Eduard Khutoryan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eduard Khutoryan has a total of 179 co-authors. Here are the top co-authors by number of shared publications:
- Sergey Ponomarenko
Max Planck Institute for Plasma Physics, Greifswald, Germany
26 shared publications - Alexei N. Kuleshov
O. Ya. Usikov Institute for Radio Physics and Electronics, National Academy of Sciences of Ukraine, Kharkiv, Ukraine
24 shared publications - Sergey A. Kishko
O. Ya. Usikov Institute for Radio, Physics and Electronics of NASU,Department of Vacuum Electronics,Kharkiv,Ukraine
22 shared publications - Yurii S. Kovshov
O.Ya. Usikov Institute for Radiophysics and Electronics of the National Academy of Sciences of Ukraine 12, Academician Proskura St., Kharkiv 61085, Ukraine
14 shared publications Toshitaka Idehara
Research Center for Development of Far-Infrared Region, University of Fukui, Fukui, Japan
9 shared publications- Yoshinori Tatematsu
Research Center for Development of Far-Infrared Region, University of Fukui, Fukui, Japan
7 shared publications
Latest Publications
- Open Access
- 10 June 2026
- Published by V. N. Karazin Kharkiv National University in East European Journal of Physics
- No. 2,p. 528-540
Formation of an Axially Symmetric Field Distribution Using Rectangular Aperture Radiators
Using the aperture method, radiation from the open end of a rectangular waveguide was studied. Expressions were derived to describe the radiation pattern of such an aperture in the far-field region in two mutually perpendicular planes. Numerical studies of the radiation pattern cross-sections in the image plane were performed for two rectangular apertures, 40×33 mm and 30×21.6 mm, with varying aperture widths and heights. A comparison of the obtained radiation pattern cross-sections with a Gaussian field distribution showed that up to the –11 dB level, the radiation pattern cross-sections in both image planes practically coincide with the Gaussian field distribution. This result is particularly important when a wave beam is incident on the flat face of an axicon. It was also shown that varying the smaller dimension of the rectangular aperture can yield an axially symmetric radiation pattern. Experimental studies of these apertures in the Ka band were conducted. Good agreement between the experimental results and theoretical calculations was demonstrated. It was found that when the geometric dimensions of the rectangular aperture exceed two wavelengths, a traveling-wave regime is established in the waveguide section. Experimentally, it was found that the amplitude distribution of the field for both apertures in the far-field region coincides with the Gaussian distribution down to –8.7 dB. It was shown that the use of rectangular apertures to illuminate the flat face of an axicon with a wave beam is impractical.
- 10 June 2026
- Published by V. N. Karazin Kharkiv National University in East European Journal of Physics
- No. 2,p. 528-540
Open AccessFormation of an Axially Symmetric Field Distribution Using Rectangular Aperture Radiators
Using the aperture method, radiation from the open end of a rectangular waveguide was studied. Expressions were derived to describe the radiation pattern of such an aperture in the far-field region in two mutually perpendicular planes. Numerical studies of the radiation pattern cross-sections in the image plane were performed for two rectangular apertures, 40×33 mm and 30×21.6 mm, with varying aperture widths and heights. A comparison of the obtained radiation pattern cross-sections with a Gaussian field distribution showed that up to the –11 dB level, the radiation pattern cross-sections in both image planes practically coincide with the Gaussian field distribution. This result is particularly important when a wave beam is incident on the flat face of an axicon. It was also shown that varying the smaller dimension of the rectangular aperture can yield an axially symmetric radiation pattern. Experimental studies of these apertures in the Ka band were conducted. Good agreement between the experimental results and theoretical calculations was demonstrated. It was found that when the geometric dimensions of the rectangular aperture exceed two wavelengths, a traveling-wave regime is established in the waveguide section. Experimentally, it was found that the amplitude distribution of the field for both apertures in the far-field region coincides with the Gaussian distribution down to –8.7 dB. It was shown that the use of rectangular apertures to illuminate the flat face of an axicon with a wave beam is impractical.
- 21 April 2026
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 47 (5) , 29
Highly Selective Two-Mirror Open Resonators Containing a Circular Cavity
- 21 April 2026
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 47 (5) , 29
Highly Selective Two-Mirror Open Resonators Containing a Circular Cavity
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (8) , 1-7
Electronic Frequency Tuning in the 330-GHz CW Clinotron Oscillator With Modified Cavity
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (8) , 1-7
Electronic Frequency Tuning in the 330-GHz CW Clinotron Oscillator With Modified Cavity
- 15 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Output Performance of the 330 GHz CW Clinotron with a Modified Cavity
Experimental results of a 330 GHz CW clinotron with a modified cavity are presented. These results are compared with the cold-cavity simulation results that take into account mode reflection and conversion at both the collector and the output ends of the cavity. During the analysis of output characteristics of the clinotron, special attention was paid to the excitation of the high-order surface modes in the beam-wave interaction region, which significantly enhances the electronic frequency-tuning range. The efficiency of mode excitation and conversions was analyzed in the frequency range of 280- 335 GHz, while the width of both the oversized the interaction space and the output waveguide were designed to provide singlemode output radiation.
- 15 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Output Performance of the 330 GHz CW Clinotron with a Modified Cavity
Experimental results of a 330 GHz CW clinotron with a modified cavity are presented. These results are compared with the cold-cavity simulation results that take into account mode reflection and conversion at both the collector and the output ends of the cavity. During the analysis of output characteristics of the clinotron, special attention was paid to the excitation of the high-order surface modes in the beam-wave interaction region, which significantly enhances the electronic frequency-tuning range. The efficiency of mode excitation and conversions was analyzed in the frequency range of 280- 335 GHz, while the width of both the oversized the interaction space and the output waveguide were designed to provide singlemode output radiation.
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (3) , 1383-1389
Coupling of Spoof Surface Plasmon Polariton With Multiple-Order Smith–Purcell Radiation in THz Cherenkov Oscillator
We propose a novel concept of a Cherenkov vacuum electron device (VED) based on the coupling of leaky-wave spoof surface plasmon polaritons (LW SSPPs) with multiple-order Smith–Purcell radiation (SPR) in a circuit with a biperiodic double grating (DG) for electromagnetic radiation generation in the THz range. We show that both effective feedback and a radiation output are realized when the order of SPR in a dielectric slab is used for a feedback loop while the order of SPR into a free space serves as a radiation output. The employed biperiodic DG provides a strong coupling of the SPR with the LW SSPP in a wide bandwidth as well as an enhanced beam–wave coupling impedance. The carried-out particle-in-cell simulations demonstrate significant increase of output efficiency of up to 3% as well as expansion of frequency tunning range up to 20% (0.53–0.64 THz).
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (3) , 1383-1389
Coupling of Spoof Surface Plasmon Polariton With Multiple-Order Smith–Purcell Radiation in THz Cherenkov Oscillator
We propose a novel concept of a Cherenkov vacuum electron device (VED) based on the coupling of leaky-wave spoof surface plasmon polaritons (LW SSPPs) with multiple-order Smith–Purcell radiation (SPR) in a circuit with a biperiodic double grating (DG) for electromagnetic radiation generation in the THz range. We show that both effective feedback and a radiation output are realized when the order of SPR in a dielectric slab is used for a feedback loop while the order of SPR into a free space serves as a radiation output. The employed biperiodic DG provides a strong coupling of the SPR with the LW SSPP in a wide bandwidth as well as an enhanced beam–wave coupling impedance. The carried-out particle-in-cell simulations demonstrate significant increase of output efficiency of up to 3% as well as expansion of frequency tunning range up to 20% (0.53–0.64 THz).
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 71 (6) , 3940-3944
Radiation Output of the 330 GHz Continuous-Wave Clinotron Oscillator With Modified Cavity
The design of the 330 GHz continuous-wave clinotron oscillator with the modified circuit is presented together with the simulation results of the cold cavity including the circuit coupled to the power output. The simulations revealed the effective broadband conversion of the surface wave excited by the sheet electron beam moving above the grating to the TE10 mode of the oversized output waveguide. The experimental studies of the clinotron oscillator demonstrated the operating frequency range from 280 to 335 GHz and the output power up to 110 mW. Finally, both simulation and experimental results revealed the excitation of the surface wave with one node of E-component along the grating lamella width that effectively transfers to TE20 mode of the waveguide output.
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 71 (6) , 3940-3944
Radiation Output of the 330 GHz Continuous-Wave Clinotron Oscillator With Modified Cavity
The design of the 330 GHz continuous-wave clinotron oscillator with the modified circuit is presented together with the simulation results of the cold cavity including the circuit coupled to the power output. The simulations revealed the effective broadband conversion of the surface wave excited by the sheet electron beam moving above the grating to the TE10 mode of the oversized output waveguide. The experimental studies of the clinotron oscillator demonstrated the operating frequency range from 280 to 335 GHz and the output power up to 110 mW. Finally, both simulation and experimental results revealed the excitation of the surface wave with one node of E-component along the grating lamella width that effectively transfers to TE20 mode of the waveguide output.