TBTyler Bowman

Tyler Bowman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tyler Bowman has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Setup and Testing of the RS105 Wire Array Pulser

    by Usdoe National Nuclear Security Administration (Nnsa), Lee Joshua Rashkin, Albuquerque Sandia National Laboratories (Snl-Nm), Tyler Bowman, Nicholas Scott Baker, Matthew Preston Harden Oliveira, Ian Alexander Bean

    The report covers the RS105 Wire Array Pulser testbed. The setup of the wire array at Reapplication, building 996, is laid out. Setup instructions are provided. Details of the commissioning test are given. Measurement data from the commissioning test shows the field output of the array exceeds 50 kV/m and that tuning the pulser output with a peaking switch can provide a rise time of ~2.3 ns and a pulse width of ~23 ns. The field levels and timeframes shown are within the tolerance conditions of

  • Open Access

    E1 Incidence Modeling Response of Solid State Transformer Transistors

    by Albuquerque Sandia National Laboratories (Snl-Nm), Tyler Bowman, Usdoe National Nuclear Security Administration (Nnsa), Mihai Negoita

  • Open Access

    4-Leg Inverter Modeling for E2 Mitigation in Solid State Transformers

    by Albuquerque Sandia National Laboratories (Snl-Nm), Tyler Bowman, Usdoe National Nuclear Security Administration (Nnsa), Ronald Matthews, Lee Rashkin

  • Resilient Energy Systems Development at Sandia National Laboratories

    by Albuquerque Sandia National Laboratories (Snl-Nm), Lee Rashkin, Usdoe National Nuclear Security Administration (Nnsa), Tyler Bowman, Jack Flicker, Andrew Padgett, Steven Glover

  • Open Access

    Granular metal optimization for ns-responsive arresters

    by Albuquerque Sandia National Laboratories (Snl-Nm), Laura Butler Biedermann, Michael McGarry, Simeon James Gilbert, Tyler Bowman, Brianna Alexandra Klein, Paul G. Kotula, Michael Phillip Siegal

    Presentation for GOMACTech (Government Microcircuit Applications & Critical Technology Conference)

  • Nanosecond Transient Validation of Surge Arrester Models to Predict Electromagnetic Pulse Response

    by Tyler C. Bowman, Thomas Kmieciak, Laura B. Biedermann

    The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. This article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.


  • Assessment of Terahertz Imaging for Excised Breast Cancer Tumors with Image Morphing

    by Tanny Chavez, Tyler Bowman, Jingxian Wu, Keith Bailey, Magda El-Shenawee

    This paper presents an image morphing algorithm for quantitative evaluation methodology of terahertz (THz) images of excised breast cancer tumors. Most current studies on the assessment of THz imaging rely on qualitative evaluation, and there is no established benchmark or procedure to quantify the THz imaging performance. The proposed morphing algorithm provides a tool to quantitatively align the THz image with the histopathology image. Freshly excised xenograft murine breast cancer tumors are imaged using the pulsed THz imaging and spectroscopy system in the reflection mode. Upon fixing the tumor tissue in formalin and embedding in paraffin, a formalin-fixed paraffin-embedded (FFPE) tissue block is produced. A thin slice of the block is prepared for the pathology image while another THz reflection image is produced directly from the block. We developed an algorithm of mesh morphing using homography mapping of the histopathology image to adjust the alignment, shape, and resolution to match the external contour of the tissue in the THz image. Unlike conventional image morphing algorithms that rely on internal features of the source and target images, only the external contour of the tissue is used to avoid bias. Unsupervised Bayesian learning algorithm is applied to THz images to classify the tissue regions of cancer, fat, and muscles present in xenograft breast tumors. The results demonstrate that the proposed mesh morphing algorithm can provide more effective and accurate evaluation of THz imaging compared with existing algorithms. The results also showed that while THz images of FFPE tissue are highly in agreement with pathology images, challenges remain in assessing THz imaging of fresh tissue.


  • Pulsed terahertz imaging of breast cancer in freshly excised murine tumors

    by Tyler Bowman, Tanny Chavez, Kamrul Khan, Jingxian Wu, Avishek Chakraborty, Narasimhan Rajaram, Keith Bailey, Magda El-Shenawee

    This paper investigates terahertz (THz) imaging and classification of freshly excised murine xenograft breast cancer tumors. These tumors are grown via injection of E0771 breast adenocarcinoma cells into the flank of mice maintained on high-fat diet. Within 1 h of excision, the tumor and adjacent tissues are imaged using a pulsed THz system in the reflection mode. The THz images are classified using a statistical Bayesian mixture model with unsupervised and supervised approaches. Correlation with digitized pathology images is conducted using classification images assigned by a modal class decision rule. The corresponding receiver operating characteristic curves are obtained based on the classification results. A total of 13 tumor samples obtained from 9 tumors are investigated. The results show good correlation of THz images with pathology results in all samples of cancer and fat tissues. For tumor samples of cancer, fat, and muscle tissues, THz images show reasonable correlation with pathology where the primary challenge lies in the overlapping dielectric properties of cancer and muscle tissues. The use of a supervised regression approach shows improvement in the classification images although not consistently in all tissue regions. Advancing THz imaging of breast tumors from mice and the development of accurate statistical models will ultimately progress the technique for the assessment of human breast tumor margins.


  • Nondestructive Imaging of Packaged Microelectronics using Pulsed Terahertz Technology

    by Tyler Bowman, Magda El-Shenawee

    This work presents the use of terahertz reflection imaging for nondestructive evaluation of packaged microelectronics. Power MOSFETs and SRAM devices are placed in a pulsed terahertz imaging system in the reflection mode with an incident angle of 30°. From the received signal at each point on the sample under test, the internal structure of the device can be clearly seen. For transistors, terahertz nondestructive imaging has been successful in determining die size and location as well as the bond wire size, number, and connections. High-pass frequency filters are utilized to enhance the image quality for viewing the bond wires. In addition, the terahertz B-scans are used to determine additional information including the vertical position of the bond wires and the die inside the packaged device. For the SRAM, the terahertz nondestructive imaging shows similar effectiveness in defining the layout of the metal connections inside the package and the wire positions. Thus terahertz imaging is shown to have a strong potential for nondestructive evaluation of these devices.


  • A phantom study of terahertz spectroscopy and imaging of micro- and nano-diamonds and nano-onions as contrast agents for breast cancer

    by Tyler Bowman, Alec Walter, Olga Shenderova, Nicholas Nunn, Gary McGuire, Magda El-Shenawee

    Terahertz (THz) imaging is effective in distinguishing between cancerous, healthy, and fatty tissues in breast tumors, but a challenge remains in the contrast between cancerous and fibroglandular (healthy) tissues. This work investigates carbon-based nanoparticles as potential contrast agents for THz imaging of breast cancer. Microdiamonds, nanodiamonds (NDs), and nanometer-scale onion-like carbon (OLC) are characterized with THz transmission spectroscopy in low-absorption backgrounds of polydimethylsiloxane or polyethylene. The refractive index and absorption coefficients are calculated based on the measured electric fields. NDs show little effect on the THz signal, microdiamonds express resonance-like, size-dependent absorption peaks, and OLC provides a uniform increase in the optical properties even at low concentration. Due to its strong interaction with THz frequencies and ability to be activated for selective binding to cancer cells, OLC is implemented into engineered three-dimensional breast tumor models composed of phantom tissue mimicking infiltrating ductal carcinoma surrounded by a phantom mimicking healthy fibroglandular tissue. This model is imaged using the THz reflection mode to examine the effectiveness of contrast agents for differentiation between the two tissue types. In both spectroscopy and imaging, a 10% concentration of OLC shows the strongest impact on the THz signal and holds promise as a THz contrast agent.