L−1, were achieved. Also, the adsorbent surface was continuously regenerated, promoting a more efficient adsorption and a longer service life for the AC filter. In this case, by using a current density of 0.5 mA cm−2, COD was reduced to sufficiently small values for discharge into natural water bodies, maintaining low energy consumption and therefore acceptable operation costs.
- 3 October 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 28 (19) , 23699-23706
Study of a coupled adsorption/electro-oxidation process as a tertiary treatment for tequila industry wastewater
Vinasse wastewater from tequila industry that has been conventionally treated is usually characterized by a chemical oxygen demand (COD) above 150 mg L−1, which is the maximum content permitted for discharge by Mexican Regulation. In order to increase the wastewater quality, different processes were applied, and from the experimental results, the advantages and limitations were analyzed. In this way, although Fenton experiments showed acceptable COD removal efficiencies (79–90%), operation as well as cost limit its adoption as a viable technology. Therefore, additional experiments explored electro-Fenton (EF) as well as adsorption coupled to EF in a tubular reactor. The corresponding data revealed that there was no additional increase in COD removal performance probably due to the low oxygen solubility in the electrolytic solution and the high pH that prevents the existence of Fe2+ ions necessary for the Fenton mixture. In view of these results, when an activated carbon (AC) filter was coupled to polarization at current densities between 0.5 and 2 mA cm−2, removal efficiencies from 71 to 81%, corresponding to final COD of 78 to 33 mg L−1, were achieved. Also, the adsorbent surface was continuously regenerated, promoting a more efficient adsorption and a longer service life for the AC filter. In this case, by using a current density of 0.5 mA cm−2, COD was reduced to sufficiently small values for discharge into natural water bodies, maintaining low energy consumption and therefore acceptable operation costs.
- Open Access
- 13 May 2016
- Published by Wiley in ChemElectroChem
- Vol. 3 (6) , 1026
Inside Back Cover: Differentiation between Single‐ and Double‐Stranded DNA through Local Capacitance Measurements (ChemElectroChem 6/2016)
- 13 May 2016
- Published by Wiley in ChemElectroChem
- Vol. 3 (6) , 1026
Open AccessInside Back Cover: Differentiation between Single‐ and Double‐Stranded DNA through Local Capacitance Measurements (ChemElectroChem 6/2016)
- 11 March 2016
- Published by Wiley in ChemElectroChem
- Vol. 3 (6) , 855-857
Differentiation between Single‐ and Double‐Stranded DNA through Local Capacitance Measurements
Local differentiation of single‐stranded (ss) and double‐stranded (ds) DNA in microarrays by using electrochemical techniques has gained increasing interest. We propose a method for distinguishing areas on gold electrodes modified with ssDNA and dsDNA based on the difference in their local capacitance. The local capacitance is visualized by means of scanning electrochemical impedance microscopy and alternating‐current scanning electrochemical microscopy.
- 11 March 2016
- Published by Wiley in ChemElectroChem
- Vol. 3 (6) , 855-857
Differentiation between Single‐ and Double‐Stranded DNA through Local Capacitance Measurements
Local differentiation of single‐stranded (ss) and double‐stranded (ds) DNA in microarrays by using electrochemical techniques has gained increasing interest. We propose a method for distinguishing areas on gold electrodes modified with ssDNA and dsDNA based on the difference in their local capacitance. The local capacitance is visualized by means of scanning electrochemical impedance microscopy and alternating‐current scanning electrochemical microscopy.
- 3 October 2015
- Published by Wiley in Chempluschem
- Vol. 81 (1) , 49-57
Kinetic Passivation Effect of Localized Differential Aeration on Brass
The formation of a localized differential aeration cell on metals, susceptible to both anodic and cathodic corrosion, is a serious threat because of multiple degradation processes commencing with the passivation layer destruction. By using local electrochemical and X‐ray dispersive techniques, it has been demonstrated that the differential aeration cell formed on high brass (α‐brass, Cu65‐Zn35) in the presence of 1H‐benzotriazole or 5‐methyl‐1H‐benzotriazole plays both corrosion‐inhibiting and accelerating roles, depending on the inhibitor exposure time. Alternating‐current scanning electrochemical microscopy was used to image local electrochemical activity, whereas energy‐dispersive X‐ray spectroscopy provided evidence for the mechanism of the observed phenomena. Short‐term exposure to the inhibitor (5 min) promotes the formation of a passivation layer in the waterline region. In contrast, after prolonged exposure (45 min), a deficient passivation layer develops for both inhibitors. An excess of zinc(II)–inhibitor complexes in the passivation layer is accountable for the corrosion resistance of the region with high differential aeration. Rapid dezincification and local alkalinization facilitate the initial rapid formation of a passivation layer in the area under differential aeration to preserve its composition upon further modification.
- 3 October 2015
- Published by Wiley in Chempluschem
- Vol. 81 (1) , 49-57
Kinetic Passivation Effect of Localized Differential Aeration on Brass
The formation of a localized differential aeration cell on metals, susceptible to both anodic and cathodic corrosion, is a serious threat because of multiple degradation processes commencing with the passivation layer destruction. By using local electrochemical and X‐ray dispersive techniques, it has been demonstrated that the differential aeration cell formed on high brass (α‐brass, Cu65‐Zn35) in the presence of 1H‐benzotriazole or 5‐methyl‐1H‐benzotriazole plays both corrosion‐inhibiting and accelerating roles, depending on the inhibitor exposure time. Alternating‐current scanning electrochemical microscopy was used to image local electrochemical activity, whereas energy‐dispersive X‐ray spectroscopy provided evidence for the mechanism of the observed phenomena. Short‐term exposure to the inhibitor (5 min) promotes the formation of a passivation layer in the waterline region. In contrast, after prolonged exposure (45 min), a deficient passivation layer develops for both inhibitors. An excess of zinc(II)–inhibitor complexes in the passivation layer is accountable for the corrosion resistance of the region with high differential aeration. Rapid dezincification and local alkalinization facilitate the initial rapid formation of a passivation layer in the area under differential aeration to preserve its composition upon further modification.
- 19 July 2012
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 16 (12) , 3777-3782
Carbon nanotubes/carbon xerogel-nafion electrodes: a comparative study of preparation methods
- 19 July 2012
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 16 (12) , 3777-3782
Carbon nanotubes/carbon xerogel-nafion electrodes: a comparative study of preparation methods
- 29 November 2011
- Published by The Electrochemical Society in ECS Transactions
- Vol. 36 (1) , 363-372
Detection of Cu, Pb, Cd and Zn in Mexican Spirituous Beverages by Differential Pulse Polarography (DPP)
This work is aimed to investigate the metal content (i.e., Cu, Pb, Cd y Zn) present in Mexican spirituous beverages which include: Tequila, Raicilla, Sotol and Mezcal by using Differential Pulse Polarography (DPP). Metal content depends on the type of beverage, geographic region of origin, and aging stage. Noteworthy is metal removal, specifically copper, during the aging process of tequila, suggesting a copper capture by the oak wooden aging barrel. Metal content in aged beverages can be an alternative method to estimate both aging time and sneaky aged tequilas. Further, the results presented in this paper may provide a guide to establish metal regulations to improve quality control of spirituous Mexican beverages.
- 29 November 2011
- Published by The Electrochemical Society in ECS Transactions
- Vol. 36 (1) , 363-372
Detection of Cu, Pb, Cd and Zn in Mexican Spirituous Beverages by Differential Pulse Polarography (DPP)
This work is aimed to investigate the metal content (i.e., Cu, Pb, Cd y Zn) present in Mexican spirituous beverages which include: Tequila, Raicilla, Sotol and Mezcal by using Differential Pulse Polarography (DPP). Metal content depends on the type of beverage, geographic region of origin, and aging stage. Noteworthy is metal removal, specifically copper, during the aging process of tequila, suggesting a copper capture by the oak wooden aging barrel. Metal content in aged beverages can be an alternative method to estimate both aging time and sneaky aged tequilas. Further, the results presented in this paper may provide a guide to establish metal regulations to improve quality control of spirituous Mexican beverages.