Muhammad Umer Qureshi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muhammad Umer Qureshi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Santiago Grijalva
Georgia Institute of Technology, Atlanta, GA, USA
3 shared publicationsJeremiah Deboever
Electric Power Research Institute, Palo Alto, CA
2 shared publications- Santiago Grijalva
Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
2 shared publications - Anand Kumar
Department of Electrical and Electronics Engineering, Sarala Birla University, Ranchi 835103, India
1 shared publication - Jouni Peppanen
EPRI
1 shared publication - Magnus Egerstedt
Department of Electrical Engineering and Computer Science, University of California, Irvine, CA, USA
1 shared publication
Latest Publications
- 11 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fast Hosting Capacity Analysis for Thermal Loading Constraint Using Sensitivity-based Decomposition Method
High solar photovoltaic (PV) penetration can cause reverse power flows that exceed the thermal loading limits of distribution transformers, lines, and other equipment. PV hosting capacity refers to the amount of solar PV that a feeder location can accommodate without adverse power quality, reliability, or safety impacts. Previous work has established that the nodal voltage magnitude has a quasi-linear relationship with the feeder load and PV power injections. However, the analysis of circuit thermal limits in hosting capacity is more difficult due to the nonlinear nature of the line current magnitude. This paper uses a decomposition method that combines real and reactive power flow manifolds to accurately estimate the branch current magnitude and consequently, the thermal hosting capacity. The method requires solving only a small number of nonlinear AC power flows and has the potential to significantly speed up PV hosting capacity analysis. The accuracy of the proposed method is evaluated on the IEEE 123 bus test circuit.
- 11 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fast Hosting Capacity Analysis for Thermal Loading Constraint Using Sensitivity-based Decomposition Method
High solar photovoltaic (PV) penetration can cause reverse power flows that exceed the thermal loading limits of distribution transformers, lines, and other equipment. PV hosting capacity refers to the amount of solar PV that a feeder location can accommodate without adverse power quality, reliability, or safety impacts. Previous work has established that the nodal voltage magnitude has a quasi-linear relationship with the feeder load and PV power injections. However, the analysis of circuit thermal limits in hosting capacity is more difficult due to the nonlinear nature of the line current magnitude. This paper uses a decomposition method that combines real and reactive power flow manifolds to accurately estimate the branch current magnitude and consequently, the thermal hosting capacity. The method requires solving only a small number of nonlinear AC power flows and has the potential to significantly speed up PV hosting capacity analysis. The accuracy of the proposed method is evaluated on the IEEE 123 bus test circuit.
- 7 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 10 (1) , 301-310
A Fast Scalable Quasi-Static Time Series Analysis Method for PV Impact Studies Using Linear Sensitivity Model
Understanding the impact of distributed photovoltaic (PV) resources on various elements of the distribution feeder is imperative for their cost effective integration. A year-long quasi-static time series (QSTS) simulation at 1-second granularity is often necessary to fully study these impacts. However, the significant computational burden associated with running QSTS simulations is a major challenge to their adoption. In this paper, we propose a fast scalable QSTS simulation algorithm that is based on a linear sensitivity model for estimating voltage-related PV impact metrics of a three-phase unbalanced, nonradial distribution system with various discrete step control elements including tap changing transformers and capacitor banks. The algorithm relies on computing voltage sensitivities while taking into account all the effects of discrete controllable elements in the circuit. Consequently, the proposed sensitivity model can accurately estimate the state of controllers at each time step and the number of control actions throughout the year. For the test case of a real distribution feeder with 2969 buses (5469 nodes), 6 load/PV time series power profiles, and 9 voltage regulating elements including controller delays, the proposed algorithm demonstrates a dramatic time reduction, more than 180 times faster than traditional QSTS techniques.
- 7 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 10 (1) , 301-310
A Fast Scalable Quasi-Static Time Series Analysis Method for PV Impact Studies Using Linear Sensitivity Model
Understanding the impact of distributed photovoltaic (PV) resources on various elements of the distribution feeder is imperative for their cost effective integration. A year-long quasi-static time series (QSTS) simulation at 1-second granularity is often necessary to fully study these impacts. However, the significant computational burden associated with running QSTS simulations is a major challenge to their adoption. In this paper, we propose a fast scalable QSTS simulation algorithm that is based on a linear sensitivity model for estimating voltage-related PV impact metrics of a three-phase unbalanced, nonradial distribution system with various discrete step control elements including tap changing transformers and capacitor banks. The algorithm relies on computing voltage sensitivities while taking into account all the effects of discrete controllable elements in the circuit. Consequently, the proposed sensitivity model can accurately estimate the state of controllers at each time step and the number of control actions throughout the year. For the test case of a real distribution feeder with 2969 buses (5469 nodes), 6 load/PV time series power profiles, and 9 voltage regulating elements including controller delays, the proposed algorithm demonstrates a dramatic time reduction, more than 180 times faster than traditional QSTS techniques.
- 2 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (2) , 1746-1755
Enhanced Frequency Response Based on Multiagent Distributed Power Agreement
In this paper, we propose a multi-agent based distributed algorithm for enhanced frequency response in large scale multi-area power systems. Control nodes associated with these areas preemptively agree on their relative contributions in supporting the frequency response, in a completely distributed manner. Consequently, in case of system contingencies, each area knows the total change in generation required to facilitate faster frequency restoration during primary frequency control. Within an area, local controllers associated with generators execute a distributed power agreement via sparse information exchange to achieve this required change in generation. As a result of these coordinated control actions, frequency deviation from the nominal remains minimal thereby reducing the dependency on secondary frequency control. Inspired from graph theoretic techniques in networked controls, the proposed architecture requires nodes with minimalistic computation and communication capabilities thereby increasing its applicability. Simulations performed on a large test case demonstrate the efficacy of the proposed algorithm in improving the transient performance of the frequency response.
- 2 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (2) , 1746-1755
Enhanced Frequency Response Based on Multiagent Distributed Power Agreement
In this paper, we propose a multi-agent based distributed algorithm for enhanced frequency response in large scale multi-area power systems. Control nodes associated with these areas preemptively agree on their relative contributions in supporting the frequency response, in a completely distributed manner. Consequently, in case of system contingencies, each area knows the total change in generation required to facilitate faster frequency restoration during primary frequency control. Within an area, local controllers associated with generators execute a distributed power agreement via sparse information exchange to achieve this required change in generation. As a result of these coordinated control actions, frequency deviation from the nominal remains minimal thereby reducing the dependency on secondary frequency control. Inspired from graph theoretic techniques in networked controls, the proposed architecture requires nodes with minimalistic computation and communication capabilities thereby increasing its applicability. Simulations performed on a large test case demonstrate the efficacy of the proposed algorithm in improving the transient performance of the frequency response.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Multi-agent based distributed power agreement for enhanced frequency response of transmission systems
In this paper, we propose a distributed open loop control algorithm for large-scale transmission systems having multiple control areas exchanging power through tie-lines. Inspired from graph theoretic methods in multi-agent systems, it ensures a high degree of coordination among control areas to improve the frequency response with minimal inter-area oscillations in case of sudden loss of generation. Local nodes associated with generation units coordinate with regional nodes monitoring tie-line flows to ensure load-generation balance is maintained at all times with sparse information exchange. We develop a Cyber-Physical abstraction which allows for a scalable architecture that is independent of the internal dynamics of the control areas. Consequently, these areas can quantitatively predefine their contribution in frequency restoration during primary control. We perform simulations on a test system resulting in improved frequency response and reduced deviation from the nominal frequency, demonstrating the efficacy of our proposed protocol.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Multi-agent based distributed power agreement for enhanced frequency response of transmission systems
In this paper, we propose a distributed open loop control algorithm for large-scale transmission systems having multiple control areas exchanging power through tie-lines. Inspired from graph theoretic methods in multi-agent systems, it ensures a high degree of coordination among control areas to improve the frequency response with minimal inter-area oscillations in case of sudden loss of generation. Local nodes associated with generation units coordinate with regional nodes monitoring tie-line flows to ensure load-generation balance is maintained at all times with sparse information exchange. We develop a Cyber-Physical abstraction which allows for a scalable architecture that is independent of the internal dynamics of the control areas. Consequently, these areas can quantitatively predefine their contribution in frequency restoration during primary control. We perform simulations on a test system resulting in improved frequency response and reduced deviation from the nominal frequency, demonstrating the efficacy of our proposed protocol.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 381-387
Decentralized Power Agreement for Improved Frequency Response in Interconnected Power Systems
Maintaining grid frequency close to the nominal value is one of the fundamental objectives of electric power operations. In this paper, we develop a decentralized control algorithm to improve the frequency response in case of sudden loss of generation in an interconnected grid. We propose a Cyber-Physical Architecture that requires minimal information exchange between control areas to reduce the frequency deviation from the nominal, in a distributed manner and also act on a much faster time scale as compared to traditional frequency regulation schemes. To achieve this, a decentralized Power Agreement protocol is proposed and analyzed. Finally simulations are performed to demonstrate the effectiveness of proposed protocol in improving both transient and steady state performance of the system.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 381-387
Decentralized Power Agreement for Improved Frequency Response in Interconnected Power Systems
Maintaining grid frequency close to the nominal value is one of the fundamental objectives of electric power operations. In this paper, we develop a decentralized control algorithm to improve the frequency response in case of sudden loss of generation in an interconnected grid. We propose a Cyber-Physical Architecture that requires minimal information exchange between control areas to reduce the frequency deviation from the nominal, in a distributed manner and also act on a much faster time scale as compared to traditional frequency regulation schemes. To achieve this, a decentralized Power Agreement protocol is proposed and analyzed. Finally simulations are performed to demonstrate the effectiveness of proposed protocol in improving both transient and steady state performance of the system.
- Open Access
Hamiltonian-based Algorithm for Relaxed Optimal Control
This paper concerns a first-order algorithmic technique for a class of optimal control problems defined on switched-mode hybrid systems. The salient feature of the algorithm is that it avoids the computation of Fr\'echet or G\^ateaux derivatives of the cost functional, which can be time consuming, but rather moves in a projected-gradient direction that is easily computable (for a class of problems) and does not require any explicit derivatives. The algorithm is applicable to a class of problems where a pointwise minimizer of the Hamiltonian is computable by a simple formula, and this includes many problems that arise in theory and applications. The natural setting for the algorithm is the space of continuous-time relaxed controls, whose special structure renders the analysis simpler than the setting of ordinary controls. While the space of relaxed controls has theoretical advantages, its elements are abstract entities that may not be amenable to computation. Therefore, a key feature of the algorithm is that it computes adequate approximations to relaxed controls without loosing its theoretical convergence properties. Simulation results, including cpu times, support the theoretical developments.
Open AccessHamiltonian-based Algorithm for Relaxed Optimal Control
This paper concerns a first-order algorithmic technique for a class of optimal control problems defined on switched-mode hybrid systems. The salient feature of the algorithm is that it avoids the computation of Fr\'echet or G\^ateaux derivatives of the cost functional, which can be time consuming, but rather moves in a projected-gradient direction that is easily computable (for a class of problems) and does not require any explicit derivatives. The algorithm is applicable to a class of problems where a pointwise minimizer of the Hamiltonian is computable by a simple formula, and this includes many problems that arise in theory and applications. The natural setting for the algorithm is the space of continuous-time relaxed controls, whose special structure renders the analysis simpler than the setting of ordinary controls. While the space of relaxed controls has theoretical advantages, its elements are abstract entities that may not be amenable to computation. Therefore, a key feature of the algorithm is that it computes adequate approximations to relaxed controls without loosing its theoretical convergence properties. Simulation results, including cpu times, support the theoretical developments.