CCClarissa Zimmerman Cooley

Clarissa Zimmerman Cooley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Clarissa Zimmerman Cooley has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Lawrence L. Wald

    Harvard Medical School Boston Massachusetts USA

    7 shared publications
  • Jason P. Stockmann

    Department of Radiology, Massachusetts General Hospital, Boston, MA, USA; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, USA

    6 shared publications
  • Stephen F. Cauley

    Harvard Medical School Boston Massachusetts USA

    3 shared publications
  • Azma Mareyam

    A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA

    2 shared publications
  • Bastien Guerin

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA

    2 shared publications
  • Charlotte R. Sappo

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA

    2 shared publications

Latest Publications

  • External Dynamic InTerference Estimation and Removal (EDITER) for low field MRI

    by Sai Abitha Srinivas, Stephen F. Cauley, Jason P. Stockmann, Charlotte R. Sappo, Christopher E. Vaughn, Lawrence L. Wald, William A. Grissom, Clarissa Z. Cooley

    Purpose: Point‐of‐care MRI requires operation outside of Faraday shielded rooms normally used to block image‐degrading electromagnetic interference (EMI). To address this, we introduce the EDITER method (External Dynamic InTerference Estimation and Removal), an external sensor‐based method to retrospectively remove image artifacts from time‐varying external interference sources.Theory and Methods: The method acquires data from multiple EMI detectors (tuned receive coils as well as untuned electrodes placed on the body) simultaneously with the primary MR coil during and between image data acquisition. We calculate impulse response functions dynamically that map the data from the detectors to the time varying artifacts then remove the transformed detected EMI from the MR data. Performance of the EDITER algorithm was assessed in phantom and in vivo imaging experiments in an 80 mT portable brain MRI in a controlled EMI environment and with an open 47.5 mT MRI scanner in an uncontrolled EMI setting.Results: In the controlled setting, the effectiveness of the EDITER technique was demonstrated for specific types of introduced EMI sources with up to a 97% reduction of structured EMI and up to 76% reduction of broadband EMI in phantom experiments. In the uncontrolled EMI experiments, we demonstrate EMI reductions of up to 99% using an electrode and pick‐up coil in vivo. We demonstrate up to a nine‐fold improvement in image SNR with the method.Conclusion: The EDITER technique is a flexible and robust method to improve image quality in portable MRI systems with minimal passive shielding and could reduce the reliance of MRI on shielded rooms and allow for truly portable MRI.


  • Low-field portable brain MRI in CNS demyelinating disease

    by Farrah J. Mateen, Clarissa Zimmerman Cooley, Jason P. Stockmann, Dylan R. Rice, Andre C. Vogel, Lawrence L. Wald


  • Open Access

    External Dynamic InTerference Estimation and Removal (EDITER) for low field MRI

    by Sai Abitha Srinivas, Stephen F Cauley, Jason P Stockmann, Charlotte R Sappo, Christopher E Vaughn, Lawrence L Wald, William A Grissom, Clarissa Z Cooley

    Purpose: Point-of-care MRI requires operation outside of a faraday shielded room normally used to block image-degrading electromagnetic Interference (EMI). To address this, we introduce the EDITER method, an external sensor based dynamic EMI estimation and removal method to retrospectively remove time-varying external interference sources. Theory and Methods: The method acquires data from multiple EMI detectors (tuned receive coils and electrodes placed on the body) simultaneous with the primary MR coil during image data acquisition. We dynamically calculate impulse response functions that map the data from the detectors to the artifacts in the kspace data, then remove the transformed detected EMI from the MR data. Performance of the EDITER algorithm was assessed in phantom and in vivo imaging experiments in an 80mT portable brain MRI in a controlled EMI environment and with an open 47.5mT MRI scanner in an uncontrolled EMI setting. Results: In the controlled setting, the effectiveness of the EDITER technique was demonstrated for specific types of introduced EMI sources with up to a 97% reduction of structured EMI and up to 76% reduction of broadband EMI. In the uncontrolled EMI experiments, we demonstrate EMI reductions of 37% with a single pickup coil and 89% with a single electrode and up to 99% with both. Conclusion: The EDITER technique is a flexible and robust method to improve image quality in portable MRI systems with minimal passive shielding. This could reduce the reliance of MRI on shielded rooms and allow for truly portable MRI with specialized compact POC scanners

  • Top Cited Papers

    A portable scanner for magnetic resonance imaging of the brain

    by Clarissa Z. Cooley, Patrick C. McDaniel, Jason P. Stockmann, Sai Abitha Srinivas, Stephen F. Cauley, Monika Śliwiak, Charlotte R. Sappo, Christopher F. Vaughn, Bastien Guerin, Matthew S. Rosen, et al.

    Access to scanners for magnetic resonance imaging (MRI) is typically limited by cost and by infrastructure requirements. Here, we report the design and testing of a portable prototype scanner for brain MRI that uses a compact and lightweight permanent rare-earth magnet with a built-in readout field gradient. The 122-kg low-field (80 mT) magnet has a Halbach cylinder design that results in a minimal stray field and requires neither cryogenics nor external power. The built-in magnetic field gradient reduces the reliance on high-power gradient drivers, lowering the overall requirements for power and cooling, and reducing acoustic noise. Imperfections in the encoding fields are mitigated with a generalized iterative image reconstruction technique that leverages previous characterization of the field patterns. In healthy adult volunteers, the scanner can generate T1-weighted, T2-weighted and proton density-weighted brain images with a spatial resolution of 2.2 × 1.3 × 6.8 mm3. Future versions of the scanner could improve the accessibility of brain MRI at the point of care, particularly for critically ill patients.


  • Corrigendum to “Design and implementation of a low-cost, tabletop MRI scanner for education and research prototyping” [J. Magn. Reson. 310 (2020) 106625]

    by Clarissa Zimmerman Cooley, Jason P. Stockmann, Thomas Witzel, Cris LaPierre, Azma Mareyam, Feng Jia, Maxim Zaitsev, Wenhui Yang, Wang Zheng, Pascal Stang, et al.

  • Open Access

    A Portable Brain MRI Scanner for Underserved Settings and Point-Of-Care Imaging

    by Clarissa Z. Cooley, Patrick C. McDaniel, Jason P. Stockmann, Sai Abitha Srinivas, Stephen Cauley, Monika Sliwiak, Charlotte R. Sappo, Christopher F. Vaughn, Bastien Guerin, Matthew S. Rosen, et al.

    Access to and availability of MRI scanners is typically limited by their cost, siting and infrastructure requirements. This precludes MRI diagnostics, the reference standard for neurological assessment, in patients who cannot be transported to specialized scanner suites. This includes patients who are critically ill and unstable, and patients located in low-resource settings. The scanner design presented here aims to extend the reach of MRI by substantially reducing these limitations. Our goal is to shift the cost-benefit calculation for MRI toward more frequent and varied use, including improved accessibility worldwide and point of care operation. Here, we describe a portable brain MRI scanner using a compact, lightweight permanent magnet, with a built-in readout field gradient. Our low-field (80 mT) Halbach cylinder design of rare-earth permanent magnets results in a 122 kg magnet with minimal stray-field, requiring neither cryogenics nor external power. The built-in magnetic field gradient reduces reliance on high-power gradient drivers, which not only lowers overall system power and cooling requirements, but also reduces acoustic noise. Imperfections in the encoding fields are mitigated with a generalized iterative image reconstruction technique, that uses prior characterization of the field patterns. Our system was validated using T1, T2 and proton density weighted in vivo brain images with a spatial resolution of 2.2 x 1.3 x 6.8 mm$^3$.

  • Design and implementation of a low-cost, tabletop MRI scanner for education and research prototyping

    by Clarissa Zimmerman Cooley, Jason P. Stockmann, Thomas Witzel, Cris LaPierre, Azma Mareyam, Feng Jia, Maxim Zaitsev, Yang Wenhui, Wang Zheng, Pascal Stang, et al.


  • Rodent Cerebral Blood Volume (CBV) changes during hypercapnia observed using Magnetic Particle Imaging (MPI) detection

    by Clarissa Zimmerman Cooley, Joseph B. Mandeville, Erica E. Mason, Emiri T. Mandeville, Lawrence L. Wald


  • Design of Sparse Halbach Magnet Arrays for Portable MRI Using a Genetic Algorithm

    by Clarissa Zimmerman Cooley, Melissa W. Haskell, Stephen F. Cauley, Charlotte Sappo, Cristen D. Lapierre, Christopher G. Ha, Jason P. Stockmann, Lawrence L. Wald

    Permanent magnet arrays offer several attributes attractive for the development of a low-cost portable MRI scanner for brain imaging. They offer the potential for a relatively lightweight, low to mid-field system with no cryogenics, a small fringe field, and no electrical power requirements or heat dissipation needs. The cylindrical Halbach array, however, requires external shimming or mechanical adjustments to produce B 0 fields with standard MRI homogeneity levels (e.g., 0.1 ppm over field of view), particularly when constrained or truncated geometries are needed, such as a head-only magnet where the magnet length is constrained by the shoulders. For portable scanners using rotation of the magnet for spatial encoding with generalized projections, the spatial pattern of the field is important since it acts as the encoding field. In either a static or rotating magnet, it will be important to be able to optimize the field pattern of cylindrical Halbach arrays in a way that retains construction simplicity. To achieve this, we present a method for designing an optimized cylindrical Halbach magnet using the genetic algorithm (GA) to achieve either homogeneity (for standard MRI applications) or a favorable spatial encoding field pattern (for rotational spatial encoding applications). We compare the chosen designs against a standard, fully populated sparse Halbach design, and evaluate optimized spatial encoding fields using point-spread-function and image simulations. We validate the calculations by comparing to the measured field of a constructed magnet. The experimentally implemented design produced fields in good agreement with the predicted fields, and the GA was successful in improving the chosen metrics. For the uniform target field, an order of magnitude homogeneity improvement was achieved compared to the un-optimized, fully populated design. For the rotational encoding design, the resolution uniformity is improved by 95% compared to a uniformly populated design.