Weiyi Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Weiyi Chen has a total of 404 co-authors. Here are the top co-authors by number of shared publications:
- Xiaona Li
College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, China
20 shared publications Yanqin Wang
College of Artificial Intelligence, Taiyuan University of Technology, Taiyuan, China
14 shared publications- Di Huang
Department of Biomedical Engineering, Research Center for Nano-biomaterials & Regenerative Medicine, Shanxi Key Laboratory of Functional Proteins, College of Artificial Intelligence, Taiyuan University of Technology, Taiyuan, 030024, PR China; Institute of Biomedical Engineering, Shanxi Key Laboratory of Materials Strength & Structural Impact, Taiyuan University of Technology, Taiyuan, 030024, PR China
12 shared publications Xiaochun Wei
Shanxi Key Laboratory of Bone and Soft Tissue Injury Repair, Department of Orthopaedics, The Second Hospital of Shanxi Medical University, Taiyuan, China
12 shared publications- Xiaogang Wu
College of Artificial Intelligence, Taiyuan University of Technology, Taiyuan, China
11 shared publications - Song Chen
College of Artificial Intelligence, Taiyuan University of Technology, Taiyuan, 030024, China
10 shared publications
Latest Publications
- 11 June 2026
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 188, 215014
Hierarchical and porous calcium titanate hydroxide nanosheet nanoflower arrays for enhanced biocompatibility and drug delivery performance
- 11 June 2026
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 188, 215014
Hierarchical and porous calcium titanate hydroxide nanosheet nanoflower arrays for enhanced biocompatibility and drug delivery performance
- 22 May 2026
- Published by Springer Nature in Acta Mechanica Sinica
- Vol. 42 (11) , 625846
Design method for mechanically adaptive re-entrant metamaterials and its application to patient-specific femoral stems
- 22 May 2026
- Published by Springer Nature in Acta Mechanica Sinica
- Vol. 42 (11) , 625846
Design method for mechanically adaptive re-entrant metamaterials and its application to patient-specific femoral stems
- Open Access
- 1 May 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 67 (5) , 64
Biaxial Mechanical Behavior of the Choroid and Its Effect on Ocular Trauma Simulations
Ocular trauma can cause blinding conditions such as choroidal rupture (CR) and retinal detachment (RD). The finite element method (FEM) is widely used to evaluate ocular trauma, but the choroid is often oversimplified because of limited mechanical data, potentially reducing simulation accuracy. This study characterized choroidal mechanical properties and incorporated precise viscoelastic data into ocular trauma simulations. The elastic and viscoelastic properties of the choroid were quantified using biaxial tensile testing. These data were integrated into a finite element model of the human eye incorporating the viscoelastic choroid. BB gun projectile impact simulations were then performed at different speeds to analyze the mechanical responses of posterior ocular tissues. The principal constitutive parameters of the choroid were determined under equibiaxial loading. Simulation results demonstrated that, under identical ocular trauma conditions, inclusion of the choroid altered both scleral and retinal stresses compared with the choroid-excluded eye model, with retinal stress showing a larger change. At an impact speed of 60 m/s, the retinal stress change exceeded 43%. Moreover, the difference in maximum principal stress between the viscoelastic and linear elastic choroid models was 21%, 36%, and 70% at 20, 40, and 60 m/s, respectively. This study provides valuable reference data and a theoretical foundation for understanding the mechanical behavior of the choroid. The proposed computational model underscores the importance of viscoelastic choroid and contributes to improving the accuracy of ocular trauma modeling.
- 1 May 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 67 (5) , 64
Open AccessBiaxial Mechanical Behavior of the Choroid and Its Effect on Ocular Trauma Simulations
Ocular trauma can cause blinding conditions such as choroidal rupture (CR) and retinal detachment (RD). The finite element method (FEM) is widely used to evaluate ocular trauma, but the choroid is often oversimplified because of limited mechanical data, potentially reducing simulation accuracy. This study characterized choroidal mechanical properties and incorporated precise viscoelastic data into ocular trauma simulations. The elastic and viscoelastic properties of the choroid were quantified using biaxial tensile testing. These data were integrated into a finite element model of the human eye incorporating the viscoelastic choroid. BB gun projectile impact simulations were then performed at different speeds to analyze the mechanical responses of posterior ocular tissues. The principal constitutive parameters of the choroid were determined under equibiaxial loading. Simulation results demonstrated that, under identical ocular trauma conditions, inclusion of the choroid altered both scleral and retinal stresses compared with the choroid-excluded eye model, with retinal stress showing a larger change. At an impact speed of 60 m/s, the retinal stress change exceeded 43%. Moreover, the difference in maximum principal stress between the viscoelastic and linear elastic choroid models was 21%, 36%, and 70% at 20, 40, and 60 m/s, respectively. This study provides valuable reference data and a theoretical foundation for understanding the mechanical behavior of the choroid. The proposed computational model underscores the importance of viscoelastic choroid and contributes to improving the accuracy of ocular trauma modeling.
- 16 April 2026
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 185, 214892
One-step fabrication of polycaprolactone microparticle-assembled hierarchical and dual-porous films as cell supporting matrices
- 16 April 2026
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 185, 214892
One-step fabrication of polycaprolactone microparticle-assembled hierarchical and dual-porous films as cell supporting matrices
- Open Access
- 8 April 2026
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 58, 101092
Stress-driven design of intervertebral disc implants and optimization of mechanical and biological performance
- 8 April 2026
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 58, 101092
Open AccessStress-driven design of intervertebral disc implants and optimization of mechanical and biological performance
- Top Cited PapersOpen Access
- 6 February 2026
- Published by Elsevier in The Innovation
- Vol. 7 (4)
Transformative biomechanics and mechanobiology breakthroughs shaping the future of health and medicine
- 6 February 2026
- Published by Elsevier in The Innovation
- Vol. 7 (4)
Top Cited PapersOpen AccessTransformative biomechanics and mechanobiology breakthroughs shaping the future of health and medicine
- Open Access
- 2 February 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 15 (2) , 27
In Vivo Evaluation of Efficacy and Safety of Oxygen-Supplemented Accelerated Scleral Cross-Linking Over Time in Young Rabbits
To evaluate the efficacy and safety of riboflavin-ultraviolet A scleral cross-linking surgery over time in vivo using an accelerated protocol with supplemental oxygen. This study compared accelerated scleral collagen cross-linking (A-SXL) plus 90% O2 (30 mW/cm2 for 3 minutes with 90% oxygen supplementation) to the traditional protocol (T-SXL; 3 mW/cm2 for 30 minutes) in young New Zealand White rabbits. The right eye underwent surgery, and the left eye served as an intraindividual control. At different time points, efficiency was evaluated through spherical equivalent refraction (SER), axial length (AL), and scleral tangent modulus, and safety was assessed via electroretinogram (ERG) and hematoxylin and eosin (H&E) staining. The A-SXL+90% O2 protocol significantly preserved refractive power and inhibited axial elongation over the 3-month postoperative period, and no statistically significant differences were detected when compared with the T-SXL group (P > 0.05). Moreover, the A-SXL+90% O2 protocol led to a significant increase in scleral tangent modulus at both 1 month and 3 months post-surgery, similar to the outcomes seen with T-SXL. ERG and H&E staining revealed no evidence of retinal functional impairment or histological alterations in posterior ocular tissues (sclera, choroid, and retina) in both scleral cross-linking protocols. A-SXL supplemented with oxygen offers a faster, effective, and relatively safe alternative to T-SXL in vivo by demonstrating sustained biomechanical reinforcement with an acceptable safety profile. A-SXL supplemented with oxygen may be a promising therapeutic approach for scleral weakening disorders such as progressive high myopia.
- 2 February 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 15 (2) , 27
Open AccessIn Vivo Evaluation of Efficacy and Safety of Oxygen-Supplemented Accelerated Scleral Cross-Linking Over Time in Young Rabbits
To evaluate the efficacy and safety of riboflavin-ultraviolet A scleral cross-linking surgery over time in vivo using an accelerated protocol with supplemental oxygen. This study compared accelerated scleral collagen cross-linking (A-SXL) plus 90% O2 (30 mW/cm2 for 3 minutes with 90% oxygen supplementation) to the traditional protocol (T-SXL; 3 mW/cm2 for 30 minutes) in young New Zealand White rabbits. The right eye underwent surgery, and the left eye served as an intraindividual control. At different time points, efficiency was evaluated through spherical equivalent refraction (SER), axial length (AL), and scleral tangent modulus, and safety was assessed via electroretinogram (ERG) and hematoxylin and eosin (H&E) staining. The A-SXL+90% O2 protocol significantly preserved refractive power and inhibited axial elongation over the 3-month postoperative period, and no statistically significant differences were detected when compared with the T-SXL group (P > 0.05). Moreover, the A-SXL+90% O2 protocol led to a significant increase in scleral tangent modulus at both 1 month and 3 months post-surgery, similar to the outcomes seen with T-SXL. ERG and H&E staining revealed no evidence of retinal functional impairment or histological alterations in posterior ocular tissues (sclera, choroid, and retina) in both scleral cross-linking protocols. A-SXL supplemented with oxygen offers a faster, effective, and relatively safe alternative to T-SXL in vivo by demonstrating sustained biomechanical reinforcement with an acceptable safety profile. A-SXL supplemented with oxygen may be a promising therapeutic approach for scleral weakening disorders such as progressive high myopia.
- 9 October 2025
- Published by Elsevier in Experimental Eye Research
- Vol. 261, 110684
Increased efficacy of accelerated corneal collagen crosslinking in rabbit ectasia models due to higher oxygen availability
- 9 October 2025
- Published by Elsevier in Experimental Eye Research
- Vol. 261, 110684
Increased efficacy of accelerated corneal collagen crosslinking in rabbit ectasia models due to higher oxygen availability
- 25 September 2025
- Published by Elsevier in Journal of Photochemistry and Photobiology B: Biology
- Vol. 272, 113272
A theoretical model for optimizing UVA/riboflavin crosslinking
- 25 September 2025
- Published by Elsevier in Journal of Photochemistry and Photobiology B: Biology
- Vol. 272, 113272
A theoretical model for optimizing UVA/riboflavin crosslinking
- 9 August 2025
- Published by Elsevier in Experimental Eye Research
- Vol. 259, 110575
Evaluation of different residual stromal bed thickness on long-term in vivo corneal biomechanics following SMILE in rabbits
- 9 August 2025
- Published by Elsevier in Experimental Eye Research
- Vol. 259, 110575
Evaluation of different residual stromal bed thickness on long-term in vivo corneal biomechanics following SMILE in rabbits