Mohammad Khorsand-Ghayeni
Research Subjects
Mohammad Khorsand-Ghayeni has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Amir Mahdi Molavi
Department of Materials Research, Iranian Academic Center for Education, Culture and Research (ACECR), Mashhad, Iran
6 shared publications Samira Nokhasteh
Mashhad Branch, department of Materials Research, ACECR, Mashhad, khorasan razavi
4 shared publicationsAlireza Sadeghi-Avalshahr
Department of Materials Research, Iranian Academic Center for Education, Culture and Research (ACECR), Mashhad, Iran
3 shared publications- Alireza Sadeghi-Avalshahr
Academic Center for Education, Culture and Research (ACECR)
3 shared publications - Hojjat Naderi-Meshkin
Stem Cell and Regenerative Medicine Research Group, Academic Center for Education, Culture Research (ACECR), Khorasan Razavi Branch, Mashhad, Iran
3 shared publications A. Mahdizadeh
Nanotechnology Institute, University of Sistan and Baluchestan, Zahedan, Iran
2 shared publications
Latest Publications
- Open Access
- 9 December 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 7 (1) , 015401
Preparation of PVA/Chitosan samples by electrospinning and film casting methods and evaluating the effect of surface morphology on their antibacterial behavior
Chitosan due to outstanding properties including biocompatibility, biodegradability, nontoxicity and antibacterial activity has received considerable attention in different fields of biomedical engineering. To study the effect of morphology and topology on antibacterial activity of chitosan, two samples of PVA/Chitosan blend with the same concentration and volume ratio were prepared using electrospinning and film casting methods. To improve the electrospinability of chitosan, it was hydrolyzed by 50% V NaOH solution (95 °C for 48 h.) and PVA was used as an auxiliary polymer for electrospinning. The best electrospinning parameters for producing beadless structure were determined at a voltage of 21 kV and distance of 15 cm. Different physical and chemical characterizations of produced samples were performed using scanning electron microscopy (SEM), Fourier Transform Infrared Spectroscopy (FTIR), viscosimetry, Atomic Force Microscopy (AFM) and antibacterial assay by two different bacterium strains including Escherichia coli (E.coli) as the gram-negative and Staphylococcus aureus (S.aureus) as the gram-positive bacteria. Antibacterial assays revealed higher sensitivity of E.coli in comparison with S.aureus in the two samples. Also, it revealed that nanotopography of surface wielded influence on the antibacterial activity of samples.
- 9 December 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 7 (1) , 015401
Open AccessPreparation of PVA/Chitosan samples by electrospinning and film casting methods and evaluating the effect of surface morphology on their antibacterial behavior
Chitosan due to outstanding properties including biocompatibility, biodegradability, nontoxicity and antibacterial activity has received considerable attention in different fields of biomedical engineering. To study the effect of morphology and topology on antibacterial activity of chitosan, two samples of PVA/Chitosan blend with the same concentration and volume ratio were prepared using electrospinning and film casting methods. To improve the electrospinability of chitosan, it was hydrolyzed by 50% V NaOH solution (95 °C for 48 h.) and PVA was used as an auxiliary polymer for electrospinning. The best electrospinning parameters for producing beadless structure were determined at a voltage of 21 kV and distance of 15 cm. Different physical and chemical characterizations of produced samples were performed using scanning electron microscopy (SEM), Fourier Transform Infrared Spectroscopy (FTIR), viscosimetry, Atomic Force Microscopy (AFM) and antibacterial assay by two different bacterium strains including Escherichia coli (E.coli) as the gram-negative and Staphylococcus aureus (S.aureus) as the gram-positive bacteria. Antibacterial assays revealed higher sensitivity of E.coli in comparison with S.aureus in the two samples. Also, it revealed that nanotopography of surface wielded influence on the antibacterial activity of samples.
- Open Access
- 11 May 2018
- Published by Springer Nature in Progress in Biomaterials
- Vol. 7 (2) , 111-119
Effect of bioactive glass nanoparticles on biological properties of PLGA/collagen scaffold
Bioactive glasses have shown some interesting biological properties such as biocompatibility, biodegradation, and angiogenesis in skin tissue engineering. In the current research, the effects of MgO- or CoO-doped 64S bioactive glass with a composition of 64 SiO2-26 CaO-5 P2O5-5 MgO or CoO (mol%) were studied in relation with biological properties of electrospun [poly(lactic-co-glycolic acid) (PLGA)/collagen]. PLGA/collagen samples were rinsed in suspension of bioactive glass nanoparticles in distilled water with a concentration of 0.1 w/v and then freeze dried. Cell adhesion, viability, angiogenesis, and ionic release were performed and tested in culture medium containing fibroblast cells. Attachment and viability of fibroblast cells were increased significantly in bioglass-coated samples, while shrinkage in PLGA/collagen scaffold was reduced by the addition of bioactive glass. Vascular endothelial growth factor secretion in coated scaffold was dropped compared to the uncoated samples. This could be attributed to the fast degradation of glass nanoparticles, according to the inductively coupled plasma-atomic emission spectroscopy results.
- 11 May 2018
- Published by Springer Nature in Progress in Biomaterials
- Vol. 7 (2) , 111-119
Open AccessEffect of bioactive glass nanoparticles on biological properties of PLGA/collagen scaffold
Bioactive glasses have shown some interesting biological properties such as biocompatibility, biodegradation, and angiogenesis in skin tissue engineering. In the current research, the effects of MgO- or CoO-doped 64S bioactive glass with a composition of 64 SiO2-26 CaO-5 P2O5-5 MgO or CoO (mol%) were studied in relation with biological properties of electrospun [poly(lactic-co-glycolic acid) (PLGA)/collagen]. PLGA/collagen samples were rinsed in suspension of bioactive glass nanoparticles in distilled water with a concentration of 0.1 w/v and then freeze dried. Cell adhesion, viability, angiogenesis, and ionic release were performed and tested in culture medium containing fibroblast cells. Attachment and viability of fibroblast cells were increased significantly in bioglass-coated samples, while shrinkage in PLGA/collagen scaffold was reduced by the addition of bioactive glass. Vascular endothelial growth factor secretion in coated scaffold was dropped compared to the uncoated samples. This could be attributed to the fast degradation of glass nanoparticles, according to the inductively coupled plasma-atomic emission spectroscopy results.
- Open Access
- 25 September 2017
- Published by Oxford University Press (OUP) in Regenerative Biomaterials
- Vol. 4 (5) , 309-314
Synthesis and characterization of collagen/PLGA biodegradable skin scaffold fibers
The aim of this study is to investigate the applicability of poly(lactic-co-glycolic acid) (PLGA)/collagen composite scaffold for skin tissue engineering. PLGA and collagen were dissolved in HFIP as a common solvent and fibrous scaffolds were prepared by electrospinning method. The scaffolds were characterized by scanning electron microscopy (SEM), FTIR spectroscopy, mercury porosimetry, tensile strength, biocompatibility assays and Biodegradation. Cytotoxicity and cell adhesion were tested for two cell line groups, human dermal fibroblast (HDF) and human keratinocyte (HaCat). SEM images showed appropriate cell adhesion to the scaffold for both cell lines. MTT assays indicated that the cell viability of HDF cells increased with time, but the number of HaCat cells decreased after 14 days. The ultimate tensile strength was suitable for skin substitute application, but its elongation at break was rather low. For successful clinical application of the PLGA/collagen scaffold, some properties especially mechanical strain needs to be improved.
- 25 September 2017
- Published by Oxford University Press (OUP) in Regenerative Biomaterials
- Vol. 4 (5) , 309-314
Open AccessSynthesis and characterization of collagen/PLGA biodegradable skin scaffold fibers
The aim of this study is to investigate the applicability of poly(lactic-co-glycolic acid) (PLGA)/collagen composite scaffold for skin tissue engineering. PLGA and collagen were dissolved in HFIP as a common solvent and fibrous scaffolds were prepared by electrospinning method. The scaffolds were characterized by scanning electron microscopy (SEM), FTIR spectroscopy, mercury porosimetry, tensile strength, biocompatibility assays and Biodegradation. Cytotoxicity and cell adhesion were tested for two cell line groups, human dermal fibroblast (HDF) and human keratinocyte (HaCat). SEM images showed appropriate cell adhesion to the scaffold for both cell lines. MTT assays indicated that the cell viability of HDF cells increased with time, but the number of HaCat cells decreased after 14 days. The ultimate tensile strength was suitable for skin substitute application, but its elongation at break was rather low. For successful clinical application of the PLGA/collagen scaffold, some properties especially mechanical strain needs to be improved.
- 30 August 2017
- Published by Springer Nature in Polymer Bulletin
- Vol. 75 (6) , 2559-2574
Effects of hydroxyapatite (HA) particles on the PLLA polymeric matrix for fabrication of absorbable interference screws
- 30 August 2017
- Published by Springer Nature in Polymer Bulletin
- Vol. 75 (6) , 2559-2574
Effects of hydroxyapatite (HA) particles on the PLLA polymeric matrix for fabrication of absorbable interference screws
- 19 December 2016
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 28 (1) , 1-10
Synthesis and characterization of PLGA/collagen composite scaffolds as skin substitute produced by electrospinning through two different approaches
Skin damage can occur for many reasons, including burns and injuries, which in extreme cases can even lead to death. Different methods such as electrospinning are used to produce scaffolds used in skin tissue engineering. Natural and synthetic polymers were used in this method. It was observed that the use of both natural and synthetic polymers gives better results for cell culturing rather than using of each material solely. In this study, scaffolds of poly(lactic-co-glycolic acid) and collagen were prepared using coating and common solvent methods. The characteristics of samples were evaluated through scanning electron microscopy, porosimetry, mechanical testing, degradation behavior, and in vitro assays. The mechanical and biocompatibility test results of the scaffold prepared by coating method were better than the other one. However, the degradation rate of the common solvent was nearly five times more than coating sample that leads to cytotoxicity in contact with the skin cells.
- 19 December 2016
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 28 (1) , 1-10
Synthesis and characterization of PLGA/collagen composite scaffolds as skin substitute produced by electrospinning through two different approaches
Skin damage can occur for many reasons, including burns and injuries, which in extreme cases can even lead to death. Different methods such as electrospinning are used to produce scaffolds used in skin tissue engineering. Natural and synthetic polymers were used in this method. It was observed that the use of both natural and synthetic polymers gives better results for cell culturing rather than using of each material solely. In this study, scaffolds of poly(lactic-co-glycolic acid) and collagen were prepared using coating and common solvent methods. The characteristics of samples were evaluated through scanning electron microscopy, porosimetry, mechanical testing, degradation behavior, and in vitro assays. The mechanical and biocompatibility test results of the scaffold prepared by coating method were better than the other one. However, the degradation rate of the common solvent was nearly five times more than coating sample that leads to cytotoxicity in contact with the skin cells.
- 1 December 2016
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 93, 1317-1327
PH-sensitive bionanocomposite hydrogel beads based on carboxymethyl cellulose/ZnO nanoparticle as drug carrier
- 1 December 2016
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 93, 1317-1327
PH-sensitive bionanocomposite hydrogel beads based on carboxymethyl cellulose/ZnO nanoparticle as drug carrier
- 11 October 2016
- Published by Springer Nature in Polymer Bulletin
- Vol. 74 (6) , 2081-2097
Fabrication of asymmetric and symmetric membranes based on PES/PEG/DMAc
- 11 October 2016
- Published by Springer Nature in Polymer Bulletin
- Vol. 74 (6) , 2081-2097
Fabrication of asymmetric and symmetric membranes based on PES/PEG/DMAc
- 1 September 2016
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 66, 130-137
Surface modification of electrospun PLGA scaffold with collagen for bioengineered skin substitutes
- 1 September 2016
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 66, 130-137
Surface modification of electrospun PLGA scaffold with collagen for bioengineered skin substitutes