Dora Melucci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dora Melucci has a total of 181 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Zappi
Department of Chemistry “Giacomo Ciamician”, University of Bologna, Bologna, Italy
20 shared publications - Clinio Locatelli
Department of Chemistry “G. Ciamician”, University of Bologna, 40126 Bologna, Italy
9 shared publications - Marcello Locatelli
Department of Science, University “G. d’Annunzio” of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy
9 shared publications G. Torsi
University of Bologna
7 shared publicationsP. Reschiglian
Department of Chemistry “G. Ciamician” , University of Bologna , via F. Selmi 2, Bologna, I-40126, Italy
7 shared publications- Andrea Zattoni
Department of Chemistry “Giacomo Ciamician”, University of Bologna, 40129 Bologna, Italy
6 shared publications
Latest Publications
- Open Access
- 16 January 2026
- Published by MDPI AG in Separations
- Vol. 13 (1) , 36
A Comprehensive GC-MS Approach for Monitoring Legacy and Emerging Halogenated Contaminants in Human Biomonitoring
Human exposure to persistent organic pollutants such as polychlorinated biphenyls (PCB) and brominated flame retardants (BFR), including both legacy and emerging compounds, remains a concern due to their bioaccumulative nature and potential health effects. Comprehensive analytical methods are necessary to monitor these substances in complex biological matrices, such as human serum. A gas chromatography–mass spectrometry (GC-MS) method was developed for the simultaneous determination of 44 analytes, encompassing PCB and a broad spectrum of BFR with diverse physicochemical properties. The extraction procedure and GC-MS parameters were optimized using a design of experiments approach to maximize performance while minimizing analysis time. The method demonstrated high sensitivity, precision, and accuracy, thereby meeting internationally recognized validation criteria for biomonitoring applications. To further ensure analytical reliability, compound confirmation was achieved using gas chromatography–high-resolution mass spectrometry, providing enhanced selectivity and confidence in identification, particularly for low-level analytes. Key advantages of the method include its applicability to analytes with significantly different chemical behaviors and its capacity to quantify a large number of target compounds simultaneously. This makes it a powerful tool for assessing human exposure to both regulated and emerging halogenated contaminants.
- 16 January 2026
- Published by MDPI AG in Separations
- Vol. 13 (1) , 36
Open AccessA Comprehensive GC-MS Approach for Monitoring Legacy and Emerging Halogenated Contaminants in Human Biomonitoring
Human exposure to persistent organic pollutants such as polychlorinated biphenyls (PCB) and brominated flame retardants (BFR), including both legacy and emerging compounds, remains a concern due to their bioaccumulative nature and potential health effects. Comprehensive analytical methods are necessary to monitor these substances in complex biological matrices, such as human serum. A gas chromatography–mass spectrometry (GC-MS) method was developed for the simultaneous determination of 44 analytes, encompassing PCB and a broad spectrum of BFR with diverse physicochemical properties. The extraction procedure and GC-MS parameters were optimized using a design of experiments approach to maximize performance while minimizing analysis time. The method demonstrated high sensitivity, precision, and accuracy, thereby meeting internationally recognized validation criteria for biomonitoring applications. To further ensure analytical reliability, compound confirmation was achieved using gas chromatography–high-resolution mass spectrometry, providing enhanced selectivity and confidence in identification, particularly for low-level analytes. Key advantages of the method include its applicability to analytes with significantly different chemical behaviors and its capacity to quantify a large number of target compounds simultaneously. This makes it a powerful tool for assessing human exposure to both regulated and emerging halogenated contaminants.
- Open Access
- 4 September 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (5) , 1700-1711
Solid solution quantification from full powder X-ray diffraction profile: novel application of multivariate calibration
Non-stochiometric crystals, such as solid solutions, represent a valid strategy for fine-tuning the properties of materials from inorganic pigments to active pharmaceutical ingredients. The change is achieved by substitution of structurally similar compounds within the crystal structure, resulting in a minor variation of cell parameters, and it can be experimentally observed as a shift of the X-ray diffraction profile, with the shift depending on the substitutional amount. After proper alignment of the diffraction data, chemometric methods can detect the evolution of the solid solution profile and correlate it to the molar composition, creating rapid quantitative models. The solid solutions chosen for this work are NA2·FA x SA1−x and IN2·FA x SA1−x , i.e. co-crystals of nicotinamide (NA) and isonicotinamide (IN) with fumaric acid (FA) and succinic acid (SA) in different proportions; they are used as model systems for the development of principal component regression and partial least-squares models for the quantification of solid solution composition. Different alignment strategies are presented, and the results obtained from test samples show the prediction efficacy of the proposed approach.
- 4 September 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (5) , 1700-1711
Open AccessSolid solution quantification from full powder X-ray diffraction profile: novel application of multivariate calibration
Non-stochiometric crystals, such as solid solutions, represent a valid strategy for fine-tuning the properties of materials from inorganic pigments to active pharmaceutical ingredients. The change is achieved by substitution of structurally similar compounds within the crystal structure, resulting in a minor variation of cell parameters, and it can be experimentally observed as a shift of the X-ray diffraction profile, with the shift depending on the substitutional amount. After proper alignment of the diffraction data, chemometric methods can detect the evolution of the solid solution profile and correlate it to the molar composition, creating rapid quantitative models. The solid solutions chosen for this work are NA2·FA x SA1−x and IN2·FA x SA1−x , i.e. co-crystals of nicotinamide (NA) and isonicotinamide (IN) with fumaric acid (FA) and succinic acid (SA) in different proportions; they are used as model systems for the development of principal component regression and partial least-squares models for the quantification of solid solution composition. Different alignment strategies are presented, and the results obtained from test samples show the prediction efficacy of the proposed approach.
- Open Access
- 1 November 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (11) , 227
Analysis of Solid Formulates Using UV-Visible Diffused Reflectance Spectroscopy with Multivariate Data Processing Based on Net Analyte Signal and Standard Additions Method
Quality control in pharmaceutical manufacturing necessitates rigorous testing and approval, adhering to Current Good Manufacturing Practices before commercialization. The production of solid drugs presents significant industrial challenges regarding uniformity, homogeneity, and consistency. Traditional quality guidelines rely on classical analytical methods such as liquid chromatography coupled with mass spectrometry. However, the emergence of Process Analytical Technology introduced non-destructive, rapid, and cost-effective methods like UV-Visible Diffuse Reflectance Spectroscopy. The present study aimed to develop a chemometric method for quantifying Active Pharmaceutical Ingredients (APIs) in Neo Nisidine®, a solid mixture drug, using spectrophotometric data. The Net Analyte Signal (NAS) method, combined with standard additions, allowed the creation of a pseudo-univariate standard addition model, overcoming some challenges in solid-phase analysis. Successful quantifications of APIs in ideal laboratory samples and real pharmaceutical tablets were obtained. NAS-based chemometric models showed high precision and reliability, whose results were validated by comparisons with HPLC ones. The study revealed that solid-phase spectrophotometric analyses can be considered a valid alternative to API analyses. Solid-phase analysis offers non-destructive, cost-effective, and environmentally friendly benefits, enabling its integration into pharmaceutical production to improve quality control.
- 1 November 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (11) , 227
Open AccessAnalysis of Solid Formulates Using UV-Visible Diffused Reflectance Spectroscopy with Multivariate Data Processing Based on Net Analyte Signal and Standard Additions Method
Quality control in pharmaceutical manufacturing necessitates rigorous testing and approval, adhering to Current Good Manufacturing Practices before commercialization. The production of solid drugs presents significant industrial challenges regarding uniformity, homogeneity, and consistency. Traditional quality guidelines rely on classical analytical methods such as liquid chromatography coupled with mass spectrometry. However, the emergence of Process Analytical Technology introduced non-destructive, rapid, and cost-effective methods like UV-Visible Diffuse Reflectance Spectroscopy. The present study aimed to develop a chemometric method for quantifying Active Pharmaceutical Ingredients (APIs) in Neo Nisidine®, a solid mixture drug, using spectrophotometric data. The Net Analyte Signal (NAS) method, combined with standard additions, allowed the creation of a pseudo-univariate standard addition model, overcoming some challenges in solid-phase analysis. Successful quantifications of APIs in ideal laboratory samples and real pharmaceutical tablets were obtained. NAS-based chemometric models showed high precision and reliability, whose results were validated by comparisons with HPLC ones. The study revealed that solid-phase spectrophotometric analyses can be considered a valid alternative to API analyses. Solid-phase analysis offers non-destructive, cost-effective, and environmentally friendly benefits, enabling its integration into pharmaceutical production to improve quality control.
- Open Access
Quantification of Recycled PET in Commercial Bottles by IR Spectroscopy and Chemometrics
A novel approach for the quantification of recycled polyethylene terephthalate (r-PET) in commercial bottles is presented. Fifty-eight bottle samples from several brands and producers containing different percentages of r-PET were purchased from the market. Samples were analyzed by two spectroscopic methods: near-infrared (NIR) spectroscopy and attenuated total reflection (ATR) spectroscopy in the mid-infrared (MIR) region. No chemical pre-treatment was applied before analyses. The spectra were analyzed by partial-least squares (PLS) regression, and two models for NIR and MIR data were computed. Then, a multi-block regression was applied to join the two datasets. All models were validated by cross-validation and by excluding and projecting onto the model the replicated spectra of one sample at a time. Results demonstrated the potential of this approach, especially considering the variability of commercial samples in terms of additives, shape, or thickness of the bottles: for samples close to the centroids of the models (i.e., from 10 to 50% r-PET), the predictions of multi-block method seldom departed from the expected values of ±10%. Only for samples with 0% declared r-PET, the models showed poor prediction abilities.
Open AccessQuantification of Recycled PET in Commercial Bottles by IR Spectroscopy and Chemometrics
A novel approach for the quantification of recycled polyethylene terephthalate (r-PET) in commercial bottles is presented. Fifty-eight bottle samples from several brands and producers containing different percentages of r-PET were purchased from the market. Samples were analyzed by two spectroscopic methods: near-infrared (NIR) spectroscopy and attenuated total reflection (ATR) spectroscopy in the mid-infrared (MIR) region. No chemical pre-treatment was applied before analyses. The spectra were analyzed by partial-least squares (PLS) regression, and two models for NIR and MIR data were computed. Then, a multi-block regression was applied to join the two datasets. All models were validated by cross-validation and by excluding and projecting onto the model the replicated spectra of one sample at a time. Results demonstrated the potential of this approach, especially considering the variability of commercial samples in terms of additives, shape, or thickness of the bottles: for samples close to the centroids of the models (i.e., from 10 to 50% r-PET), the predictions of multi-block method seldom departed from the expected values of ±10%. Only for samples with 0% declared r-PET, the models showed poor prediction abilities.
- Open Access
- 5 April 2024
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 656, 124090
Analytical comparison between batch and continuous direct compression processes for pharmaceutical manufacturing using an innovative UV–Vis reflectance method and chemometrics
- 5 April 2024
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 656, 124090
Open AccessAnalytical comparison between batch and continuous direct compression processes for pharmaceutical manufacturing using an innovative UV–Vis reflectance method and chemometrics
- Open Access
- 1 March 2023
- Published by PAGEPress Publications in Italian Journal of Medicine
- Vol. 17 (1)
Characteristics, comorbidities and laboratory measures associated with disease severity and poor prognosis in young and elderly patients with COVID-19 admitted to medical wards in Emilia-Romagna region, Italy: a multicentre retrospective study
Background and Objectives. A relatively small number of studies have investigated the characteristics, comorbidities and laboratory measures associated with prognosis in patients with COVID-19, admitted to Internal Medicine Units (IMU) in Italy. Therefore, we performed a retrospective multicentre study to identify baseline features, predisposing to severe disease and poor outcomes, in adult individuals with SARS-CoV-2 infection, hospitalized in 5 IMUs in the Emilia-Romagna region (Italy). Materials and Methods. We included 129 consecutive patients (male 75, median age 68 years) from 1st March 2020 to 31st October 2021. Patients’ baseline characteristics, comorbidities, laboratory measures, and outcomes were collected. Results. At admission, the factors significantly associated with a higher risk of in-hospital mortality included: age (median 68 vs. 83 years in survived vs. dead patients, P=0.000), diabetes [Odds Ratio (OR) 4.00, P=0.016], chronic obstructive pulmonary disease (OR 4.60, P=0.022), cancer (OR 5.81, P=0.021), acute- (OR 9.88, P=0.000) and chronic-renal failure (OR 6.76, P=0.004). During the study period, 16 individuals died (12.4%), all over 70 years old. In deceased vs. non-deceased patients were detected: i) more elevated white blood cells and neutrophils-counts and lower lymphocytes count; ii) higher levels of total/direct bilirubin, creatinine, C-reactive-protein, lactate-dehydrogenase, ferritin, but only a slight Interleukin-6 increase; iii) a trend of lower vitamin D values. Conclusions. We proposed a new I index, a modified form of the Age-Adjusted Charlson Comorbidity Index, by considering pO2/FiO2 ratio, to better characterize the severity of COVID-19. Furthermore, we critically discuss our results with the current assumption which considers COVID-19 as a pathological condition associated with cytokine storm.
- 1 March 2023
- Published by PAGEPress Publications in Italian Journal of Medicine
- Vol. 17 (1)
Open AccessCharacteristics, comorbidities and laboratory measures associated with disease severity and poor prognosis in young and elderly patients with COVID-19 admitted to medical wards in Emilia-Romagna region, Italy: a multicentre retrospective study
Background and Objectives. A relatively small number of studies have investigated the characteristics, comorbidities and laboratory measures associated with prognosis in patients with COVID-19, admitted to Internal Medicine Units (IMU) in Italy. Therefore, we performed a retrospective multicentre study to identify baseline features, predisposing to severe disease and poor outcomes, in adult individuals with SARS-CoV-2 infection, hospitalized in 5 IMUs in the Emilia-Romagna region (Italy). Materials and Methods. We included 129 consecutive patients (male 75, median age 68 years) from 1st March 2020 to 31st October 2021. Patients’ baseline characteristics, comorbidities, laboratory measures, and outcomes were collected. Results. At admission, the factors significantly associated with a higher risk of in-hospital mortality included: age (median 68 vs. 83 years in survived vs. dead patients, P=0.000), diabetes [Odds Ratio (OR) 4.00, P=0.016], chronic obstructive pulmonary disease (OR 4.60, P=0.022), cancer (OR 5.81, P=0.021), acute- (OR 9.88, P=0.000) and chronic-renal failure (OR 6.76, P=0.004). During the study period, 16 individuals died (12.4%), all over 70 years old. In deceased vs. non-deceased patients were detected: i) more elevated white blood cells and neutrophils-counts and lower lymphocytes count; ii) higher levels of total/direct bilirubin, creatinine, C-reactive-protein, lactate-dehydrogenase, ferritin, but only a slight Interleukin-6 increase; iii) a trend of lower vitamin D values. Conclusions. We proposed a new I index, a modified form of the Age-Adjusted Charlson Comorbidity Index, by considering pO2/FiO2 ratio, to better characterize the severity of COVID-19. Furthermore, we critically discuss our results with the current assumption which considers COVID-19 as a pathological condition associated with cytokine storm.
- Open Access
Phytochemicals Recovery from Grape Pomace: Extraction Improvement and Chemometric Study
In the last 20 years, an increased interest has been shown in the application of different types and combinations of enzymes to obtain phenolic extracts from grape pomace in order to maximize its valorization. Within this framework, the present study aims at improving the recovery of phenolic compounds from Merlot and Garganega pomace and at contributing to the scientific background of enzyme-assisted extraction. Five commercial cellulolytic enzymes were tested in different conditions. Phenolic compound extraction yields were analyzed via a Design of Experiments (DoE) methodology and a second extraction step with acetone was sequentially added. According to DoE, 2% w/w enzyme/substrate ratio was more effective than 1%, allowing a higher total phenol recovery, while the effect of incubation time (2 or 4 h) variation was more enzyme-dependent. Extracts were characterized via spectrophotometric and HPLC-DAD analyses. The results proved that enzymatic and acetone Merlot and Garganega pomace extracts were complex mixtures of compounds. The use of different cellulolytic enzymes led to different extract compositions, as demonstrated using PCA models. The enzyme effects were observed both in water enzymatic and in the subsequent acetone extracts, probably due to their specific grape cell wall degradation and leading to the recovery of different molecule arrays.
Open AccessPhytochemicals Recovery from Grape Pomace: Extraction Improvement and Chemometric Study
In the last 20 years, an increased interest has been shown in the application of different types and combinations of enzymes to obtain phenolic extracts from grape pomace in order to maximize its valorization. Within this framework, the present study aims at improving the recovery of phenolic compounds from Merlot and Garganega pomace and at contributing to the scientific background of enzyme-assisted extraction. Five commercial cellulolytic enzymes were tested in different conditions. Phenolic compound extraction yields were analyzed via a Design of Experiments (DoE) methodology and a second extraction step with acetone was sequentially added. According to DoE, 2% w/w enzyme/substrate ratio was more effective than 1%, allowing a higher total phenol recovery, while the effect of incubation time (2 or 4 h) variation was more enzyme-dependent. Extracts were characterized via spectrophotometric and HPLC-DAD analyses. The results proved that enzymatic and acetone Merlot and Garganega pomace extracts were complex mixtures of compounds. The use of different cellulolytic enzymes led to different extract compositions, as demonstrated using PCA models. The enzyme effects were observed both in water enzymatic and in the subsequent acetone extracts, probably due to their specific grape cell wall degradation and leading to the recovery of different molecule arrays.
- Open Access
- 4 January 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (1) , 45
Extracting Information and Enhancing the Quality of Separation Data: A Review on Chemometrics-Assisted Analysis of Volatile, Soluble and Colloidal Samples
Instrument automation, technological advancements and improved computational power made separation science an extremely data-rich approach, requiring the use of statistical and data analysis tools that are able to optimize processes and combine multiple outputs. The use of chemometrics is growing, greatly improving the ability to extract meaningful information. Separation–multidetection generates multidimensional data, whose elaboration should not be left to the discretion of the operator. However, some applications or techniques still suffer from the lack of method optimization through DoE and downstream multivariate analysis, limiting their potential. This review aims at summarizing how chemometrics can assist analytical chemists in terms of data elaboration and method design, focusing on what can be achieved by applying chemometric approaches to separation science. Recent applications of chemometrics in separation analyses, in particular in gas, liquid and size-exclusion chromatography, together with field flow fractionation, will be detailed to visualize the state of the art of separation chemometrics, encompassing volatile, soluble and solid (colloidal) analytes. The samples considered will range from food chemistry and environmental chemistry to bio/pharmaceutical science.
- 4 January 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (1) , 45
Open AccessExtracting Information and Enhancing the Quality of Separation Data: A Review on Chemometrics-Assisted Analysis of Volatile, Soluble and Colloidal Samples
Instrument automation, technological advancements and improved computational power made separation science an extremely data-rich approach, requiring the use of statistical and data analysis tools that are able to optimize processes and combine multiple outputs. The use of chemometrics is growing, greatly improving the ability to extract meaningful information. Separation–multidetection generates multidimensional data, whose elaboration should not be left to the discretion of the operator. However, some applications or techniques still suffer from the lack of method optimization through DoE and downstream multivariate analysis, limiting their potential. This review aims at summarizing how chemometrics can assist analytical chemists in terms of data elaboration and method design, focusing on what can be achieved by applying chemometric approaches to separation science. Recent applications of chemometrics in separation analyses, in particular in gas, liquid and size-exclusion chromatography, together with field flow fractionation, will be detailed to visualize the state of the art of separation chemometrics, encompassing volatile, soluble and solid (colloidal) analytes. The samples considered will range from food chemistry and environmental chemistry to bio/pharmaceutical science.
- Open Access
A Green Analytical Method Combined with Chemometrics for Traceability of Tomato Sauce Based on Colloidal and Volatile Fingerprinting
Tomato sauce is a world famous food product. Despite standards regulating the production of tomato derivatives, the market suffers frpm fraud such as product adulteration, origin mislabelling and counterfeiting. Methods suitable to discriminate the geographical origin of food samples and identify counterfeits are required. Chemometric approaches offer valuable information: data on tomato sauce is usually obtained through chromatography (HPLC and GC) coupled to mass spectrometry, which requires chemical pretreatment and the use of organic solvents. In this paper, a faster, cheaper, and greener analytical procedure has been developed for the analysis of volatile organic compounds (VOCs) and the colloidal fraction via multivariate statistical analysis. Tomato sauce VOCs were analysed by GC coupled to flame ionisation (GC-FID) and to ion mobility spectrometry (GC-IMS). Instead of using HPLC, the colloidal fraction was analysed by asymmetric flow field-fractionation (AF4), which was applied to this kind of sample for the first time. The GC and AF4 data showed promising perspectives in food-quality control: the AF4 method yielded comparable or better results than GC-IMS and offered complementary information. The ability to work in saline conditions with easy pretreatment and no chemical waste is a significant advantage compared to environmentally heavy techniques. The method presented here should therefore be taken into consideration when designing chemometric approaches which encompass a large number of samples.
Open AccessA Green Analytical Method Combined with Chemometrics for Traceability of Tomato Sauce Based on Colloidal and Volatile Fingerprinting
Tomato sauce is a world famous food product. Despite standards regulating the production of tomato derivatives, the market suffers frpm fraud such as product adulteration, origin mislabelling and counterfeiting. Methods suitable to discriminate the geographical origin of food samples and identify counterfeits are required. Chemometric approaches offer valuable information: data on tomato sauce is usually obtained through chromatography (HPLC and GC) coupled to mass spectrometry, which requires chemical pretreatment and the use of organic solvents. In this paper, a faster, cheaper, and greener analytical procedure has been developed for the analysis of volatile organic compounds (VOCs) and the colloidal fraction via multivariate statistical analysis. Tomato sauce VOCs were analysed by GC coupled to flame ionisation (GC-FID) and to ion mobility spectrometry (GC-IMS). Instead of using HPLC, the colloidal fraction was analysed by asymmetric flow field-fractionation (AF4), which was applied to this kind of sample for the first time. The GC and AF4 data showed promising perspectives in food-quality control: the AF4 method yielded comparable or better results than GC-IMS and offered complementary information. The ability to work in saline conditions with easy pretreatment and no chemical waste is a significant advantage compared to environmentally heavy techniques. The method presented here should therefore be taken into consideration when designing chemometric approaches which encompass a large number of samples.
- Open Access
The Design of Experiment as a Tool to Model Plant Trace-Metal Bioindication Abilities
Bioindicator plants are species that have the capacity to linearly uptake some elements (metal and metalloids) from the growing substrate, thus reflecting their concentration in the soil. Many factors can influence the uptake of these elements by plants, among which is the simultaneous presence of several metals, a common situation in contaminated or natural soils. A novel approach that can be used to validate the bioindication ability of a species growing on a polymetallic substrate is the design of experiment (DoE) approach. The aim of the present study was to apply the DoE in full factorial mode to model the Cu, Cd, Pb, Zn, and Cr bioindication capacity of Polygonum aviculare, used as the model plant. The results showed that P. aviculare has the ability to bioindicate Cd and Cr with a linear uptake (from 0.35 to 6.66, and 0.1 to 3.4 mg kg−1, respectively) unaffected by the presence of other metals. Conversely, the uptake of Pb, Cu, and Zn is strongly influenced by the presence of all the studied metals, making their concentration in the plant shoot not proportional to that of the soil. In conclusion, these preliminary results confirmed that the DoE can be used to predict the bioindicator abilities of a plant for several elements at the same time and to evaluate the interactions that can be established between variables in the growing medium and in the plant itself. However, more studies including other plant species are needed to confirm the effectiveness of this method.
Open AccessThe Design of Experiment as a Tool to Model Plant Trace-Metal Bioindication Abilities
Bioindicator plants are species that have the capacity to linearly uptake some elements (metal and metalloids) from the growing substrate, thus reflecting their concentration in the soil. Many factors can influence the uptake of these elements by plants, among which is the simultaneous presence of several metals, a common situation in contaminated or natural soils. A novel approach that can be used to validate the bioindication ability of a species growing on a polymetallic substrate is the design of experiment (DoE) approach. The aim of the present study was to apply the DoE in full factorial mode to model the Cu, Cd, Pb, Zn, and Cr bioindication capacity of Polygonum aviculare, used as the model plant. The results showed that P. aviculare has the ability to bioindicate Cd and Cr with a linear uptake (from 0.35 to 6.66, and 0.1 to 3.4 mg kg−1, respectively) unaffected by the presence of other metals. Conversely, the uptake of Pb, Cu, and Zn is strongly influenced by the presence of all the studied metals, making their concentration in the plant shoot not proportional to that of the soil. In conclusion, these preliminary results confirmed that the DoE can be used to predict the bioindicator abilities of a plant for several elements at the same time and to evaluate the interactions that can be established between variables in the growing medium and in the plant itself. However, more studies including other plant species are needed to confirm the effectiveness of this method.