Harald Brünig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Harald Brünig has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Andreas Leuteritz
Leibniz Institute of Polymer Research Dresden (IPF), Hohe Straße 6, 01069 Dresden, Germany
1 shared publicationB. Tändler
Institute of Polymer Research Dresden, Hohe Strasse 6, D‐01069 Dresden, Germany
1 shared publication- Christina Scheffler
Leibniz-Institut für Polymerforschung Dresden e.V.
1 shared publication - Florian Wieczorek
Technische Universität Dresden
1 shared publication - Iurie Curosu
Ruhr‐Universität Bochum Lehrstuhl für Baustofftechnik Universitätsstraße 150 44801 Bochum
1 shared publication - Leo Braack
Faculty of Tropical Medicine, Malaria Consortium, Mahidol University, Bangkok, Thailand
1 shared publication
Latest Publications
- 5 September 2021
- Published by Springer Nature
- p. 255-264
Spinability and Characteristics of Particle-Shell PP-bicomponent Fibers for Crack Bridging in Mineral-Bonded Composites
- 5 September 2021
- Published by Springer Nature
- p. 255-264
Spinability and Characteristics of Particle-Shell PP-bicomponent Fibers for Crack Bridging in Mineral-Bonded Composites
- 1 October 2018
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 91, 754-761
Bicomponent fibres for controlled release of volatile mosquito repellents
- 1 October 2018
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 91, 754-761
Bicomponent fibres for controlled release of volatile mosquito repellents
- 1 July 2004
- Published by Wiley in Advances in Polymer Technology
- Vol. 23 (3) , 176-185
Online temperature measurement and simultaneous diameter estimation of fibers by thermography of the spinline in the melt spinning process
Online measurements of the temperature and the diameter of fibers in the melt spinning process of thermoplastics are discussed. The temperature and the diameter of fibers can be applied in many fields such as fiber formation modelling, cooling rate behavior (Nusselt number), and rheological investigations (apparent extensional viscosity) of polymers. The online measurements along the spinline were carried out with an infrared camera during the melt spinning process. Two different experiments were designed and carried out to find the correction factor, i.e., the emissivity. The results show that the emissivity correction factor depends on the polymer type and the fiber diameter. Usually the diameter of the fibers is measured by an instrument or by direct velocity measurements invoking the continuity equation. In this new approach the diameter is found directly by the evaluation of the measured temperature. Therefore only one apparatus, namely an infrared camera taking snapshots, is required to find the fiber diameter. The key of this method can be seen in the temperature difference between the fiber and the environment. A mathematical procedure was developed to estimate the diameter of the fiber from the distribution curve. © 2004 Wiley Periodicals, Inc. Adv Polym Techn 23: 176–185, 2004; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/adv.20008
- 1 July 2004
- Published by Wiley in Advances in Polymer Technology
- Vol. 23 (3) , 176-185
Online temperature measurement and simultaneous diameter estimation of fibers by thermography of the spinline in the melt spinning process
Online measurements of the temperature and the diameter of fibers in the melt spinning process of thermoplastics are discussed. The temperature and the diameter of fibers can be applied in many fields such as fiber formation modelling, cooling rate behavior (Nusselt number), and rheological investigations (apparent extensional viscosity) of polymers. The online measurements along the spinline were carried out with an infrared camera during the melt spinning process. Two different experiments were designed and carried out to find the correction factor, i.e., the emissivity. The results show that the emissivity correction factor depends on the polymer type and the fiber diameter. Usually the diameter of the fibers is measured by an instrument or by direct velocity measurements invoking the continuity equation. In this new approach the diameter is found directly by the evaluation of the measured temperature. Therefore only one apparatus, namely an infrared camera taking snapshots, is required to find the fiber diameter. The key of this method can be seen in the temperature difference between the fiber and the environment. A mathematical procedure was developed to estimate the diameter of the fiber from the distribution curve. © 2004 Wiley Periodicals, Inc. Adv Polym Techn 23: 176–185, 2004; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/adv.20008