Nuno R. Martins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nuno R. Martins has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Guilherme Carrilho da Graça
University of Lisbon, Lisbon, Portugal
8 shared publications Guilherme Carrilho da Graça
4 shared publications- Peter J. Bourne-Webb
CERIS, Instituto Superior Técnico
2 shared publications - Ana F. Silva1 shared publication
Cristina S. Horta
1 shared publicationHugo M. Nunes
1 shared publication
Latest Publications
- Open Access
- 25 July 2025
- Published by Elsevier in Building and Environment
- Vol. 284
Full-scale performance of a low-pressure loss PM2.5 air filter for building natural ventilation
- 25 July 2025
- Published by Elsevier in Building and Environment
- Vol. 284
Open AccessFull-scale performance of a low-pressure loss PM2.5 air filter for building natural ventilation
- Open Access
- 17 November 2024
- Published by Elsevier in Energy and Buildings
- Vol. 326
Assessment of cooling capacity of chimney-enhanced cross-ventilation systems for kindergartens in African cities
- 17 November 2024
- Published by Elsevier in Energy and Buildings
- Vol. 326
Open AccessAssessment of cooling capacity of chimney-enhanced cross-ventilation systems for kindergartens in African cities
- Open Access
- 27 September 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 79
Health effects of PM2.5 emissions from woodstoves and fireplaces in living spaces
- 27 September 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 79
Open AccessHealth effects of PM2.5 emissions from woodstoves and fireplaces in living spaces
- 25 November 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 64
An assessment of the potential effect of climate change on renewable hybrid heating and cooling systems
- 25 November 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 64
An assessment of the potential effect of climate change on renewable hybrid heating and cooling systems
- Open Access
- 27 September 2021
- Published by EDP Sciences in Renewable Energy and Environmental Sustainability
- Vol. 6, 33
Hybridization of Heat Pump Systems With Natural Ventilation To Improve Energy Efficiency in Cooling Dominated Buildings
Building foundation piles can be used as heat exchangers in ground-source heat pump (GSHP) systems to provide highly efficient renewable heating and cooling (H&C). Unbalanced H&C loads lead to heat build-up in the ground, decreasing the system's overall performance. In this study, the introduction of natural ventilation (NV) has been examined to decrease cooling load imbalance in cooling-dominated buildings to improve system efficiency. Building energy simulations estimated the H&C loads for an office building in three Portuguese cities: Lisbon, Porto and Faro, yielding heating loads of 0.2–3.6 MWh/year and cooling loads of 260–450 MWh/year. Four renewable H&C technology scenarios were used to assess energy performance: (1) an air-source heat pump (ASHP) system; (2) a GSHP system utilizing energy piles; (3) hybrid ASHP-NV and (4) hybrid GSHP-NV. Over 50 years of operation, in Scenario (1) COP values of 2.45–2.55 (heating) and 3.62–4.15 (cooling) were obtained. In (2), COP values increased to 4.15–4.34 (heating) but fell to 3.36–3.79 (cooling), which increased annual final energy needs by 7–8%. Unbalanced cooling loads increased the ground temperature by 21–24 °C, which is unlikely to be acceptable. Compared to (1), introducing NV reduced cooling loads by 65–90% in Scenarios (3) and (4), with the final energy needs decreasing by 59–80% and 62–88%, respectively. A further benefit of the GSHP-NV hybrid is that the ground temperature increase was limited to 8‑12 °C. For cooling, the COP in (3) decreased compared to (1) (3.14–3.69), while in (4), COP improved to 3.45–6.10. This study concludes that hybrid GSHP-NV systems should be considered in some cooling-dominated scenarios.
- 27 September 2021
- Published by EDP Sciences in Renewable Energy and Environmental Sustainability
- Vol. 6, 33
Open AccessHybridization of Heat Pump Systems With Natural Ventilation To Improve Energy Efficiency in Cooling Dominated Buildings
Building foundation piles can be used as heat exchangers in ground-source heat pump (GSHP) systems to provide highly efficient renewable heating and cooling (H&C). Unbalanced H&C loads lead to heat build-up in the ground, decreasing the system's overall performance. In this study, the introduction of natural ventilation (NV) has been examined to decrease cooling load imbalance in cooling-dominated buildings to improve system efficiency. Building energy simulations estimated the H&C loads for an office building in three Portuguese cities: Lisbon, Porto and Faro, yielding heating loads of 0.2–3.6 MWh/year and cooling loads of 260–450 MWh/year. Four renewable H&C technology scenarios were used to assess energy performance: (1) an air-source heat pump (ASHP) system; (2) a GSHP system utilizing energy piles; (3) hybrid ASHP-NV and (4) hybrid GSHP-NV. Over 50 years of operation, in Scenario (1) COP values of 2.45–2.55 (heating) and 3.62–4.15 (cooling) were obtained. In (2), COP values increased to 4.15–4.34 (heating) but fell to 3.36–3.79 (cooling), which increased annual final energy needs by 7–8%. Unbalanced cooling loads increased the ground temperature by 21–24 °C, which is unlikely to be acceptable. Compared to (1), introducing NV reduced cooling loads by 65–90% in Scenarios (3) and (4), with the final energy needs decreasing by 59–80% and 62–88%, respectively. A further benefit of the GSHP-NV hybrid is that the ground temperature increase was limited to 8‑12 °C. For cooling, the COP in (3) decreased compared to (1) (3.14–3.69), while in (4), COP improved to 3.45–6.10. This study concludes that hybrid GSHP-NV systems should be considered in some cooling-dominated scenarios.
- 1 October 2018
- Published by Elsevier in Sustainable Cities and Society
- Vol. 42, 259-275
Impact of PM2.5 in indoor urban environments: A review
- 1 October 2018
- Published by Elsevier in Sustainable Cities and Society
- Vol. 42, 259-275
Impact of PM2.5 in indoor urban environments: A review
- 1 March 2018
- Published by Elsevier in Renewable Energy
- Vol. 117, 357-373
Effects of airborne fine particle pollution on the usability of natural ventilation in office buildings in three megacities in Asia
- 1 March 2018
- Published by Elsevier in Renewable Energy
- Vol. 117, 357-373
Effects of airborne fine particle pollution on the usability of natural ventilation in office buildings in three megacities in Asia