Latest Publications

  • Phase Locked Loop (PLL) MPPT Based Single Stage Grid-Connected PV System

    by Pratap Ranjan Mohanty, K Praneeth Guptha, N Sowmya, S S Jaheer Hussain, G Siva Nanda Kishore

    This paper focuses on phase-locked loop (PLL) based MPPT control configuration for single stage grid-connected PV system. The proposed PLL based MPPT technique is working on synchronization algorithm features. The PLL is introduced to offer unity pf operation that includes synchronization between the output current of inverter and grid voltage. Also, PLL based control structure is to provide pure sinusoidal current reference. The PLL is used for the monitoring of grid voltage to achieve amplitude and frequency equal to the grid level. In this research work, incremental conductance manner is implemented for the MPPT control algorithm. The performance of the proposed control configuration is examined in MATLAB/Simulink state for a grid-attached PV system. In this work, the proposed controller scheme is implemented for a grid connected PV system of 52 kW grid capacity and 2 kW PV system which is being supplied to 50 kW load. The waveforms are presented which describe the superiority of the proposed scheme.


  • DEC fuel cell‐based universal power compensator for dual PCC system

    by Nishant Patnaik, Anup Kumar Panda, Pratap Ranjan Mohanty, Richa Pandey

    This article proposes a special type of power conditioning system, termed as UPC (Universal Power Compensator) for a three‐phase four wire system to take care of several power quality aspects as well as supply interruption conditions, suitable for combination of different load coupling points, that is, PCC (point of common coupling). Two different PCCs are considered in the system, out of which one is a voltage sensitive point. UPC consist of a special UPQC arrangement, termed as left‐shunt UPQC and an external (independent) power source such as a fuel cell system (FCS) that includes fuel cell stack with DC‐DC converter. This arrangement prevents the effect of voltage disturbance on sensitive load point in addition to mitigating the current harmonic contamination from both the load points. The control structure for UPQC is based on direct DC‐link voltage control and is of prime importance and has been suitably adopted for the proposed arrangement. Also, a dynamic evolution control (DEC) algorithm is proposed for FCS of UPC for quick response under transient conditions, such as connection instant and load changes. Various performance domains such as harmonic compensation, voltage compensation, neutral current compensation and supply compensation of UPC are analyzed using simulation analysis with MATLAB/SIMULINK. Also, a comparative performance analysis is illustrated to indicate the superiority of DEC‐FC system.


  • Closed-Loop-Controlled Cascaded Current-Controlled Dynamic Evolution Control-Based Voltage-Doubler PFC Converter for Improved Dynamic Performance

    by Anup Kumar Panda, Pratap Ranjan Mohanty, Nishant Patnaik, Trilochan Penthia

    In this paper, the closed-loop performance of Voltage-Doubler Power Factor Correction (VD PFC) converter under Dynamic Evolution Control (DEC) scheme is examined. The VD PFC circuit mainly used for enhancing low-line efficiency with reduced conduction and switching losses is essentially required to operate at high duty ratio (say D > 0.5). The proposed DEC scheme ensures this operating feature even under transient conditions. Since, researchers haven’t focused on the dynamic performance of the closed-loop controller for the VD PFC converter, the effectiveness of the proposed DEC technique is comparatively evaluated by implementing it in different control loops. In this research work, the DEC is separately implemented in voltage control loop and in current control loop which is termed as VC-DEC scheme and CC-DEC scheme respectively. The dynamic performance (quick response of desired output) and voltage-doubler property of the VD PFC converter under the open-loop condition, VC-DEC scheme, CC-DEC scheme are tested at a low-line input range of 70VRMS to 100VRMS to justify its characteristics of enhanced low-line efficiency. Besides, its performance is tested for different loading conditions based on several key performance indices. The relevant switching functions for VD PFC converter are derived by considering its system dynamics and corresponding loop dynamic. A hardware prototype of 390 VDC, 1.5 kW VD-PFC is designed with the controller being implemented using MATLAB/Simulink and dSPACE1104 interface.


  • Fixed-Frequency Sliding-Mode Control Scheme Based on Current Control Manifold for Improved Dynamic Performance of Boost PFC Converter

    by Pratap Ranjan Mohanty, Anup Kumar Panda

    This paper deals with the switching regulation of boost power factor correction (PFC) converter under large and quick load fluctuation to ensure tight output voltage regulation and unity PF (UPF) at line side. In this sense, the sliding-mode control (SMC) technique based on current-controlled manifold is proposed. Input current distortion is limited even during light loading condition. In addition, the dead-zone issue related to light load near to the crossover of input current is resolved in this paper. To execute the proposed SMC algorithm, equivalent control approach is used for the selection of sliding coefficients, ensuring the system stability. The control operation manipulates both inner SM current controller to frame input current and an outer PI controller to maintain desired regulated output voltage. For experimental validation, a 500-W, 390 V/dc boost PFC prototype, controlled by dSPACE 1104 signal processor is framed. The presented simulation and experimental results infer that the proposed converter controller offers UPF, tight output voltage regulation, and percentage total harmonic distortion standard even under fluctuating load behavior. In this paper, the performance of the proposed control scheme is experimentally verified with different load behaviors and external references, which explains the robustness and effectiveness of the proposed system.


  • An active PFC boost converter topology for power factor correction

    by Pratap Ranjan Mohanty, Anup Kumar Panda, Dhiman Das

    This paper introduces a single-stage active power factor correction (PFC) AC-DC converter which provides almost unity power factor and minimizes the THD to 7.4 %. For a constant DC output voltage a single phase diode bridge rectifier with a large output capacitor is considered in this paper. This standard topology has a shortcoming of introducing lower order harmonics and become cause of poor power factor, which needs to be improved. MATLAB Simulation software is used to simulate a simulation model of 350 W output for both passive and active PFC methods. Simultaneously, the experimental prototype for 350W/390V output with active PFC method is designed and experimental results are verified.


  • Synchronization and operation of parallel inverters using droop control

    by L. K. Sahoo, N. D. Thakur, K. Rai, P Sensarma, R. D. Jha, P. Mohanty, A Sharma, A. S. Srinidhi, A. Chaurey

    To obtain a continuous power supply Distributed Generation (DG) with a Decentralized Power System (DPS), i.e. replacing a single UPS unit with multiple, smaller units in parallel, is emerging as new paradigm. The technically challenging aspect of DPS is the synchronization of inverters and load sharing among the parallel connected inverters. In this paper, a control method is proposed and implemented for synchronization and parallel operation of inverters. Droop control method has been used for equal power sharing, and design of power control loop. The design issues for voltage control loop are analyzed with the discussion of relative stability of the system. A current control loop is designed and analyzed to provide synchronization between the inverters.