MBMadalina-Petruta Bucur

Madalina-Petruta Bucur

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Madalina-Petruta Bucur has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cavitation-Effect-Based Treatments and Extractions for Superior Fruit and Milk Valorisation

    by Madalina-Petruta Bucur, Maria-Cristina Radulescu, Gabriel Lucian Radu, Bogdan Bucur

    Ultrasound generates cavities in liquids with high-energy behaviour due to large pressure variations, leading to (bio)chemical effects and material modification. Numerous cavity-based treatments in food processes have been reported, but the transition from research to industrial applications is hampered by specific engineering factors, such as the combination of several ultrasound sources, more powerful wave generators or tank geometry. The challenges and development of cavity-based treatments developed for the food industry are reviewed with examples limited to two representative raw materials (fruit and milk) with significantly different properties. Both active compound extraction and food processing techniques based on ultrasound are taken into consideration.


  • Electrochemical Detection Of Heavy Metals In Raw Materials Using a Glassy Carbon Electrode Modified With 4-Aminothiophenol

    by Maria-Cristina Radulescu, Madalina-Petruta Bucur, Bogdan Bucur, Gabriel Lucian Radu

    Sensitive and stable electrodes modified with 4-aminothiophenol were developed for heavy metal detection based on coordination bonds between thiol moieties and analyte. The electrodes were modified using diazonium chemistry in one step modification protocol. The presence of 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) in the electrodeposition media avoids the formation of multilayers and improves the performances due to low surface passivation and good electrochemical transfer at the interface with the solution. Electrodeposition of the organic layer on the electrode surface by chronopotentiometry allowed a good control of the electrode modification process, avoids passivation, and leads to reproducible layers with improved characteristics in comparison with modifications carried out by cyclic voltammetry or chronoamperometry. The electrode was able to detect Pb(II) by differential pulse voltammetry with a linear range of 2.5–400 μ g l −1 and the detection limit of 1.2 μ g l −1 and Cd(II) with the calibration line in the range of 2.5–400 μ g l −1 and a detection limit of 1.5 μ g l −1 . Low interferences were observed and the electrodes were applied for analysis of real samples: fruits pomace and waters.


  • Open Access

    Simple, selective and fast detection of acrylamide based on glutathione S-transferase

    by Madalina-Petruta Bucur, Bogdan Bucur, Gabriel-Lucian Radu

    Acrylamide (AA) is a toxic compound formed in thermally prepared foods by Maillard reaction. Besides foods, AA may be found in cosmetic products as an impurity of the widely-used non-toxic polyacrylamide. We present a novel, fast and selective detection method based on the amperometric monitoring of the coupling reaction between reduced glutathione (GSH) and AA catalyzed by glutathione S-transferase (GST) to produce an electrochemically inactive compound. We have used electrodes modified with cobalt-phthalocyanine to monitor the decrease of GHS concentration at +300 mV. Our system is simple, does not require supplementary substrates such as 1-chloro-2,4-dinitrobenzene (CDNB) nor have disadvantageous competitive kinetics characteristic to inhibition like signals. Using the optimum concentration of 100 μM GSH we have obtained a linear calibration graph from 7 to 50 μM AA and a limit of detection of 5 μM AA. The method is not affected by interfering compounds usually found in foods and was applied for real sample analysis.


  • Open Access

    Synthesis and retention properties of molecularly imprinted polymers for antibiotics containing a 5-nitrofuran ring

    by Edina Rusen, Aurel Diacon, Alexandra Mocanu, Florica Rizea, Bogdan Bucur, Madalina Petruta Bucur, Gabriel-Lucian Radu, Elena Bacalum, Mihaela Cheregi, Victor David

    Impedimetric sensor based on molecularly imprinted polymers synthetized for antibiotics containing a 5-nitrofuran ring.


  • Experimental characterization of a high accuracy amperometric sense and control circuit for three-electrode biosensors

    by Andrei Enache, Ion Rusu, Bogdan Bucur, Florin Draghici, Gheorghe Pristavu, Madalina-Petruta Bucur, Florin Enache, Gheorghe Brezeanu

    A Sense and Control Circuit (SCC) developed for amperometric concentration evaluation is redesigned, based on preliminary experimental investigations. This cost-effective circuit comprises a potentiostat for three-electrode electrochemical cell (biosensor) control and a transimpedance amplifier for cell current sensing. Stability, noise robustness and response time are improved, as demonstrated by experiments and simulations. SCC performances are evaluated in comparison with a professional system, by H2O2 concentration measurements.


  • Electrochemical Determination of Hydrogen Peroxide Using a Prussian Blue-Copper Modified Platinum Microelectrode

    by Maria-Cristina Radulescu, Madalina-Petruta Bucur, Andreia Alecu, Bogdan Bucur, Gabriel Lucian Radu

    Prussian blue modified with copper was electrodeposited on a platinum microelectrode for the amperometric determination of hydrogen peroxide at −50 mV. The Prussian blue-copper layer was stable for 2 h at pH 7.4 and a storage period of 2 months. The Prussian blue-copper modified microelectrodes were used to develop oxidase based microbiosensors for ethanol and lactate. Lactate and alcohol oxidases were immobilized by cross-linking with glutaraldehyde. No interferences were observed from possible interfering compounds up to a concentration of 0.5 mM. The calibration plot of the lactate microbiosensor was linear between 0.005 and 0.2 mM with a limit of detection of 0.0035 mM lactate. The linear dynamic range of the alcohol microbiosensor was between 0.05 and 2 mM and the limit of detection was 0.02 mM ethanol. The developed microbiosensors were used for the analysis of pickled cucumber juice, yogurt, and wine.


  • Low-interferences Determination of the Antioxidant Capacity in Fruits Juices Based on Xanthine Oxidase and Mediated Amperometric Measurements in the Reduction Mode

    by Madalina-Petruta Bucur, Maria-Cristina Radulescu, Bogdan Bucur, Gabriel Lucian Radu

    A low-interferences enzymatic sensor for evaluating the antioxidant capacity was developed. Xanthine oxidase was used to produce superoxide radicals that spontaneously dismutate to hydrogen peroxide. Low xanthine concentrations were used to minimize the rapid dismutation of the superoxide radical before its fast reaction with antioxidants. The sensor operates in the reduction mode, and evaluations with low interferences of the antioxidant capacity are based on the detection of remaining hydrogen peroxide using Prussian blue electrodes at low potentials. The linear calibration graph is between 2 – 10 μM ascorbic acid. No interferences were observed from easily oxidisable substances including uric acid, which is produced in the enzymatic reaction or other substances usually found in foods. The method was used to evaluate the antioxidant capacity in different real juice samples.


  • Biosensor based on inhibition of monoamine oxidases A and B for detection of β-carbolines

    by Maria-Cristina Radulescu, Madalina-Petruta Bucur, Bogdan Bucur, Gabriel Lucian Radu


  • Electrode-modified with nanoparticles composed of 4,4′-bipyridine-silver coordination polymer for sensitive determination of Hg(ii), Cu(ii) and Pb(ii)

    by Ana Chira, Bogdan Bucur, Madalina Petruta Bucur, Gabriel Lucian Radu

    We have modified a glassy carbon electrode (GCE) with nanoparticles composed of a 4,4′-bipyridine-silver coordination polymer (CP) and showed that this CP can be applied to the sensitive differential pulse voltammetric analysis of the ions Hg(II), Cu(II) and Pb(II). The coordination polymer was prepared by mixing a solution of silver nitrate and 4,4′-bipyridine at room temperature. The surface of the GCE was modified with an organic layer of synthesized 1-[(4-nitrophenyl)methyl]-4,4′-bipyridinium and silver ions, which caused the binding of the added Ag-bipy CP. Anodic (oxidative) peaks of the electrode were at +300 mV for Hg(II), −70 mV for Cu(II), and at −540 mV for Pb(II) [versus Ag/AgCl]. Under optimal conditions, calibration graphs were linear in concentration ranges from 0.2 to 10 μg L−1 for Hg(II), from 1.3 to 6.4 μg L−1 for Cu(II), and from 4.1 to 20.7 μg L−1 for Pb(II). The respective detection limits were 0.09 μg L−1 Hg(II), 0.71 μg L−1 Cu(II) and 2.3 μg L−1 Pb(II). Relative standard deviation was 3.2% at a level of 4 μg L of Hg(II) for n = 10. The modified electrode was applied to the analysis of Hg(II) in spiked fish samples, and of Cu(II), Pb(II), and Hg(II) in spiked plant samples, and recoveries ranged from 90 to 108%. This is the first paper that presents the use of 4,4′-bipyridine-silver coordination polymer for heavy metal electrochemical detection.


  • Open Access

    Bienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis

    by Maria-Cristina Radulescu, Bogdan Bucur, Madalina-Petruta Bucur, Gabriel Lucian Radu

    A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h−1 with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement.