Alison C. Dunn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alison C. Dunn has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- W. Gregory Sawyer
Moffitt Cancer Center
8 shared publications Shabnam Z. Bonyadi
Department of Mechanical Science & Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
5 shared publicationsThomas E. Angelini
Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville FL, USA
5 shared publicationsJiho Kim
Department of Mechanical Science & Engineering, Grainger College of Engineering, University of Illinois at Urbana-Champaign, Urbana, USA
4 shared publicationsJuan Manuel Urueña
Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville FL, USA
3 shared publicationsKyle D. Schulze
Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville FL, USA
3 shared publications
Latest Publications
- 1 July 2025
- Published by Springer Nature in Experimental Mechanics
- p. 1-9
Continuous Visualization of Time-Dependent Deformation of a Hydrogel Surface
- 1 July 2025
- Published by Springer Nature in Experimental Mechanics
- p. 1-9
Continuous Visualization of Time-Dependent Deformation of a Hydrogel Surface
- 21 October 2024
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 20 (44) , 8783-8792
Network interactions simultaneously enhance stiffness and lubricity of triple-network hydrogels
Synthetic hydrogels displaying cartilage-mimetic bulk and surface properties may serve as cartilage substitutes. Multi-network, electrostatic hydrogels that leverage intra- and inter-network repulsive and attractive forces represent a promising approach. Herein, triple network (TN) hydrogels were prepared to obtain a combination of desired characteristics (i.e., hydration, stiffness, shear stress, and friction properties). The TN hydrogels were comprised of a negatively charged 1st network and a neutral 2nd network possessing hydrophobic associations. Presumed to significantly influence surface properties, the 3rd network charge was systematically varied as cationic, anionic, and zwitterionic. A double-network (DN) hydrogel, comprised of the same 1st and 2nd network as for the TN hydrogels, was included as a control as well as native cartilage specimens. Micro-indentation was performed with a steel ball, yielding stiffness values as well as the contact area during sliding. The lubrication in both deionized (DI) water and fetal bovine serum (FBS) was evaluated with the micro-indenter wherein the stage reciprocated in a range of speeds. All the TN hydrogels exhibited greater Youngs modulus than the DN hydrogel control. The TN bearing a cationic 3rd network exhibited an exceptionally high Youngs modulus of ≈1.4 MPa, which was even higher than that of the cartilage samples. In both DI water and FBS, for most testing speeds, the TN hydrogels exhibited lower friction coefficient (COF) values and lower shear stresses than DN hydrogel as well as the native cartilage specimens.
- 21 October 2024
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 20 (44) , 8783-8792
Network interactions simultaneously enhance stiffness and lubricity of triple-network hydrogels
Synthetic hydrogels displaying cartilage-mimetic bulk and surface properties may serve as cartilage substitutes. Multi-network, electrostatic hydrogels that leverage intra- and inter-network repulsive and attractive forces represent a promising approach. Herein, triple network (TN) hydrogels were prepared to obtain a combination of desired characteristics (i.e., hydration, stiffness, shear stress, and friction properties). The TN hydrogels were comprised of a negatively charged 1st network and a neutral 2nd network possessing hydrophobic associations. Presumed to significantly influence surface properties, the 3rd network charge was systematically varied as cationic, anionic, and zwitterionic. A double-network (DN) hydrogel, comprised of the same 1st and 2nd network as for the TN hydrogels, was included as a control as well as native cartilage specimens. Micro-indentation was performed with a steel ball, yielding stiffness values as well as the contact area during sliding. The lubrication in both deionized (DI) water and fetal bovine serum (FBS) was evaluated with the micro-indenter wherein the stage reciprocated in a range of speeds. All the TN hydrogels exhibited greater Youngs modulus than the DN hydrogel control. The TN bearing a cationic 3rd network exhibited an exceptionally high Youngs modulus of ≈1.4 MPa, which was even higher than that of the cartilage samples. In both DI water and FBS, for most testing speeds, the TN hydrogels exhibited lower friction coefficient (COF) values and lower shear stresses than DN hydrogel as well as the native cartilage specimens.
- 20 September 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 40 (39) , 20406-20415
Adhesion Mechanics and Detachment Dynamics of Vanishing Surface Layers on Hydrogels
Cross-linked hydrogel surfaces exhibit reduced stiffness when polymerized against polymeric hydrophobic surfaces. As such, these layers play a critical role in contact mechanics, particularly exhibiting strong relative adhesion with colloidal probes when the contact area is small. This prevents the use of continuum models of adhesive soft contact. To connect mechanisms of stretch to the force response, depth-controlled nanoindentation experiments were conducted on polyacrylamide (pAAM) hydrogel samples using colloidal probe atomic force microscopy (AFM). The pAAM sample had a high water content of >90% and was molded against polyoxymethylene (POM) to create a more dilute surface layer with thickness ∼0.5 μm. Indentations to multiple depths between 50 nm and 1.25 μm were repeated 10 times each. First, the force drops during the unloading, and separation segments of each indentation were characterized. This described the detachment progression for increasing areas of contact, revealing that the pull-off force for a single chain was in the single-pN range. Second, the stretched polymer network was modeled as an array of parallel, linear springs. Assuming a constant areal chain density of α = 100 chains/μm2, the maximum force of adhesion was plotted versus the volume of chains stretched upward, and the average chain stiffness was calculated from a linear fit to be 22.8 × 10-6 N/m. A Weibull distribution analysis of detachment events revealed a dependence of chain stiffness on maximum indentation depth (dmax), with higher stiffness at shallower depths approaching kchain ≈ 20 × 10-6 N/m. These findings on adhesion mechanics between a vanishing hydrogel surface and probe can guide the development of multifunctional hydrogels for various biomedical applications.
- 20 September 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 40 (39) , 20406-20415
Adhesion Mechanics and Detachment Dynamics of Vanishing Surface Layers on Hydrogels
Cross-linked hydrogel surfaces exhibit reduced stiffness when polymerized against polymeric hydrophobic surfaces. As such, these layers play a critical role in contact mechanics, particularly exhibiting strong relative adhesion with colloidal probes when the contact area is small. This prevents the use of continuum models of adhesive soft contact. To connect mechanisms of stretch to the force response, depth-controlled nanoindentation experiments were conducted on polyacrylamide (pAAM) hydrogel samples using colloidal probe atomic force microscopy (AFM). The pAAM sample had a high water content of >90% and was molded against polyoxymethylene (POM) to create a more dilute surface layer with thickness ∼0.5 μm. Indentations to multiple depths between 50 nm and 1.25 μm were repeated 10 times each. First, the force drops during the unloading, and separation segments of each indentation were characterized. This described the detachment progression for increasing areas of contact, revealing that the pull-off force for a single chain was in the single-pN range. Second, the stretched polymer network was modeled as an array of parallel, linear springs. Assuming a constant areal chain density of α = 100 chains/μm2, the maximum force of adhesion was plotted versus the volume of chains stretched upward, and the average chain stiffness was calculated from a linear fit to be 22.8 × 10-6 N/m. A Weibull distribution analysis of detachment events revealed a dependence of chain stiffness on maximum indentation depth (dmax), with higher stiffness at shallower depths approaching kchain ≈ 20 × 10-6 N/m. These findings on adhesion mechanics between a vanishing hydrogel surface and probe can guide the development of multifunctional hydrogels for various biomedical applications.
- Open Access
- 10 November 2023
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 159 (18)
Fewer polymer chains but higher adhesion: How gradient-stiffness hydrogel layers mediate adhesion through network stretch
The presence of gradient softer outer layers, commonly observed in biological systems (such as cartilage and ocular tissues), as well as synthetic crosslinked hydrogels, profoundly influences their interactions with opposing surfaces. Our prior research demonstrated that gradient-stiffness hydrogel layers, characterized by increasing elasticity with depth, control contact mechanics, particularly in proximity to the layer thickness. We postulate that the distribution of polymers within these gradient layers imparts extraordinary stretch and adhesion characteristics due to network adaptability and stress-induced reorganization. To investigate this phenomenon, we utilized Atomic Force Microscopy nanoindentation to assess the depth-dependent adhesion behavior of polyacrylamide hydrogels with varying gradient layer thicknesses. Two gradient layer thicknesses were achieved by employing different molding materials: glass and polyoxymethylene (POM). Glass-molded hydrogels exhibited a thinner gradient layer alongside a stiffer bulk layer compared to their POM-molded counterparts. In indentation experiments, the POM-molded hydrogel had larger adhesion compared to glass-molded hydrogel. We find that indenting within the gradient layer engenders increased load-unload hysteresis due to heightened fluid transport in the sparse outer polymer network. Consequently, this led to augmented adhesion and work of separation at shallow depths. We suggest that the prominent stretching capability of the sparse outer polymer network during probe retraction contributes to enhanced adhesion. The Maugis–Dugdale adhesive model only fits well to indentations on the thin layer or indentations which engage significantly with the bulk. These results facilitate a comprehensive characterization of adhesion mechanics in gradient-stiffness hydrogels, which could foster their application across emerging contexts in health science and environmental domains.
- 10 November 2023
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 159 (18)
Open AccessFewer polymer chains but higher adhesion: How gradient-stiffness hydrogel layers mediate adhesion through network stretch
The presence of gradient softer outer layers, commonly observed in biological systems (such as cartilage and ocular tissues), as well as synthetic crosslinked hydrogels, profoundly influences their interactions with opposing surfaces. Our prior research demonstrated that gradient-stiffness hydrogel layers, characterized by increasing elasticity with depth, control contact mechanics, particularly in proximity to the layer thickness. We postulate that the distribution of polymers within these gradient layers imparts extraordinary stretch and adhesion characteristics due to network adaptability and stress-induced reorganization. To investigate this phenomenon, we utilized Atomic Force Microscopy nanoindentation to assess the depth-dependent adhesion behavior of polyacrylamide hydrogels with varying gradient layer thicknesses. Two gradient layer thicknesses were achieved by employing different molding materials: glass and polyoxymethylene (POM). Glass-molded hydrogels exhibited a thinner gradient layer alongside a stiffer bulk layer compared to their POM-molded counterparts. In indentation experiments, the POM-molded hydrogel had larger adhesion compared to glass-molded hydrogel. We find that indenting within the gradient layer engenders increased load-unload hysteresis due to heightened fluid transport in the sparse outer polymer network. Consequently, this led to augmented adhesion and work of separation at shallow depths. We suggest that the prominent stretching capability of the sparse outer polymer network during probe retraction contributes to enhanced adhesion. The Maugis–Dugdale adhesive model only fits well to indentations on the thin layer or indentations which engage significantly with the bulk. These results facilitate a comprehensive characterization of adhesion mechanics in gradient-stiffness hydrogels, which could foster their application across emerging contexts in health science and environmental domains.
- 1 November 2022
- Published by American Vacuum Society in Biointerphases
- Vol. 17 (6) , 061002
Composition controls soft hydrogel surface layer dimensions and contact mechanics
Hydrogels are soft hydrated polymer networks that are widely used in research and industry due to their favorable properties and similarity to biological tissues. However, it has long been difficult to create a hydrogel emulating the heterogeneous structure of special tissues, such as cartilage. One potential avenue to develop a structural variation in a hydrogel is the “mold effect,” which has only recently been discovered to be caused by absorbed oxygen within the mold surface interfering with the polymerization. This induces a dilute gradient-density surface layer with altered properties. However, the precise structure of the gradient-surface layer and its contact response have not yet been characterized. Such knowledge would prove useful for designs of composite hydrogels with altered surface characteristics. To fully characterize the hydrogel gradient-surface layer, we created five hydrogel compositions of varying monomer and cross-linker content to encompass variations in the layer. Then, we used particle exclusion microscopy during indentation and creep experiments to probe the contact response of the gradient layer of each composition. These experiments showed that the dilute structure of the gradient layer follows evolving contact behavior allowing poroelastic squeeze-out at miniscule pressures. Stiffer compositions had thinner gradient layers. This knowledge can potentially be used to create hydrogels with a stiff load-bearing bulk with altered surface characteristics tailored for specific tribological applications.
- 1 November 2022
- Published by American Vacuum Society in Biointerphases
- Vol. 17 (6) , 061002
Composition controls soft hydrogel surface layer dimensions and contact mechanics
Hydrogels are soft hydrated polymer networks that are widely used in research and industry due to their favorable properties and similarity to biological tissues. However, it has long been difficult to create a hydrogel emulating the heterogeneous structure of special tissues, such as cartilage. One potential avenue to develop a structural variation in a hydrogel is the “mold effect,” which has only recently been discovered to be caused by absorbed oxygen within the mold surface interfering with the polymerization. This induces a dilute gradient-density surface layer with altered properties. However, the precise structure of the gradient-surface layer and its contact response have not yet been characterized. Such knowledge would prove useful for designs of composite hydrogels with altered surface characteristics. To fully characterize the hydrogel gradient-surface layer, we created five hydrogel compositions of varying monomer and cross-linker content to encompass variations in the layer. Then, we used particle exclusion microscopy during indentation and creep experiments to probe the contact response of the gradient layer of each composition. These experiments showed that the dilute structure of the gradient layer follows evolving contact behavior allowing poroelastic squeeze-out at miniscule pressures. Stiffer compositions had thinner gradient layers. This knowledge can potentially be used to create hydrogels with a stiff load-bearing bulk with altered surface characteristics tailored for specific tribological applications.
- 27 July 2022
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 38 (31) , 9454-9465
Soft Contact Mechanics with Gradient-Stiffness Surfaces
The stiffness in the top surface of many biological entities like cornea or articular cartilage, as well as chemically cross-linked synthetic hydrogels, can be significantly lower or more compliant than the bulk. When such a heterogeneous surface comes into contact, the contacting load is distributed differently from typical contact models. The mechanical response under indentation loading of a surface with a gradient of stiffness is a complex, integrated response that necessarily includes the heterogeneity. In this work, we identify empirical contact models between a rigid indenter and gradient elastic surfaces by numerically simulating quasi-static indentation. Three key case studies revealed the specific ways in which (I) continuous gradients, (II) laminate-layer gradients, and (III) alternating gradients generate new contact mechanics at the shallow-depth limit. Validation of the simulation-generated models was done by micro- and nanoindentation experiments on polyacrylamide samples synthesized to have a softer gradient surface layer. The field of stress and stretch in the subsurface as visualized from the simulations also reveals that the gradient layers become confined, which pushes the stretch fields closer to the surface and radially outward. Thus, contact areas are larger than expected, and average contact pressures are lower than predicted by the Hertz model. The overall findings of this work are new contact models and the mechanisms by which they change. These models allow a more accurate interpretation of the plethora of indentation data on surface gradient soft matter (biological and synthetic) as well as a better prediction of the force response to gradient soft surfaces. This work provides examples of how gradient hydrogel surfaces control the subsurface stress distribution and loading response.
- 27 July 2022
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 38 (31) , 9454-9465
Soft Contact Mechanics with Gradient-Stiffness Surfaces
The stiffness in the top surface of many biological entities like cornea or articular cartilage, as well as chemically cross-linked synthetic hydrogels, can be significantly lower or more compliant than the bulk. When such a heterogeneous surface comes into contact, the contacting load is distributed differently from typical contact models. The mechanical response under indentation loading of a surface with a gradient of stiffness is a complex, integrated response that necessarily includes the heterogeneity. In this work, we identify empirical contact models between a rigid indenter and gradient elastic surfaces by numerically simulating quasi-static indentation. Three key case studies revealed the specific ways in which (I) continuous gradients, (II) laminate-layer gradients, and (III) alternating gradients generate new contact mechanics at the shallow-depth limit. Validation of the simulation-generated models was done by micro- and nanoindentation experiments on polyacrylamide samples synthesized to have a softer gradient surface layer. The field of stress and stretch in the subsurface as visualized from the simulations also reveals that the gradient layers become confined, which pushes the stretch fields closer to the surface and radially outward. Thus, contact areas are larger than expected, and average contact pressures are lower than predicted by the Hertz model. The overall findings of this work are new contact models and the mechanisms by which they change. These models allow a more accurate interpretation of the plethora of indentation data on surface gradient soft matter (biological and synthetic) as well as a better prediction of the force response to gradient soft surfaces. This work provides examples of how gradient hydrogel surfaces control the subsurface stress distribution and loading response.
- 5 November 2021
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 40 (4) , 1-18
Evaluating Rolling Contact Fatigue Damage Precursors with Rayleigh Waves in 1060 Steel
- 5 November 2021
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 40 (4) , 1-18
Evaluating Rolling Contact Fatigue Damage Precursors with Rayleigh Waves in 1060 Steel
- Open Access
- 21 October 2021
- Published by Springer Nature in Experimental Mechanics
- Vol. 61 (9) , 1503-1505
Special Issue on Tribology of Advanced Materials
- 21 October 2021
- Published by Springer Nature in Experimental Mechanics
- Vol. 61 (9) , 1503-1505
Open AccessSpecial Issue on Tribology of Advanced Materials
- 16 September 2021
- Published by Springer Nature in Tribology Letters
- Vol. 69 (4) , 1-15
Shakedown Analysis of Evolving Non-Hertzian Rolling Contact Using a Semi-analytical Numerical Model
- 16 September 2021
- Published by Springer Nature in Tribology Letters
- Vol. 69 (4) , 1-15
Shakedown Analysis of Evolving Non-Hertzian Rolling Contact Using a Semi-analytical Numerical Model
- 15 March 2021
- Published by Springer Nature in Experimental Mechanics
- Vol. 61 (5) , 829-842
Tribological Characterization of Gradient-density Polyacrylamide Hydrogel Surfaces
- 15 March 2021
- Published by Springer Nature in Experimental Mechanics
- Vol. 61 (5) , 829-842
Tribological Characterization of Gradient-density Polyacrylamide Hydrogel Surfaces