ACAlexander Connaughton

Alexander Connaughton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexander Connaughton has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Increasing Light Load Efficiency in Phase-Shifted, Variable Frequency Multiport Series Resonant Converters

    by Thomas Langbauer, Alexander Connaughton, Franz Vollmaier, Zhen Huang, Klaus Krischan, Roberto Petrella

    Multiport power conversion topologies provide the functionality of more single (and independent) converters but with just one transformer having multiple windings (i.e., ports). In automotive on-board chargers, the multiport approach combined with symmetrical series resonant circuits, the so-called multiport series resonant converter (MSRC), enable the required galvanic isolated connection from the grid-side converter (i.e., usually an AC-DC power factor correction (PFC) stage) to the vehicle’s batteries, i.e., the main high-voltage (HV) traction and the auxiliary low-voltage (LV), theoretically allowing to achieve increased power densities and enabling a flexible (and bidirectional) power routing among the different ports. High efficiency figures are normally specified in the considered application field for a very wide voltage ratios among the different ports, due to the variability of battery voltages, thus requiring proper and optimized control strategies of the underlying converter. The variation of the battery voltage is in fact highly affecting the MSRC operation, especially for light loads at a low state-of-charge, and high losses can be experienced since zero voltage switching conditions are lost. Beside the conventional control approach of the MSRC, where the power flow is set with a phase-shift between the individual full bridges or by changing the switching frequency, this paper proposes a novel and coordinated approach, including the manipulation of both and the additional modulation of the duty-cycle as a function of the grid-side DC-link voltage (i.e., the output of the PFC stage), aiming at introducing a zero-voltage interval on the full bridge output voltages. A full mathematical description of the adopted converter topology is reported, also including accurate simulation models for losses estimation allowing a fair comparison between the proposed duty-cycle mode control and the conventional control strategy. Detailed operation guideline for achieving zero-voltage switching within the connected full bridges is also reported. Experimental results validate the proposal and highlight a significant peak and average efficiency improvements with respect to standard control approaches.


  • A Preliminary Investigation into Approximating Power Transistor Switching Behavior using a Multilayer Perceptron

    by Jacob Reynvaan, Monika Stipsitz, Philipp Skoff, Thomas Langbauer, Alexander Connaughton

    This paper presents an approach for reproducing key characteristics of non-linear, high frequency switching transients using a multilayer perceptron neural network. Training data is generated using variable time-step transient simulations of a half-bridge switching cell of SPICE transistor models together with constrained yet randomized combinations of DC-link voltage, drain currents and lumped loop inductances. Using the example of peak turn-OFF voltage overshoot for SiC and Si power transistors, the multilayer perceptrons show a mean error of less than (0.9 ± 1.3)%. The predictions of the multilayer perceptron are then compared to preliminary measurements made using a SiC half-bridge test-bench where good agreement is observed especially for higher drain currents. With continued development, such a neural network could be used in coarse, fixed-time-step simulations of any “half-bridge-based” circuit to offer typically unavailable high-fidelity information with negligible computation time. For example, a designer could choose a transistor and quickly see the limits on allowable loop inductance to avoid excessive voltage overshoot for their simulated current waveforms, or see an estimate for voltage overshoot if the loop inductances are known.


  • Observation Versus Debridement of Unstable Chondral Lesions During Partial Meniscectomy

    by Leslie J. Bisson, Melissa A. Kluczynski, William M. Wind, Marc S. Fineberg, Geoffery A. Bernas, Michael A. Rauh, John M. Marzo, Brian Scrivens, Alexander Connaughton, Zehua Zhou, et al.

    Background: The purpose of this study was to examine the effect of debridement (CL-Deb) versus observation (CL-noDeb) of unstable chondral lesions on knee pain 5 years after arthroscopic partial meniscectomy (APM) in patients enrolled in the Chondral Lesions And Meniscus Procedures (ChAMP) Trial. Secondarily, other knee symptoms, function, general health, and the rate of additional surgery on the affected knee were examined. Methods: Patients aged ≥30 years who had an unstable Outerbridge grade-II, III, or IV chondral lesion when undergoing APM were randomly allocated to the CL-Deb (n = 98) or CL-noDeb (n = 92) group; ∼80% in each group completed a 5-year follow-up. Outcomes were measured preoperatively and at 5 years postoperatively, and included the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee injury and Osteoarthritis Outcome Score (KOOS), visual analog scale (VAS) for pain, Short Form-36 (SF-36), physical knee measurements, knee radiographs, and rate of additional knee surgery at 5 years. The primary outcome was the 5-year WOMAC pain score. Group comparisons were made using the t test for continuous outcomes and the Fisher exact test for categorical outcomes. Results: There were no significant differences between the groups with respect to the primary outcome, the WOMAC pain score (CL-Deb: 86.0 [95% confidence interval (CI): 82.9 to 89.1]) versus CL-noDeb: 88.3 [95% CI: 85.5 to 91.1]; p = 0.27), or secondary outcomes at 5 years. There were also no differences in radiographic measurements of joint-space narrowing in any compartment (medial or lateral tibiofemoral or medial, central, or lateral patellofemoral) as well as no difference in the rate of additional knee surgery within 5 years after APM between the CL-Deb and CL-noDeb groups. Conclusions: Outcomes for the CL-Deb and CL-noDeb groups did not differ at 5 years postoperatively, suggesting that there is no long-term benefit of arthroscopic debridement of chondral lesions encountered during APM. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


  • Variable on-Time Control Scheme for the Secondary-Side Controlled Flyback Converter

    by Alexander Michael Connaughton, Arash Pake Talei, Kennith Kin Leong, Klaus Krischan, Annette Muetze

    This paper presents an analysis of a novel control approach for the Secondary Side Controlled Flyback concept, along with improved drain-source voltage sensing for more precise gate signals and reduced losses. In contrast to the existing control scheme for this concept, the approach presented here sustains constant switching frequency throughout the load range without any additional hardware; boosting efficiency and simplifying couple inductor design optimization. A 65W demonstrator shows minimal output ripple during load changes, peak efficiency of 89.90%, natural output current limiting in overload conditions, and utilizes a novel lossless synchronous-rectification sensing sub-circuit with minimal zero current crossing delay.