Marian Miculescu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marian Miculescu has a total of 133 co-authors. Here are the top co-authors by number of shared publications:
- Florin Miculescu
Faculty of Material Science and Engineering, National University of Science and Technology Politehnica Bucharest, 011061 Bucharest, Romania
19 shared publications - Iulian Antoniac
Faculty of Material Science and Engineering, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania
16 shared publications - Aura-Cătălina Mocanu
Department of Metallic Materials Science, Physical Metallurgy, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, J Building, District 6, 060042 Bucharest, Romania
10 shared publications - George E. Stan
National Institute of Materials Physics Magurele Romania
9 shared publications - Andreea Maidaniuc
University Politehnica of Bucharest
8 shared publications - Lucian Toma Ciocan
Discipline of Dental Prosthesis Technology, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, Dionisie Lupu Street, No. 37, District 2, 020021 Bucharest, Romania
8 shared publications
Latest Publications
- Open Access
- 2 April 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (4) , 204
Dimensional Stability of SLA 3D-Printed Surgical Guide Resin After Steam Sterilization (121 °C and 134 °C) and Isopropyl Alcohol Disinfection: An In Vitro Study
Background: Additively manufactured surgical guides require post-processing and subsequent decontamination prior to intraoral use. Steam sterilization and chemical disinfection protocols may influence the dimensional stability of polymer-based guide materials and potentially affect clinical fit and accuracy. Objectives: This in vitro study evaluated the dimensional changes of SLA 3D-printed Surgical Guide Resin V1 (Formlabs) after steam sterilization at 121 °C (AUT121) and 134 °C (AUT134) and after disinfection using 70% isopropyl alcohol (IPA70), compared with an untreated control group. Methods: Forty standardized specimens were fabricated using SLA technology and divided into four groups (n = 10/group): Control (CT), 121 °C steam sterilization (AUT121), 134 °C steam sterilization (AUT134), and IPA70 disinfection. Two linear measurement zones (L1 and L2) were assessed per specimen. Baseline measurements were recorded with a caliper (mm). Post-treatment measurements were obtained using microscopic evaluation, recorded in µm, and converted to mm for analysis. Dimensional change was calculated as ΔL = L_after − L_before. Within-group comparisons and between-group analyses were performed with a significance level of α = 0.05. Results: Steam sterilization at 134 °C (AUT 134) produced statistically significant dimensional changes in both zones (L1: p = 0.036; L2: p = 0.042). No statistically significant differences were observed in the AUT121 group (L1: p = 0.437; L2: p = 0.682) or the IPA70 group (L1: p = 0.164; L2: p = 0.086). Between-group analysis showed no significant differences for ΔL1 (p = 0.345), whereas ΔL2 differed significantly among groups (p = 0.021). Conclusions: Under the conditions of this study, AUT134 steam sterilization significantly affected the dimensional stability of SLA-printed Surgical Guide Resin V1 specimens. The AUT121 protocol and IPA70 disinfection did not result in statistically significant dimensional changes compared with baseline.
- 2 April 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (4) , 204
Open AccessDimensional Stability of SLA 3D-Printed Surgical Guide Resin After Steam Sterilization (121 °C and 134 °C) and Isopropyl Alcohol Disinfection: An In Vitro Study
Background: Additively manufactured surgical guides require post-processing and subsequent decontamination prior to intraoral use. Steam sterilization and chemical disinfection protocols may influence the dimensional stability of polymer-based guide materials and potentially affect clinical fit and accuracy. Objectives: This in vitro study evaluated the dimensional changes of SLA 3D-printed Surgical Guide Resin V1 (Formlabs) after steam sterilization at 121 °C (AUT121) and 134 °C (AUT134) and after disinfection using 70% isopropyl alcohol (IPA70), compared with an untreated control group. Methods: Forty standardized specimens were fabricated using SLA technology and divided into four groups (n = 10/group): Control (CT), 121 °C steam sterilization (AUT121), 134 °C steam sterilization (AUT134), and IPA70 disinfection. Two linear measurement zones (L1 and L2) were assessed per specimen. Baseline measurements were recorded with a caliper (mm). Post-treatment measurements were obtained using microscopic evaluation, recorded in µm, and converted to mm for analysis. Dimensional change was calculated as ΔL = L_after − L_before. Within-group comparisons and between-group analyses were performed with a significance level of α = 0.05. Results: Steam sterilization at 134 °C (AUT 134) produced statistically significant dimensional changes in both zones (L1: p = 0.036; L2: p = 0.042). No statistically significant differences were observed in the AUT121 group (L1: p = 0.437; L2: p = 0.682) or the IPA70 group (L1: p = 0.164; L2: p = 0.086). Between-group analysis showed no significant differences for ΔL1 (p = 0.345), whereas ΔL2 differed significantly among groups (p = 0.021). Conclusions: Under the conditions of this study, AUT134 steam sterilization significantly affected the dimensional stability of SLA-printed Surgical Guide Resin V1 specimens. The AUT121 protocol and IPA70 disinfection did not result in statistically significant dimensional changes compared with baseline.
- Open Access
- 7 January 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (1) , 40
In Vitro Evaluation of Surface and Mechanical Behavior of 3D-Printed PMMA After Accelerated and Chemical Aging Under Simulated Oral Conditions
Studying surface energy and permeability offers insights into the relationship between temporary polymers and the oral environment. Variations in contact angle and surface free energy may signify modifications in surface polarity and tendency for plaque buildup, staining, or microcrack formation. Objectives: The present study aims to evaluate the influence of simulated salivary and chemical aging conditions on the surface and mechanical properties of 3D-printed PMMA provisional materials. Methods: Two 3D-printed polymethyl methacrylate (PMMA) resins were investigated, namely Anycubic White (Anycubic, Shenzhen, China) and NextDent Creo (NextDent, 3D Systems, Soesterberg, The Netherlands), using two aging protocols. Protocol A consisted of chemical aging in an alcohol-based mouthwash, while Protocol B involved thermal aging in artificial saliva. After aging, surface properties (wettability and SFE) and compressive behaviour were analyzed. Statistical analysis was conducted to assess the influence of temperature, immersion duration, and aging medium, with significance established at p < 0.05. Results: In Protocol A, mechanical properties showed a time-dependent decrease, with material-specific stabilization trends. In Protocol B, thermal aging resulted in elastic modulus reductions ranging from 35% to 46% relative to the reference. The yield strength exhibited similar tendencies. In Protocol A, X samples exhibited a consistent decline, while C samples stabilized after 14 days. For Protocol B, the fitted model produced residuals under 2%, confirming temperature as the primary variable. Conclusions: Chemical and thermal aging influence the physical and mechanical properties of the analyzed 3D-printed PMMA. Among the two protocols, thermal aging in artificial saliva resulted in more pronounced material degradation. After chemical aging in mouthwash, the surface free energy remained almost constant. After thermal aging, all samples demonstrated a gradual rise in SFE with prolonged immersion duration. The current study offers valuable insights into the environmental stability of printed PMMA; however, it is an in vitro evaluation. The findings indicate that temperature exposure and prolonged contact with oral hygiene products may affect the mechanical reliability of 3D-printed provisional restorations, which must be considered during material selection for longer temporary usage. Additionally, spectroscopic and microscopic analyses might better clarify the molecular-level chemical alterations linked to aging.
- 7 January 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (1) , 40
Open AccessIn Vitro Evaluation of Surface and Mechanical Behavior of 3D-Printed PMMA After Accelerated and Chemical Aging Under Simulated Oral Conditions
Studying surface energy and permeability offers insights into the relationship between temporary polymers and the oral environment. Variations in contact angle and surface free energy may signify modifications in surface polarity and tendency for plaque buildup, staining, or microcrack formation. Objectives: The present study aims to evaluate the influence of simulated salivary and chemical aging conditions on the surface and mechanical properties of 3D-printed PMMA provisional materials. Methods: Two 3D-printed polymethyl methacrylate (PMMA) resins were investigated, namely Anycubic White (Anycubic, Shenzhen, China) and NextDent Creo (NextDent, 3D Systems, Soesterberg, The Netherlands), using two aging protocols. Protocol A consisted of chemical aging in an alcohol-based mouthwash, while Protocol B involved thermal aging in artificial saliva. After aging, surface properties (wettability and SFE) and compressive behaviour were analyzed. Statistical analysis was conducted to assess the influence of temperature, immersion duration, and aging medium, with significance established at p < 0.05. Results: In Protocol A, mechanical properties showed a time-dependent decrease, with material-specific stabilization trends. In Protocol B, thermal aging resulted in elastic modulus reductions ranging from 35% to 46% relative to the reference. The yield strength exhibited similar tendencies. In Protocol A, X samples exhibited a consistent decline, while C samples stabilized after 14 days. For Protocol B, the fitted model produced residuals under 2%, confirming temperature as the primary variable. Conclusions: Chemical and thermal aging influence the physical and mechanical properties of the analyzed 3D-printed PMMA. Among the two protocols, thermal aging in artificial saliva resulted in more pronounced material degradation. After chemical aging in mouthwash, the surface free energy remained almost constant. After thermal aging, all samples demonstrated a gradual rise in SFE with prolonged immersion duration. The current study offers valuable insights into the environmental stability of printed PMMA; however, it is an in vitro evaluation. The findings indicate that temperature exposure and prolonged contact with oral hygiene products may affect the mechanical reliability of 3D-printed provisional restorations, which must be considered during material selection for longer temporary usage. Additionally, spectroscopic and microscopic analyses might better clarify the molecular-level chemical alterations linked to aging.
- Open Access
Formation and Characterization of Ti-Al Intermetallic and Oxide Layers on Ti6Al4V as Interlayers for Hydroxyapatite Coatings
This study explores a novel approach to enhance the surface properties of Ti-Al alloys for biomedical applications by creating a compositional gradient layer through aluminum deposition using Electrical Discharge Machining (EDM). The primary goal was to develop a metallurgically bonded intermetallic zone that supports strong adhesion and improved compatibility for subsequent hydroxyapatite (HA) deposition. Aluminum was deposited onto a Ti6Al4V substrate via EDM under controlled conditions, followed by thermal and thermochemical treatments to induce diffusion and intermetallic phase formation. Comprehensive analyses using optical and electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and X-ray diffraction (XRD) revealed the formation of well-adhered layers composed of complex Ti-Al intermetallics such as TiAl2 and TiAl3, along with oxide phases including TiO2 and Al2O3. Thermal and thermochemical treatments further improved surface hardness, reaching up to 1057 HV, and influenced the diffusion behavior of aluminum, titanium, and vanadium. Adhesion tests confirmed that the untreated and thermochemically treated layers exhibited superior mechanical stability, while thermal treatment alone led to brittleness and delamination. These findings demonstrate that a properly engineered intermediate aluminide layer can significantly improve the performance of bioceramic coatings, particularly HA, by providing enhanced structural integrity and biocompatibility.
Open AccessFormation and Characterization of Ti-Al Intermetallic and Oxide Layers on Ti6Al4V as Interlayers for Hydroxyapatite Coatings
This study explores a novel approach to enhance the surface properties of Ti-Al alloys for biomedical applications by creating a compositional gradient layer through aluminum deposition using Electrical Discharge Machining (EDM). The primary goal was to develop a metallurgically bonded intermetallic zone that supports strong adhesion and improved compatibility for subsequent hydroxyapatite (HA) deposition. Aluminum was deposited onto a Ti6Al4V substrate via EDM under controlled conditions, followed by thermal and thermochemical treatments to induce diffusion and intermetallic phase formation. Comprehensive analyses using optical and electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and X-ray diffraction (XRD) revealed the formation of well-adhered layers composed of complex Ti-Al intermetallics such as TiAl2 and TiAl3, along with oxide phases including TiO2 and Al2O3. Thermal and thermochemical treatments further improved surface hardness, reaching up to 1057 HV, and influenced the diffusion behavior of aluminum, titanium, and vanadium. Adhesion tests confirmed that the untreated and thermochemically treated layers exhibited superior mechanical stability, while thermal treatment alone led to brittleness and delamination. These findings demonstrate that a properly engineered intermediate aluminide layer can significantly improve the performance of bioceramic coatings, particularly HA, by providing enhanced structural integrity and biocompatibility.
- Open Access
Women in STEM in the Eastern Partnership: EU-Driven Initiatives and Challenges of External Europeanisation
This article explores the role of the European Union (EU) as a normative gender actor promoting women’s participation in STEM (Science, Technology, Engineering, and Mathematics) within the Eastern Partnership (EaP) region. In a context marked by global inequality and overlapping international efforts, this paper assesses the extent to which EU-driven Europeanisation influences national gender policies in non-EU states. Using a postfunctionalist lens, this research draws on a qualitative analysis of EU-funded programmes, strategic documents, and a detailed case study encompassing Armenia, Georgia, Moldova, Ukraine, Belarus, and Azerbaijan. This study highlights both the opportunities created by EU initiatives such as Horizon Europe, Erasmus+, and regional programmes like EU4Digital and the challenges presented by political resistance, institutional inertia, and socio-cultural norms. The findings reveal that although EU interventions have fostered significant progress, structural barriers and limited national commitment hinder the long-term sustainability of gender equality in STEM. Moreover, the withdrawal of other global actors increases pressure on the EU to maintain leadership in this area. This paper concludes that without stronger national alignment and global cooperation, EU gender policies risk becoming symbolic rather than transformative.
Open AccessWomen in STEM in the Eastern Partnership: EU-Driven Initiatives and Challenges of External Europeanisation
This article explores the role of the European Union (EU) as a normative gender actor promoting women’s participation in STEM (Science, Technology, Engineering, and Mathematics) within the Eastern Partnership (EaP) region. In a context marked by global inequality and overlapping international efforts, this paper assesses the extent to which EU-driven Europeanisation influences national gender policies in non-EU states. Using a postfunctionalist lens, this research draws on a qualitative analysis of EU-funded programmes, strategic documents, and a detailed case study encompassing Armenia, Georgia, Moldova, Ukraine, Belarus, and Azerbaijan. This study highlights both the opportunities created by EU initiatives such as Horizon Europe, Erasmus+, and regional programmes like EU4Digital and the challenges presented by political resistance, institutional inertia, and socio-cultural norms. The findings reveal that although EU interventions have fostered significant progress, structural barriers and limited national commitment hinder the long-term sustainability of gender equality in STEM. Moreover, the withdrawal of other global actors increases pressure on the EU to maintain leadership in this area. This paper concludes that without stronger national alignment and global cooperation, EU gender policies risk becoming symbolic rather than transformative.
- Open Access
- 9 April 2025
- Published by Romanian Association of Oral Rehabilitation in Romanian Journal of Oral Rehabilitation
- Vol. 17 (1) , 637-653
COMPARATIVE EVALUATIONS OF POLYMERIZATION SHRINKAGE OF LIGHT CURING COMPOSITE RESINS
Aim of the study Composite resins are a class of dental materials widely used in dentistry. This paper aims to present the most important general aspects related to dental composites, focusing on the effects of the polymerization reaction. Materials and methods for this purpose, the rate of shrinkage after photopolymerization was tested and measured for composite materials from two different manufacturing companies. Results The results obtained in the present study compare the linear shrinkage between different light-curing composite materials, this being attributed to the consistency and composition of the material, information provided by the manufacturer. These results are indicative for the clinician and can guide his choice depending on the clinical situation Conclusions The idea of an ideal material, which meets all the requirements of clinicians and can be integrated into the complexity of the human body, seems a difficult goal to achieve, but through the continuous development of technology and science, more and more sustainable results can be achieved in time.
- 9 April 2025
- Published by Romanian Association of Oral Rehabilitation in Romanian Journal of Oral Rehabilitation
- Vol. 17 (1) , 637-653
Open AccessCOMPARATIVE EVALUATIONS OF POLYMERIZATION SHRINKAGE OF LIGHT CURING COMPOSITE RESINS
Aim of the study Composite resins are a class of dental materials widely used in dentistry. This paper aims to present the most important general aspects related to dental composites, focusing on the effects of the polymerization reaction. Materials and methods for this purpose, the rate of shrinkage after photopolymerization was tested and measured for composite materials from two different manufacturing companies. Results The results obtained in the present study compare the linear shrinkage between different light-curing composite materials, this being attributed to the consistency and composition of the material, information provided by the manufacturer. These results are indicative for the clinician and can guide his choice depending on the clinical situation Conclusions The idea of an ideal material, which meets all the requirements of clinicians and can be integrated into the complexity of the human body, seems a difficult goal to achieve, but through the continuous development of technology and science, more and more sustainable results can be achieved in time.
- Open Access
Parameters Tailoring on the Deposition of Hydroxyapatite by Pulsed Electrical Discharge
The creation of strong adhesive layers of hydroxyapatite-based bioceramics (with or without bioinert metals, such as Ta, Ag, and Ti) on biocompatible metallic supports enhances the local biofunctionalization of surfaces. The processing of electroconductive materials using electrical impulse discharges is versatile, enabling precise coating of selected areas with perfectly adherent layers of varying thicknesses. This study aims to quantify the effects of varying the electrical power from the source generating the impulse discharge and the specific processing time per unit area of the cathode (made of titanium alloy) on the relative mass increase of the cathode. The anode comprised a mixture of hydroxyapatite powder and a self-polymerizing electroconductive acrylic resin in a tantalum sheath. The effects of the parameter adjustments on single-layer deposition adherence were quantified using a central composite design to build a second-order orthogonal model. The most significant difference in relative mass was observed with a low-power source (5 W) ensuring the electrical discharge impulse, combined with the longest specified surface treatment time (17.5 s/cm2 on a 4 cm2 surface) for a single layer presenting the largest mass increase of 0.153% of the original mass. This study aimed to enhance the performance of medical implants by optimizing surface biofunctionalization through robust hydroxyapatite-based bioceramic adhesive layers on metallic supports, determining the optimal electrical power and processing time for cathode mass increase during deposition processes, and analyzing parameter adjustments using second-order statistical orthogonal central composite programming, with a focus on single-layer deposition to identify significant differences in relative mass under specific conditions.
Open AccessParameters Tailoring on the Deposition of Hydroxyapatite by Pulsed Electrical Discharge
The creation of strong adhesive layers of hydroxyapatite-based bioceramics (with or without bioinert metals, such as Ta, Ag, and Ti) on biocompatible metallic supports enhances the local biofunctionalization of surfaces. The processing of electroconductive materials using electrical impulse discharges is versatile, enabling precise coating of selected areas with perfectly adherent layers of varying thicknesses. This study aims to quantify the effects of varying the electrical power from the source generating the impulse discharge and the specific processing time per unit area of the cathode (made of titanium alloy) on the relative mass increase of the cathode. The anode comprised a mixture of hydroxyapatite powder and a self-polymerizing electroconductive acrylic resin in a tantalum sheath. The effects of the parameter adjustments on single-layer deposition adherence were quantified using a central composite design to build a second-order orthogonal model. The most significant difference in relative mass was observed with a low-power source (5 W) ensuring the electrical discharge impulse, combined with the longest specified surface treatment time (17.5 s/cm2 on a 4 cm2 surface) for a single layer presenting the largest mass increase of 0.153% of the original mass. This study aimed to enhance the performance of medical implants by optimizing surface biofunctionalization through robust hydroxyapatite-based bioceramic adhesive layers on metallic supports, determining the optimal electrical power and processing time for cathode mass increase during deposition processes, and analyzing parameter adjustments using second-order statistical orthogonal central composite programming, with a focus on single-layer deposition to identify significant differences in relative mass under specific conditions.
- Open Access
- 4 November 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (7) , 526
In Vitro Studies Regarding the Effect of Cellulose Acetate-Based Composite Coatings on the Functional Properties of the Biodegradable Mg3Nd Alloys
Magnesium (Mg) alloys are adequate materials for orthopedic and maxilo-facial implants due to their biocompatibility, good mechanical properties closely related to the hard tissues, and processability. Their main drawbacks are the high-speed corrosion process and hydrogen release. In order to improve corrosion and mechanical properties, the Mg matrix can be strengthened through alloying elements with high temperature-dependent solubility materials. Rare earth elements (RE) contribute to mechanical properties and degradation improvement. Another possibility to reduce the corrosion rate of Mg-based alloys was demonstrated to be the different types of coatings (bioceramics, polymers, and composites) applied on their surface. The present investigation is related to the coating of two Mg-based alloys from the system Mg3Nd (Mg-Nd-Y-Zr-Zn) with polymeric-based composite coatings made from cellulose acetate (CA) combined with two fillers, respectively hydroxyapatite (HAp) and Mg particles. The main functions of the coatings are to reduce the biodegradation rate and to modify the surface properties in order to increase osteointegration. Firstly, the microstructural features of the experimental Mg3Nd alloys were revealed by optical microscopy and scanning electron microscopy (SEM) coupled with energy-dispersive spectroscopy. Apart from the surface morphology revealed by SEM, the roughness and wettability of all experimental samples were evaluated. The corrosion behavior of the uncoated and coated samples of both Mg3Nd alloys was investigated by immersion testing and electrochemical testing using Simulated Body Fluid as the medium. The complex in vitro research performed highlights that the composite coating based on CA with HAp particles exhibited the best protective effect for both Mg3Nd alloys.
- 4 November 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (7) , 526
Open AccessIn Vitro Studies Regarding the Effect of Cellulose Acetate-Based Composite Coatings on the Functional Properties of the Biodegradable Mg3Nd Alloys
Magnesium (Mg) alloys are adequate materials for orthopedic and maxilo-facial implants due to their biocompatibility, good mechanical properties closely related to the hard tissues, and processability. Their main drawbacks are the high-speed corrosion process and hydrogen release. In order to improve corrosion and mechanical properties, the Mg matrix can be strengthened through alloying elements with high temperature-dependent solubility materials. Rare earth elements (RE) contribute to mechanical properties and degradation improvement. Another possibility to reduce the corrosion rate of Mg-based alloys was demonstrated to be the different types of coatings (bioceramics, polymers, and composites) applied on their surface. The present investigation is related to the coating of two Mg-based alloys from the system Mg3Nd (Mg-Nd-Y-Zr-Zn) with polymeric-based composite coatings made from cellulose acetate (CA) combined with two fillers, respectively hydroxyapatite (HAp) and Mg particles. The main functions of the coatings are to reduce the biodegradation rate and to modify the surface properties in order to increase osteointegration. Firstly, the microstructural features of the experimental Mg3Nd alloys were revealed by optical microscopy and scanning electron microscopy (SEM) coupled with energy-dispersive spectroscopy. Apart from the surface morphology revealed by SEM, the roughness and wettability of all experimental samples were evaluated. The corrosion behavior of the uncoated and coated samples of both Mg3Nd alloys was investigated by immersion testing and electrochemical testing using Simulated Body Fluid as the medium. The complex in vitro research performed highlights that the composite coating based on CA with HAp particles exhibited the best protective effect for both Mg3Nd alloys.
- Open Access
Comparative Study on Interface Fracture of 4th Generation 3-Steps Adhesive and 7th Generation Universal Adhesive
The purpose of this paper is to compare the fracture behavior of interfaces obtained using fourth-generation and universal dental adhesives. The study relies on optic and SEM to evaluate the dentin–adhesive–restoration material interface of the samples and also on FEA simulation of fracture behavior. Specimen fabrication relied on 20 extracted teeth, in which class I cavities were created according to a protocol established based on the rules of minimally invasive therapy. For the direct adhesive technique, the adhesives used were: three-step All Bond, three-batch A and one-step Clearfil Universal Bond Quick-batch B. The restoration was performed with the same composite for both adhesives: Gradia direct posterior. The simulation used a 3D reconstructed molar on which geometric operations were performed to obtain an assembly that replicated a physical specimen. Material properties were applied to each component based on the information found in the literature. A simplified model for crack propagation was constructed, and using the fracture mechanics tool in Ansys 2019, the stress intensity factors that act at the crack tip of the adhesive interface were obtained. Mechanical simulation and microscopic investigation showed us how the interface of the dentine–adhesive–filling material performed in cases of both dental adhesives and for a certain loading condition. Important differences were identified among the adhesives, the fourth generation being superior to the fourth generation especially due to the separate steps in which the tooth surface was prepared for adhesion.
Open AccessComparative Study on Interface Fracture of 4th Generation 3-Steps Adhesive and 7th Generation Universal Adhesive
The purpose of this paper is to compare the fracture behavior of interfaces obtained using fourth-generation and universal dental adhesives. The study relies on optic and SEM to evaluate the dentin–adhesive–restoration material interface of the samples and also on FEA simulation of fracture behavior. Specimen fabrication relied on 20 extracted teeth, in which class I cavities were created according to a protocol established based on the rules of minimally invasive therapy. For the direct adhesive technique, the adhesives used were: three-step All Bond, three-batch A and one-step Clearfil Universal Bond Quick-batch B. The restoration was performed with the same composite for both adhesives: Gradia direct posterior. The simulation used a 3D reconstructed molar on which geometric operations were performed to obtain an assembly that replicated a physical specimen. Material properties were applied to each component based on the information found in the literature. A simplified model for crack propagation was constructed, and using the fracture mechanics tool in Ansys 2019, the stress intensity factors that act at the crack tip of the adhesive interface were obtained. Mechanical simulation and microscopic investigation showed us how the interface of the dentine–adhesive–filling material performed in cases of both dental adhesives and for a certain loading condition. Important differences were identified among the adhesives, the fourth generation being superior to the fourth generation especially due to the separate steps in which the tooth surface was prepared for adhesion.
- Open Access
Metal–Ceramic Compatibility in Dental Restorations According to the Metallic Component Manufacturing Procedure
In terms of production technology, metal–ceramic systems for dental restorations comply with a concrete algorithm, the efficiency of which is always dependent on the applications for which they are intended. The first stage involves obtaining metal support, followed by firing the ceramic on the surface of the metal to meet the list of functional and aesthetic requirements of a future restoration. The compatibility of the two materials—the metal component and the ceramic component—must be ensured in several respects: chemical compatibility, thermo–chemical compatibility, and mechanical compatibility. Thus, there is a need to simulate the thermal behavior of the metal–ceramic couple in its processing to achieve appropriate dental prostheses. In this study, three types of Co–Cr metal frames were manufactured using three different production technologies: conventional casting, milling (CAM), and selective laser melting (SLM). Composition analyses, scanning electron microscopy (SEM), and microstructural analyses of the metal–ceramic interface for each type of production technology, as well as the determination of the hardness and the thermal expansion coefficients of experimental materials and three-point bending tests, were carried out in this study. Considering all these aspects, we demonstrated the influence of the technology of producing the metallic part of the metal–ceramic bonding process in dental prostheses.
Open AccessMetal–Ceramic Compatibility in Dental Restorations According to the Metallic Component Manufacturing Procedure
In terms of production technology, metal–ceramic systems for dental restorations comply with a concrete algorithm, the efficiency of which is always dependent on the applications for which they are intended. The first stage involves obtaining metal support, followed by firing the ceramic on the surface of the metal to meet the list of functional and aesthetic requirements of a future restoration. The compatibility of the two materials—the metal component and the ceramic component—must be ensured in several respects: chemical compatibility, thermo–chemical compatibility, and mechanical compatibility. Thus, there is a need to simulate the thermal behavior of the metal–ceramic couple in its processing to achieve appropriate dental prostheses. In this study, three types of Co–Cr metal frames were manufactured using three different production technologies: conventional casting, milling (CAM), and selective laser melting (SLM). Composition analyses, scanning electron microscopy (SEM), and microstructural analyses of the metal–ceramic interface for each type of production technology, as well as the determination of the hardness and the thermal expansion coefficients of experimental materials and three-point bending tests, were carried out in this study. Considering all these aspects, we demonstrated the influence of the technology of producing the metallic part of the metal–ceramic bonding process in dental prostheses.
- Open Access
Microstructure and Corrosion Behaviour of Mg-Ca and Mg-Zn-Ag Alloys for Biodegradable Hard Tissue Implants
Trauma orthopaedic surgery was the first domain to use degradable metallic implants made of magnesium alloys since the early 20th century. Unfortunately, the major limitation that consists of rapid degradation and subsequent implant failure, which occur in physiological environments with a pH between 7.4 and 7.6, prevents its widespread application. The biggest challenge in corrosion assay is the choice of the testing medium in order to reproduce more closely in vivo conditions. The current study was focused on two Mg-Zn-Ag alloys (Mg7Zn1Ag and Mg6Zn3Ag) and the Mg1Ca alloy. Dulbecco’s Modified Eagle Medium (DMEM) and Kokubo’s simulated body fluid solution (SBF) were selected as testing mediums and we follow the corrosion evaluation by the corrosion rate and mass loss. Also, the corrosion behaviour was interpreted in correlation with the microstructural features and alloying elements of the experimental magnesium-based alloys revealed by optical microscopy (OM), X-ray diffraction (XRD), and scanning electron microscopy (SEM) coupled with energy dispersive spectroscopy (EDX). The experimental results highlight the more corrosive nature of the SBF environment and that a higher percentage of silver (2.5 wt.%) exhibited a better corrosion resistance. We consider that the magnesium alloy Mg6Zn3Ag showed valuable biodegradation characteristics to be considered as raw materials for manufacturing small trauma implants.
Open AccessMicrostructure and Corrosion Behaviour of Mg-Ca and Mg-Zn-Ag Alloys for Biodegradable Hard Tissue Implants
Trauma orthopaedic surgery was the first domain to use degradable metallic implants made of magnesium alloys since the early 20th century. Unfortunately, the major limitation that consists of rapid degradation and subsequent implant failure, which occur in physiological environments with a pH between 7.4 and 7.6, prevents its widespread application. The biggest challenge in corrosion assay is the choice of the testing medium in order to reproduce more closely in vivo conditions. The current study was focused on two Mg-Zn-Ag alloys (Mg7Zn1Ag and Mg6Zn3Ag) and the Mg1Ca alloy. Dulbecco’s Modified Eagle Medium (DMEM) and Kokubo’s simulated body fluid solution (SBF) were selected as testing mediums and we follow the corrosion evaluation by the corrosion rate and mass loss. Also, the corrosion behaviour was interpreted in correlation with the microstructural features and alloying elements of the experimental magnesium-based alloys revealed by optical microscopy (OM), X-ray diffraction (XRD), and scanning electron microscopy (SEM) coupled with energy dispersive spectroscopy (EDX). The experimental results highlight the more corrosive nature of the SBF environment and that a higher percentage of silver (2.5 wt.%) exhibited a better corrosion resistance. We consider that the magnesium alloy Mg6Zn3Ag showed valuable biodegradation characteristics to be considered as raw materials for manufacturing small trauma implants.