Jose Saldana has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simplemux traffic optimization protocol

    by Jose Saldana

  • Open Access

    Real-Time AI-Based Data Prioritization for MODBUS TCP Communication in IoT-Enabled LVDC Energy Systems

    by Francisco J. Arroyo-Valle, Sandra Roger, Jose Saldana

    This paper presents an intelligent communication architecture, designed to manage multiple power devices operating within a shared Low-Voltage Direct Current (LVDC) bus. These devices act either as energy consumers, e.g., Electric Vehicle (EV) chargers, Power Distribution Units (PDUs), or as sources and regulators, e.g., Alternating Current-to-Direct Current (AC/DC) converters, energy storage system (ESS) units. Communication is established using industrial protocols such as Modular Digital Bus (MODBUS) over Transmission Control Protocol (TCP) or Remote Terminal Unit (RTU), and Controller Area Network (CAN). The proposed system supports both data acquisition and configuration of field devices. It exposes their information to an Energy Management System (EMS) via a MODBUS TCP server. A key contribution of this work is the integration of a lightweight Machine Learning (ML)-based data prioritization mechanism that dynamically adjusts the update frequency of each MODBUS parameter based on its current relevance. This ML-based method has been prototyped and evaluated within a virtualized Internet of Things (IoT) gateway environment. It enables real-time, efficient, and scalable communication without altering the EMS or disrupting legacy protocol operations. Furthermore, the proposed approach allows for early testing and validation of the prioritization strategy before full hardware integration in the demonstrators planned as part of the SHIFT2DC project under the Horizon Europe program.


  • Enhancing the Operation of the Hellenic Transmission System Through Wide-Area Monitoring and Control: Design, Implementation, and Evaluation of a Phasor Measurement Unit-Based System With Advanced Algorithms

    by Konstantinos F. Krommydas, Christos-Spyridon G. Karavas, Konstantinos A. Plakas, Efthimia Chassioti, Ioannis Moraitis, Anibal Antonio Prada Hurtado, Jose Saldana, Eduardo Martinez Carrasco, Virgilio De Andrade, Dalibor Brnobic

    The escalating occurrences of transmission congestions, overvoltages, undervoltages, power oscillations, and frequency abnormalities in transmission systems underline the need for a comprehensive review and enhancement of traditional management and operation tools and for the creation of new ones able to obtain real-time data from the field for analysis and operation. Jointly with an improvement of the dynamic models of the power grid, this will result in a better understanding of the system behavior especially in critical situations.


  • Open Access

    A dataset to train intrusion detection systems based on machine learning models for electrical substations

    by Esteban Damián Gutiérrez Mlot, Jose Saldana, Ricardo J. Rodríguez, Igor Kotsiuba, Carlos Gañán


  • Open Access

    Firmware Updates over the Air via LoRa: Unicast and Broadcast Combination for Boosting Update Speed

    by Victor Malumbres, Jose Saldana, Gonzalo Berné, Julio Modrego

    The capacity to update firmware is a vital component in the lifecycle of Internet of Things (IoT) devices, even those with restricted hardware resources. This paper explores the best way to wirelessly (Over The Air, OTA) update low-end IoT nodes with difficult access, combining the use of unicast and broadcast communications. The devices under consideration correspond to a recent industrial IoT project that focuses on the installation of intelligent lighting systems within ATEX (potentially explosive atmospheres) zones, connected via LoRa to a gateway. As energy consumption is not limited in this use case, the main figure of merit is the total time required for updating a project. Therefore, the objective is to deliver all the fragments of the firmware to each and all the nodes in a safe way, in the least amount of time. Three different methods, combining unicast and broadcast transmissions in different ways, are explored analytically, with the aim of obtaining the expected update time. The methods are also tested via extensive simulations, modifying different parameters such as the size of the scenario, the number of bytes of each firmware chunk, the number of nodes, and the number of initial broadcast rounds. The simulations show that the update time of a project can be significant, considering the limitations posed by regulations, in terms of the percentage of airtime consumption. However, significant time reductions can be achieved by using the proper method: in some cases, when the number of nodes is high, the update time can be reduced by two orders of magnitude if the correct method is chosen. Moreover, one of the proposed methods is implemented using actual hardware. This real implementation is used to perform firmware update experiments in a lab environment. Overall, the article illustrates the advantage of broadcast approaches in this kind of technology, in which the transmission rate is constant despite the distance between the gateway and the node. However, the advantage of these broadcast methods with respect to the unicast one could be mitigated if the nodes do not run exactly the same firmware version, since the control of the broadcast update would be more difficult and the total update time would increase.


  • Lossless and Stateless Compression of IEC 61850 Sampled Values Flows

    by Jose Saldana, Miguel A Oliván

    This letter proposes a lossless and stateless compression method for IEC 61850 Sampled Values flows. A set of bitmaps is introduced to indicate the size in bytes of the sampled currents and voltages, and to flag the presence or absence of the Quality field. The method has been evaluated for different profiles, and it can provide bandwidth savings between 30 and 52%, with a very low computational cost as a counterpart. It has been implemented and tested in two different hardware platforms, with traffic generated by a Merging Unit. The processing delays have been found to be acceptable, showing a good tradeoff between compression rate, complexity and added delay.


  • Open Access

    Fast and Reliable Sending of Generic Object Oriented Substation Event Frames between Remote Locations over Loss-Prone Networks

    by Jose Saldana, Aníbal Antonio Prada Hurtado, Eduardo Martinez Carrasco, Yasmina Galve, Jesús Torres

    WAMPAC (Wide Area Monitoring Protection and Control) applications are becoming crucial for granting a stable operation of the electricity transmission grid. These systems use a set of sensors distributed between different electrical substations to gather real-time measurements from the field. These sensors are called Phasor Measurement Units (PMUs). Using the gathered data, different monitoring, protection, and control algorithms are run in a Phasor Data Concentrator (PDC) located in a central location. These algorithms close the loop via the generation of remedial commands, which are sent back to the field level with stringent delay, security, and reliability requirements. GOOSE (Generic Object Oriented Substation Events) protocol, defined by IEC 61850 (IEC stands for International Electrotechnical Commission), is used for that aim and also considers the option of sending these commands over IP networks (this option is called Routed-GOOSE). The present article proposes two alternatives for the tunneling of GOOSE frames over IP. Both options allow the decoupling of the transmission and the security aspects, thus increasing flexibility and allowing for easier deployment. The first option, called VX-GOOSE, is a combination of standard protocols, allowing the sending of these frames over UDP/IP tunnels. The tests that have been carried out demonstrate that, under certain network conditions, the transmission of GOOSE frames over UDP may fail, and in some extreme cases, even a whole burst of GOOSEs could be lost. This may have very bad consequences for a distributed electrical system. It should be noted that this limitation affects both VX-GOOSE and Routed-GOOSE. To overcome these limitations, the second option, called Simplemux blast mode, includes a novel mechanism that provides delivery guarantees and a reduced delay, with the counterpart of a certain degree of redundancy. As shown in the experiments, the incurred delays can be significantly reduced when remote locations are connected via unreliable networks, whereas the bandwidth increase caused by redundancy can be kept at reasonable levels. Finally, it should be remarked that although GOOSE is a relevant example use case, this approach can be applied in other fields where flows require very low delay and delivery guarantees.


  • Open Access

    Detection and Classification of Fault Types in Distribution Lines by Applying Contrastive Learning to GAN Encoded Time-Series of Pulse Reflectometry Signals

    by Javier Granado Fornas, Elias Herrero Jaraba, Andres Llombart Estopinan, Jose Saldana

    This study proposes a new method for detecting and classifying faults in distribution lines. The physical principle of classification is based on time-domain pulse reflectometry (TDR). These high-frequency pulses are injected into the line, propagate through all of its bifurcations, and are reflected back to the injection point. According to the impedances encountered along the way, these signals carry information regarding the state of the line. In the present work, an initial signal database was obtained using the TDR technique, simulating a real distribution line using (PSCAD™). By transforming these signals into images and reducing their dimensionality, these signals are processed using convolutional neural networks (CNN). In particular, in this study, contrastive learning in Siamese networks was used for the classification of different types of faults (ToF). In addition, to avoid the problem of overfitting owing to the scarcity of examples, generative adversarial neural networks (GAN) have been used to synthesise new examples, enlarging the initial database. The combination of Siamese neural networks and GAN allows the classification of this type of signal using only synthesised examples to train and validate and only the original examples to test the network. This solves the problem of the lack of original examples in this type of signal of natural phenomena which are difficult to obtain and simulate.


  • Open Access

    Application of IIA Method and Virtual Bus Theory for Backup Protection of a Zone Using PMU Data in a WAMPAC System

    by Aníbal Antonio Prada Hurtado, Eduardo Martinez Carrasco, Maria Teresa Villén Martínez, Jose Saldana

    Many wide area monitoring, protection, and control (WAMPAC) systems are being deployed by grid operators to deal with critical operational conditions that may occur in power systems. Thanks to the real-time measurements provided by a set of distributed phasor measurement units (PMUs), different protection algorithms can be run in a central location. In this context, this article presents and validates a novel method that can be used as a backup protection for a selected area in a power system. It merges the integrated impedance angle (IIA) protection method with the theory of virtual buses in wide area electrical power systems. The backup protection works this way: once a fault is detected (pickup time), another delay (added to the pickup time) is defined in order to wait for the primary protection to act. If this does not happen, the algorithm generates its backup trip. The proposed method has been called the zone integrated impedance angle (Zone IIA). A real-time PMU laboratory has been used to test the proposed algorithm using a real-time digital simulator (RTDS). The algorithm has been programmed in a real-time automation controller (RTAC). It has been tested in two different simulated setups: first, a 400 kV transmission system, with and without the use of renewable energy sources (RES); second, a 150 kV submarine line between the Greece mainland and an island, which is currently the longest submarine alternating current connection in the world. The results obtained during the tests have yielded tripping times for area protection in the order of 48 ms, if no time delay is used between the fault detection and the trip order. According to the test results, the proposed method is stable, reliable, obedient, and secure, also with RES installed in the power system. Additionally, the method is selective, i.e., during the tests no trip was executed for external faults, no trip was executed in no-fault condition, and all the applied internal faults were detected and tripped correctly. Finally, the protection method is easy to implement. The method is also applicable to protection against short circuits in distribution systems. According to the trip times observed during the tests, it is clear that these algorithms are well suited to implement backup protections in transmission grids, even in scenarios with high penetration of renewable energies. Considering that backup trip times in transmission grids are usually set between 400 and 1000 ms, and that the actuation times obtained by the proposed algorithm are under 100 ms, the method is suitable for its use as a backup protection.


  • Open Access

    Attention to Wi-Fi Diversity: Resource Management in WLANs With Heterogeneous APs

    by Jose Saldana, Jose Ruiz-Mas, Julian Fernandez-Navajas, Jose Luis Salazar Riano, Jean-Philippe Javaudin, Jean-Michel Bonnamy, Mael Le Dizes

    Many home networks integrate a small number (typically 2-4) of Wi-Fi Access Points (APs), with heterogeneous characteristics: different 802.11 variants, capabilities and security schemes. This paper proposes the consideration of these specific characteristics in order to improve the management of network resources. Three use cases are presented in order to showcase the potential benefits. By the use of a user-space AP, which works in coordination with a controller, the network is able to assign each connected station to the AP that best fits with its characteristics. The system also manages security, avoiding the need of adding specific elements for authentication, encryption or decryption. Extensions are proposed to an existing protocol that defines the communication between the AP and the controller, in order to communicate and store the specific characteristics of each AP and end device. This includes new association and handoff schemes that do not introduce any additional delay. The system has been implemented in a real environment, and a battery of tests has been run using three hardware platforms of different characteristics. The results show that handoffs between bands are possible, and estimate the processing delays, the Round-Trip Time and the handoff delay, which is small enough in order not to produce any significant disruption to the user (10-50 ms). Finally, the scenarios of interest have been replicated in a simulation environment, showing that significant benefits can be achieved if the specific characteristics of each AP and station are considered.