Anna Karion
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Anna Karion has a total of 322 co-authors. Here are the top co-authors by number of shared publications:
- Colm Sweeney
National Oceanic and Atmospheric Administration Global Monitoring Laboratory (NOAA/GML), 325 Broadway R/GML, Boulder, CO 80305, USA
27 shared publications - James Whetstone
National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA
20 shared publications - Kimberly Mueller
National Institute of Standards and Technology Gaithersburg MD USA
17 shared publications - Israel Lopez-Coto
National Institute of Standards and Technology Gaithersburg MD USA
13 shared publications - John Bharat Miller
Global Monitoring Laboratory, National Oceanic and Atmospheric Administration, Boulder, CO, USA
12 shared publications Israel Lopez-Coto
11 shared publications
Latest Publications
- Open Access
- 12 August 2026
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 131 (16)
Development and Evaluation of an Urban Atmospheric Inverse Modeling Framework for the Washington, DC and Baltimore, MD Metropolitan Area: Initial Results From an Inert Tracer Case Study
Accurate quantification of hazardous material releases in cities is critical for emergency managers aiming to mitigate health impacts and mortality in the population. Here, a study on the development and evaluation of a high‐resolution (1‐km, 1‐hr) urban‐scale atmospheric inverse modeling system for the Washington, DC, and Baltimore, MD, metropolitan area (DCBA) is presented to advance surface flux quantification in urban and industrial areas where the potential for a hazardous release is high. The system employs an inert tracer as a proof of concept for January 2019 and builds upon HYSPLIT atmospheric transport and dispersion simulations driven by high‐resolution Weather Research and Forecasting (WRF) model simulations that ingest urban meteorological observations, coupled with the CarbonTracker‐Lagrange (CT‐L) inverse model tailored to account for hourly spatiotemporal fluxes. The system assimilates tower‐based tracer observations from the National Institute of Standards and Technology (NIST) Northeast Corridor Urban Test Bed and utilizes the 1‐km Vulcan and 4‐km GRA2PES bottom‐up inventories as prior knowledge of the tracer fluxes. Numerical experiments using synthetic and actual data reveal that the system significantly improves the quantification of flux strength (mean flux) and total mass released across the urban cores of Washington, DC, and Baltimore, MD. Hourly flux variations are fairly well resolved when originating from a broad territory (city scale), while the accuracy of source retrieval improves when flux estimates are aggregated to coarser spatial resolutions (e.g., 4 km). This work has important implications for estimating hazardous releases from urban areas for emergency response and hazard analysis.
- 12 August 2026
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 131 (16)
Open AccessDevelopment and Evaluation of an Urban Atmospheric Inverse Modeling Framework for the Washington, DC and Baltimore, MD Metropolitan Area: Initial Results From an Inert Tracer Case Study
Accurate quantification of hazardous material releases in cities is critical for emergency managers aiming to mitigate health impacts and mortality in the population. Here, a study on the development and evaluation of a high‐resolution (1‐km, 1‐hr) urban‐scale atmospheric inverse modeling system for the Washington, DC, and Baltimore, MD, metropolitan area (DCBA) is presented to advance surface flux quantification in urban and industrial areas where the potential for a hazardous release is high. The system employs an inert tracer as a proof of concept for January 2019 and builds upon HYSPLIT atmospheric transport and dispersion simulations driven by high‐resolution Weather Research and Forecasting (WRF) model simulations that ingest urban meteorological observations, coupled with the CarbonTracker‐Lagrange (CT‐L) inverse model tailored to account for hourly spatiotemporal fluxes. The system assimilates tower‐based tracer observations from the National Institute of Standards and Technology (NIST) Northeast Corridor Urban Test Bed and utilizes the 1‐km Vulcan and 4‐km GRA2PES bottom‐up inventories as prior knowledge of the tracer fluxes. Numerical experiments using synthetic and actual data reveal that the system significantly improves the quantification of flux strength (mean flux) and total mass released across the urban cores of Washington, DC, and Baltimore, MD. Hourly flux variations are fairly well resolved when originating from a broad territory (city scale), while the accuracy of source retrieval improves when flux estimates are aggregated to coarser spatial resolutions (e.g., 4 km). This work has important implications for estimating hazardous releases from urban areas for emergency response and hazard analysis.
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Urban Atmospheric Monitoring and Modeling System (Urban-AMMS): A Top-Down Approach to Investigate Sources and Variability of an Inert Tracer in the Washington, DC, and Baltimore, MD, Metropolitan Area
Accurate quantification of the sources and sinks of long-lived air pollutants is fundamental for effective emissions management, particularly in urban areas where emissions are generally more intense. Stakeholders commonly use so-called bottom-up methods to estimate emissions for urban areas. This type of emission accounting is typically carried out for annual totals, often with a latency of one or more years. Alternative methods that provide estimates with higher temporal resolution and lower latency could be helpful for stakeholders seeking targeted strategies to reduce emissions. A top-down urban emissions estimation system for the Washington, DC, and Baltimore, MD, metropolitan area, called the Urban Atmospheric Monitoring and Modeling System (Urban-AMMS), is being developed to provide accurate, up-to-date urban emissions data. Urban-AMMS has several components, including tower-based, aircraft, and mobile van measurements platforms, whose data are assimilated by the CarbonTracker-Lagrange analytical inverse model; an ensemble of HYSPLIT backward dispersion simulations driven by in-house high-resolution WRF simulations (spatial resolution of 1 km) enhanced with urban meteorological observations; biospheric models; and bottom-up inventories used for a prior estimate of emissions in the domain. The inversion system is tailored to account for the underlying variability in urban fluxes of an inert tracer (CO2) by solving for hourly fluxes and incorporating explicit spatiotemporal covariance of prior errors, as well as high-resolution source-receptor sensitivities estimated by WRF-HYSPLIT. Here, we present an overview of Urban-AMMS, including initial results and sensitivity analyses to investigate the effects of prior spatial aggregation, background handling, and the temporal covariance of prior errors. Numerical experiments show improvements in estimates of urban surface fluxes at both the city and grid cell scales. Still, the reliability of inverse fluxes depends on prior uncertainty, as observed in previous studies. These findings provide critical insights for the inverse estimation of long-lived air pollutants in complex urban environments.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessUrban Atmospheric Monitoring and Modeling System (Urban-AMMS): A Top-Down Approach to Investigate Sources and Variability of an Inert Tracer in the Washington, DC, and Baltimore, MD, Metropolitan Area
Accurate quantification of the sources and sinks of long-lived air pollutants is fundamental for effective emissions management, particularly in urban areas where emissions are generally more intense. Stakeholders commonly use so-called bottom-up methods to estimate emissions for urban areas. This type of emission accounting is typically carried out for annual totals, often with a latency of one or more years. Alternative methods that provide estimates with higher temporal resolution and lower latency could be helpful for stakeholders seeking targeted strategies to reduce emissions. A top-down urban emissions estimation system for the Washington, DC, and Baltimore, MD, metropolitan area, called the Urban Atmospheric Monitoring and Modeling System (Urban-AMMS), is being developed to provide accurate, up-to-date urban emissions data. Urban-AMMS has several components, including tower-based, aircraft, and mobile van measurements platforms, whose data are assimilated by the CarbonTracker-Lagrange analytical inverse model; an ensemble of HYSPLIT backward dispersion simulations driven by in-house high-resolution WRF simulations (spatial resolution of 1 km) enhanced with urban meteorological observations; biospheric models; and bottom-up inventories used for a prior estimate of emissions in the domain. The inversion system is tailored to account for the underlying variability in urban fluxes of an inert tracer (CO2) by solving for hourly fluxes and incorporating explicit spatiotemporal covariance of prior errors, as well as high-resolution source-receptor sensitivities estimated by WRF-HYSPLIT. Here, we present an overview of Urban-AMMS, including initial results and sensitivity analyses to investigate the effects of prior spatial aggregation, background handling, and the temporal covariance of prior errors. Numerical experiments show improvements in estimates of urban surface fluxes at both the city and grid cell scales. Still, the reliability of inverse fluxes depends on prior uncertainty, as observed in previous studies. These findings provide critical insights for the inverse estimation of long-lived air pollutants in complex urban environments.
- Open Access
- 9 July 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (28) , 14399-14409
Scaling Urban Methane Emissions: Utility of Single-Site Measurements in Five Urban Domains
Urban methane (CH4) missions remain poorly understood due to limited observational constraints. Most estimates rely on bottom-up inventories based on assumed emission factors and activity data or downscaling methods, which often underestimate emissions, sometimes by a factor of 2 or more in United States and European cities. While satellite and mobile observations can improve understanding, they face limitations in spatial resolution, coverage, and frequency. In contrast, fixed in situ measurements calibrated to World Meteorological Organization standards offer high precision continuous data, although with limited spatial coverage due to logistical constraints. This study uses in situ observations from single tower sites in five northeastern United States cities to estimate total urban CH4 emissions using a Bayesian scaling factor framework. Despite limited spatial sampling, the approach yields robust emission estimates consistent with other studies. To explore drivers of variability, the analysis examines correlations between inferred emissions and urban characteristics including population, residential gas usage, and infrastructure. Results show that residential building volume outperforms population as a predictor in some regions, highlighting the importance of infrastructure-specific factors. By demonstrating a scalable observation-based approach using minimal sites, this work addresses key gaps in urban CH4 monitoring and emphasizes the value of robust measurements and tailored proxies for improving emission estimates in diverse urban settings.
- 9 July 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (28) , 14399-14409
Open AccessScaling Urban Methane Emissions: Utility of Single-Site Measurements in Five Urban Domains
Urban methane (CH4) missions remain poorly understood due to limited observational constraints. Most estimates rely on bottom-up inventories based on assumed emission factors and activity data or downscaling methods, which often underestimate emissions, sometimes by a factor of 2 or more in United States and European cities. While satellite and mobile observations can improve understanding, they face limitations in spatial resolution, coverage, and frequency. In contrast, fixed in situ measurements calibrated to World Meteorological Organization standards offer high precision continuous data, although with limited spatial coverage due to logistical constraints. This study uses in situ observations from single tower sites in five northeastern United States cities to estimate total urban CH4 emissions using a Bayesian scaling factor framework. Despite limited spatial sampling, the approach yields robust emission estimates consistent with other studies. To explore drivers of variability, the analysis examines correlations between inferred emissions and urban characteristics including population, residential gas usage, and infrastructure. Results show that residential building volume outperforms population as a predictor in some regions, highlighting the importance of infrastructure-specific factors. By demonstrating a scalable observation-based approach using minimal sites, this work addresses key gaps in urban CH4 monitoring and emphasizes the value of robust measurements and tailored proxies for improving emission estimates in diverse urban settings.
- Open Access
- 18 March 2025
- Published by Copernicus GmbH
Enhancing Urban GHG Monitoring: Progress of the NIST test-bed system
As the U.S. Metrology Institute, the National Institute of Standards and Technology (NIST) has responded to the measurements and standards challenge of monitoring, reporting, and verifying greenhouse gas (GHG) emissions from a broad range of sources, with an emphasis on urban environments, to: a) improve U.S. capabilities to measure GHG emissions accurately; b) demonstrate the capabilities of atmospheric urban monitoring networks (top-down or atmospheric measurement approaches) to determine quantitatively GHG fluxes from industrial, residential, transportation, power generation and other activities; c) complement such measurements with spatially explicit emissions modeling (bottom-up or emissions modeling) approaches based on socio-economic data; and d) demonstrate that the combination improves confidence in emission estimates while identifying areas of improvement. As part of these efforts, NIST established its first Urban Test Bed in Indianapolis, Indiana (the INFLUX Project) in 2010 with Purdue University, NOAA, and Penn State University collaborators. Additional testbeds were established in Los Angeles (2012) and the Northeast Corridor (2014) to test applicability of methodologies over a range of meteorological conditions and emissions profiles. In this talk, we summarize some of the results obtained where we demonstrated methodologies for biogenic emission and uptake processes estimation, network design and emissions quantification from dense tower-networks and aircraft measurements. In addition, we highlight current efforts to transfer the research to operations, facilitate the adoption of the techniques by developing lower cost monitoring stations, and promote transparency by consolidating the methods in open-source computational tools.
- 18 March 2025
- Published by Copernicus GmbH
Open AccessEnhancing Urban GHG Monitoring: Progress of the NIST test-bed system
As the U.S. Metrology Institute, the National Institute of Standards and Technology (NIST) has responded to the measurements and standards challenge of monitoring, reporting, and verifying greenhouse gas (GHG) emissions from a broad range of sources, with an emphasis on urban environments, to: a) improve U.S. capabilities to measure GHG emissions accurately; b) demonstrate the capabilities of atmospheric urban monitoring networks (top-down or atmospheric measurement approaches) to determine quantitatively GHG fluxes from industrial, residential, transportation, power generation and other activities; c) complement such measurements with spatially explicit emissions modeling (bottom-up or emissions modeling) approaches based on socio-economic data; and d) demonstrate that the combination improves confidence in emission estimates while identifying areas of improvement. As part of these efforts, NIST established its first Urban Test Bed in Indianapolis, Indiana (the INFLUX Project) in 2010 with Purdue University, NOAA, and Penn State University collaborators. Additional testbeds were established in Los Angeles (2012) and the Northeast Corridor (2014) to test applicability of methodologies over a range of meteorological conditions and emissions profiles. In this talk, we summarize some of the results obtained where we demonstrated methodologies for biogenic emission and uptake processes estimation, network design and emissions quantification from dense tower-networks and aircraft measurements. In addition, we highlight current efforts to transfer the research to operations, facilitate the adoption of the techniques by developing lower cost monitoring stations, and promote transparency by consolidating the methods in open-source computational tools.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
The US global and regional observing and analysis systems strategies for monitoring and delivering GHG natural and anthropogenic emissions estimates
Direct and remote observations of ocean and atmospheric greenhouse gases (GHGs) provide a critical constraint on global atmospheric burden of GHGs as well as the key natural and anthropogenic processes that transfer GHGs between atmosphere and land and ocean reservoirs. The United States (US) has played a large role in providing observations that span global to local scale in both the ocean and the atmosphere relying on both direct measurements of the atmosphere and ocean from ground, tower, ship, balloon and aircraft-based platforms and remote measurements from satellite, upward looking spectrometers, floats and ocean profilers. While these networks have been instrumental in providing a basic understanding of the carbon cycle there are many gaps that need to be filled over the next decade to assess interannual variability in both natural and anthropogenic sources and sinks of GHGs. With no planned US satellite missions for carbon dioxide in this time period there is an urgent need to take advantage of other gap filling opportunities. For methane, the focus on large point sources for satellites also represents a gap that many assumed would be filled in the next decade. These gaps in planned remote sensing satellite missions reinforce the need to focus development of new planforms, networks and tracers for observing atmospheric and ocean GHGs gradients and processes driving these gradients. These processes include climate/carbon feedbacks as well as changes in anthropogenic emissions across multiple scales that allow stakeholders in pursuit of GHG mitigation and carbon capture efforts to be informed and act with the most up-to-date understanding of critical processes in the global and local carbon budgets. We provide an overview of the observing, analysis and information systems that build on "bottom up" systems that currently inform the Global Stocktake. We also will report on efforts to make this information more actionable for emissions mitigation.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessThe US global and regional observing and analysis systems strategies for monitoring and delivering GHG natural and anthropogenic emissions estimates
Direct and remote observations of ocean and atmospheric greenhouse gases (GHGs) provide a critical constraint on global atmospheric burden of GHGs as well as the key natural and anthropogenic processes that transfer GHGs between atmosphere and land and ocean reservoirs. The United States (US) has played a large role in providing observations that span global to local scale in both the ocean and the atmosphere relying on both direct measurements of the atmosphere and ocean from ground, tower, ship, balloon and aircraft-based platforms and remote measurements from satellite, upward looking spectrometers, floats and ocean profilers. While these networks have been instrumental in providing a basic understanding of the carbon cycle there are many gaps that need to be filled over the next decade to assess interannual variability in both natural and anthropogenic sources and sinks of GHGs. With no planned US satellite missions for carbon dioxide in this time period there is an urgent need to take advantage of other gap filling opportunities. For methane, the focus on large point sources for satellites also represents a gap that many assumed would be filled in the next decade. These gaps in planned remote sensing satellite missions reinforce the need to focus development of new planforms, networks and tracers for observing atmospheric and ocean GHGs gradients and processes driving these gradients. These processes include climate/carbon feedbacks as well as changes in anthropogenic emissions across multiple scales that allow stakeholders in pursuit of GHG mitigation and carbon capture efforts to be informed and act with the most up-to-date understanding of critical processes in the global and local carbon budgets. We provide an overview of the observing, analysis and information systems that build on "bottom up" systems that currently inform the Global Stocktake. We also will report on efforts to make this information more actionable for emissions mitigation.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Greenhouse gas and short-lived pollutants in the Baltimore, MD and Washington, DC area: Coordinated measurements and models
The cities of Baltimore, MD and Washington, DC generate substantial amounts of air pollutants with adverse effects on health and climate, but the magnitude and origins of these contaminants remain uncertain. The State of Maryland has committed to reducing statewide greenhouse gas emissions by 60% (relative to 2006 levels) by the year 2031. A team of scientists from the Maryland Department of the Environment (MDE), the National Institute of Standards and Technology (NIST), the National Oceanic and Atmospheric Administration (NOAA), the University of Maryland, and Stony Brook University have established a coordinated program of measurements and models to quantify and allocate emissions. These include observations from aircraft, a mobile laboratory, a tower array, and surface monitors as well as Lagrangian and Eulerian models. Results thus far indicate that methane emissions substantially exceed initial, traditional, bottom-up, inventory data and that leakage from the natural gas delivery system and landfills are major sources. Urban methane emissions show a strong seasonality, consistent with natural gas usage – the flux in winter was 44% greater than in summer. Model inversions suggest urban methane emissions in Washington and Baltimore decreased by 4-5%/yr between 2018 and 2021. Mobile laboratory measurements of GHGs and air pollutants such as black carbon with high temporal and spatial resolution reveal a variety of sources in densely populated urban residential areas related to traffic and industry and with implications for environmental justice. Analysis of long-term monitoring data with clustering of trajectories identified dominant transport pathways and sources in upwind states that likely contribute in a major way to ambient methane concentrations in the Baltimore/Washington area – these include the Marcellus oil and gas plays in Pennsylvania and West Virginia as well as swine production in North Carolina. Ongoing and future work includes developing a landfill as a testbed for emissions quantification and control and use of carbon and hydrogen isotopes to partition fossil and biogenic emissions and biogenic losses. The combination of State, federal, and university resources makes for a powerful tool to tackle air quality and climate problems.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessGreenhouse gas and short-lived pollutants in the Baltimore, MD and Washington, DC area: Coordinated measurements and models
The cities of Baltimore, MD and Washington, DC generate substantial amounts of air pollutants with adverse effects on health and climate, but the magnitude and origins of these contaminants remain uncertain. The State of Maryland has committed to reducing statewide greenhouse gas emissions by 60% (relative to 2006 levels) by the year 2031. A team of scientists from the Maryland Department of the Environment (MDE), the National Institute of Standards and Technology (NIST), the National Oceanic and Atmospheric Administration (NOAA), the University of Maryland, and Stony Brook University have established a coordinated program of measurements and models to quantify and allocate emissions. These include observations from aircraft, a mobile laboratory, a tower array, and surface monitors as well as Lagrangian and Eulerian models. Results thus far indicate that methane emissions substantially exceed initial, traditional, bottom-up, inventory data and that leakage from the natural gas delivery system and landfills are major sources. Urban methane emissions show a strong seasonality, consistent with natural gas usage – the flux in winter was 44% greater than in summer. Model inversions suggest urban methane emissions in Washington and Baltimore decreased by 4-5%/yr between 2018 and 2021. Mobile laboratory measurements of GHGs and air pollutants such as black carbon with high temporal and spatial resolution reveal a variety of sources in densely populated urban residential areas related to traffic and industry and with implications for environmental justice. Analysis of long-term monitoring data with clustering of trajectories identified dominant transport pathways and sources in upwind states that likely contribute in a major way to ambient methane concentrations in the Baltimore/Washington area – these include the Marcellus oil and gas plays in Pennsylvania and West Virginia as well as swine production in North Carolina. Ongoing and future work includes developing a landfill as a testbed for emissions quantification and control and use of carbon and hydrogen isotopes to partition fossil and biogenic emissions and biogenic losses. The combination of State, federal, and university resources makes for a powerful tool to tackle air quality and climate problems.
- Open Access
- 18 December 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (24) , 7065-7075
Methodology and uncertainty estimation for measurements of methane leakage in a manufactured house
Methane emissions from natural gas appliances and infrastructure within buildings have historically not been captured in greenhouse gas inventories, leading to under-estimates, especially in urban areas. Recent measurements of these post-meter emissions have indicated non-negligible emissions within residences, with impacts on both indoor air quality and climate. As a result, methane losses from residential buildings have been included in the latest US national inventory, with emission factors determined from a single study of homes in California. To facilitate future additional studies investigating building methane emissions, we conducted a controlled experiment to document a methodology for such measurements and estimated associated uncertainties. We determined whole-house methane emission rates with a mass balance approach using near-simultaneous measurements of indoor and outdoor methane mole fractions at a manufactured house. We quantified the uncertainty in whole-house methane emission rates by varying the forced outdoor air ventilation rate of the manufactured house, measuring the outdoor air change rate using both sulfur hexafluoride and carbon dioxide tracers, and performing methane injections at prescribed rates. We found that the whole-house quiescent methane emission rate (i.e., emission rate when all gas appliances were off) in the manufactured house averaged 0.33 g d−1 with methodological errors in the calculated emission rates of approximately 19 % (root-mean-square deviation). We also measured the quiescent leakage from the manufactured house over 3 months to find 26 % (1σ) variability in emissions over two seasons. Our findings can be used to inform plans for future studies quantifying indoor methane losses downstream of residential meters using similar methods. Such quantification studies are sorely needed to better understand building methane emissions and their drivers to inform inventories and plan mitigation strategies.
- 18 December 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (24) , 7065-7075
Open AccessMethodology and uncertainty estimation for measurements of methane leakage in a manufactured house
Methane emissions from natural gas appliances and infrastructure within buildings have historically not been captured in greenhouse gas inventories, leading to under-estimates, especially in urban areas. Recent measurements of these post-meter emissions have indicated non-negligible emissions within residences, with impacts on both indoor air quality and climate. As a result, methane losses from residential buildings have been included in the latest US national inventory, with emission factors determined from a single study of homes in California. To facilitate future additional studies investigating building methane emissions, we conducted a controlled experiment to document a methodology for such measurements and estimated associated uncertainties. We determined whole-house methane emission rates with a mass balance approach using near-simultaneous measurements of indoor and outdoor methane mole fractions at a manufactured house. We quantified the uncertainty in whole-house methane emission rates by varying the forced outdoor air ventilation rate of the manufactured house, measuring the outdoor air change rate using both sulfur hexafluoride and carbon dioxide tracers, and performing methane injections at prescribed rates. We found that the whole-house quiescent methane emission rate (i.e., emission rate when all gas appliances were off) in the manufactured house averaged 0.33 g d−1 with methodological errors in the calculated emission rates of approximately 19 % (root-mean-square deviation). We also measured the quiescent leakage from the manufactured house over 3 months to find 26 % (1σ) variability in emissions over two seasons. Our findings can be used to inform plans for future studies quantifying indoor methane losses downstream of residential meters using similar methods. Such quantification studies are sorely needed to better understand building methane emissions and their drivers to inform inventories and plan mitigation strategies.
- Open Access
- 18 October 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-17
Reply on RC2
Methane emissions from natural gas appliances and infrastructure within buildings have historically not been captured in greenhouse gas inventories, leading to under-estimates, especially in urban areas. Recent measurements of these post-meter emissions have indicated non-negligible emissions within residences, with impacts on both indoor air quality and climate. As a result, methane losses from residential buildings have recently been included in the latest U.S. national inventory, with emission factors determined from a single study of homes in California. To facilitate future additional studies investigating building methane emissions, we conducted a controlled experiment to document a methodology for such measurements and estimated associated uncertainties. We determined whole-house methane emission rates with a mass balance approach using near-simultaneous measurements of indoor and outdoor methane mole fractions at a manufactured house. We quantified the uncertainty in whole-house methane emission rates by varying the forced outdoor air ventilation rate of the manufactured house, measuring the outdoor air change rate using both sulfur hexafluoride and carbon dioxide tracers, and performing methane injections at prescribed rates. We found that the whole-house quiescent methane emission rate in the manufactured house averaged 0.34 g d-1 with methodological errors on the calculated emission rates to be approximately 20 % (root-mean-square-deviation). We also measured the quiescent leakage from the manufactured house over three months to find 24 % (1-sigma) variability in emissions over two seasons. Our findings can be used to inform plans for future studies quantifying indoor methane losses after residential meters using similar methods. Such quantification studies are sorely needed to better understand building methane emissions and their drivers to inform inventories and plan mitigation strategies.
- 18 October 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-17
Open AccessReply on RC2
Methane emissions from natural gas appliances and infrastructure within buildings have historically not been captured in greenhouse gas inventories, leading to under-estimates, especially in urban areas. Recent measurements of these post-meter emissions have indicated non-negligible emissions within residences, with impacts on both indoor air quality and climate. As a result, methane losses from residential buildings have recently been included in the latest U.S. national inventory, with emission factors determined from a single study of homes in California. To facilitate future additional studies investigating building methane emissions, we conducted a controlled experiment to document a methodology for such measurements and estimated associated uncertainties. We determined whole-house methane emission rates with a mass balance approach using near-simultaneous measurements of indoor and outdoor methane mole fractions at a manufactured house. We quantified the uncertainty in whole-house methane emission rates by varying the forced outdoor air ventilation rate of the manufactured house, measuring the outdoor air change rate using both sulfur hexafluoride and carbon dioxide tracers, and performing methane injections at prescribed rates. We found that the whole-house quiescent methane emission rate in the manufactured house averaged 0.34 g d-1 with methodological errors on the calculated emission rates to be approximately 20 % (root-mean-square-deviation). We also measured the quiescent leakage from the manufactured house over three months to find 24 % (1-sigma) variability in emissions over two seasons. Our findings can be used to inform plans for future studies quantifying indoor methane losses after residential meters using similar methods. Such quantification studies are sorely needed to better understand building methane emissions and their drivers to inform inventories and plan mitigation strategies.
- Open Access
- 18 October 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-17
Reply on RC1
Methane emissions from natural gas appliances and infrastructure within buildings have historically not been captured in greenhouse gas inventories, leading to under-estimates, especially in urban areas. Recent measurements of these post-meter emissions have indicated non-negligible emissions within residences, with impacts on both indoor air quality and climate. As a result, methane losses from residential buildings have recently been included in the latest U.S. national inventory, with emission factors determined from a single study of homes in California. To facilitate future additional studies investigating building methane emissions, we conducted a controlled experiment to document a methodology for such measurements and estimated associated uncertainties. We determined whole-house methane emission rates with a mass balance approach using near-simultaneous measurements of indoor and outdoor methane mole fractions at a manufactured house. We quantified the uncertainty in whole-house methane emission rates by varying the forced outdoor air ventilation rate of the manufactured house, measuring the outdoor air change rate using both sulfur hexafluoride and carbon dioxide tracers, and performing methane injections at prescribed rates. We found that the whole-house quiescent methane emission rate in the manufactured house averaged 0.34 g d-1 with methodological errors on the calculated emission rates to be approximately 20 % (root-mean-square-deviation). We also measured the quiescent leakage from the manufactured house over three months to find 24 % (1-sigma) variability in emissions over two seasons. Our findings can be used to inform plans for future studies quantifying indoor methane losses after residential meters using similar methods. Such quantification studies are sorely needed to better understand building methane emissions and their drivers to inform inventories and plan mitigation strategies.
- 18 October 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-17
Open AccessReply on RC1
Methane emissions from natural gas appliances and infrastructure within buildings have historically not been captured in greenhouse gas inventories, leading to under-estimates, especially in urban areas. Recent measurements of these post-meter emissions have indicated non-negligible emissions within residences, with impacts on both indoor air quality and climate. As a result, methane losses from residential buildings have recently been included in the latest U.S. national inventory, with emission factors determined from a single study of homes in California. To facilitate future additional studies investigating building methane emissions, we conducted a controlled experiment to document a methodology for such measurements and estimated associated uncertainties. We determined whole-house methane emission rates with a mass balance approach using near-simultaneous measurements of indoor and outdoor methane mole fractions at a manufactured house. We quantified the uncertainty in whole-house methane emission rates by varying the forced outdoor air ventilation rate of the manufactured house, measuring the outdoor air change rate using both sulfur hexafluoride and carbon dioxide tracers, and performing methane injections at prescribed rates. We found that the whole-house quiescent methane emission rate in the manufactured house averaged 0.34 g d-1 with methodological errors on the calculated emission rates to be approximately 20 % (root-mean-square-deviation). We also measured the quiescent leakage from the manufactured house over three months to find 24 % (1-sigma) variability in emissions over two seasons. Our findings can be used to inform plans for future studies quantifying indoor methane losses after residential meters using similar methods. Such quantification studies are sorely needed to better understand building methane emissions and their drivers to inform inventories and plan mitigation strategies.
- Open Access
- 10 September 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-17
Comment on egusphere-2024-2129
Methane emissions from natural gas appliances and infrastructure within buildings have historically not been captured in greenhouse gas inventories, leading to under-estimates, especially in urban areas. Recent measurements of these post-meter emissions have indicated non-negligible emissions within residences, with impacts on both indoor air quality and climate. As a result, methane losses from residential buildings have recently been included in the latest U.S. national inventory, with emission factors determined from a single study of homes in California. To facilitate future additional studies investigating building methane emissions, we conducted a controlled experiment to document a methodology for such measurements and estimated associated uncertainties. We determined whole-house methane emission rates with a mass balance approach using near-simultaneous measurements of indoor and outdoor methane mole fractions at a manufactured house. We quantified the uncertainty in whole-house methane emission rates by varying the forced outdoor air ventilation rate of the manufactured house, measuring the outdoor air change rate using both sulfur hexafluoride and carbon dioxide tracers, and performing methane injections at prescribed rates. We found that the whole-house quiescent methane emission rate in the manufactured house averaged 0.34 g d-1 with methodological errors on the calculated emission rates to be approximately 20 % (root-mean-square-deviation). We also measured the quiescent leakage from the manufactured house over three months to find 24 % (1-sigma) variability in emissions over two seasons. Our findings can be used to inform plans for future studies quantifying indoor methane losses after residential meters using similar methods. Such quantification studies are sorely needed to better understand building methane emissions and their drivers to inform inventories and plan mitigation strategies.
- 10 September 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-17
Open AccessComment on egusphere-2024-2129
Methane emissions from natural gas appliances and infrastructure within buildings have historically not been captured in greenhouse gas inventories, leading to under-estimates, especially in urban areas. Recent measurements of these post-meter emissions have indicated non-negligible emissions within residences, with impacts on both indoor air quality and climate. As a result, methane losses from residential buildings have recently been included in the latest U.S. national inventory, with emission factors determined from a single study of homes in California. To facilitate future additional studies investigating building methane emissions, we conducted a controlled experiment to document a methodology for such measurements and estimated associated uncertainties. We determined whole-house methane emission rates with a mass balance approach using near-simultaneous measurements of indoor and outdoor methane mole fractions at a manufactured house. We quantified the uncertainty in whole-house methane emission rates by varying the forced outdoor air ventilation rate of the manufactured house, measuring the outdoor air change rate using both sulfur hexafluoride and carbon dioxide tracers, and performing methane injections at prescribed rates. We found that the whole-house quiescent methane emission rate in the manufactured house averaged 0.34 g d-1 with methodological errors on the calculated emission rates to be approximately 20 % (root-mean-square-deviation). We also measured the quiescent leakage from the manufactured house over three months to find 24 % (1-sigma) variability in emissions over two seasons. Our findings can be used to inform plans for future studies quantifying indoor methane losses after residential meters using similar methods. Such quantification studies are sorely needed to better understand building methane emissions and their drivers to inform inventories and plan mitigation strategies.