Delmira Beatriz Wolff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Delmira Beatriz Wolff has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Samara Terezinha Decezaro
Universidade Federal de Santa Maria
5 shared publications - Valdemir Fonseca da Silva
Universidade Federal de Santa Maria
4 shared publications - Elvis Carissimi
Universidade Federal de Santa Maria, Brazil
3 shared publications - Orlando de Carvalho Junior
Universidade Tecnológica Federal do Paraná, Brasil
3 shared publications - Pablo Heleno Sezerino
Universidade Federal de Santa Catarina - Florianópolis - Santa Catarina - Brasil
3 shared publications - Ronaldo Kanopf de Araújo
Universidade Federal de Santa Maria, Brasil
3 shared publications
Latest Publications
- Open Access
- 8 January 2025
- Published by Revista de Ciencia e Inovacao in Revista de Ciência e Inovação
- Vol. 11 (1) , 1-25
Estudo comparativo e espacialização do parâmetro CN (curve number) na bacia hidrográfica do rio do Turvo, Rio Grande do Sul, entre os anos de 1990, 2006 e 2022
Este estudo investigou o uso da metodologia Curve Number (CN) para avaliar o escoamento superficial na bacia hidrográfica do rio do Turvo, no Rio Grande do Sul, Brasil, nos anos de 1990, 2006 e 2022. Utilizando dados de uso e cobertura do solo e informações pedológicas, foram correlacionados os padrões de uso da terra com as características hidrológicas dos solos, gerando mapas que representam a distribuição espacial do CN nos períodos analisados. Os resultados evidenciaram transformações no uso da terra, destacando-se o aumento das áreas urbanas em cerca de 260% no período e 50% no cultivo de soja. Consequentemente, houve um avanço progressivo no valor de CN ao longo dos anos, indicando o aumento do escoamento superficial, influenciado principalmente pelo tipo de cobertura do solo. Os resultados obtidos evidenciam a urgência de ações de conservação do solo e da vegetação nativa na região. O estudo demonstra a importância da metodologia CN para a avaliação dos processos hidrológicos em bacias hidrográficas, contribuindo para o entendimento dos impactos das atividades humanas sobre o ciclo hidrológico e para o desenvolvimento de estratégias de gestão sustentável dos recursos hídricos.
- 8 January 2025
- Published by Revista de Ciencia e Inovacao in Revista de Ciência e Inovação
- Vol. 11 (1) , 1-25
Open AccessEstudo comparativo e espacialização do parâmetro CN (curve number) na bacia hidrográfica do rio do Turvo, Rio Grande do Sul, entre os anos de 1990, 2006 e 2022
Este estudo investigou o uso da metodologia Curve Number (CN) para avaliar o escoamento superficial na bacia hidrográfica do rio do Turvo, no Rio Grande do Sul, Brasil, nos anos de 1990, 2006 e 2022. Utilizando dados de uso e cobertura do solo e informações pedológicas, foram correlacionados os padrões de uso da terra com as características hidrológicas dos solos, gerando mapas que representam a distribuição espacial do CN nos períodos analisados. Os resultados evidenciaram transformações no uso da terra, destacando-se o aumento das áreas urbanas em cerca de 260% no período e 50% no cultivo de soja. Consequentemente, houve um avanço progressivo no valor de CN ao longo dos anos, indicando o aumento do escoamento superficial, influenciado principalmente pelo tipo de cobertura do solo. Os resultados obtidos evidenciam a urgência de ações de conservação do solo e da vegetação nativa na região. O estudo demonstra a importância da metodologia CN para a avaliação dos processos hidrológicos em bacias hidrográficas, contribuindo para o entendimento dos impactos das atividades humanas sobre o ciclo hidrológico e para o desenvolvimento de estratégias de gestão sustentável dos recursos hídricos.
- Open Access
- 20 April 2024
- Published by Editoriales Iberoamericanos in Natural Resources
- Vol. 14 (1) , 1-11
Análise bibliométrica do estudo da variável evapotranspiração em sistemas de wetlands construídos
Este estudo realiza uma análise bibliométrica abordando a variável Evapotranspiração (ET) em sistemas de Wetlands Construídos (WC). Foram analisados 145 artigos das bases de dados Scopus e Science Direct, abrangendo o período de 2013 a 2023. O objetivo foi avaliar a presença de estudos sobre ET nesses sistemas. Utilizou-se o programa VOSviewer para a análise bibliométrica. Os resultados revelaram uma escassez de estudos dedicados à ET, apesar de sua importância no balanço hídrico e na eficiência dos sistemas. Observou-se um aumento no número de publicações recentes, indicando um crescente interesse científico nesta área. No entanto, a precisão na medição da ET ainda é uma questão desafiadora, o que pode afetar a eficácia dos sistemas de tratamento. Conclui-se que a evapotranspiração continua sendo subestimada por muitos pesquisadores, apesar de sua relevância. Espera-se que este estudo estimule uma maior atenção e investigação sobre a ET em futuras pesquisas, visando aprimorar a eficiência dos sistemas de Wetlands Construídos no tratamento de efluentes.
- 20 April 2024
- Published by Editoriales Iberoamericanos in Natural Resources
- Vol. 14 (1) , 1-11
Open AccessAnálise bibliométrica do estudo da variável evapotranspiração em sistemas de wetlands construídos
Este estudo realiza uma análise bibliométrica abordando a variável Evapotranspiração (ET) em sistemas de Wetlands Construídos (WC). Foram analisados 145 artigos das bases de dados Scopus e Science Direct, abrangendo o período de 2013 a 2023. O objetivo foi avaliar a presença de estudos sobre ET nesses sistemas. Utilizou-se o programa VOSviewer para a análise bibliométrica. Os resultados revelaram uma escassez de estudos dedicados à ET, apesar de sua importância no balanço hídrico e na eficiência dos sistemas. Observou-se um aumento no número de publicações recentes, indicando um crescente interesse científico nesta área. No entanto, a precisão na medição da ET ainda é uma questão desafiadora, o que pode afetar a eficácia dos sistemas de tratamento. Conclui-se que a evapotranspiração continua sendo subestimada por muitos pesquisadores, apesar de sua relevância. Espera-se que este estudo estimule uma maior atenção e investigação sobre a ET em futuras pesquisas, visando aprimorar a eficiência dos sistemas de Wetlands Construídos no tratamento de efluentes.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 96 (4) , e20240275
Removal of antibiotics in constructed wetlands: a review and bibliometric analysis
This study offers a comprehensive systematic review on the removal of antibiotics in Constructed Wetlands (CWs), evaluating their efficacy as an alternative to conventional wastewater treatment methods. Data from 82 articles were analyzed, focusing on removal rates, antibiotic types, and system configurations, including scale, vegetation, sediment, flow, hydraulic retention time (HRT), and hydraulic loading rate (HLR). The findings indicate that full-scale CWs, particularly those utilizing vegetation like Cyperus alternifolius L. and materials such as shells, zeolites, medicinal stone, and ceramics, achieved removal rates exceeding 90% for various antibiotics. The study underscores the importance of optimizing both anaerobic and aerobic conditions to enhance removal efficiency, noting that aerobic environments promote oxidative processes effective for β-lactams, while anaerobic environments facilitate reduction processes beneficial for sulfonamides. Hybrid systems combining these zones demonstrated maximal removal efficiency. This review advances the understanding of antibiotic removal in CWs, presenting them as a viable, sustainable solution to mitigate environmental impacts, preserve water quality, and protect public health. Further research is recommended to explore the impact of root types and bed configurations on removal efficiency.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 96 (4) , e20240275
Open AccessRemoval of antibiotics in constructed wetlands: a review and bibliometric analysis
This study offers a comprehensive systematic review on the removal of antibiotics in Constructed Wetlands (CWs), evaluating their efficacy as an alternative to conventional wastewater treatment methods. Data from 82 articles were analyzed, focusing on removal rates, antibiotic types, and system configurations, including scale, vegetation, sediment, flow, hydraulic retention time (HRT), and hydraulic loading rate (HLR). The findings indicate that full-scale CWs, particularly those utilizing vegetation like Cyperus alternifolius L. and materials such as shells, zeolites, medicinal stone, and ceramics, achieved removal rates exceeding 90% for various antibiotics. The study underscores the importance of optimizing both anaerobic and aerobic conditions to enhance removal efficiency, noting that aerobic environments promote oxidative processes effective for β-lactams, while anaerobic environments facilitate reduction processes beneficial for sulfonamides. Hybrid systems combining these zones demonstrated maximal removal efficiency. This review advances the understanding of antibiotic removal in CWs, presenting them as a viable, sustainable solution to mitigate environmental impacts, preserve water quality, and protect public health. Further research is recommended to explore the impact of root types and bed configurations on removal efficiency.
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 28, e20220252
Análise da influência da taxa de aplicação hidráulica e alturas de saturação em wetland construído de fluxo vertical na remoção de nitrogênio de esgoto doméstico
O objetivo deste artigo foi avaliar a influência da saturação de fundo para duas condições: 15 e 25 cm, em sistemas de wetlands construídos de fluxo vertical (WCFV) com leito de 75 cm, utilizando diferentes taxas de aplicação hidráulica (TAH): 40, 70 e 100 mm d-1. Avaliaram-se eficiências de remoção de demanda química de oxigênio (DQO), sólidos suspensos totais (SST), sólidos totais (ST), nitrogênio amoniacal (N-NH4+), nitrogênio total Kjeldahl) NTK e nitrogênio total (NT). Para DQO, 15 cm de saturação obtiveram eficiência de 85% e colunas com 25 cm, 86%, sem diferença significativa entre as alturas de saturação e TAH estudadas. Para N-NH4+, 15 cm apontaram eficiência de 74% e as de 25 cm, 68%, com diferença estatística significativa entre os níveis de saturação para todas as TAH testadas. Para NT, 15 cm resultaram em 71% e com 25 cm 74% de eficiência, com diferença significativa entre as TAH para a altura de 25 cm. Ainda, para SST, foram obtidas eficiências de 91 e 63% para 15 e 25 cm, respectivamente, com diferença significativa entre os níveis de saturação para as TAH de 40 e 100 mm d-1. Os resultados mostraram que, em média, a saturação de 25 cm foi mais eficiente na remoção de NT. Com relação à TAH, a mais eficiente mostrou-se a intermediária testada, pois, apesar de nem sempre ter apresentado as maiores remoções perante a área utilizada, foi a melhor. A saturação possibilitou bom desempenho de remoção de NT e matéria orgânica carbonácea referente à DQO, demonstrando que essa modificação em um wetland construído pode melhorar o tratamento de efluentes domésticos.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 28, e20220252
Open AccessAnálise da influência da taxa de aplicação hidráulica e alturas de saturação em wetland construído de fluxo vertical na remoção de nitrogênio de esgoto doméstico
O objetivo deste artigo foi avaliar a influência da saturação de fundo para duas condições: 15 e 25 cm, em sistemas de wetlands construídos de fluxo vertical (WCFV) com leito de 75 cm, utilizando diferentes taxas de aplicação hidráulica (TAH): 40, 70 e 100 mm d-1. Avaliaram-se eficiências de remoção de demanda química de oxigênio (DQO), sólidos suspensos totais (SST), sólidos totais (ST), nitrogênio amoniacal (N-NH4+), nitrogênio total Kjeldahl) NTK e nitrogênio total (NT). Para DQO, 15 cm de saturação obtiveram eficiência de 85% e colunas com 25 cm, 86%, sem diferença significativa entre as alturas de saturação e TAH estudadas. Para N-NH4+, 15 cm apontaram eficiência de 74% e as de 25 cm, 68%, com diferença estatística significativa entre os níveis de saturação para todas as TAH testadas. Para NT, 15 cm resultaram em 71% e com 25 cm 74% de eficiência, com diferença significativa entre as TAH para a altura de 25 cm. Ainda, para SST, foram obtidas eficiências de 91 e 63% para 15 e 25 cm, respectivamente, com diferença significativa entre os níveis de saturação para as TAH de 40 e 100 mm d-1. Os resultados mostraram que, em média, a saturação de 25 cm foi mais eficiente na remoção de NT. Com relação à TAH, a mais eficiente mostrou-se a intermediária testada, pois, apesar de nem sempre ter apresentado as maiores remoções perante a área utilizada, foi a melhor. A saturação possibilitou bom desempenho de remoção de NT e matéria orgânica carbonácea referente à DQO, demonstrando que essa modificação em um wetland construído pode melhorar o tratamento de efluentes domésticos.
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 28, e20220025
Degradation of pharmaceuticals in sanitary effluent by the combination of oxidation and photo-oxidation processes
Most conventional sewage treatment systems are not able to fully remove micropollutants found in sewage. Thus, the simultaneous degradation of 11 pharmaceuticals identified in the effluent of a sewage treatment plant in Southern Brazil was herein investigated through advanced oxidation processes based on ozonation, ultraviolet radiation and hydrogen peroxide. For detection, samples were prepared through solid-phase extraction and pharmaceuticals were identified through ultra-high performance liquid chromatography tandem mass spectrometry. Active ingredients such as ciprofloxacin, oxytetracycline, paracetamol, sulfamethoxazole and trimethoprim had their concentrations increased for degradation analysis purposes. Trials were carried out on a bench at room temperature and neutral pH, with aliquots collected at 7.5 and 15 minutes. Two ozone doses (0.5 and 0.9 mg per mg of dissolved organic carbon), and combinations of the lowest ozone dose with photolysis (254 nm) and with 25 mg.L−1 of hydrogen peroxide were evaluated. Pharmaceuticals mineralization efficiency was assessed in a total organic carbon analyzer. The process combining ozone, hydrogen peroxide and ultraviolet radiation was the most efficient in the degradation of all pharmaceuticals detected in this study, since it enabled reducing oxytetracycline by 89.32%, caffeine by 96.79%, trimethoprim by 97.40%, ciprofloxacin by 97.75%, sulfamethoxazole by 99.79%, paracetamol by 99.96%, and clindamycin, ofloxacin, sulfadiazine, sulfathiazole and tylosin by 100%. This process also recorded the highest mineralization rate (60.52%), fact that confirmed the potential to decrease persistent pharmaceuticals found in conventional sewage treatment systems.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 28, e20220025
Open AccessDegradation of pharmaceuticals in sanitary effluent by the combination of oxidation and photo-oxidation processes
Most conventional sewage treatment systems are not able to fully remove micropollutants found in sewage. Thus, the simultaneous degradation of 11 pharmaceuticals identified in the effluent of a sewage treatment plant in Southern Brazil was herein investigated through advanced oxidation processes based on ozonation, ultraviolet radiation and hydrogen peroxide. For detection, samples were prepared through solid-phase extraction and pharmaceuticals were identified through ultra-high performance liquid chromatography tandem mass spectrometry. Active ingredients such as ciprofloxacin, oxytetracycline, paracetamol, sulfamethoxazole and trimethoprim had their concentrations increased for degradation analysis purposes. Trials were carried out on a bench at room temperature and neutral pH, with aliquots collected at 7.5 and 15 minutes. Two ozone doses (0.5 and 0.9 mg per mg of dissolved organic carbon), and combinations of the lowest ozone dose with photolysis (254 nm) and with 25 mg.L−1 of hydrogen peroxide were evaluated. Pharmaceuticals mineralization efficiency was assessed in a total organic carbon analyzer. The process combining ozone, hydrogen peroxide and ultraviolet radiation was the most efficient in the degradation of all pharmaceuticals detected in this study, since it enabled reducing oxytetracycline by 89.32%, caffeine by 96.79%, trimethoprim by 97.40%, ciprofloxacin by 97.75%, sulfamethoxazole by 99.79%, paracetamol by 99.96%, and clindamycin, ofloxacin, sulfadiazine, sulfathiazole and tylosin by 100%. This process also recorded the highest mineralization rate (60.52%), fact that confirmed the potential to decrease persistent pharmaceuticals found in conventional sewage treatment systems.
- Open Access
- 1 February 2022
- Published by Lepidus Tecnologia in Brazilian Journal of Science
- Vol. 1 (2) , 8-20
Contaminação de efluentes por amoxicilina: consequências ambientais e métodos de remoção
A intensificação na poluição gerada pelas atividades humanas por décadas, lançando efluentes, in natura ou parcialmente tratados nos corpos hídricos receptores, causando sérios danos ao meio ambiente. Dentre estes efluentes, os fármacos acabam trazendo uma grande preocupação, uma vez que, podem ser resistentes inclusive aos processos convencionais de tratamento, o que acaba alertando para a problemática da falta de tratamento adequado. Objetivou-se com este trabalho, realizar uma análise dos métodos de tratamento de efluentes utilizados para remoção e degradação do antibiótico do grupo β-lactâmicos, amoxicilina. Foi realizado um levantamento bibliográfico envolta de trinta e oito artigos, com uma filtragem e seleção, resultando em apenas doze trabalhos que se enquadraram nos pré-requisitos estabelecidos. Grande parte dos estudos selecionados desenvolveu suas análises em efluentes contaminados artificialmente, utilizando técnicas de adsorção, processos oxidativos avançados (POAs), wetlands, biorreator com membranas submersas, filtro de carvão ativado e hidrólise. É importante ressaltar que cada estudo, operou com técnicas bastante particulares, sendo este o principal motivo dos diferentes resultados encontrados em métodos bastante semelhantes. A análise demonstrou que dentre os métodos observados, apenas o processo tradicional de oxidação com reagente Fenton, e o método de remoção por Hidrólise Alcalina, com pH de 12,5 em 60 minutos atingiram a excelência de 100% da remoção do antibiótico. No outro extremo observou-se que a técnica de remoção do antibiótico por meio de wetlands construídos, atingiu a remoção mínima de 15% e o POA com fotólise natural em tempo de 360 minutos com remoção de 24%. Os números encontrados apontam a importância de combinar os métodos de tratamento de esgoto para alcançar uma maior pureza do efluente que será lançado no ambiente.
- 1 February 2022
- Published by Lepidus Tecnologia in Brazilian Journal of Science
- Vol. 1 (2) , 8-20
Open AccessContaminação de efluentes por amoxicilina: consequências ambientais e métodos de remoção
A intensificação na poluição gerada pelas atividades humanas por décadas, lançando efluentes, in natura ou parcialmente tratados nos corpos hídricos receptores, causando sérios danos ao meio ambiente. Dentre estes efluentes, os fármacos acabam trazendo uma grande preocupação, uma vez que, podem ser resistentes inclusive aos processos convencionais de tratamento, o que acaba alertando para a problemática da falta de tratamento adequado. Objetivou-se com este trabalho, realizar uma análise dos métodos de tratamento de efluentes utilizados para remoção e degradação do antibiótico do grupo β-lactâmicos, amoxicilina. Foi realizado um levantamento bibliográfico envolta de trinta e oito artigos, com uma filtragem e seleção, resultando em apenas doze trabalhos que se enquadraram nos pré-requisitos estabelecidos. Grande parte dos estudos selecionados desenvolveu suas análises em efluentes contaminados artificialmente, utilizando técnicas de adsorção, processos oxidativos avançados (POAs), wetlands, biorreator com membranas submersas, filtro de carvão ativado e hidrólise. É importante ressaltar que cada estudo, operou com técnicas bastante particulares, sendo este o principal motivo dos diferentes resultados encontrados em métodos bastante semelhantes. A análise demonstrou que dentre os métodos observados, apenas o processo tradicional de oxidação com reagente Fenton, e o método de remoção por Hidrólise Alcalina, com pH de 12,5 em 60 minutos atingiram a excelência de 100% da remoção do antibiótico. No outro extremo observou-se que a técnica de remoção do antibiótico por meio de wetlands construídos, atingiu a remoção mínima de 15% e o POA com fotólise natural em tempo de 360 minutos com remoção de 24%. Os números encontrados apontam a importância de combinar os métodos de tratamento de esgoto para alcançar uma maior pureza do efluente que será lançado no ambiente.
- Open Access
- 1 August 2021
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 26 (4) , 721-730
Potencial de nitrificação/desnitrificação de tanque séptico e wetland construído com recirculação no tratamento descentralizado de esgoto de empreendimento habitacional
RESUMO Os wetlands construídos (WC) são uma ecotecnologia aplicável para o tratamento descentralizado de esgotos notadamente em pequenas comunidades, em razão de sua simplicidade operacional. Existem vários arranjos e combinações de WC possíveis, destacando-se o arranjo tanque séptico (TS), seguido da modalidade de WC de escoamento vertical (WCV) com recirculação do efluente do WCV de volta para o TS, como proposta para possibilitar a remoção de nitrogênio presente no esgoto afluente. Entretanto, no Brasil, essa configuração e suas implicações operacionais e de desempenho são pouco exploradas. Diante disso, o objetivo deste trabalho foi avaliar o desempenho de um sistema de TS seguido de um WCV com recirculação no tratamento descentralizado de esgoto doméstico. O sistema empregado no tratamento de esgoto de um equivalente populacional de dez habitantes é composto de um TS (4,7 m3 de volume útil), seguido de um WCV (24,5 m2 de área superficial) preenchido com brita e plantado com Canna spp. O monitoramento, que compreendeu um período de nove meses, teve início após um ano e cinco meses de operação do sistema. Utilizando taxa de 50% de recirculação, taxa de aplicação hidráulica no WCV de 85 mm d-1 e carga de 47 g DQO m-2.d-1, foram obtidas boas eficiências para remoção conjunta de demanda química de oxigênio — DQO (80%), sólidos em suspensão totais — SST (85%) e nitrogênio total —NT (42%), mesmo com elevadas cargas orgânicas. Além das boas eficiências apresentadas, o sistema demonstrou ser robusto e de operação simples e representa uma alternativa tecnológica com potencial para o tratamento descentralizado de esgotos de empreendimentos habitacionais.
- 1 August 2021
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 26 (4) , 721-730
Open AccessPotencial de nitrificação/desnitrificação de tanque séptico e wetland construído com recirculação no tratamento descentralizado de esgoto de empreendimento habitacional
RESUMO Os wetlands construídos (WC) são uma ecotecnologia aplicável para o tratamento descentralizado de esgotos notadamente em pequenas comunidades, em razão de sua simplicidade operacional. Existem vários arranjos e combinações de WC possíveis, destacando-se o arranjo tanque séptico (TS), seguido da modalidade de WC de escoamento vertical (WCV) com recirculação do efluente do WCV de volta para o TS, como proposta para possibilitar a remoção de nitrogênio presente no esgoto afluente. Entretanto, no Brasil, essa configuração e suas implicações operacionais e de desempenho são pouco exploradas. Diante disso, o objetivo deste trabalho foi avaliar o desempenho de um sistema de TS seguido de um WCV com recirculação no tratamento descentralizado de esgoto doméstico. O sistema empregado no tratamento de esgoto de um equivalente populacional de dez habitantes é composto de um TS (4,7 m3 de volume útil), seguido de um WCV (24,5 m2 de área superficial) preenchido com brita e plantado com Canna spp. O monitoramento, que compreendeu um período de nove meses, teve início após um ano e cinco meses de operação do sistema. Utilizando taxa de 50% de recirculação, taxa de aplicação hidráulica no WCV de 85 mm d-1 e carga de 47 g DQO m-2.d-1, foram obtidas boas eficiências para remoção conjunta de demanda química de oxigênio — DQO (80%), sólidos em suspensão totais — SST (85%) e nitrogênio total —NT (42%), mesmo com elevadas cargas orgânicas. Além das boas eficiências apresentadas, o sistema demonstrou ser robusto e de operação simples e representa uma alternativa tecnológica com potencial para o tratamento descentralizado de esgotos de empreendimentos habitacionais.
- Open Access
- 1 May 2021
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 214, 112049
Ecotoxicological responses of Eisenia andrei exposed in field-contaminated soils by sanitary sewage
- 1 May 2021
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 214, 112049
Open AccessEcotoxicological responses of Eisenia andrei exposed in field-contaminated soils by sanitary sewage
- 16 February 2021
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 28 (24) , 30955-30974
Pharmaceutical compound removal efficiency by a small constructed wetland located in south Brazil
The fate of pharmaceuticals during the treatment of effluents is of major concern since they are not completely degraded and because of their persistence and mobility in environment. Indeed, even at low concentrations, they represent a risk to aquatic life and human health. In this work, fourteen pharmaceuticals were monitored in a constructed wetland wastewater treatment plants (WWTP) assessed in both influent and effluent samples. The basic water quality parameters were evaluated, and the removal efficiency of pharmaceutical, potential for bioaccumulation, and the impact of WWTP were assessed using Polar Organic Chemical Integrative Sampler (POCIS) and biofilms. The pharmaceutical compounds were quantified by High Performance Liquid chromatography coupled to mass spectrometry. The sampling campaign was carried out during winter (July/2018) and summer (January/2019). The WWTP performed well regarding the removal of TSS, COD, and BOD5 and succeeded to eliminate a significant part of the organic and inorganic pollution present in domestic wastewater but has low efficiency regarding the removal of pharmaceutical compounds. Biofilms were shown to interact with pharmaceuticals and were reported to play a role in their capture from water. The antibiotics were reported to display a high risk for aquatic organisms.
- 16 February 2021
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 28 (24) , 30955-30974
Pharmaceutical compound removal efficiency by a small constructed wetland located in south Brazil
The fate of pharmaceuticals during the treatment of effluents is of major concern since they are not completely degraded and because of their persistence and mobility in environment. Indeed, even at low concentrations, they represent a risk to aquatic life and human health. In this work, fourteen pharmaceuticals were monitored in a constructed wetland wastewater treatment plants (WWTP) assessed in both influent and effluent samples. The basic water quality parameters were evaluated, and the removal efficiency of pharmaceutical, potential for bioaccumulation, and the impact of WWTP were assessed using Polar Organic Chemical Integrative Sampler (POCIS) and biofilms. The pharmaceutical compounds were quantified by High Performance Liquid chromatography coupled to mass spectrometry. The sampling campaign was carried out during winter (July/2018) and summer (January/2019). The WWTP performed well regarding the removal of TSS, COD, and BOD5 and succeeded to eliminate a significant part of the organic and inorganic pollution present in domestic wastewater but has low efficiency regarding the removal of pharmaceutical compounds. Biofilms were shown to interact with pharmaceuticals and were reported to play a role in their capture from water. The antibiotics were reported to display a high risk for aquatic organisms.
- Open Access
- 1 February 2021
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 26 (1) , 113-121
Eletrocoagulação como pós-tratamento do efluente de um wetland construído de escoamento vertical
RESUMO A eletrocoagulação (EC) foi aplicada como tratamento terciário para o efluente de wetland construído de escoamento vertical (WCV). O sistema de EC compreendeu um reator cilíndrico de vidro (1 L) e eletrodos de alumínio conectados a uma fonte de alimentação de corrente contínua. O estudo foi desenvolvido em duas etapas. Na primeira, as condições operacionais do reator foram delimitadas por meio de um experimento bifatorial 32 (3×3) de natureza quantitativa × quantitativa, analisando intensidade de corrente e tempo. Com base nos resultados obtidos, a regressão linear resultou na combinação de 1,3 A e 18 min, com custo operacional elétrico de 2,71 R$.m−3. Em seguida, realizou-se a etapa de monitoramento durante quatro meses, aplicando a EC sob essas condições fixas estabelecidas. As eficiências médias de remoção alcançadas foram de 99,7% para P-PO43-, 20,6% para N-NO3−, 2,37 log de coliformes totais, 2,35 log de Escherichia coli, 84,9% para demanda química de oxigênio, 95% para turbidez, 95,1% para cor aparente, aumento de 19% no pH, de 18,6% na temperatura e diminuição de 15,8% na condutividade elétrica. O tratamento demonstrou elevadas e homogêneas eficiências de remoção dos poluentes, principalmente para P-PO43-, indicando que a EC produz efluente com menor potencial poluidor e é indicada para tratamento de efluente doméstico em nível terciário.
- 1 February 2021
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 26 (1) , 113-121
Open AccessEletrocoagulação como pós-tratamento do efluente de um wetland construído de escoamento vertical
RESUMO A eletrocoagulação (EC) foi aplicada como tratamento terciário para o efluente de wetland construído de escoamento vertical (WCV). O sistema de EC compreendeu um reator cilíndrico de vidro (1 L) e eletrodos de alumínio conectados a uma fonte de alimentação de corrente contínua. O estudo foi desenvolvido em duas etapas. Na primeira, as condições operacionais do reator foram delimitadas por meio de um experimento bifatorial 32 (3×3) de natureza quantitativa × quantitativa, analisando intensidade de corrente e tempo. Com base nos resultados obtidos, a regressão linear resultou na combinação de 1,3 A e 18 min, com custo operacional elétrico de 2,71 R$.m−3. Em seguida, realizou-se a etapa de monitoramento durante quatro meses, aplicando a EC sob essas condições fixas estabelecidas. As eficiências médias de remoção alcançadas foram de 99,7% para P-PO43-, 20,6% para N-NO3−, 2,37 log de coliformes totais, 2,35 log de Escherichia coli, 84,9% para demanda química de oxigênio, 95% para turbidez, 95,1% para cor aparente, aumento de 19% no pH, de 18,6% na temperatura e diminuição de 15,8% na condutividade elétrica. O tratamento demonstrou elevadas e homogêneas eficiências de remoção dos poluentes, principalmente para P-PO43-, indicando que a EC produz efluente com menor potencial poluidor e é indicada para tratamento de efluente doméstico em nível terciário.