MDMarius Dettmer

Marius Dettmer

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marius Dettmer has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of Patient-Reported Outcomes of Total Hip Arthroplasty between a Neck-Preserving Short-Stem Implant and a Conventional Neck-Sacrificing Implant

    by Stefany J. K. Malanka, Marius Dettmer, Amir Pourmoghaddam, Mitchell Veverka, Stefan W. Kreuzer

    Femoral neck-preserving short- (NPS) stem implants for total hip arthroplasty (THA) bear several advantages over longer-stem implants, such as native hip structure preservation and improved physiological loading. However, there still is a gap of knowledge regarding the potential benefits of a short-stem design over conventional neck-sacrificing stems in regards to patient-reported outcomes (PROs). The authors investigated the differences in PROs between a neck-sacrificing stem design and NPS stem design arthroplasty. They hypothesized that PROs of NPS stem THA would be higher in the medium-term in comparison to the neck-sacrificing implant system. Neck-sacrificing implant patients (n = 90, age 57 ± 7.9 years) and a matched (body mass index [BMI], age) cohort group of NPS implant patients (n = 105, age 55.2 ± 9.9 years) reported both preoperative and postoperative hip disability and osteoarthritis outcome scores (HOOS). Average follow-up was 413 ± 207 days (neck sacrificing implant) and 454 ± 226 days (NPS implant). The authors applied multivariate analysis of variance (MANOVA) and Mann–Whitney tests for statistical analyses. Significance levels were Holm–Bonferroni adjusted for multiple comparisons. HOOS Subscores increased significantly after surgery independent of implant type (p < 0.001). There was a significant time by surgery interaction (p = 0.02). Follow-up HOOS subscores were significantly higher in the NPS implant group: symptoms (p < 0.001), pain (p < 0.001), activities of daily living (ADL; p = 0.011), sports and recreation (p = 0.011), and quality of life (QOL; p = 0.007). While long-term studies are required for further investigation, evidence from the current study suggests that NPS implants may provide a significant benefit to primary THA patients, which could be due to physiological loading advantages or retention of bone tissue.


  • Assessing multiple muscle activation during squat movements with different loading conditions – an EMG study

    by Amir Pourmoghaddam, Marius Dettmer, Stefany J.K. Malanka, Mitchell Veverka, Daniel P. O’connor, William H. Paloski, Charles S. Layne

    Surface electromyography (EMG) is a valuable tool in clinical diagnostics and research related to human neuromotor control. Non-linear analysis of EMG data can help with detection of subtle changes of control due to changes of external or internal constraints during motor tasks. However, non-linear analysis is complex and results may be difficult to interpret, particularly in clinical environments. We developed a non-linear analysis tool (SYNERGOS) that evaluates multiple muscle activation (MMA) features and provides a single value for description of activation characteristics. To investigate the responsiveness of SYNERGOS to kinetic changes during cyclic movements, 13 healthy young adults performed squat movements under different loading conditions (100%–120% of body weight). We processed EMG data to generate SYNERGOS indices and used two-way repeated measures ANOVA to determine changes of MMA in response to loading conditions during movement. SYNERGOS values were significantly different for each loading condition. We concluded that the algorithm is sensitive to kinetic changes during cyclic movements, which may have implications for applications in a variety of experimental and diagnostic settings.

  • Open Access

    Do Aging and Tactile Noise Stimulation Affect Responses to Support Surface Translations in Healthy Adults?

    by Marius Dettmer, Amir Pourmoghaddam, Beom-Chan Lee, Charles S. Layne

    Appropriate neuromuscular responses to support surface perturbations are crucial to prevent falls, but aging-related anatomical and physiological changes affect the appropriateness and efficiency of such responses. Low-level noise application to sensory receptors has shown to be effective for postural improvement in a variety of different balance tasks, but it is unknown whether this intervention may have value for improvement of corrective postural responses. Ten healthy younger and ten healthy older adults were exposed to sudden backward translations of the support surface. Low-level noise (mechanical vibration) to the foot soles was added during random trials and temporal (response latency) and spatial characteristics (maximum center-of-pressure excursion and anterior-posterior path length) of postural responses were assessed. Mixed-model ANOVA was applied for analysis of postural response differences based on age and vibration condition. Age affected postural response characteristics, but older adults were well able to maintain balance when exposed to a postural perturbation. Low-level noise application did not affect any postural outcomes. Healthy aging affects some specific measures of postural stability, and in high-functioning older individuals, a low-level noise intervention may not be valuable. More research is needed to investigate if recurring fallers and neuropathy patients could benefit from the intervention in postural perturbation tasks.


  • Open Access

    Associations between Tactile Sensory Threshold and Postural Performance and Effects of Healthy Aging and Subthreshold Vibrotactile Stimulation on Postural Outcomes in a Simple Dual Task

    by Marius Dettmer, Amir Pourmoghaddam, Beom-Chan Lee, Charles S. Layne

    Specific activities that require concurrent processing of postural and cognitive tasks may increase the risk for falls in older adults. We investigated whether peripheral receptor sensitivity was associated with postural performance in a dual-task and whether an intervention in form of subthreshold vibration could affect performance. Ten younger (age: 20–35 years) and ten older adults (70–85 years) performed repeated auditory-verbal 1-back tasks while standing quietly on a force platform. Foot sole vibration was randomly added during several trials. Several postural control and performance measures were assessed and statistically analyzed (significance set toα-levels of .05). There were moderate correlations between peripheral sensitivity and several postural performance and control measures (r=.45to .59). Several postural performance measures differed significantly between older and younger adults (p<0.05); addition of vibration did not affect outcome measures. Aging affects healthy older adults’ performance in dual-tasks, and peripheral sensitivity may be a contributor to the observed differences. A vibration intervention may only be useful when there are more severe impairments of the sensorimotor system. Hence, future research regarding the efficacy of sensorimotor interventions in the form of vibrotactile stimulation should focus on older adults whose balance is significantly affected.


  • Open Access

    Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study

    by Stefan W. Kreuzer, Amir Pourmoghaddam, Kevin J. Leffers, Clint W. Johnson, Marius Dettmer

    Rotation of the femoral component is an important aspect of knee arthroplasty, due to its effects on postsurgery knee kinematics and associated functional outcomes. It is still debated which method for establishing rotational alignment is preferable in orthopedic surgery. We compared force sensing based femoral component rotation with traditional anatomic landmark methods to investigate which method is more accurate in terms of alignment to the true transepicondylar axis. Thirty-one patients underwent computer-navigated total knee arthroplasty for osteoarthritis with femoral rotation established via a force sensor. During surgery, three alternative hypothetical femoral rotational alignments were assessed, based on transepicondylar axis, anterior-posterior axis, or the utilization of a posterior condyles referencing jig. Postoperative computed tomography scans were obtained to investigate rotation characteristics. Significant differences in rotation characteristics were found between rotation according to DKB and other methods (). Soft tissue balancing resulted in smaller deviation from anatomical epicondylar axis than any other method. 77% of operated knees were within a range of ±3° of rotation. Only between 48% and 52% of knees would have been rotated appropriately using the other methods. The current results indicate that force sensors may be valuable for establishing correct femoral rotation. Rotation of the femoral component is an important aspect of knee arthroplasty, due to its effects on postsurgery knee kinematics and associated functional outcomes. It is still debated which method for establishing rotational alignment is preferable in orthopedic surgery. We compared force sensing based femoral component rotation with traditional anatomic landmark methods to investigate which method is more accurate in terms of alignment to the true transepicondylar axis. Thirty-one patients underwent computer-navigated total knee arthroplasty for osteoarthritis with femoral rotation established via a force sensor. During surgery, three alternative hypothetical femoral rotational alignments were assessed, based on transepicondylar axis, anterior-posterior axis, or the utilization of a posterior condyles referencing jig. Postoperative computed tomography scans were obtained to investigate rotation characteristics. Significant differences in rotation characteristics were found between rotation according to DKB and other methods (). Soft tissue balancing resulted in smaller deviation from anatomical epicondylar axis than any other method. 77% of operated knees were within a range of ±3° of rotation. Only between 48% and 52% of knees would have been rotated appropriately using the other methods. The current results indicate that force sensors may be valuable for establishing correct femoral rotation.


  • Measuring multiple neuromuscular activation using EMG – a generalizability analysis

    by Amir Pourmoghaddam, Marius Dettmer, Daniel P. O’cOnnor, William H. Paloski, Charles S. Layne

    Analysis of electromyography (EMG) data has been shown to be valuable in biomedical and clinical research. However, most analysis tools do not consider the non-linearity of EMG data or the synergistic effects of multiple neuromuscular activities. The SYNERGOS algorithm was developed to assess a single index based on non-linear analysis of multiple neuromuscular activation (MNA) of different muscles. This index has shown promising results in Parkinsonian gait, but it was yet to be explored whether the SYNERGOS index is generalizable. In this study, we evaluated generalizability of the SYNERGOS index over the course of several trials and over separate days with different walking speeds. Ten healthy adults aged from 18 to 40 years walked on a treadmill on two different days, while EMG data was collected from the upper and lower right leg. SYNERGOS indices were obtained and a generalizability analysis was conducted. The algorithm detected changes in MNA in response to altering gait speed and depicted a high generalizability coefficient (


  • Open Access

    Comparison of Patient-Reported Outcome from Neck-Preserving, Short-Stem Arthroplasty and Resurfacing Arthroplasty in Younger Osteoarthritis Patients

    by Marius Dettmer, Amir Pourmoghaddam, Stefan W. Kreuzer

    Hip resurfacing has been considered a good treatment option for younger, active osteoarthritis patients. However, there are several identified issues concerning risk for neck fractures and issues related to current metal-on-metal implant designs. Neck-preserving short-stem implants have been discussed as a potential alternative, but it is yet unclear which method is better suited for younger adults. We compared hip disability and osteoarthritis outcome scores (HOOS) from a young group of patients (n=52, age 48.9 ± 6.1 years) who had received hip resurfacing (HR) with a cohort of patients (n=73, age 48.2 ± 6.6 years) who had received neck-preserving, short-stem implant total hip arthroplasty (THA). Additionally, durations for both types of surgery were compared. HOOS improved significantly preoperatively to last followup (>1 year) in both groups (p<0.0001,η2=0.69); there were no group effects or interactions. Surgery duration was significantly longer for resurfacing (104.4 min ± 17.8) than MiniHip surgery (62.5 min ± 14.8),U=85.0,p<0.0001,η2=0.56. The neck-preserving short-stem approach may be preferable to resurfacing due to the less challenging surgery, similar outcome, and controversy regarding resurfacing implant designs.


  • Open Access

    Identification of Changing Lower Limb Neuromuscular Activation in Parkinson’s Disease during Treadmill Gait with and without Levodopa Using a Nonlinear Analysis Index

    by Amir Pourmoghaddam, Marius Dettmer, Daniel P. O’cOnnor, William H. Paloski, Charles S. Layne

    Analysis of electromyographic (EMG) data is a cornerstone of research related to motor control in Parkinson’s disease. Nonlinear EMG analysis tools have shown to be valuable, but analysis is often complex and interpretation of the data may be difficult. A previously introduced algorithm (SYNERGOS) that provides a single index value based on simultaneous multiple muscle activations (MMA) has been shown to be effective in detecting changes in EMG activation due to modifications of walking speeds in healthy adults. In this study, we investigated if SYNERGOS detects MMA changes associated with both different walking speeds and levodopa intake. Nine male Parkinsonian patients walked on a treadmill with increasing speed while on or off medication. We collected EMG data and computed SYNERGOS indices and employed a restricted maximum likelihood linear mixed model to the values. SYNERGOS was sensitive to neuromuscular modifications due to both alterations of gait speed and intake of levodopa. We believe that the current experiment provides evidence for the potential value of SYNERGOS as a nonlinear tool in clinical settings, by providing a single value index of MMA. This could help clinicians to evaluate the efficacy of interventions and treatments in Parkinson’s disease in a simple manner.