Grace Mendonca De Souza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Grace Mendonca De Souza has a total of 231 co-authors. Here are the top co-authors by number of shared publications:
- Renally Bezerra Wanderley Lima
Department of Restorative Dentistry, Federal University of Paraíba (UFPB), João Pessoa, Paraíba, Brazil
7 shared publications - Laura Eva Tam
Faculty of Dentistry, University of Toronto, 124 Edward St, Toronto, ON, M5G1G6, Canada
5 shared publications - Sandro Basso Bitencourt
Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), School of Dentistry, Araçatuba, Brazil
5 shared publications Daniela Micheline dos Santos
4 shared publications- Natália Almeida Bastos-Bitencourt
Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
4 shared publications - Aldiéris Alves Pesqueira
Department of Dental Materials and Prosthodontics School of Dentistry São Paulo State University (UNESP) Araçatuba Brazil
3 shared publications
Latest Publications
- 6 October 2025
- Published by Wiley in European Journal of Oral Sciences
- Vol. 133 (6) , e70042
3D‐printed resin materials for indirect restorations—a scoping review and evidence gap map
This review aimed to map the available scientific evidence regarding the physical–mechanical properties and clinical performance of 3D‐printed resins used for indirect restorations and identify research gaps. PRISMA guidelines were followed, with methodological details preregistered in the Open Science Framework. A literature search was conducted in May 2025 across PubMed/Medline, Scopus, Embase, and Web of Science, without restrictions on publication date or language. Studies evaluating the physico‐mechanical properties (color stability, flexural strength, surface roughness, and hardness) and clinical performance (esthetic, functional, or biological properties) of 3D‐printed resins for full or partial coverage restorations, whether permanent or provisional, were included. A total of 36 studies met the inclusion criteria, including 35 in vitro and 1 clinical trial. The most frequently analyzed resin for temporary restorations was C&B MFH (NextDent) ( n = 10), while for definitive restorations, VSC+ (Bego) ( n = 5) was the most frequently used. Nonetheless, further research is required to evaluate their clinical performance in both temporary and definitive restorations. The available evidence indicates that a wide variety of 3D‐printed resins are available for clinical use, mainly as provisional restorative materials. There is still no sufficient clinical evidence to support the use of 3D‐printed resins for indirect definitive restorations.
- 6 October 2025
- Published by Wiley in European Journal of Oral Sciences
- Vol. 133 (6) , e70042
3D‐printed resin materials for indirect restorations—a scoping review and evidence gap map
This review aimed to map the available scientific evidence regarding the physical–mechanical properties and clinical performance of 3D‐printed resins used for indirect restorations and identify research gaps. PRISMA guidelines were followed, with methodological details preregistered in the Open Science Framework. A literature search was conducted in May 2025 across PubMed/Medline, Scopus, Embase, and Web of Science, without restrictions on publication date or language. Studies evaluating the physico‐mechanical properties (color stability, flexural strength, surface roughness, and hardness) and clinical performance (esthetic, functional, or biological properties) of 3D‐printed resins for full or partial coverage restorations, whether permanent or provisional, were included. A total of 36 studies met the inclusion criteria, including 35 in vitro and 1 clinical trial. The most frequently analyzed resin for temporary restorations was C&B MFH (NextDent) ( n = 10), while for definitive restorations, VSC+ (Bego) ( n = 5) was the most frequently used. Nonetheless, further research is required to evaluate their clinical performance in both temporary and definitive restorations. The available evidence indicates that a wide variety of 3D‐printed resins are available for clinical use, mainly as provisional restorative materials. There is still no sufficient clinical evidence to support the use of 3D‐printed resins for indirect definitive restorations.
- 14 July 2025
- Published by Springer Nature in Supportive Care in Cancer
- Vol. 33 (8) , 1-10
Microshear bond strength of conventional and bioactive restorative materials to irradiated and non-irradiated dentin: an in vitro study
Purpose To evaluate the effect of conventional and bioactive restorative materials on bond strength to control (non-irradiated) and irradiated dentin. Methods Human dentin fragments (240) were polished and divided into non-irradiated dentin (NI; n = 120) and irradiated dentin (ID; n = 120). ID specimens received 70 Gy irradiation (2 Gy/fraction, 5 days/week for 7 weeks). All dentin surfaces were bonded to restorative materials with Scotchbond universal adhesive in self-etching mode. Microshear bond strength cylinders were built on the bonded surface according to the restorative material (4 subgroups, n = 30): conventional resin composite (CC-Filtek Z250) and three bioactive restorative composites (BCI-Activa BioActive-Restorative; BCII-Beautiful II; BCIII-Predicta Bulk). Specimens were stored in water at 37 °C for 24 h or 30 days and subjected to microshear bond strength test. The data was analyzed using two-way ANOVA and Tukey's post-hoc test (⍺ < 0.05). The morphological surface of both NI and ID dentin (n = 3) was analyzed using Scanning Electron Microscopy (SEM). Results Two-way ANOVA revealed a significant effect of the Time/Radiation (p < 0.001). Restorative material (p = 0.191) and the interaction Time/Radiation*Restorative material (p = 0.169) were not significant. Irradiation decreased the bond strength of CC specimens at both 24 h (p < 0.001) and 30 days (p < 0.001). None of the bioactive materials were significantly affected by irradiation and storage time. The SEM analysis revealed morphological changes in the ID specimens. Conclusion Ionizing radiation-induced morphological changes in the dentin surface. These changes negatively affected the conventional resin composite bond strengths to dentin. However, these morphological alterations did not affect the bond strength of the bioactive restorative materials.
- 14 July 2025
- Published by Springer Nature in Supportive Care in Cancer
- Vol. 33 (8) , 1-10
Microshear bond strength of conventional and bioactive restorative materials to irradiated and non-irradiated dentin: an in vitro study
Purpose To evaluate the effect of conventional and bioactive restorative materials on bond strength to control (non-irradiated) and irradiated dentin. Methods Human dentin fragments (240) were polished and divided into non-irradiated dentin (NI; n = 120) and irradiated dentin (ID; n = 120). ID specimens received 70 Gy irradiation (2 Gy/fraction, 5 days/week for 7 weeks). All dentin surfaces were bonded to restorative materials with Scotchbond universal adhesive in self-etching mode. Microshear bond strength cylinders were built on the bonded surface according to the restorative material (4 subgroups, n = 30): conventional resin composite (CC-Filtek Z250) and three bioactive restorative composites (BCI-Activa BioActive-Restorative; BCII-Beautiful II; BCIII-Predicta Bulk). Specimens were stored in water at 37 °C for 24 h or 30 days and subjected to microshear bond strength test. The data was analyzed using two-way ANOVA and Tukey's post-hoc test (⍺ < 0.05). The morphological surface of both NI and ID dentin (n = 3) was analyzed using Scanning Electron Microscopy (SEM). Results Two-way ANOVA revealed a significant effect of the Time/Radiation (p < 0.001). Restorative material (p = 0.191) and the interaction Time/Radiation*Restorative material (p = 0.169) were not significant. Irradiation decreased the bond strength of CC specimens at both 24 h (p < 0.001) and 30 days (p < 0.001). None of the bioactive materials were significantly affected by irradiation and storage time. The SEM analysis revealed morphological changes in the ID specimens. Conclusion Ionizing radiation-induced morphological changes in the dentin surface. These changes negatively affected the conventional resin composite bond strengths to dentin. However, these morphological alterations did not affect the bond strength of the bioactive restorative materials.
- 30 May 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 169, 107085
Evaluation of a new dynamic erosive aging method on the properties of restorative CAD/CAM dental materials
- 30 May 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 169, 107085
Evaluation of a new dynamic erosive aging method on the properties of restorative CAD/CAM dental materials
- Open Access
- 21 April 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107029
Reducing fractures in diamond-milled lithium metasilicate/disilicate glass-ceramics (LMGC/LDGC) by ultrasonic vibration-assisted machining
- 21 April 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107029
Open AccessReducing fractures in diamond-milled lithium metasilicate/disilicate glass-ceramics (LMGC/LDGC) by ultrasonic vibration-assisted machining
- Open Access
- 11 April 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (4) , 137
Thermal Dynamics of Laser-Irradiated Trilayer Bonded-Zirconia Structures
This study aims to assess the thermal dynamics of supporting structures during laser-assisted debonding of bonded yttrium-stabilized zirconia (YSZ) ceramic. We tested the hypothesis that the heat transfer to dentin analog material and composite resin resembles that of dentin. Thirty sintered YSZ (ZirCAD, Ivoclar, Schann, Liechtenstein) slabs (4 mm diameter, 1 mm thickness) were air particle abraded, followed by two coats of Monobond Plus (Ivoclar). The slabs were bonded to exposed occlusal dentin, NEMA G10 dentin analog, or composite resin cylinders using Multilink Automix (Ivoclar) dual-cured cement. The bonded YSZ specimens (n = 10/group) subjected to irradiation with an Er,Cr:YSGG laser (Waterlase MD, Biolase, Foothill Ranch, CA, USA) at 7.5 W, 25 Hz, with 50% water and air for 15 s. Heat transfer during laser irradiation was monitored with an infrared camera (Optris PI 640, Optris GmbH, Berlin, Germany) at 0.1-s intervals. Data were analyzed using one-way ANOVA, which showed no significant differences in mean temperature between zirconia and cement layers across the substrates (composite resin, G10, dentin) (p = 0.0794). These results suggest flexibility in substrate choice for future thermal dynamics studies under laser irradiation.
- 11 April 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (4) , 137
Open AccessThermal Dynamics of Laser-Irradiated Trilayer Bonded-Zirconia Structures
This study aims to assess the thermal dynamics of supporting structures during laser-assisted debonding of bonded yttrium-stabilized zirconia (YSZ) ceramic. We tested the hypothesis that the heat transfer to dentin analog material and composite resin resembles that of dentin. Thirty sintered YSZ (ZirCAD, Ivoclar, Schann, Liechtenstein) slabs (4 mm diameter, 1 mm thickness) were air particle abraded, followed by two coats of Monobond Plus (Ivoclar). The slabs were bonded to exposed occlusal dentin, NEMA G10 dentin analog, or composite resin cylinders using Multilink Automix (Ivoclar) dual-cured cement. The bonded YSZ specimens (n = 10/group) subjected to irradiation with an Er,Cr:YSGG laser (Waterlase MD, Biolase, Foothill Ranch, CA, USA) at 7.5 W, 25 Hz, with 50% water and air for 15 s. Heat transfer during laser irradiation was monitored with an infrared camera (Optris PI 640, Optris GmbH, Berlin, Germany) at 0.1-s intervals. Data were analyzed using one-way ANOVA, which showed no significant differences in mean temperature between zirconia and cement layers across the substrates (composite resin, G10, dentin) (p = 0.0794). These results suggest flexibility in substrate choice for future thermal dynamics studies under laser irradiation.
- Open Access
Effect of Gamma Radiation on the Wear Potential of Hybrid Ceramic to Tooth Enamel
Hybrid ceramics exhibit low wear on antagonist tooth enamel, which may positively impact the oral rehabilitation of head-and-neck irradiated patients who experience alterations in tooth microstructure and wear resistance. This study aimed to evaluate the wear resistance of hybrid ceramics after gamma radiation exposure in contact with irradiated tooth enamel, as well as their mechanical and chemical properties. Notably, no previous studies focusing on the effects of radiation on hybrid ceramics were found in the literature. Vita Enamic discs and tooth fragments were subjected to daily doses of 2 Gy, totaling 0, 20, 40, 50, 60, and 70 Gy. The wear resistance of hybrid ceramics and a ceramic enamel analog (steatite) was tested against tooth enamel using a chewing simulation machine. Hybrid ceramic specimens underwent hardness, biaxial flexural strength, roughness, and FT-IR analyses. The data were analyzed using an ANOVA and Tukey’s test (α = 0.05). Enamic exposed to 60 and 70 Gy exhibited higher wear and caused less tooth enamel loss compared to steatite. The mechanical and chemical properties remained unchanged after irradiation. The roughness decreased across all groups after a chewing simulation but was not affected by irradiation. In conclusion, ionizing radiation did not alter the material’s properties but increased its wear.
Open AccessEffect of Gamma Radiation on the Wear Potential of Hybrid Ceramic to Tooth Enamel
Hybrid ceramics exhibit low wear on antagonist tooth enamel, which may positively impact the oral rehabilitation of head-and-neck irradiated patients who experience alterations in tooth microstructure and wear resistance. This study aimed to evaluate the wear resistance of hybrid ceramics after gamma radiation exposure in contact with irradiated tooth enamel, as well as their mechanical and chemical properties. Notably, no previous studies focusing on the effects of radiation on hybrid ceramics were found in the literature. Vita Enamic discs and tooth fragments were subjected to daily doses of 2 Gy, totaling 0, 20, 40, 50, 60, and 70 Gy. The wear resistance of hybrid ceramics and a ceramic enamel analog (steatite) was tested against tooth enamel using a chewing simulation machine. Hybrid ceramic specimens underwent hardness, biaxial flexural strength, roughness, and FT-IR analyses. The data were analyzed using an ANOVA and Tukey’s test (α = 0.05). Enamic exposed to 60 and 70 Gy exhibited higher wear and caused less tooth enamel loss compared to steatite. The mechanical and chemical properties remained unchanged after irradiation. The roughness decreased across all groups after a chewing simulation but was not affected by irradiation. In conclusion, ionizing radiation did not alter the material’s properties but increased its wear.
- 23 January 2025
- Published by Wiley in Journal of Dental Education
- Vol. 89 (8) , 1267-1283
Gender Differences in Barriers in Career Development Among a Cohort of Dental Researchers. A Cross‐Sectional Study
Background: This cross‐sectional study investigated gender differences in barriers to career development among dental researchers and between academic and non‐academic women.Methods: An anonymous 34‐item survey assessing barriers to career development and workplace obstacles (14 items), along with demographic/occupation characteristics (22 items), was distributed among dental researchers at the Women In Science Network meetings at 2024 AADOCR/IADR General Session (QR code) and through AADOCR/IADR discussion board (online platform). Differences in barriers and workplace obstacles were analyzed between women and men with chi‐square tests; comparisons were repeated among women working within versus outside academia.Results: A total of 233 participants completed the survey (68.7% women, 45.3% White, two‐thirds working in the United States, 62% in academia). Compared to men, women more frequently reported feeling less supported by leadership (p = 0.039), taking career breaks (p = 0.004), and experiencing bullying/harassment (41.3% vs. 22.6%; p = 0.003), microaggression (55.6% vs. 33.9%; p = 0.001), and gender bias (46.9% vs. 14.5%; p < 0.001) in their workplace, particularly between ages 36 and 65. While work–life balance issues (62.8%) and stress (59.6%) were reported by both, women reported a lack of financial (p = 0.004), administrative (p = 0.045), and mentoring (p = 0.014) support more often than men. Limited to women, those in academia reported more episodes of bullying/harassment (47.9% vs. 23.3%; p = 0.016), microaggression (67.5% vs. 23.3%; p < 0.001), and gender bias (56.4% vs. 20.9%; p < 0.001) than those outside academia, especially between ages 51 and 65. Compared to non‐academic women, those in academia faced more unsatisfactory leadership decisions (p = 0.003), financial (p = 0.006), administrative (p = 0.046), and mentoring (p = 0.007) support.Conclusions: Women in dental research encounter significantly more barriers to development and workplace obstacles than men and non‐academic women.
- 23 January 2025
- Published by Wiley in Journal of Dental Education
- Vol. 89 (8) , 1267-1283
Gender Differences in Barriers in Career Development Among a Cohort of Dental Researchers. A Cross‐Sectional Study
Background: This cross‐sectional study investigated gender differences in barriers to career development among dental researchers and between academic and non‐academic women.Methods: An anonymous 34‐item survey assessing barriers to career development and workplace obstacles (14 items), along with demographic/occupation characteristics (22 items), was distributed among dental researchers at the Women In Science Network meetings at 2024 AADOCR/IADR General Session (QR code) and through AADOCR/IADR discussion board (online platform). Differences in barriers and workplace obstacles were analyzed between women and men with chi‐square tests; comparisons were repeated among women working within versus outside academia.Results: A total of 233 participants completed the survey (68.7% women, 45.3% White, two‐thirds working in the United States, 62% in academia). Compared to men, women more frequently reported feeling less supported by leadership (p = 0.039), taking career breaks (p = 0.004), and experiencing bullying/harassment (41.3% vs. 22.6%; p = 0.003), microaggression (55.6% vs. 33.9%; p = 0.001), and gender bias (46.9% vs. 14.5%; p < 0.001) in their workplace, particularly between ages 36 and 65. While work–life balance issues (62.8%) and stress (59.6%) were reported by both, women reported a lack of financial (p = 0.004), administrative (p = 0.045), and mentoring (p = 0.014) support more often than men. Limited to women, those in academia reported more episodes of bullying/harassment (47.9% vs. 23.3%; p = 0.016), microaggression (67.5% vs. 23.3%; p < 0.001), and gender bias (56.4% vs. 20.9%; p < 0.001) than those outside academia, especially between ages 51 and 65. Compared to non‐academic women, those in academia faced more unsatisfactory leadership decisions (p = 0.003), financial (p = 0.006), administrative (p = 0.046), and mentoring (p = 0.007) support.Conclusions: Women in dental research encounter significantly more barriers to development and workplace obstacles than men and non‐academic women.
- 3 November 2024
- Published by Wiley in Journal of Dental Education
- Vol. 89 (4) , 529-536
Knowledge and perception of dental educators regarding relative value units: A pilot study
Purpose: The aim of this pilot study was to evaluate the knowledge and perception among dental educators regarding the use of relative value units (RVUs) in medicine, perceived benefits in dentistry, and the relative ranking of the components to define RVUs in dentistry.Methods: A convenience sample of dental educators participating in the American Dental Education Association's Leadership Institute (2023–2024) cohort was surveyed for their knowledge and perception regarding RVUs. The responses were stratified based on experience with RVUs prior to statistical analyses (α = 0.05).Results: Twenty‐six dental educators from 18 different North American dental schools and nine different dental specialties participated in this pilot study. Although not significant, a higher proportion of dental educators with prior experience perceived RVUs as a valuable tool in dental practice for assigning chair time, developing payment models, and tracking student–resident progress in a clinical course. There was a lack of consensus among dental educators regarding the components for determining dental procedural RVUs.Conclusion: This pilot study provides limited evidence that prior knowledge of RVUs may be related to its perceived benefits among dental educators, but a broader study design is needed to draw meaningful conclusions and universally acceptable components for determining RVUs in dentistry.
- 3 November 2024
- Published by Wiley in Journal of Dental Education
- Vol. 89 (4) , 529-536
Knowledge and perception of dental educators regarding relative value units: A pilot study
Purpose: The aim of this pilot study was to evaluate the knowledge and perception among dental educators regarding the use of relative value units (RVUs) in medicine, perceived benefits in dentistry, and the relative ranking of the components to define RVUs in dentistry.Methods: A convenience sample of dental educators participating in the American Dental Education Association's Leadership Institute (2023–2024) cohort was surveyed for their knowledge and perception regarding RVUs. The responses were stratified based on experience with RVUs prior to statistical analyses (α = 0.05).Results: Twenty‐six dental educators from 18 different North American dental schools and nine different dental specialties participated in this pilot study. Although not significant, a higher proportion of dental educators with prior experience perceived RVUs as a valuable tool in dental practice for assigning chair time, developing payment models, and tracking student–resident progress in a clinical course. There was a lack of consensus among dental educators regarding the components for determining dental procedural RVUs.Conclusion: This pilot study provides limited evidence that prior knowledge of RVUs may be related to its perceived benefits among dental educators, but a broader study design is needed to draw meaningful conclusions and universally acceptable components for determining RVUs in dentistry.
- 27 October 2024
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (4) , 920-933
Clinical Outcomes of Bulk‐Fill Resin Composite Restorations: A 10‐Year Mapping Review and Evidence Gap Map
Objective: To map the evidence regarding the clinical performance of posterior restorations with bulk‐fill resin composites and identify research gaps.Materials and Methods: This mapping review was conducted following PRISMA‐ScR guidelines for scoping reviews, and its protocol was registered on the Open Science Framework platform. Systematic searches were conducted, considering studies published between 2013 and February 2024 in the PubMed, Embase, and Cochrane databases. Clinical studies investigating the performance of bulk‐fill resin composite restorations in class I and/or class II preparations with increments of 4 to 5 mm were included.Results: A total of 147 articles were identified, and based on the eligibility criteria, 26 studies were selected for descriptive analysis. Of the reviewed studies, 73% (n = 19) investigated high‐viscosity bulk‐fill composites, while 30% (n = 8) focused on low‐viscosity bulk‐fill composites. Evaluation periods ranged from 1 week to 10 years. Reported annual failure rates varied from 0% to 3%, with survival rates between 78.9% and 100%.Conclusions: Bulk‐fill resin composites of high viscosity were the most analyzed in the published studies, with evaluation periods of up to 10 years. The review of available scientific evidence showed clinically acceptable performance for composite bulk‐fill restorations, with high survival rates and minimal annual failure rates. There is a need for long‐term clinical studies on bulk‐fill resin composites.Clinical Significance: This review demonstrates that both high and low‐viscosity bulk‐fill resin composites exhibit satisfactory clinical performance, which can help clinicians optimize chairside time. However, it is important to highlight the need for further studies with longer follow‐up periods.
- 27 October 2024
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (4) , 920-933
Clinical Outcomes of Bulk‐Fill Resin Composite Restorations: A 10‐Year Mapping Review and Evidence Gap Map
Objective: To map the evidence regarding the clinical performance of posterior restorations with bulk‐fill resin composites and identify research gaps.Materials and Methods: This mapping review was conducted following PRISMA‐ScR guidelines for scoping reviews, and its protocol was registered on the Open Science Framework platform. Systematic searches were conducted, considering studies published between 2013 and February 2024 in the PubMed, Embase, and Cochrane databases. Clinical studies investigating the performance of bulk‐fill resin composite restorations in class I and/or class II preparations with increments of 4 to 5 mm were included.Results: A total of 147 articles were identified, and based on the eligibility criteria, 26 studies were selected for descriptive analysis. Of the reviewed studies, 73% (n = 19) investigated high‐viscosity bulk‐fill composites, while 30% (n = 8) focused on low‐viscosity bulk‐fill composites. Evaluation periods ranged from 1 week to 10 years. Reported annual failure rates varied from 0% to 3%, with survival rates between 78.9% and 100%.Conclusions: Bulk‐fill resin composites of high viscosity were the most analyzed in the published studies, with evaluation periods of up to 10 years. The review of available scientific evidence showed clinically acceptable performance for composite bulk‐fill restorations, with high survival rates and minimal annual failure rates. There is a need for long‐term clinical studies on bulk‐fill resin composites.Clinical Significance: This review demonstrates that both high and low‐viscosity bulk‐fill resin composites exhibit satisfactory clinical performance, which can help clinicians optimize chairside time. However, it is important to highlight the need for further studies with longer follow‐up periods.