  • Portable capillary LC for in‐line UV monitoring and MS detection: Comparable sensitivity and much lower solvent consumption

    by Michael B. Hicks, Keith Mattern, Jonathan Fine, Shane Grosser, Daya Patel, Lauren Weisel, Pankaj Aggarwal

    Pharmaceutical development currently relies on quality separation methods from early discovery through to line‐of‐site manufacturing. There have been significant advancements made regarding the column particle packing, internal diameter, length connectivity, the understanding of the impact key parameters like void volume, flow rate, and temperature all that affects the resultant separation quality, that is, resolution, peak shape, peak width, run time, and signal‐to‐noise ratio. There is however a strong need to establish better alternatives to large bulky high‐performance liquid chromatography racks either for process analytical reaction monitoring or mass spectrometry analysis in establishing product quality. Compact, portable high‐pressure liquid chromatography can be a more efficient alternative to traditional ultra‐high pressure liquid chromatography and traditional liquid chromatography. The compact versatile instrument evaluated here allows good separation control with either the on‐board column with fixed ultra‐violet wavelength cartridge or for use with a high‐resolution mass spectrometry. Significant space reduction results in greener lab spaces with improved energy efficiency for smaller labs with lower energy demands. In addition, this compact liquid chromatography was used as a portable reaction monitoring solution to compare forced degradation kinetics and assess portable liquid chromatography‐mass spectrometry capability for the analyses required for pharmaceutical drug product testing.


  • A Diagnostic Nitrosamine Detection Approach for Pharmaceuticals by Using Tandem Mass Spectrometry Based on Diagnostic Gas-Phase Ion-Molecule Reactions

    by Judy Kuan-Yu Liu, Erlu Feng, Yue Fu, Wanru Li, Xin Ma, Huaming Sheng, John Kong, Yong Liu, Michael Hicks, Bangping Xiang, et al.

    N-Nitrosamines are strictly regulated in pharmaceutical products due to their carcinogenic nature. Therefore, the ability to rapidly and reliably identify the N-nitroso functionality is urgently needed. Unfortunately, not all ionized N-nitroso compounds produce diagnostic fragment ions and hence tandem mass spectrometry based on collision-activated dissociation (CAD) cannot be used to consistently identify the N-nitroso functionality. Therefore, a more reliable method was developed based on diagnostic functional-group selective ion-molecule reactions in a linear quadrupole ion trap mass spectrometer. 2-Methoxypropene (MOP) was identified as a reagent that reacts with protonated N-nitrosamines in a diagnostic manner by forming an adduct followed by the elimination of 2-propenol (CH3C(OH)═CH2]). From 18 protonated N-nitrosamine model compounds studied, 15 formed the diagnostic product ion. The lack of the diagnostic reaction for three of the N-nitrosamine model compounds was rationalized based on the presence of a pyridine ring that gets preferentially protonated instead of the N-nitroso functionality. These N-nitrosamines can be identified by subjecting a stable adduct formed upon ion-molecule reactions with MOP to CAD. Further, the ability to use ion-molecule reactions followed by CAD to differentiate protonated O-nitroso compounds with a pyridine ring from analogous N-nitrosamines was demonstrated This methodology is considered to be robust for the identification of the N-nitroso functionality in unknown analytes. Lastly, HPLC/MS2 experiments were performed to determine the detection limit for five FDA regulated N-nitrosamines.


  • Life cycle analysis and sustainability comparison of reversed phase high performance liquid chromatography and carbon dioxide-containing chromatography of small molecule pharmaceuticals

    by Brian N. Fitch, Rebekah Gray, Martin Beres, Michael B. Hicks, William Farrell, Christine Aurigemma, Susan V. Olesik

    The greenness of a chromatographic separation is typically determined by examining the solvent selection and the quantity of solvent used. Carbon dioxide is often touted as a green alternative to organic solvents typically used in chromatography. However, this claim does not consider the additional instrumentation and energy requirements needed for its use in supercritical fluid chromatography (SFC) compared to alternative methods such as reversed phase (RP) high-performance liquid chromatography (HPLC). This work demonstrates the importance of considering not just the solvent usage but also the instrumental energy consumption especially at the analytical scale where it can account for the majority of the emissions of the system. Two methods that use a more holistic characterization of greenness are life cycle analysis (LCA) and the analytical method greenness score (AMGS). The AMGS calculator is a relatively new method of determining greenness so the result from the AMGS calculator is benchmarked to the LCA results. The greenness of both chromatographic systems are compared at both the analytical and preparative scale for the separation of small molecule drug molecules. In general, SFC separations at low flow rates (−1) performed unfavorably when compared to comparable RP-HPLC separations. The influence of chromatographic conditions for SFC, such as flow rate and higher back pressures, are shown to improve the overall greenness of this technique. SFC separations were in general favorable or at least comparable to the RP-HPLC separations when the SFC separations were faster. Lastly, the electrical energy sources used for instruments were demonstrated to reduce the impact of instrument energy consumption at all scales.


  • Improving the environmental hazard scores metric for solvent mixtures containing carbon dioxide for chromatographic separations

    by Rebekah Gray, Brian Fitch, Christine Aurigemma, Michael B. Hicks, Martin Beres, William Farrell, Susan V. Olesik

    Quantifying the greenness of chromatographic separations using CO2 in the mobile phase.


  • Diminishing GSH-Adduct Formation of Tricyclic Diazepine-based Mutant IDH1 Inhibitors

    by Chunhui Huang, Christian Fischer, Michelle R. Machacek, Stephane Bogen, Tesfaye Biftu, Xianhai Huang, Michael H. Reutershan, Ryan Otte, Qingmei Hong, Zhicai Wu, et al.

    Mutant isocitrate dehydrogenase 1 (IDH1) has been identified as an attractive oncology target for which >70% of grade II and III gliomas and ∼10% of acute myeloid leukemia (AML) harbor somatic IDH1 mutations. These mutations confer a neomorphic gain of function, leading to the production of the oncometabolite (R)-2-hydroxyglutarate (2-HG). We identified and developed a potent, selective, and orally bioavailable brain-penetrant tricyclic diazepine scaffold that inhibits mutant IDH1. During the course of in vitro metabolism studies, GSH-adduct metabolites were observed. The hypothesis for GSH-adduct formation was driven by the electron-rich nature of the tricyclic core. Herein, we describe our efforts to reduce the electron-rich nature of the core. Ultimately, a strategy focused on core modifications to block metabolic hot spots coupled with substitution pattern changes (C8 N → C linked) led to the identification of new tricyclic analogues with minimal GSH-adduct formation across species while maintaining an overall balanced profile.


  • Open Access

    Correction: Making the move towards modernized greener separations: introduction of the analytical method greenness score (AMGS) calculator

    by Michael B. Hicks, William Farrell, Christine Aurigemma, Laurent Lehmann, Lauren Weisel, Kelly Nadeau, Heewon Lee, Carol Moraff, Mengling Wong, Yun Huang, et al.

    Correction for ‘Making the move towards modernized greener separations: introduction of the analytical method greenness score (AMGS) calculator’ by Michael B. Hicks et al. , Green Chem. , 2019, 21 , 1816–1826, DOI: 10.1039/C8GC03875A.


  • Advanced reaction monitoring of pharmaceutical processes enabled with sub/supercritical fluid chromatography

    by Michael B. Hicks, Weidong Tong, Jason Kowalski, Akasha K. Purohit, Jimmy DaSilva, Erik L. Regalado


  • Top Cited Papers

    Making the move towards modernized greener separations: introduction of the analytical method greenness score (AMGS) calculator

    by Michael B. Hicks, William Farrell, Christine Aurigemma, Laurent Lehmann, Lauren Weisel, Kelly Nadeau, Heewon Lee, Carol Moraff, Mengling Wong, Yun Huang, et al.

    Green and sustainable processes to develop and manufacture pharmaceuticals using eco-friendly and environmentally responsible means have been underway for over 25 years. These include the major analytical chemistry techniques used for pharmaceutical characterization. The pharmaceutical industry as a whole needs to responsibly transition away from traditional chromatographic methodologies that include the use of longer columns, extended run times, toxic non-polar solvents (e.g. heptanes and hexanes for normal phase liquid chromatography) and their accompanying large solvent volume consumption - toward more efficient, greener solutions. Over the last decade, high pressure liquid chromatography (HPLC) and supercritical fluid chromatography (SFC) techniques have undergone substantial improvements to instrumentation (e.g. UHPLC and UHPSFC) and column particle technologies, all of which lead to faster and more efficient separations while reducing development and validation time for both chiral and achiral analyses. However, many of these advances have yet to be globally adopted in later stage drug development and manufacturing where chromatographic process usage requires multiple analyses for every method transfer, validation, and clinical supply campaign. In order to emphasize greener method alternatives, we introduce a new approach to definitively establish the impact of method design and instrument selection choices. Our aim is to provide awareness and guidance to the global industry with a single unified, straightforward metric that clearly shows the benefit of selecting more modernized, safer and more environmentally-friendly methods and techniques without compromising separation performance.


  • Assessment of coulometric array electrochemical detection coupled with HPLC-UV for the absolute quantitation of pharmaceuticals

    by Michael B. Hicks, Leah Salituro, Ian Mangion, Wes Schafer, Rong Xiang, Xiaoyi Gong, Christopher J. Welch

    The use of a coulometric array detector in tandem with HPLC-UV was evaluated for the absolute quantitation of pharmaceutical compounds without standards, an important capability gap in contemporary pharmaceutical research and development. The high-efficiency LC flow-through electrochemical detector system allows for the rapid evaluation of up to 16 different potentials, aiding in the identification and quantitation of electrochemically reactive species. By quantifying the number of electrons added or removed from an analyte during its passage through the detector, the number of moles of the analyte can be established. Herein we demonstrate that molecules containing common electroactive functional groups (e.g. anilines, phenols, parabens and tertiary alkyl amines) can in some cases be reliably quantified in HPLC-EC-UV without the need for authentic standards. Furthermore, the multichannel nature of the CoulArray detector makes it well suited for optimizing the conditions for electrochemical reaction, allowing the impact of changes in potential, flow rate, temperature and pH to be conveniently studied. The electrochemical oxidation of albacivir, zomepirac, diclofenac, rosiglitazone and several other marketed drugs resulted in large linear ranges, predictable recoveries and excellent quantitation using the total moles of electrons and back-calculating using Faraday's law. Importantly, we observed several instances where subtle structural changes within a given class of molecules (e.g. aromatic ring isomers) led to unanticipated changes in electrochemical behavior. Consequently, some care should be taken when applying the technique to the routine quantitation of compound libraries where standards are not available.