Caroline A. Grant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Caroline A. Grant has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Maree Therese Izatt
School of Mechanical, Medical and Process Engineering Queensland University of Technology Brisbane Australia
4 shared publications - Mark John Pearcy
Paediatric Spine Research Group, Queensland University of Technology and Mater Health Services Brisbane Ltd, Queensland, Australia
4 shared publications - Geoffrey Noel Askin
School of Mechanical, Medical and Process Engineering Queensland University of Technology Brisbane Australia
3 shared publications - Judith Paige Little
School of Mechanical, Medical and Process Engineering Queensland University of Technology Brisbane Australia
3 shared publications - Nicolas Newell
Department of Bioengineering, Imperial College London, United Kingdom
3 shared publications - Clayton J. Adam
Queensland University of Technology
2 shared publications
Latest Publications
- 17 June 2020
- Published by Springer Nature in Spine Deformity
- Vol. 8 (6) , 1193-1204
Characterization of progressive changes in pedicle morphometry and neurovascular anatomy during growth in adolescent idiopathic scoliosis versus adolescents without scoliosis
Study design Prospective cohort study. Objectives Investigate the progressive changes in pedicle morphometry and the spatial relationship between the pedicles and neurovascular structures in patients with AIS during growth. Summary of background data Adolescent idiopathic scoliosis (AIS) is a complex three-dimensional spine deformity. AIS pedicles are known to be asymmetrical when compared to adolescents without scoliosis. Defining the anatomical changes occurring progressively in scoliosis as it increases with time and growth is essential for understanding the pathophysiology of scoliosis and for treatment planning. MRI is the ideal method to study the growing spine without ionising radiation. Methods 24 females with AIS (mean 12.6 years, right sided main thoracic curves) and 20 non-scoliotic females (mean 11.5 years) were selected from an ongoing database. Participants underwent two 3D MRI scans (3 T scanner, T1, 0.5 mm isotropic voxels) approximately 1 year apart (AIS: mean 1.3 ± 0.05 years, control: mean 1.0 ± 0.1 years). The pedicle width, chord length, pedicle height, transverse pedicle angle, sagittal pedicle angle, distance from vertebrae to aorta and distance from pedicle to dural sac were measured from T5 to T12. Inter- and intra-observer variability was assessed. Results From scans 1–2 in the AIS group, the dural sac became closer to the left pedicle (p < 0.05, T6, T8–T10 and T12) while the distance from the vertebrae to the aorta increased (p < 0.05, T6–T10). No significant changes in these measurements were observed in the non-scoliotic group. Between scans, the AIS chord length and transverse pedicle angle increased on the left side around the apex (p < 0.05) creating asymmetries not seen in the non-scoliotic cohort. The mean pedicle height increased symmetrically in the non-scoliosis cohort (p < 0.05) and asymmetrically in the AIS group with the right side growing faster than the left at T6–T7 (p < 0.05). Conclusion Asymmetrical growth patterns occur in the vertebral posterior elements of AIS patients compared to the symmetrical growth patterns found in the non-scoliotic participants. Level of evidence Level II prospective comparative study.
- 17 June 2020
- Published by Springer Nature in Spine Deformity
- Vol. 8 (6) , 1193-1204
Characterization of progressive changes in pedicle morphometry and neurovascular anatomy during growth in adolescent idiopathic scoliosis versus adolescents without scoliosis
Study design Prospective cohort study. Objectives Investigate the progressive changes in pedicle morphometry and the spatial relationship between the pedicles and neurovascular structures in patients with AIS during growth. Summary of background data Adolescent idiopathic scoliosis (AIS) is a complex three-dimensional spine deformity. AIS pedicles are known to be asymmetrical when compared to adolescents without scoliosis. Defining the anatomical changes occurring progressively in scoliosis as it increases with time and growth is essential for understanding the pathophysiology of scoliosis and for treatment planning. MRI is the ideal method to study the growing spine without ionising radiation. Methods 24 females with AIS (mean 12.6 years, right sided main thoracic curves) and 20 non-scoliotic females (mean 11.5 years) were selected from an ongoing database. Participants underwent two 3D MRI scans (3 T scanner, T1, 0.5 mm isotropic voxels) approximately 1 year apart (AIS: mean 1.3 ± 0.05 years, control: mean 1.0 ± 0.1 years). The pedicle width, chord length, pedicle height, transverse pedicle angle, sagittal pedicle angle, distance from vertebrae to aorta and distance from pedicle to dural sac were measured from T5 to T12. Inter- and intra-observer variability was assessed. Results From scans 1–2 in the AIS group, the dural sac became closer to the left pedicle (p < 0.05, T6, T8–T10 and T12) while the distance from the vertebrae to the aorta increased (p < 0.05, T6–T10). No significant changes in these measurements were observed in the non-scoliotic group. Between scans, the AIS chord length and transverse pedicle angle increased on the left side around the apex (p < 0.05) creating asymmetries not seen in the non-scoliotic cohort. The mean pedicle height increased symmetrically in the non-scoliosis cohort (p < 0.05) and asymmetrically in the AIS group with the right side growing faster than the left at T6–T7 (p < 0.05). Conclusion Asymmetrical growth patterns occur in the vertebral posterior elements of AIS patients compared to the symmetrical growth patterns found in the non-scoliotic participants. Level of evidence Level II prospective comparative study.
- 20 November 2018
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 63 (1) , 63-71
Accuracy of 3D surface scanners for clinical torso and spinal deformity assessment
Externally visible deformities are cosmetic features of great concern for Adolescent Idiopathic Scoliosis (AIS) patients. Current assessment techniques for AIS do not fully encompass the external deformity. A non-invasive method capable of capturing superficial anatomy, such as 3D scanning, would enable better qualitative and quantitative evaluation of cosmesis. This study aimed to quantify the accuracy of commonly available scanners, in assessing posterior asymmetry in AIS. The technique of 3D surface deviation analysis was proposed as a suitable method for comparing the models created by each scanner. Eight plaster cast moulds manufactured to create braces for AIS patients were used as test samples. Four 3D scanners were selected: Solutionix RexScan CS+; Artec Eva; Microsoft Kinect V1; iPhone with 123D Catch App. These scanners were selected from those available as representative of a range of scanning technologies. Each cast was scanned and 3D models created. A simulated rib hump measurement was obtained and the surface-to-surface deviations between the Solutionix scan and all other scans were determined. The Solutionix scanner is a metrology scanner of very high quality and so it was selected as the reference. Surface-to-surface deviations were calculated in the positive and negative directions separately to specifically identify size and volume inaccuracies created by the scans. Surface deviations showed excellent agreement between the Solutionix and the Eva with deviations of +0.17 ± 0.17 mm (Eva regions larger) and -0.20 ± 0.32 mm (Eva regions smaller) (mean±SD). The Kinect showed lower agreement (+1.58 ± 1.50 mm and -0.58 ± 0.58 mm). The iPhone scans were not able to be scaled to the correct size, so were excluded. Rib hump measurements with all scanners were within clinical measurement variability (±4.9 deg) of the known values. These commercially available 3D scanners are capable of imaging torso shape in 3D and deriving clinically relevant external deformity measures. The non-invasive 3D topographic information provided can be used to improve assessment of torso shape in spinal deformity patients.
- 20 November 2018
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 63 (1) , 63-71
Accuracy of 3D surface scanners for clinical torso and spinal deformity assessment
Externally visible deformities are cosmetic features of great concern for Adolescent Idiopathic Scoliosis (AIS) patients. Current assessment techniques for AIS do not fully encompass the external deformity. A non-invasive method capable of capturing superficial anatomy, such as 3D scanning, would enable better qualitative and quantitative evaluation of cosmesis. This study aimed to quantify the accuracy of commonly available scanners, in assessing posterior asymmetry in AIS. The technique of 3D surface deviation analysis was proposed as a suitable method for comparing the models created by each scanner. Eight plaster cast moulds manufactured to create braces for AIS patients were used as test samples. Four 3D scanners were selected: Solutionix RexScan CS+; Artec Eva; Microsoft Kinect V1; iPhone with 123D Catch App. These scanners were selected from those available as representative of a range of scanning technologies. Each cast was scanned and 3D models created. A simulated rib hump measurement was obtained and the surface-to-surface deviations between the Solutionix scan and all other scans were determined. The Solutionix scanner is a metrology scanner of very high quality and so it was selected as the reference. Surface-to-surface deviations were calculated in the positive and negative directions separately to specifically identify size and volume inaccuracies created by the scans. Surface deviations showed excellent agreement between the Solutionix and the Eva with deviations of +0.17 ± 0.17 mm (Eva regions larger) and -0.20 ± 0.32 mm (Eva regions smaller) (mean±SD). The Kinect showed lower agreement (+1.58 ± 1.50 mm and -0.58 ± 0.58 mm). The iPhone scans were not able to be scaled to the correct size, so were excluded. Rib hump measurements with all scanners were within clinical measurement variability (±4.9 deg) of the known values. These commercially available 3D scanners are capable of imaging torso shape in 3D and deriving clinically relevant external deformity measures. The non-invasive 3D topographic information provided can be used to improve assessment of torso shape in spinal deformity patients.
- 15 April 2017
- Published by Wolters Kluwer Health in Spine
- Vol. 42 (8) , E459-E465
Role of the Middle Lumbar Fascia on Spinal Mechanics
Biomechanical experiment. The aims of the present study were to test the effect of fascial tension on lumbar segmental axial rotation and lateral flexion and the effect of the angle of fascial attachment. Tension in the middle layer of lumbar fascia has been demonstrated to affect mechanical properties of lumbar segmental flexion and extension in the neutral zone. The effect of tension on segmental axial rotation and lateral flexion has, however, not been investigated. Seven unembalmed lumbar spines were divided into segments and mounted for testing. A 6 degree-of-freedom robotic testing facility was used to displace the segments in each anatomical plane (flexion-extension, lateral bending, and axial rotation) with force and moment data recorded by a load cell positioned beneath the test specimen. Tests were performed with and without a 20 N fascia load and the subsequent forces and moments were compared. In addition, forces and moments were compared when the specimens were held in a set position and the fascia loading angle was varied. A fascial tension of 20 N had no measurable effect on the forces or moments measured when the specimens were displaced in any plane of motion (P > 0.05). When 20 N of fascial load were applied to motion segments in a set position small segmental forces and moments were measured. Changing the angle of the fascial load did not significantly alter these measurements. Application of a 20 N fascial load did not produce a measureable effect on the mechanics of a motion segment, even though it did produce small measurable forces and moments on the segments when in a fixed position. Results from the present study are inconsistent with previous studies, suggesting that further investigation using multiple testing protocols and different loading conditions is required to determine the effects of fascial loading on spinal segment behavior. Level of Evidence: N/A
- 15 April 2017
- Published by Wolters Kluwer Health in Spine
- Vol. 42 (8) , E459-E465
Role of the Middle Lumbar Fascia on Spinal Mechanics
Biomechanical experiment. The aims of the present study were to test the effect of fascial tension on lumbar segmental axial rotation and lateral flexion and the effect of the angle of fascial attachment. Tension in the middle layer of lumbar fascia has been demonstrated to affect mechanical properties of lumbar segmental flexion and extension in the neutral zone. The effect of tension on segmental axial rotation and lateral flexion has, however, not been investigated. Seven unembalmed lumbar spines were divided into segments and mounted for testing. A 6 degree-of-freedom robotic testing facility was used to displace the segments in each anatomical plane (flexion-extension, lateral bending, and axial rotation) with force and moment data recorded by a load cell positioned beneath the test specimen. Tests were performed with and without a 20 N fascia load and the subsequent forces and moments were compared. In addition, forces and moments were compared when the specimens were held in a set position and the fascia loading angle was varied. A fascial tension of 20 N had no measurable effect on the forces or moments measured when the specimens were displaced in any plane of motion (P > 0.05). When 20 N of fascial load were applied to motion segments in a set position small segmental forces and moments were measured. Changing the angle of the fascial load did not significantly alter these measurements. Application of a 20 N fascial load did not produce a measureable effect on the mechanics of a motion segment, even though it did produce small measurable forces and moments on the segments when in a fixed position. Results from the present study are inconsistent with previous studies, suggesting that further investigation using multiple testing protocols and different loading conditions is required to determine the effects of fascial loading on spinal segment behavior. Level of Evidence: N/A
- 1 September 2016
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 31 (3) , 172-180
Use of 3D Printing in Complex Spinal Surgery: Historical Perspectives, Current Usage, and Future Directions
Three-dimensional (3D) printing has been used in complex spinal surgical planning since the 1990s and is now increasingly utilized to produce surgical guides, templates, and more recently customized implants. Surgeons report beneficial impacts using 3D-printed biomodels as a preoperative planning aid as it generally provides for a better representation of the patient’s anatomy than on-screen viewing of computed tomography or magnetic resonance imaging. Furthermore, it has proven to be very beneficial in surgical training, and in explaining complex deformity and surgical plans to patients/parents. This paper reviews the historical perspective, current use, and future directions in using 3D printing in complex spinal surgery cases. This review reflects the authors’ opinion of where the field is moving in light of the current literature. Despite the reported benefits of 3D printing for surgical planning in the recent years, it remains a highly niche market. This review raises the question as to why the use of this technology has not progressed more rapidly despite the reported advantages—decreased operating time, decreased radiation exposure to patients intraoperatively, improved overall surgical outcomes, preoperative implant selection, as well as being an excellent communication aid for all medical and surgical team members. Increasingly, the greatest benefits of 3D-printing technology in spinal surgery are custom designed drill guides, templates for pedicle screw placement, and customized patient-specific implants. With applications such as these, 3D-printing technology could potentially revolutionize health care in the near future.
- 1 September 2016
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 31 (3) , 172-180
Use of 3D Printing in Complex Spinal Surgery: Historical Perspectives, Current Usage, and Future Directions
Three-dimensional (3D) printing has been used in complex spinal surgical planning since the 1990s and is now increasingly utilized to produce surgical guides, templates, and more recently customized implants. Surgeons report beneficial impacts using 3D-printed biomodels as a preoperative planning aid as it generally provides for a better representation of the patient’s anatomy than on-screen viewing of computed tomography or magnetic resonance imaging. Furthermore, it has proven to be very beneficial in surgical training, and in explaining complex deformity and surgical plans to patients/parents. This paper reviews the historical perspective, current use, and future directions in using 3D printing in complex spinal surgery cases. This review reflects the authors’ opinion of where the field is moving in light of the current literature. Despite the reported benefits of 3D printing for surgical planning in the recent years, it remains a highly niche market. This review raises the question as to why the use of this technology has not progressed more rapidly despite the reported advantages—decreased operating time, decreased radiation exposure to patients intraoperatively, improved overall surgical outcomes, preoperative implant selection, as well as being an excellent communication aid for all medical and surgical team members. Increasingly, the greatest benefits of 3D-printing technology in spinal surgery are custom designed drill guides, templates for pedicle screw placement, and customized patient-specific implants. With applications such as these, 3D-printing technology could potentially revolutionize health care in the near future.
- 6 June 2016
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 39 (3) , 281-291
A comparison of vertebral venous networks in adolescent idiopathic scoliosis patients and healthy controls
Cadaveric studies have previously documented a typical pattern of venous drainage within vertebral bodies (VBs), comprised primarily of the basivertebral vein. These studies, however, are limited by the number of samples available. MRI is able to provide 3D images of soft tissue structures in the spine, including the basivertebral vein without the use of contrast in both healthy controls and subjects with abnormal anatomy such as adolescent idiopathic scoliosis (AIS). This study aimed to quantify the venous networks within VBs of 15 healthy adolescent controls and 15 AIS patients. Five transverse slices through the VBs were examined simultaneously and the observable vascular network traced. The length of the network on the left and right sides of the VB was calculated, and the spatial patterning assessed level-by-level within each subject. Significant differences were seen in the left/right distribution of vessels in both the control and AIS subjects, with both groups having greater length on the right side of all of their VBs. No difference was seen between AIS and control subjects in any region. Large individual variations in patterns were seen in both groups; however, the control group showed more consistent spatial patterning of the vascular networks across levels in comparison to the AIS group. The length of the basivertebral vein was seen to have a significant bias to the right hand side of the VB in both healthy and AIS adolescents. The spatial pattern of this vein showed large variations in branching both within and across individuals. No significant differences were seen between AIS and control subjects, suggesting both that this network is preserved in deformed AIS vertebrae, and that the vertebral venous system does not play a role in the etiology of AIS.
- 6 June 2016
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 39 (3) , 281-291
A comparison of vertebral venous networks in adolescent idiopathic scoliosis patients and healthy controls
Cadaveric studies have previously documented a typical pattern of venous drainage within vertebral bodies (VBs), comprised primarily of the basivertebral vein. These studies, however, are limited by the number of samples available. MRI is able to provide 3D images of soft tissue structures in the spine, including the basivertebral vein without the use of contrast in both healthy controls and subjects with abnormal anatomy such as adolescent idiopathic scoliosis (AIS). This study aimed to quantify the venous networks within VBs of 15 healthy adolescent controls and 15 AIS patients. Five transverse slices through the VBs were examined simultaneously and the observable vascular network traced. The length of the network on the left and right sides of the VB was calculated, and the spatial patterning assessed level-by-level within each subject. Significant differences were seen in the left/right distribution of vessels in both the control and AIS subjects, with both groups having greater length on the right side of all of their VBs. No difference was seen between AIS and control subjects in any region. Large individual variations in patterns were seen in both groups; however, the control group showed more consistent spatial patterning of the vascular networks across levels in comparison to the AIS group. The length of the basivertebral vein was seen to have a significant bias to the right hand side of the VB in both healthy and AIS adolescents. The spatial pattern of this vein showed large variations in branching both within and across individuals. No significant differences were seen between AIS and control subjects, suggesting both that this network is preserved in deformed AIS vertebrae, and that the vertebral venous system does not play a role in the etiology of AIS.
- 1 July 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (7) , 1665-1673
A semiautomatic method to identify vertebral end plate lesions (Schmorl's nodes)
- 1 July 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (7) , 1665-1673
A semiautomatic method to identify vertebral end plate lesions (Schmorl's nodes)
- 1 May 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (7) , 869-874
Comparison of mechanical and ultrasound elastic modulus of ovine tibial cortical bone
Finite element models of bones can be created by deriving geometry from an X-ray CT scan. Material properties such as the elastic modulus can then be applied using either a single or set of homogeneous values, or individual elements can have local values mapped onto them. Values for the elastic modulus can be derived from the CT density values using an elasticity versus density relationship. Many elasticity-density relationships have been reported in the literature for human bone. However, while ovine in vivo models are common in orthopaedic research, no work has been done to date on creating FE models of ovine bones. To create these models and apply relevant material properties, an ovine elasticity-density relationship needs to be determined. Using fresh frozen ovine tibias the apparent density of regions of interest was determined from a clinical CT scan. The bones were the sectioned into cuboid samples of cortical bone from the regions of interest. Ultrasound was used to determine the elastic modulus in each of three directions - longitudinally, radially and tangentially. Samples then underwent traditional compression testing in each direction. The relationships between apparent density and both ultrasound, and compression modulus in each direction were determined. Ultrasound testing was found to be a highly repeatable non-destructive method of calculating the elastic modulus, particularly suited to samples of this size. The elasticity-density relationships determined in the longitudinal direction were very similar between the compression and ultrasound data over the density range examined. A clear difference was seen in the elastic modulus between the longitudinal and transverse directions of the bone samples, and a transverse elasticity-density relationship is also reported.
- 1 May 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (7) , 869-874
Comparison of mechanical and ultrasound elastic modulus of ovine tibial cortical bone
Finite element models of bones can be created by deriving geometry from an X-ray CT scan. Material properties such as the elastic modulus can then be applied using either a single or set of homogeneous values, or individual elements can have local values mapped onto them. Values for the elastic modulus can be derived from the CT density values using an elasticity versus density relationship. Many elasticity-density relationships have been reported in the literature for human bone. However, while ovine in vivo models are common in orthopaedic research, no work has been done to date on creating FE models of ovine bones. To create these models and apply relevant material properties, an ovine elasticity-density relationship needs to be determined. Using fresh frozen ovine tibias the apparent density of regions of interest was determined from a clinical CT scan. The bones were the sectioned into cuboid samples of cortical bone from the regions of interest. Ultrasound was used to determine the elastic modulus in each of three directions - longitudinally, radially and tangentially. Samples then underwent traditional compression testing in each direction. The relationships between apparent density and both ultrasound, and compression modulus in each direction were determined. Ultrasound testing was found to be a highly repeatable non-destructive method of calculating the elastic modulus, particularly suited to samples of this size. The elasticity-density relationships determined in the longitudinal direction were very similar between the compression and ultrasound data over the density range examined. A clear difference was seen in the elastic modulus between the longitudinal and transverse directions of the bone samples, and a transverse elasticity-density relationship is also reported.