KKKatharina Klaus

Katharina Klaus

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Katharina Klaus has a total of 28 co-authors. Here are the top co-authors by number of shared publications:

  • Sabine Ruf

    Department of Orthodontics, Dental Clinic of the Justus Liebig University Giessen, Giessen, Germany

    9 shared publications
  • Sabine Ruf

    Department of Orthodontics, Justus Liebig University Giessen, Giessen, Germany

    7 shared publications
  • Bernd Wöstmann

    Department of Prosthodontics, Justus Liebig University Giessen, Schlangenzahl 14, 35392 Giessen, Germany

    2 shared publications
  • Carolina Ganss

    Department of Operative Dentistry, Endodontology, and Paediatric Dentistry, University of Marburg , Marburg , Germany

    2 shared publications
  • Maximiliane Amelie Schlenz

    Department of Prosthodontics, Christian Albrecht University of Kiel, University Hospital Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, 24105 Kiel, Germany

    2 shared publications
  • Nelly Schulz-Weidner

    Department for Pediatric Dentistry, Justus Liebig University Giessen, Schlangenzahl 14, 35392 Giessen, Germany

    2 shared publications

Latest Publications

  • Open Access

    Capturing of interdental areas with digital and conventional impression systems and their impact on automatic tooth segmentation in CAD software: an in vitro study

    by Katharina Klaus, Linus Vincent Hardt, Bernd Wöstmann, Sabine Ruf, Maximiliane Amelie Schlenz

    Objectives: This in vitro study evaluated and compared the accuracy of digital versus conventional impression systems in reproducing interdental areas (IAs) of periodontally compromised dentitions (PCDs) and examined how impression quality influences automated tooth segmentation in CAD software. Materials and methods: A standardized PCD model was captured with one conventional polyvinylsiloxane impression (CVI), four wireless intra‑oral scanners (IOS) - Dexis IS 3800 W (3800‑wl), Medit i700w (i700‑wl), Primescan 2 (PRI2‑wl), Trios 5 (TRI5‑wl) - and a wired Primescan AC (PRI1‑w). Raw scan data, digitally mounted casts after scan‑repair, and digital casts after tooth segmentation in OnyxCeph were analyzed. IA reproduction accuracy and segmentation quality were statistically compared using the Median test and Chi‑squared test ( p < 0.05). Results: All IOS reproduced IAs significantly more accurately than the CVI ( p < 0.001). Among IOS, PRI2‑wl achieved > 80% correct IA reproduction, whereas 3800‑wl and TRI5‑wl fell short by up to 20%. Scan‑repair marginally improved IA capture for some IOS, while the conventional impression showed no change. Segmentation errors clustered in teeth with pronounced gingival recession; healthy gingiva yielded higher accuracy. Significant differences between raw and segmented data were found for TRI5‑wl ( p = 0.027) and 3800‑wl ( p = 0.044). Conclusions: Within the limits of this in vitro study, IOS outperform conventional impressions for IA reproduction in PCDs. Accuracy varies among IOS and is linked to raw‑scan quality. Automated segmentation is reliable for teeth with healthy gingiva but is challenged by periodontal defects. Clinical Relevance: Precise IA capture enhances orthodontic movement planning and streamlines CAD‑based workflows, reducing manual corrections and improving outcomes for patients with compromised periodontium.

  • Open Access

    Caries risk trajectories in a changing oral health landscape. A longitudinal study of orthodontic patients across four decades

    by Carolina Ganss, Niko C Bock, Katja Jung, Katharina Klaus, Sabine Ruf, Nelly Schulz-Weidner

  • Open Access

    Interproximal accuracy of CAD/CAM machine cut, machine bent and manually bent retainers

    by Katharina Klaus, Jan Dirk Pollmeier, Sabine Ruf

    Aim: The purpose of the present study was to compare the interproximal accuracy (IA) of two different CAD/CAM (computer-aided design/computer-aided manufacturing) manufactured and conventionally bent retainers. Materials and methods: On 20 digitized debonding casts (10 upper, 10 lower), a canine-to-canine retainer was designed using two different CAD/CAM software: OnyxCeph ® (Image Instruments, Chemnitz, Germany) and FixR™ (YOAT Corp., Lynnwood, WA, USA). Each design was bent using the Bender II™ retainer bending machine (YOAT Corp.) and 3‑ or 6‑stranded twistflex wires (0.018-inch Dentaflex ® , Dentaurum, Ispringen, Germany), respectively. For each cast, one CAD/CAM machine cut retainer (Memotain ® , SCHEU DENTAL custom-made, Hilden, Germany) was fabricated and one retainer was bent manually by a dental technician using the 6‑stranded wire. All retainers were passively waxed on the dental casts and digitized using a laboratory scanner (Atos, Carl Zeiss IQS Deutschland, Oberkochen, Germany). For each of the five interproximal areas, IA was measured (1) as vertical distance between retainer and the reference retainer plane and (2) as horizontal distance between the interproximal reference point and the retainer in millimeters. For both directions, it was assumed that the smaller the distance, the higher the interproximal accuracy of the retainer. Statistical analysis was performed using Mann–Whitney and Kruskal–Wallis tests. Results: Considering the vertical deviation, significant differences of interproximal accuracy were seen between the jaws (upper 0.25 mm > lower 0.18 mm, p < 0.001), planning software (FixR 0.25 mm > OnyxCeph 0.21 mm, p = 0.03) and settings (upper jaw: CAD/CAM bent [FixR] 0.34–0.32 mm > manually bent 0.27 mm > CAD/CAM bent [Onyx] 0.23–0.18 mm > CAD/CAM cut 0.17 mm, p = 0.001; lower jaw: CAD/CAM bent [FixR 3‑stranded and Onyx] 0.22–0.21 mm > manually bent 0.18 mm > CAD/CAM bent [FixR 6‑stranded] 0.13 mm > CAD/CAM cut 0.10 mm, p = 0.004). For horizontal deviation, significant differences were observed between the jaws (upper 0.97 mm > lower 0.66 mm, p < 0.001), planning software (OnyxCeph 0.90 mm > FixR 0.72 mm, p < 0.001), settings (upper jaw: CAD/CAM bent [Onyx] = CAD/CAM cut 1.16–1.10 mm > CAD/CAM bent [FixR] 0.96–0.89 mm > manually bent 0.76 mm, p < 0.001; lower jaw: CAD/CAM bent [Onyx] 0.84–0.71 mm > CAD/CAM cut 0.66 mm = CAD/CAM bent [FixR] 0.66–0.63 mm > manually bent 0.51 mm, p < 0.001) and location of the interdental area in the upper jaw (13–12 = 22–23 > 22–21 > 11–21 > 12–11, p < 0.001). The wire quality had no significant impact in either of the dimensions. Conclusion: Interproximal accuracy in the vertical plane was achieved best by CAD/CAM cut retainers, while horizontally, manually bent retainers were the most accurate. Overall, the accuracy of lower retainers seems clinically acceptable for their use in the mandible irrespective of the manufacturing method, whereas maxillary retainers presented a larger variability especially in the more distal interproximal areas.


  • Open Access

    Three-dimensional analysis of posttreatment tooth movements despite bonded retainers: part I—upper jaw

    by Katharina Klaus, Tobias Kleinert, Sabine Ruf

    Purpose: Adverse side effects of fixed retainers in terms of unwanted tooth movements have been described for both the upper and lower jaw, but data about the extent and movement patterns for the maxilla are scarce. The purpose of the present retrospective case–control study was to analyze the amount and direction of unwanted tooth movements despite upper bonded retainers as well as to analyze possible predisposing pretreatment- and treatment-related factors. Methods: Plaster casts of 1026 patients who completed orthodontic treatment and a subsequent retention phase of 2 years were screened for unintentional tooth movements. The study group comprised 57 patients with visually obvious tooth movements in the upper jaw, while 57 randomly selected patients without visible tooth movements served as control group. For all patients, plaster casts after debonding of multibracket appliance (T1) and after supervised retention (T2) were digitized, and superimposed digitally using a stable palatal reference area. Thereafter, translational and rotational movements were measured in all three planes of space. Pretreatment- and treatment-related factors of the study and control groups were compared by χ 2 test, exact Fisher test, Mann–Whitney U test, and the T‑test for independent samples. Results: The mean translational movements ranged between 0 and 0.6 mm and the average rotational movements between 0 and 1.3°. Large individual movements up to 2.7 mm translation and 15.9° rotation were seen. A movement pattern around the Y‑ and Z‑axis with an opposite rotational peak at the canines (“upper twist effect”) was identified. Compared to the control group, patients of the study group showed a significantly smaller intercanine width pretreatment. Also, study group patients presented a larger intercanine expansion and a slightly larger overjet reduction during treatment, and were more often affected by retainer bonding site detachments and wire fractures, but without reaching statistically significance. Conclusion: Upper bonded retainers show a similar unwanted movement pattern (“twist effect”) like the one described for mandibular retainers.


  • Open Access

    Three-dimensional analysis of posttreatment tooth movements despite bonded retainers: part II—lower jaw

    by Katharina Klaus, Tobias Kleinert, Sabine Ruf

    Purpose: Complications of bonded lingual retainers in terms of unexpected tooth movements have been reported with increasing frequency during the last decade, but the vast majority of the literature comprises case reports. The purpose of the present retrospective case–control study was to analyze the amount and direction of unwanted tooth movements despite lower bonded retainers, to analyze possible predisposing pretreatment- and treatment-related factors, and to seek for movement thresholds which could enhance the rapid and objective identification of critical cases. Methods: Plaster casts of 1026 patients who completed orthodontic treatment and a subsequent retention phase of 2 years were screened for unintentional tooth movements. The study group comprised 39 patients with tooth movements in the lower jaw, while 39 randomly selected patients without visible tooth movements served as the control group. For all patients, plaster casts after debonding of multibracket appliances (T1) and after supervised retention (T2) were digitized, and a three-dimensional (3D) digital superimposition based on the best fit of premolars and molars was undertaken. Thereafter, translational as well as rotational movements were measured in all three planes of space. Pretreatment- and treatment-related factors of the study and control groups were compared. A severity classification based on rotational movement thresholds was applied to seek a critical amount of translational movements. Results: The mean translational movements ranged between 0 and 0.4 mm and the average rotational movements between 0 and 1.6°. Large individual movements up to 1.9 mm translation and 16° rotation were seen. A twist-effect with opposite movements of the canines along the Y‑axis could be confirmed. Compared to the control group, patients of the study group had a smaller intercanine distance at all timepoints. In addition, study group patients presented a slightly larger intercanine expansion during treatment and were more often affected by retainer bonding site detachments. Applying the severity classification based on rotational thresholds, translational movements of 0.5–1.0 mm along the X‑ and Y‑axis could serve as a critical threshold. It can be assumed that extrusive translational movements along the Z‑axis seem to be of specific nature and perhaps do not reflect a retainer complication in terms of unwanted tooth movements. Conclusions: Patients with a larger intercanine distance after active treatment and those with more frequent retainer bonding site detachments could be at higher risk for unwanted tooth movements during fixed retention. Sagittal and transverse movements of 0.5–1.0 mm should sensitize the practitioner for further measures.


  • White spot lesions after fixed appliance treatment—Can we expect spontaneous long-term (≥15 years) improvement?

    by Niko Christian Bock, Julia von Bremen, Katharina Klaus, Nelly Schulz-Weidner, Carolina Ganss, Sabine Ruf

    Summary: Objective: To investigate the extent to which post-orthodontic white spot lesions (WSLs) change in appearance over a period of ≥15 years and whether an association with caries data exists. Subjects and Methods: Seventy-two patients treated with a Herbst-Multibracket appliance at age 14.0 ± 2.7 years for 20.1 ± 5.1 months who attended a recall 18.3 ± 2.9 years post-treatment. Post-treatment (T1) intraoral photographs were assessed by a panel of five dentists using a modified version of the WSL-Index by Gorelick. For affected incisors, photographs from before treatment (T0) and recall (T3) were evaluated. In addition, the WSL-Change Index by Pancherz and Muehlich was assessed for all adequately visible incisors considering T1, T2 (if available), and T3. Radiographic (T0, T1, and T2—if available) and clinical (T3) MFT data were used. Results: 37.5% of the patients exhibited WSLs on ≥ 1 incisor at T1; in total, 81 incisors (14.9%) were affected. At T3, 48% of the WSLs had improved. The modified WSL-Index decreased from 1.2 ± 0.4 to 0.8 ± 0.6 (P < .001), with a score 0 in 28% of the previously affected incisors. When comparing T2 vs. T3, additional improvement after T2 occurred in 11% of the teeth. While no difference existed at T0, the MFT values at T1, T2, and T3 were higher (P ≤ .05) in patients with WSLs at T1 than in those without. Limitations: The homogeneity of the subjects was limited and no patient-reported outcome was assessed. Conclusions: Long-term, post-orthodontic WSLs showed spontaneous full recovery in 28% and improvement in 48% of the teeth. Patients affected with WSLs exhibited higher post-treatment MFT values.


  • Open Access

    What to Prefer in Patients with Multibracket Appliances? Digital vs. Conventional Full-Arch Impressions—A Reference Aid-Based In Vivo Study

    by Niko Christian Bock, Katharina Klaus, Moritz Maximilian Liebel, Sabine Ruf, Bernd Wöstmann, Maximiliane Amelie Schlenz

    This study aimed to investigate the transfer accuracy and required time for digital full-arch impressions obtained from intraoral scanners (IOSs) versus conventional alginate impressions (CAIs) in patients with multibracket appliances (MBA). Thirty patients with buccal MBAs (metal brackets, archwire removed) were examined using an established reference aid method. Impression-taking using four IOSs (Primescan, Trios 4, Medit i700, Emerald S) and one CAI with subsequent plaster casting were conducted. One-hundred-twenty (n = 30 × 4) scans were analyzed with 3D software (GOM Inspect) and 30 (n = 30 × 1) casts were assessed using a coordinate measurement machine. Six distances and six angles were measured and compared to the reference aid values (ANOVA; p < 0.05). Except for the intermolar distance, transfer accuracy was significantly higher with IOSs than with CAIs (p < 0.05). No such difference was found regarding the six angles. In patients with MBAs, digital impression-taking using IOSs can be recommended. For all measured variables except one, the transfer accuracy of IOSs was better than or at least equivalent to the data from CAIs. In addition, significantly (p < 0.001) less time was necessary for all IOSs in comparison to CAIs plus plaster casting.


    • 1 December 2022
      • Vol. 56  (12) , 1000

    Unexpected tooth movement under bonded retainers.

    by Katharina Klaus, Sabine Ruf