Madalina-Petruta Bucur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Madalina-Petruta Bucur has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Bogdan Bucur
National Institute of Research and Development for Biological Sciences, Centre of Bioanalysis, 296, Splaiul Independentei, 060031, Bucharest, Romania
17 shared publications - Gabriel Lucian Radu
Centre of Bioanalysis, National Institute of Research and Development for Biological Sciences, 296 Splaiul Independentei, 060031 Bucharest, Romania
15 shared publications - Maria-Cristina Radulescu
Centre of Bioanalysis, National Institute of Research and Development for Biological Sciences, 296, Splaiul Independentei, Bucharest 060031, Romania
5 shared publications Maria-Cristina Radulescu
National Institute of Research and Development for Biological Sciences, Center of Bioanalysis, Bucharest, Romania
3 shared publications- Jean-Louis Marty
UFR Sciences, Universite de Perpignan Via Domitia, 52 Avenue Paul Alduy, 66860 Perpignan CEDEX, France
2 shared publications - Ovidiu Ilie Covaci
Sara Pharm Solutions S.R.L., 266-268 Calea Rahovei, Bucharest-5, Romania
2 shared publications
Latest Publications
- Open Access
Cavitation-Effect-Based Treatments and Extractions for Superior Fruit and Milk Valorisation
Ultrasound generates cavities in liquids with high-energy behaviour due to large pressure variations, leading to (bio)chemical effects and material modification. Numerous cavity-based treatments in food processes have been reported, but the transition from research to industrial applications is hampered by specific engineering factors, such as the combination of several ultrasound sources, more powerful wave generators or tank geometry. The challenges and development of cavity-based treatments developed for the food industry are reviewed with examples limited to two representative raw materials (fruit and milk) with significantly different properties. Both active compound extraction and food processing techniques based on ultrasound are taken into consideration.
Open AccessCavitation-Effect-Based Treatments and Extractions for Superior Fruit and Milk Valorisation
Ultrasound generates cavities in liquids with high-energy behaviour due to large pressure variations, leading to (bio)chemical effects and material modification. Numerous cavity-based treatments in food processes have been reported, but the transition from research to industrial applications is hampered by specific engineering factors, such as the combination of several ultrasound sources, more powerful wave generators or tank geometry. The challenges and development of cavity-based treatments developed for the food industry are reviewed with examples limited to two representative raw materials (fruit and milk) with significantly different properties. Both active compound extraction and food processing techniques based on ultrasound are taken into consideration.
- 1 October 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (10) , 106513
Electrochemical Detection Of Heavy Metals In Raw Materials Using a Glassy Carbon Electrode Modified With 4-Aminothiophenol
Sensitive and stable electrodes modified with 4-aminothiophenol were developed for heavy metal detection based on coordination bonds between thiol moieties and analyte. The electrodes were modified using diazonium chemistry in one step modification protocol. The presence of 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) in the electrodeposition media avoids the formation of multilayers and improves the performances due to low surface passivation and good electrochemical transfer at the interface with the solution. Electrodeposition of the organic layer on the electrode surface by chronopotentiometry allowed a good control of the electrode modification process, avoids passivation, and leads to reproducible layers with improved characteristics in comparison with modifications carried out by cyclic voltammetry or chronoamperometry. The electrode was able to detect Pb(II) by differential pulse voltammetry with a linear range of 2.5–400 μ g l −1 and the detection limit of 1.2 μ g l −1 and Cd(II) with the calibration line in the range of 2.5–400 μ g l −1 and a detection limit of 1.5 μ g l −1 . Low interferences were observed and the electrodes were applied for analysis of real samples: fruits pomace and waters.
- 1 October 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (10) , 106513
Electrochemical Detection Of Heavy Metals In Raw Materials Using a Glassy Carbon Electrode Modified With 4-Aminothiophenol
Sensitive and stable electrodes modified with 4-aminothiophenol were developed for heavy metal detection based on coordination bonds between thiol moieties and analyte. The electrodes were modified using diazonium chemistry in one step modification protocol. The presence of 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) in the electrodeposition media avoids the formation of multilayers and improves the performances due to low surface passivation and good electrochemical transfer at the interface with the solution. Electrodeposition of the organic layer on the electrode surface by chronopotentiometry allowed a good control of the electrode modification process, avoids passivation, and leads to reproducible layers with improved characteristics in comparison with modifications carried out by cyclic voltammetry or chronoamperometry. The electrode was able to detect Pb(II) by differential pulse voltammetry with a linear range of 2.5–400 μ g l −1 and the detection limit of 1.2 μ g l −1 and Cd(II) with the calibration line in the range of 2.5–400 μ g l −1 and a detection limit of 1.5 μ g l −1 . Low interferences were observed and the electrodes were applied for analysis of real samples: fruits pomace and waters.
- Open Access
- 2 July 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (42) , 23931-23936
Simple, selective and fast detection of acrylamide based on glutathione S-transferase
Acrylamide (AA) is a toxic compound formed in thermally prepared foods by Maillard reaction. Besides foods, AA may be found in cosmetic products as an impurity of the widely-used non-toxic polyacrylamide. We present a novel, fast and selective detection method based on the amperometric monitoring of the coupling reaction between reduced glutathione (GSH) and AA catalyzed by glutathione S-transferase (GST) to produce an electrochemically inactive compound. We have used electrodes modified with cobalt-phthalocyanine to monitor the decrease of GHS concentration at +300 mV. Our system is simple, does not require supplementary substrates such as 1-chloro-2,4-dinitrobenzene (CDNB) nor have disadvantageous competitive kinetics characteristic to inhibition like signals. Using the optimum concentration of 100 μM GSH we have obtained a linear calibration graph from 7 to 50 μM AA and a limit of detection of 5 μM AA. The method is not affected by interfering compounds usually found in foods and was applied for real sample analysis.
- 2 July 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (42) , 23931-23936
Open AccessSimple, selective and fast detection of acrylamide based on glutathione S-transferase
Acrylamide (AA) is a toxic compound formed in thermally prepared foods by Maillard reaction. Besides foods, AA may be found in cosmetic products as an impurity of the widely-used non-toxic polyacrylamide. We present a novel, fast and selective detection method based on the amperometric monitoring of the coupling reaction between reduced glutathione (GSH) and AA catalyzed by glutathione S-transferase (GST) to produce an electrochemically inactive compound. We have used electrodes modified with cobalt-phthalocyanine to monitor the decrease of GHS concentration at +300 mV. Our system is simple, does not require supplementary substrates such as 1-chloro-2,4-dinitrobenzene (CDNB) nor have disadvantageous competitive kinetics characteristic to inhibition like signals. Using the optimum concentration of 100 μM GSH we have obtained a linear calibration graph from 7 to 50 μM AA and a limit of detection of 5 μM AA. The method is not affected by interfering compounds usually found in foods and was applied for real sample analysis.
- Open Access
- 1 November 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (80) , 50844-50852
Synthesis and retention properties of molecularly imprinted polymers for antibiotics containing a 5-nitrofuran ring
Impedimetric sensor based on molecularly imprinted polymers synthetized for antibiotics containing a 5-nitrofuran ring.
- 1 November 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (80) , 50844-50852
Open AccessSynthesis and retention properties of molecularly imprinted polymers for antibiotics containing a 5-nitrofuran ring
Impedimetric sensor based on molecularly imprinted polymers synthetized for antibiotics containing a 5-nitrofuran ring.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 179-182
Experimental characterization of a high accuracy amperometric sense and control circuit for three-electrode biosensors
A Sense and Control Circuit (SCC) developed for amperometric concentration evaluation is redesigned, based on preliminary experimental investigations. This cost-effective circuit comprises a potentiostat for three-electrode electrochemical cell (biosensor) control and a transimpedance amplifier for cell current sensing. Stability, noise robustness and response time are improved, as demonstrated by experiments and simulations. SCC performances are evaluated in comparison with a professional system, by H2O2 concentration measurements.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 179-182
Experimental characterization of a high accuracy amperometric sense and control circuit for three-electrode biosensors
A Sense and Control Circuit (SCC) developed for amperometric concentration evaluation is redesigned, based on preliminary experimental investigations. This cost-effective circuit comprises a potentiostat for three-electrode electrochemical cell (biosensor) control and a transimpedance amplifier for cell current sensing. Stability, noise robustness and response time are improved, as demonstrated by experiments and simulations. SCC performances are evaluated in comparison with a professional system, by H2O2 concentration measurements.
- 18 February 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 49 (13) , 2006-2017
Electrochemical Determination of Hydrogen Peroxide Using a Prussian Blue-Copper Modified Platinum Microelectrode
Prussian blue modified with copper was electrodeposited on a platinum microelectrode for the amperometric determination of hydrogen peroxide at −50 mV. The Prussian blue-copper layer was stable for 2 h at pH 7.4 and a storage period of 2 months. The Prussian blue-copper modified microelectrodes were used to develop oxidase based microbiosensors for ethanol and lactate. Lactate and alcohol oxidases were immobilized by cross-linking with glutaraldehyde. No interferences were observed from possible interfering compounds up to a concentration of 0.5 mM. The calibration plot of the lactate microbiosensor was linear between 0.005 and 0.2 mM with a limit of detection of 0.0035 mM lactate. The linear dynamic range of the alcohol microbiosensor was between 0.05 and 2 mM and the limit of detection was 0.02 mM ethanol. The developed microbiosensors were used for the analysis of pickled cucumber juice, yogurt, and wine.
- 18 February 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 49 (13) , 2006-2017
Electrochemical Determination of Hydrogen Peroxide Using a Prussian Blue-Copper Modified Platinum Microelectrode
Prussian blue modified with copper was electrodeposited on a platinum microelectrode for the amperometric determination of hydrogen peroxide at −50 mV. The Prussian blue-copper layer was stable for 2 h at pH 7.4 and a storage period of 2 months. The Prussian blue-copper modified microelectrodes were used to develop oxidase based microbiosensors for ethanol and lactate. Lactate and alcohol oxidases were immobilized by cross-linking with glutaraldehyde. No interferences were observed from possible interfering compounds up to a concentration of 0.5 mM. The calibration plot of the lactate microbiosensor was linear between 0.005 and 0.2 mM with a limit of detection of 0.0035 mM lactate. The linear dynamic range of the alcohol microbiosensor was between 0.05 and 2 mM and the limit of detection was 0.02 mM ethanol. The developed microbiosensors were used for the analysis of pickled cucumber juice, yogurt, and wine.
- 10 February 2016
- Published by Springer Nature in Analytical Sciences
- Vol. 32 (2) , 135-139
Low-interferences Determination of the Antioxidant Capacity in Fruits Juices Based on Xanthine Oxidase and Mediated Amperometric Measurements in the Reduction Mode
A low-interferences enzymatic sensor for evaluating the antioxidant capacity was developed. Xanthine oxidase was used to produce superoxide radicals that spontaneously dismutate to hydrogen peroxide. Low xanthine concentrations were used to minimize the rapid dismutation of the superoxide radical before its fast reaction with antioxidants. The sensor operates in the reduction mode, and evaluations with low interferences of the antioxidant capacity are based on the detection of remaining hydrogen peroxide using Prussian blue electrodes at low potentials. The linear calibration graph is between 2 – 10 μM ascorbic acid. No interferences were observed from easily oxidisable substances including uric acid, which is produced in the enzymatic reaction or other substances usually found in foods. The method was used to evaluate the antioxidant capacity in different real juice samples.
- 10 February 2016
- Published by Springer Nature in Analytical Sciences
- Vol. 32 (2) , 135-139
Low-interferences Determination of the Antioxidant Capacity in Fruits Juices Based on Xanthine Oxidase and Mediated Amperometric Measurements in the Reduction Mode
A low-interferences enzymatic sensor for evaluating the antioxidant capacity was developed. Xanthine oxidase was used to produce superoxide radicals that spontaneously dismutate to hydrogen peroxide. Low xanthine concentrations were used to minimize the rapid dismutation of the superoxide radical before its fast reaction with antioxidants. The sensor operates in the reduction mode, and evaluations with low interferences of the antioxidant capacity are based on the detection of remaining hydrogen peroxide using Prussian blue electrodes at low potentials. The linear calibration graph is between 2 – 10 μM ascorbic acid. No interferences were observed from easily oxidisable substances including uric acid, which is produced in the enzymatic reaction or other substances usually found in foods. The method was used to evaluate the antioxidant capacity in different real juice samples.
- 10 September 2014
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 38 (11) , 5641-5646
Electrode-modified with nanoparticles composed of 4,4′-bipyridine-silver coordination polymer for sensitive determination of Hg(ii), Cu(ii) and Pb(ii)
We have modified a glassy carbon electrode (GCE) with nanoparticles composed of a 4,4′-bipyridine-silver coordination polymer (CP) and showed that this CP can be applied to the sensitive differential pulse voltammetric analysis of the ions Hg(II), Cu(II) and Pb(II). The coordination polymer was prepared by mixing a solution of silver nitrate and 4,4′-bipyridine at room temperature. The surface of the GCE was modified with an organic layer of synthesized 1-[(4-nitrophenyl)methyl]-4,4′-bipyridinium and silver ions, which caused the binding of the added Ag-bipy CP. Anodic (oxidative) peaks of the electrode were at +300 mV for Hg(II), −70 mV for Cu(II), and at −540 mV for Pb(II) [versus Ag/AgCl]. Under optimal conditions, calibration graphs were linear in concentration ranges from 0.2 to 10 μg L−1 for Hg(II), from 1.3 to 6.4 μg L−1 for Cu(II), and from 4.1 to 20.7 μg L−1 for Pb(II). The respective detection limits were 0.09 μg L−1 Hg(II), 0.71 μg L−1 Cu(II) and 2.3 μg L−1 Pb(II). Relative standard deviation was 3.2% at a level of 4 μg L of Hg(II) for n = 10. The modified electrode was applied to the analysis of Hg(II) in spiked fish samples, and of Cu(II), Pb(II), and Hg(II) in spiked plant samples, and recoveries ranged from 90 to 108%. This is the first paper that presents the use of 4,4′-bipyridine-silver coordination polymer for heavy metal electrochemical detection.
- 10 September 2014
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 38 (11) , 5641-5646
Electrode-modified with nanoparticles composed of 4,4′-bipyridine-silver coordination polymer for sensitive determination of Hg(ii), Cu(ii) and Pb(ii)
We have modified a glassy carbon electrode (GCE) with nanoparticles composed of a 4,4′-bipyridine-silver coordination polymer (CP) and showed that this CP can be applied to the sensitive differential pulse voltammetric analysis of the ions Hg(II), Cu(II) and Pb(II). The coordination polymer was prepared by mixing a solution of silver nitrate and 4,4′-bipyridine at room temperature. The surface of the GCE was modified with an organic layer of synthesized 1-[(4-nitrophenyl)methyl]-4,4′-bipyridinium and silver ions, which caused the binding of the added Ag-bipy CP. Anodic (oxidative) peaks of the electrode were at +300 mV for Hg(II), −70 mV for Cu(II), and at −540 mV for Pb(II) [versus Ag/AgCl]. Under optimal conditions, calibration graphs were linear in concentration ranges from 0.2 to 10 μg L−1 for Hg(II), from 1.3 to 6.4 μg L−1 for Cu(II), and from 4.1 to 20.7 μg L−1 for Pb(II). The respective detection limits were 0.09 μg L−1 Hg(II), 0.71 μg L−1 Cu(II) and 2.3 μg L−1 Pb(II). Relative standard deviation was 3.2% at a level of 4 μg L of Hg(II) for n = 10. The modified electrode was applied to the analysis of Hg(II) in spiked fish samples, and of Cu(II), Pb(II), and Hg(II) in spiked plant samples, and recoveries ranged from 90 to 108%. This is the first paper that presents the use of 4,4′-bipyridine-silver coordination polymer for heavy metal electrochemical detection.
- Open Access
Bienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis
A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h−1 with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement.
Open AccessBienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis
A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h−1 with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement.