DGDavid Guiraud

David Guiraud

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Guiraud has a total of 222 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Author Correction: Bringing sensation to prosthetic hands—chronic assessment of implanted thin-film electrodes in humans

    by Paul Čvančara, Giacomo Valle, Matthias Müller, Inga Bartels, Thomas Guiho, Arthur Hiairrassary, Francesco Petrini, Stanisa Raspopovic, Ivo Strauss, Giuseppe Granata, et al.


  • Open Access

    Bringing sensation to prosthetic hands—chronic assessment of implanted thin-film electrodes in humans

    by Paul Čvančara, Giacomo Valle, Matthias Müller, Inga Bartels, Thomas Guiho, Arthur Hiairrassary, Francesco Petrini, Stanisa Raspopovic, Ivo Strauss, Giuseppe Granata, et al.

    Direct stimulation of peripheral nerves with implantable electrodes successfully provided sensory feedback to amputees while using hand prostheses. Longevity of the electrodes is key to success, which we have improved for the polyimide-based transverse intrafascicular multichannel electrode (TIME). The TIMEs were implanted in the median and ulnar nerves of three trans-radial amputees for up to six months. We present a comprehensive assessment of the electrical properties of the thin-film metallization as well as material status post explantationem. The TIMEs stayed within the electrochemical safe limits while enabling consistent and precise amplitude modulation. This lead to a reliable performance in terms of eliciting sensation. No signs of corrosion or morphological change to the thin-film metallization of the probes was observed by means of electrochemical and optical analysis. The presented longevity demonstrates that thin-film electrodes are applicable in permanent implant systems.


  • Open Access

    Activating effective functional hand movements in individuals with complete tetraplegia through neural stimulation

    by Christine Azevedo Coste, Lucie William, Lucas Fonseca, Arthur Hiairrassary, David Andreu, Antoine Geffrier, Jacques Teissier, Charles Fattal, David Guiraud

    Individuals with complete cervical spinal cord injury suffer from a permanent paralysis of upper limbs which prevents them from achieving most of the activities of daily living. We developed a neuroprosthetic solution to restore hand motor function. Electrical stimulation of the radial and median nerves by means of two epineural electrodes enabled functional movements of paralyzed hands. We demonstrated in two participants with complete tetraplegia that selective stimulation of nerve fascicles by means of optimized spreading of the current over the active contacts of the multicontact epineural electrodes induced functional and powerful grasping movements which remained stable over the 28 days of implantation. We also showed that participants were able to trigger the activation of movements of their paralyzed limb using an intuitive interface controlled by voluntary actions and that they were able to perform useful functional movements such as holding a can and drinking through a straw.


  • Open Access

    Synchronous Multichannel Stimulator with Embedded Safety Procedure to Perform 12-Poles TIME-3H 3D Stimulation

    by David Andreu, Pawel Maciejasz, Robin Passama, Guy Cathebras, Guillaume Souquet, Loic Wauters, Jean-Louis Divoux, David Guiraud

    The human functions are controlled through different ways among which both central and peripheral nervous systems (CNS, PNS) play a major part. Within this complex network, the information code is based on action potential (AP) generation. Then, when a sensory function is deficient, inducing APs provides for a partial restoration of the lost function.

  • Open Access

    A Residual Movement Classification Based User Interface for Control of Assistive Devices by Persons With Complete Tetraplegia

    by Lucas Fonseca, David Guiraud, Arthur Hiairrassary, Charles Fattal, Christine Azevedo-Coste

    Objective: Complete tetraplegia can deprive a person of hand function. Assistive technologies may improve autonomy but needs for ergonomic interfaces for the user to pilot these devices still persist. Despite the paralysis of their arms, people with tetraplegia may retain residual shoulder movements. In this work we explored these movements as a mean to control assistive devices. Methods: We captured shoulder movement with a single inertial sensor and, by training a support vector machine based classifier, we decode such information into user intent. Results: The setup and training process take only a few minutes and so the classifiers can be user specific. We tested the algorithm with 10 able body and 2 spinal cord injury participants. The average classification accuracy was 80% and 84%, respectively. Conclusion: The proposed algorithm is easy to set up, its operation is fully automated, and achieved results are on par with state-of-the-art systems. Significance: Assistive devices for persons without hand function present limitations in their user interfaces. Our work presents a novel method to overcome some of these limitations by classifying user movement and decoding it into user intent, all with simple setup and training and no need for manual tuning. We demonstrate its feasibility with experiments with end users, including persons with complete tetraplegia without hand function.


  • Open Access

    Frequency-Domain sEMG Classification Using a Single Sensor

    by Thekla Stefanou, David Guiraud, Charles Fattal, Christine Azevedo-Coste, Lucas Fonseca

    Working towards the development of robust motion recognition systems for assistive technology control, the widespread approach has been to use a plethora of, often times, multi-modal sensors. In this paper, we develop single-sensor motion recognition systems. Utilising the peripheral nature of surface electromyography (sEMG) data acquisition, we optimise the information extracted from sEMG sensors. This allows the reduction in sEMG sensors or provision of contingencies in a system with redundancies. In particular, we process the sEMG readings captured at the trapezius descendens and platysma muscles. We demonstrate that sEMG readings captured at one muscle contain distinct information on movements or contractions of other agonists. We used the trapezius and platysma muscle sEMG data captured in able-bodied participants and participants with tetraplegia to classify shoulder movements and platysma contractions using white-box supervised learning algorithms. Using the trapezius sensor, shoulder raise is classified with an accuracy of 99%. Implementing subject-specific multi-class classification, shoulder raise, shoulder forward and shoulder backward are classified with a 94% accuracy amongst object raise and shoulder raise-and-hold data in able bodied adults. A three-way classification of the platysma sensor data captured with participants with tetraplegia achieves a 95% accuracy on platysma contraction and shoulder raise detection.


  • Open Access

    New Stimulation Device to Drive Multiple Transverse Intrafascicular Electrodes and Achieve Highly Selective and Rich Neural Responses

    by Thomas Guiho, Victor Manuel López-Álvarez, Paul Čvančara, Arthur Hiairrassary, David Andreu, Thomas Stieglitz, Xavier Navarro, David Guiraud

    Peripheral Nerve Stimulation (PNS) is a promising approach in functional restoration following neural impairments. Although it proves to be advantageous in the number of implantation sites provided compared with intramuscular or epimysial stimulation and the fact that it does not require daily placement, as is the case with surface electrodes, the further advancement of PNS paradigms is hampered by the limitation of spatial selectivity due to the current spread and variations of nerve physiology. New electrode designs such as the Transverse Intrafascicular Multichannel Electrode (TIME) were proposed to resolve this issue, but their use was limited by a lack of innovative multichannel stimulation devices. In this study, we introduce a new portable multichannel stimulator—called STIMEP—and implement different stimulation protocols in rats to test its versatility and unveil the potential of its combined use with TIME electrodes in rehabilitation protocols. We developed and tested various stimulation paradigms in a single fascicle and thereafter implanted two TIMEs. We also tested its stimulation using two different waveforms. The results highlighted the versatility of this new stimulation device and advocated for the parameterizing of a hyperpolarizing phase before depolarization as well as the use of small pulse widths when stimulating with multiple electrodes.


  • Open Access

    Contribution of Single-Fiber Evaluation on Monitoring Outcomes Following Injection of Botulinum Toxin-A: A Narrative Review of the Literature

    by Hélène Moron, Corine Gagnard-Landra, David Guiraud, Arnaud Dupeyron

    Botulinum toxin-A (BoNT-A) blocks acetylcholine release at the neuromuscular junction (NMJ) and is widely used for neuromuscular disorders (involuntary spasms, dystonic disorders and spasticity). However, its therapeutic effects are usually measured by clinical scales of questionable validity. Single-fiber electromyography (SFEMG) is a sensitive, validated diagnostic technique for NMJ impairment such as myasthenia. The jitter parameter (µs) represents the variability of interpotential intervals of two muscle fibers from the same motor unit. This narrative review reports SFEMG use in BoNT-A treatment. Twenty-four articles were selected from 175 eligible articles searched in Medline/Pubmed and Cochrane Library from their creation until May 2020. The results showed that jitter is sensitive to early NMJ modifications following BoNT-A injection, with an increase in the early days’ post-injection and a peak between Day 15 and 30, when symptoms diminish or disappear. The reappearance of symptoms accompanies a tendency for a decrease in jitter, but always precedes its normalization, either delayed or nonexistent. Increased jitter is observed in distant muscles from the injection site. No dose effect relationship was demonstrated. SFEMG could help physicians in their therapeutic evaluation according to the pathology considered. More data are needed to consider jitter as a predictor of BoNT-A clinical efficacy.