John Thrower
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
John Thrower has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Phil Webb
Cranfield University
2 shared publications Ashutosh Tiwari
1 shared publication- Ashutosh Tiwari
Cranfield University
1 shared publication - Boyang Song
Department of Automatic Control and Systems Engineering, The University of Sheffield, Sheffield S1 3JD, U.K
1 shared publication - Christopher Turner
Surrey Business School, University of Surrey, Guildford GU2 7XH, UK
1 shared publication - Gilbert Tang
Cranfield University
1 shared publication
Latest Publications
- Open Access
- 1 April 2019
- Published by Elsevier in Robotics and Computer-Integrated Manufacturing
- Vol. 56, 85-94
The development and evaluation of Robot Light Skin: A novel robot signalling system to improve communication in industrial human–robot collaboration
- 1 April 2019
- Published by Elsevier in Robotics and Computer-Integrated Manufacturing
- Vol. 56, 85-94
Open AccessThe development and evaluation of Robot Light Skin: A novel robot signalling system to improve communication in industrial human–robot collaboration
- Open Access
- 1 October 2016
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture
- Vol. 232 (1) , 90-98
A study to trial the use of inertial non-optical motion capture for ergonomic analysis of manufacturing work
It is going to be increasingly important for manufacturing system designers to incorporate human activity data and ergonomic analysis with other performance data in digital design modelling and system monitoring. However, traditional methods of capturing human activity data are not sufficiently accurate to meet the needs of digitised data analysis; qualitative data are subject to bias and imprecision, and optically derived data are hindered by occlusions caused by structures or other people in a working environment. Therefore, to meet contemporary needs for more accurate and objective data, inertial non-optical methods of measurement appear to offer a solution. This article describes a case study conducted within the aerospace manufacturing industry, where data on the human activities involved in aircraft wing system installations was first collected via traditional ethnographic methods and found to have limited accuracy and suitability for digital modelling, but similar human activity data subsequently collected using an automatic non-optical motion capture system in a more controlled environment showed better suitability. Results demonstrate the potential benefits of applying not only the inertial non-optical method in future digital modelling and performance monitoring but also the value of continuing to include qualitative analysis for richer interpretation of important explanatory factors.
- 1 October 2016
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture
- Vol. 232 (1) , 90-98
Open AccessA study to trial the use of inertial non-optical motion capture for ergonomic analysis of manufacturing work
It is going to be increasingly important for manufacturing system designers to incorporate human activity data and ergonomic analysis with other performance data in digital design modelling and system monitoring. However, traditional methods of capturing human activity data are not sufficiently accurate to meet the needs of digitised data analysis; qualitative data are subject to bias and imprecision, and optically derived data are hindered by occlusions caused by structures or other people in a working environment. Therefore, to meet contemporary needs for more accurate and objective data, inertial non-optical methods of measurement appear to offer a solution. This article describes a case study conducted within the aerospace manufacturing industry, where data on the human activities involved in aircraft wing system installations was first collected via traditional ethnographic methods and found to have limited accuracy and suitability for digital modelling, but similar human activity data subsequently collected using an automatic non-optical motion capture system in a more controlled environment showed better suitability. Results demonstrate the potential benefits of applying not only the inertial non-optical method in future digital modelling and performance monitoring but also the value of continuing to include qualitative analysis for richer interpretation of important explanatory factors.
- Open Access
- 9 October 2015
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 85 (1-4) , 163-184
Digitisation of a moving assembly operation using multiple depth imaging sensors
- 9 October 2015
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 85 (1-4) , 163-184
Open AccessDigitisation of a moving assembly operation using multiple depth imaging sensors
- Open Access
- 1 January 2014
- Published by Elsevier in Procedia CIRP
- Vol. 25, 161-168
Dynamic Alignment Control Using Depth Imagery for Automated Wheel Assembly
- 1 January 2014
- Published by Elsevier in Procedia CIRP
- Vol. 25, 161-168
Open AccessDynamic Alignment Control Using Depth Imagery for Automated Wheel Assembly