Alex Hayes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Alex Hayes has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- David Anthony Morrison
Centre for Advanced Macromolecular Design, School of Chemical Engineering and Industrial Chemistry, The University of New South Wales, Sydney, New South Wales 2052, Australia
3 shared publications - David G. Lloyd
Australian Centre for Precision Health and Technology (PRECISE), Griffith University
2 shared publications - Jian-Ping Wu
D Imaging and Bioengineering Laboratory, Department of Mechanical Engineering, Curtin University, Australia
2 shared publications - Allan Wang
Division of Surgery, Medical School, University of Western Australia, Perth, WA 6009, Australia
1 shared publication Arul Bala
Department of Neurosurgery, Sir Charles Gairdner Hospital, Nedlands, Australia
1 shared publication- Chandan Ms Jadhav
Plastics & Maxillofacial Reconstructive Unit Royal Perth Hospital, 197 Wellington St, Perth WA 6000
1 shared publication
Latest Publications
- 1 May 2020
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 106 (3) , 563-568
Improved accuracy of CT based measurements for anterior prominence of acetabular prosthesis using a novel protocol based on anatomical landmarks
- 1 May 2020
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 106 (3) , 563-568
Improved accuracy of CT based measurements for anterior prominence of acetabular prosthesis using a novel protocol based on anatomical landmarks
- 1 March 2020
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 29 (3) , 617-623
Computer navigation of the glenoid component in reverse total shoulder arthroplasty: a clinical trial to evaluate the learning curve
- 1 March 2020
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 29 (3) , 617-623
Computer navigation of the glenoid component in reverse total shoulder arthroplasty: a clinical trial to evaluate the learning curve
- 1 May 2019
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 34 (5) , 987-990
Can Prophylactic Cables Stop Crack Propagation in Revision Arthroplasty: A Biomechanical Study
- 1 May 2019
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 34 (5) , 987-990
Can Prophylactic Cables Stop Crack Propagation in Revision Arthroplasty: A Biomechanical Study
- Open Access
- 14 January 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 18
A review of methods to measure tendon dimensions
Tendons are soft tissues of the musculoskeletal system that are designed to facilitate joint movement. Tendons exhibit a wide range of mechanical properties matched to their functions and, as a result, have been of interest to researchers for many decades. Dimensions are an important aspect of tendon properties. Change in the dimensions of tissues is often seen as a sign of injury and degeneration, as it may suggest inflammation or general disorder of the tissue. Dimensions are also important for determining the mechanical properties and behaviours of materials, particularly the stress, strain, and elastic modulus. This makes the dimensions significant in the context of a mechanical study of degenerated tendons. Additionally, tendon dimensions are useful in planning harvesting for tendon transfer and joint reconstruction purposes. Historically, many methods have been used in an attempt to accurately measure the dimensions of soft tissue, since improper measurement can lead to large errors in the calculated properties. These methods can be categorised as destructive (by approximation), contact, and non-contact and can be considered in terms of in vivo and ex vivo.
- 14 January 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 18
Open AccessA review of methods to measure tendon dimensions
Tendons are soft tissues of the musculoskeletal system that are designed to facilitate joint movement. Tendons exhibit a wide range of mechanical properties matched to their functions and, as a result, have been of interest to researchers for many decades. Dimensions are an important aspect of tendon properties. Change in the dimensions of tissues is often seen as a sign of injury and degeneration, as it may suggest inflammation or general disorder of the tissue. Dimensions are also important for determining the mechanical properties and behaviours of materials, particularly the stress, strain, and elastic modulus. This makes the dimensions significant in the context of a mechanical study of degenerated tendons. Additionally, tendon dimensions are useful in planning harvesting for tendon transfer and joint reconstruction purposes. Historically, many methods have been used in an attempt to accurately measure the dimensions of soft tissue, since improper measurement can lead to large errors in the calculated properties. These methods can be categorised as destructive (by approximation), contact, and non-contact and can be considered in terms of in vivo and ex vivo.
- 1 June 2018
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 29 (4) , 839-842
Single-Piece Titanium Plate Cranioplasty Reconstruction of Complex Defects
Background: Different methods have been described for the reconstruction of cranial defects and orbital defects. The complex contouring between the orbital roof and frontal bone creates significant design challenges for prefabricated cranio-orbital reconstructions. In describing the first reported patient of combined skull and orbital roof reconstruction with a single-piece titanium plate cranioplasty, the authors present a new method of combined complex cranio-orbital reconstruction. Methods: A 63-year-old lady presented with a large, right-sided frontal en–plaque meningioma involving the right orbit and sphenoid wing. Complete resection would require reconstruction of both the skull and the orbital roof. Surgical preplanning involved marking resection margins on a three-dimensional (3D) printed acrylonitrile-butadiene-styrene model. This margin was used to virtually resect the tumor and generate a repaired surface. A titanium plate was then fabricated using hydrostatic pressing into a 3D-printed mold and the orbital roof portion (a reentrant surface) was hand-finished. Lateral canthus and temporalis muscle suspension holes were prefabricated into the cranioplasty plate. Results: The patient underwent hemicraniectomy and tumor resection guided by a custom-made 3D-printed cutting guide. The surgical defect was reconstructed with the prefabricated titanium plate achieving a good functional and cosmetic result. Conclusion: Single-piece titanium plate cranioplasty is an effective novel reconstruction method for complex cranio-orbital defects.
- 1 June 2018
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 29 (4) , 839-842
Single-Piece Titanium Plate Cranioplasty Reconstruction of Complex Defects
Background: Different methods have been described for the reconstruction of cranial defects and orbital defects. The complex contouring between the orbital roof and frontal bone creates significant design challenges for prefabricated cranio-orbital reconstructions. In describing the first reported patient of combined skull and orbital roof reconstruction with a single-piece titanium plate cranioplasty, the authors present a new method of combined complex cranio-orbital reconstruction. Methods: A 63-year-old lady presented with a large, right-sided frontal en–plaque meningioma involving the right orbit and sphenoid wing. Complete resection would require reconstruction of both the skull and the orbital roof. Surgical preplanning involved marking resection margins on a three-dimensional (3D) printed acrylonitrile-butadiene-styrene model. This margin was used to virtually resect the tumor and generate a repaired surface. A titanium plate was then fabricated using hydrostatic pressing into a 3D-printed mold and the orbital roof portion (a reentrant surface) was hand-finished. Lateral canthus and temporalis muscle suspension holes were prefabricated into the cranioplasty plate. Results: The patient underwent hemicraniectomy and tumor resection guided by a custom-made 3D-printed cutting guide. The surgical defect was reconstructed with the prefabricated titanium plate achieving a good functional and cosmetic result. Conclusion: Single-piece titanium plate cranioplasty is an effective novel reconstruction method for complex cranio-orbital defects.
- 1 February 2018
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 31 (02) , 131-136
The Effect of Tibial Plateau Levelling Osteotomy on Stifle Extensor Mechanism Load: A Canine Ex Vivo Study
Objective To evaluate the effect of tibial plateau levelling osteotomy on stifle extensor mechanism load in an ex vivo cruciate-intact canine cadaveric model. Study Design Ex vivo mechanical testing study. Animals Cadaveric canine pelvic limbs (n = 6). Materials and Methods A 21-mm tibial radial osteotomy was performed on pelvic limbs (n = 6) prior to being mounted into a load-bearing limb press. The proximal tibial segment was incrementally rotated until the anatomical tibial plateau angle had been rotated to at least 1°. The proportional change in stifle extensor mechanism load between the anatomical tibial plateau angle and the neutralized (∼6.5 degrees) and over-rotated (∼1°) tibial plateau angle was analysed using a one-sample t-test against a null hypothesis of no change. A p-value ≤0.05 was considered significant. Results There was no significant change in the stifle extensor mechanism load from the anatomical tibial plateau angle (308 N [261–355 N]) to the neutralized tibial plateau angle (313 N [254–372 N]; p =.81), or from the anatomical tibial plateau angle to the over-rotated tibial plateau angle (303 N [254–352 N; p = 0.67). Conclusion Tibial plateau levelling osteotomy does not significantly alter stifle extensor mechanism load at either a neutralized or over-rotated tibial plateau angle in our cruciate-intact model. All authors contributed to the study conception, the study design, the acquisition of data, data analysis and interpretation, drafting or revising of the manuscript, and approved the submitted manuscript.
- 1 February 2018
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 31 (02) , 131-136
The Effect of Tibial Plateau Levelling Osteotomy on Stifle Extensor Mechanism Load: A Canine Ex Vivo Study
Objective To evaluate the effect of tibial plateau levelling osteotomy on stifle extensor mechanism load in an ex vivo cruciate-intact canine cadaveric model. Study Design Ex vivo mechanical testing study. Animals Cadaveric canine pelvic limbs (n = 6). Materials and Methods A 21-mm tibial radial osteotomy was performed on pelvic limbs (n = 6) prior to being mounted into a load-bearing limb press. The proximal tibial segment was incrementally rotated until the anatomical tibial plateau angle had been rotated to at least 1°. The proportional change in stifle extensor mechanism load between the anatomical tibial plateau angle and the neutralized (∼6.5 degrees) and over-rotated (∼1°) tibial plateau angle was analysed using a one-sample t-test against a null hypothesis of no change. A p-value ≤0.05 was considered significant. Results There was no significant change in the stifle extensor mechanism load from the anatomical tibial plateau angle (308 N [261–355 N]) to the neutralized tibial plateau angle (313 N [254–372 N]; p =.81), or from the anatomical tibial plateau angle to the over-rotated tibial plateau angle (303 N [254–352 N; p = 0.67). Conclusion Tibial plateau levelling osteotomy does not significantly alter stifle extensor mechanism load at either a neutralized or over-rotated tibial plateau angle in our cruciate-intact model. All authors contributed to the study conception, the study design, the acquisition of data, data analysis and interpretation, drafting or revising of the manuscript, and approved the submitted manuscript.
- 1 November 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (15) , 3753-3758
Structured white light scanning of rabbit Achilles tendon
- 1 November 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (15) , 3753-3758
Structured white light scanning of rabbit Achilles tendon
- Open Access
- 8 June 2016
- Published by Elsevier in Oral and Maxillofacial Surgery Cases
- Vol. 2 (2) , 19-21
A novel individual reconstruction of a medial orbital wall blow-out fracture using a bone graft molded intraoperatively using a 3-D model: a case report
- 8 June 2016
- Published by Elsevier in Oral and Maxillofacial Surgery Cases
- Vol. 2 (2) , 19-21
Open AccessA novel individual reconstruction of a medial orbital wall blow-out fracture using a bone graft molded intraoperatively using a 3-D model: a case report