Pavel Karataev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pavel Karataev has a total of 490 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Petrovich Potylitsyn
Tomsk Polytechnic University, Tomsk, Russia
28 shared publications - Alexander Aryshev
High Energy Accelerator Research Organization
23 shared publications J. Urakawa
KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan
22 shared publicationsN. Terunuma
KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan
16 shared publicationsG. Naumenko
14 shared publicationsS. Araki
KEK, High Energy Accelerator Res Org, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
14 shared publications
Latest Publications
- Open Access
- 14 May 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 247
Experimental investigation of polarization and spatial properties of coherent Cherenkov diffraction radiation in super-radiant regime
- 14 May 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 247
Open AccessExperimental investigation of polarization and spatial properties of coherent Cherenkov diffraction radiation in super-radiant regime
- 16 February 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 243
Optical cherenkov radiation from a transparent plate for beam diagnostics
- 16 February 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 243
Optical cherenkov radiation from a transparent plate for beam diagnostics
- 1 November 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 240
Coherent Cherenkov diffraction radiation in super-radiant regime as a tool for longitudinal diagnostics
- 1 November 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 240
Coherent Cherenkov diffraction radiation in super-radiant regime as a tool for longitudinal diagnostics
- Open Access
- 25 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-12
Quasi-continuous X-ray generation in LiTaO3-based pyroelectric accelerator driven by periodically varying temperature
Nowadays, X-ray sources are advanced tools used to probe the properties of matter and dynamic systems. Large scale accelerator based light source facilities have been constructed around the Globe to meet the scientific, technological and societal needs. Development of compact pocket-style X-ray systems meeting safety regulations is a complementary task requiring stable, reliable, and reproducible sources of X-rays with controllable parameters. In this research we employed a new approach for pyroelectric accelerator operation. Periodically varying temperature of LiTaO3 crystal enabled us to generate stable quasi-continuous X-ray beam. We managed to observe and characterise the avalanche process at pyroelectric effect. This phenomenon is responsible for multiplication of electrons at the anode while producing X-rays. We have demonstrated the great potential of this compact X-ray source by performing reliable energy-dispersive X-ray spectroscopy for element analysis of two solid samples.
- 25 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-12
Open AccessQuasi-continuous X-ray generation in LiTaO3-based pyroelectric accelerator driven by periodically varying temperature
Nowadays, X-ray sources are advanced tools used to probe the properties of matter and dynamic systems. Large scale accelerator based light source facilities have been constructed around the Globe to meet the scientific, technological and societal needs. Development of compact pocket-style X-ray systems meeting safety regulations is a complementary task requiring stable, reliable, and reproducible sources of X-rays with controllable parameters. In this research we employed a new approach for pyroelectric accelerator operation. Periodically varying temperature of LiTaO3 crystal enabled us to generate stable quasi-continuous X-ray beam. We managed to observe and characterise the avalanche process at pyroelectric effect. This phenomenon is responsible for multiplication of electrons at the anode while producing X-rays. We have demonstrated the great potential of this compact X-ray source by performing reliable energy-dispersive X-ray spectroscopy for element analysis of two solid samples.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , P07026
Observation of Cherenkov diffraction radiation from 3D printed plastic targets
The generation of polarization radiation by electron beams passing near dielectric objects has attracted considerable attention due to its potential applications, such as beam parameter diagnostics and the generation of intense electromagnetic radiation in the THz and sub-THz frequency ranges. Among the various forms of this radiation, Cherenkov diffraction radiation (ChDR) is particularly noteworthy. ChDR arises when high-energy electrons travel parallel to and in close proximity to a long dielectric interface. The characteristics of this radiation are influenced by the properties of the charged particles, the target material, and its configuration. To produce radiators with the required precision, advanced technologies for fabricating dielectric samples with complex geometries are essential. One promising approach is 3D printing using fused filament fabrication (FFF) of plastics. However, before implementing this method, a thorough investigation into the dielectric properties of these plastics must be conducted to ensure their suitability.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , P07026
Observation of Cherenkov diffraction radiation from 3D printed plastic targets
The generation of polarization radiation by electron beams passing near dielectric objects has attracted considerable attention due to its potential applications, such as beam parameter diagnostics and the generation of intense electromagnetic radiation in the THz and sub-THz frequency ranges. Among the various forms of this radiation, Cherenkov diffraction radiation (ChDR) is particularly noteworthy. ChDR arises when high-energy electrons travel parallel to and in close proximity to a long dielectric interface. The characteristics of this radiation are influenced by the properties of the charged particles, the target material, and its configuration. To produce radiators with the required precision, advanced technologies for fabricating dielectric samples with complex geometries are essential. One promising approach is 3D printing using fused filament fabrication (FFF) of plastics. However, before implementing this method, a thorough investigation into the dielectric properties of these plastics must be conducted to ensure their suitability.
- Open Access
- 24 February 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (1)
Design and experimental verification of a bunch length monitor based on coherent Cherenkov diffraction radiation
This paper presents the design and experimental commissioning of a noninvasive electron bunch length monitor based on the detection of coherent Cherenkov diffraction radiation (ChDR). The measurement technique effectively eliminates the influence of bunch-by-bunch charge fluctuations, as each detector measures the signal from the same bunch while mitigating the impact of bunch position jitter on the measurements, providing a potential real-time diagnostic tool with significant operational advantages. The sensitivity of the measurements to both bunch length and longitudinal bunch profile was experimentally demonstrated, with results validated against invasive radio frequency deflector measurements at the CLEAR electron test facility at CERN. The ChDR bunch length monitor can be applied to accelerators operating with ultrashort bunches. Published by the American Physical Society 2025
- 24 February 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (1)
Open AccessDesign and experimental verification of a bunch length monitor based on coherent Cherenkov diffraction radiation
This paper presents the design and experimental commissioning of a noninvasive electron bunch length monitor based on the detection of coherent Cherenkov diffraction radiation (ChDR). The measurement technique effectively eliminates the influence of bunch-by-bunch charge fluctuations, as each detector measures the signal from the same bunch while mitigating the impact of bunch position jitter on the measurements, providing a potential real-time diagnostic tool with significant operational advantages. The sensitivity of the measurements to both bunch length and longitudinal bunch profile was experimentally demonstrated, with results validated against invasive radio frequency deflector measurements at the CLEAR electron test facility at CERN. The ChDR bunch length monitor can be applied to accelerators operating with ultrashort bunches. Published by the American Physical Society 2025
- 1 September 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (09) , C09001
Computer simulations of the phase-space characteristics of electrons in a pyroelectric accelerator
In this paper, we focus on simulating a pyroelectric accelerator using COMSOL Multiphysics. We utilize the static surface charge distribution obtained from an experiment conducted on a LiTaO3 single crystal surface. We analyze the characteristics of the electron flow generated by the accelerator and determine the emittance and Twiss parameters. Our findings reveal that the normalized RMS emittance remains relatively constant in the space behind the target.
- 1 September 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (09) , C09001
Computer simulations of the phase-space characteristics of electrons in a pyroelectric accelerator
In this paper, we focus on simulating a pyroelectric accelerator using COMSOL Multiphysics. We utilize the static surface charge distribution obtained from an experiment conducted on a LiTaO3 single crystal surface. We analyze the characteristics of the electron flow generated by the accelerator and determine the emittance and Twiss parameters. Our findings reveal that the normalized RMS emittance remains relatively constant in the space behind the target.
- Open Access
- 14 June 2024
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 6 (2) , 023278
Selective electron beam sensing through coherent Cherenkov diffraction radiation
We exploit the coherent emission of Cherenkov diffraction radiation (ChDR) by a relativistic electron beam to sense its position even in the presence of other particle beams. ChDR is produced in alumina inserts embedded in the vacuum chamber walls and recorded in a narrow band centered at 30 GHz. This nontrivial solution has been implemented for plasma wakefield accelerators, where the electron beam to be sensed can copropagate with another high-energy proton beam that generates the plasma wakefield. In addition, at variance with most existing position detectors, this method is insensitive to spurious electric charges due to the presence of plasma. We present the overall design of the detector as well as experimental results obtained in the AWAKE facility at CERN. Published by the American Physical Society 2024
- 14 June 2024
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 6 (2) , 023278
Open AccessSelective electron beam sensing through coherent Cherenkov diffraction radiation
We exploit the coherent emission of Cherenkov diffraction radiation (ChDR) by a relativistic electron beam to sense its position even in the presence of other particle beams. ChDR is produced in alumina inserts embedded in the vacuum chamber walls and recorded in a narrow band centered at 30 GHz. This nontrivial solution has been implemented for plasma wakefield accelerators, where the electron beam to be sensed can copropagate with another high-energy proton beam that generates the plasma wakefield. In addition, at variance with most existing position detectors, this method is insensitive to spurious electric charges due to the presence of plasma. We present the overall design of the detector as well as experimental results obtained in the AWAKE facility at CERN. Published by the American Physical Society 2024
- 22 November 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (20) , 204101
Peculiarities of the pyroelectric current generated using a LiNbO3 single crystal driven by low-frequency sinusoidal temperature variation
Lithium niobate (LiNbO3) single crystal is one of the pyroelectric materials, which can be applicable in energy storage and conversion devices. A theoretical and experimental study of the sinusoidal temperature variation of a single crystal of LiNbO3 with ultra-low frequency of 1–80 mHz is presented here. The previously unreported phenomenon of the optimal frequency range with the maximum amplitude of pyroelectric current oscillations is shown. It is noted that the observed effect is very sensitive to the thermal properties of the material. The impact of thermal properties of the crystal on the optimal frequency range is discussed. The accurate calculations of the pyroelectric coefficient using sinusoidal temperature variation are introduced. The observed phenomenon can be applied in pyroelectric energy converters and storage devices having a cycle time of 10–1000 s.
- 22 November 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (20) , 204101
Peculiarities of the pyroelectric current generated using a LiNbO3 single crystal driven by low-frequency sinusoidal temperature variation
Lithium niobate (LiNbO3) single crystal is one of the pyroelectric materials, which can be applicable in energy storage and conversion devices. A theoretical and experimental study of the sinusoidal temperature variation of a single crystal of LiNbO3 with ultra-low frequency of 1–80 mHz is presented here. The previously unreported phenomenon of the optimal frequency range with the maximum amplitude of pyroelectric current oscillations is shown. It is noted that the observed effect is very sensitive to the thermal properties of the material. The impact of thermal properties of the crystal on the optimal frequency range is discussed. The accurate calculations of the pyroelectric coefficient using sinusoidal temperature variation are introduced. The observed phenomenon can be applied in pyroelectric energy converters and storage devices having a cycle time of 10–1000 s.
- Open Access
- 17 May 2022
- Published by IOP Publishing in Applied Physics Express
- Vol. 15 (6) , 066001
Indicators of upcoming electric breakdown in a pyroelectric accelerator
This paper describes indicators that can be used to monitor the operating mode of a pyroelectric accelerator. It is shown that the ratio of the characteristic X-ray emission lines from the target and the vacuum chamber walls is very sensitive to the state of the accelerator. Also, the peak to total count rate ratio in the electron spectrum exhibits similar properties. These parameters change sharply ahead of the electric breakdown and are very sensitive to the residual gas pressure level. Monitoring these indicators during the accelerator operation provides a fine tool aiding the implementation of pyroelectric technology for stable and reliable charged particle generation and acceleration.
- 17 May 2022
- Published by IOP Publishing in Applied Physics Express
- Vol. 15 (6) , 066001
Open AccessIndicators of upcoming electric breakdown in a pyroelectric accelerator
This paper describes indicators that can be used to monitor the operating mode of a pyroelectric accelerator. It is shown that the ratio of the characteristic X-ray emission lines from the target and the vacuum chamber walls is very sensitive to the state of the accelerator. Also, the peak to total count rate ratio in the electron spectrum exhibits similar properties. These parameters change sharply ahead of the electric breakdown and are very sensitive to the residual gas pressure level. Monitoring these indicators during the accelerator operation provides a fine tool aiding the implementation of pyroelectric technology for stable and reliable charged particle generation and acceleration.