Hans-Ulrich Laasch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hans-Ulrich Laasch has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Derek William Edwards
Minnova Medical Foundation CIC
3 shared publications- Alexander Oh
Dept. of Emergency Medicine, Maidstone and Tunbridge Wells NHS Trust, UK
2 shared publications Daniel Pintos dos Santos
Department of Radiology, University Köln, Cologne, Germany
2 shared publicationsDerek W. Edwards
Minnova Medical Foundation CIC, Wilmslow, UK
2 shared publications- Derek William Edwards
Departent of Natural Sciences, University of Chester, Chester, United Kingdom
2 shared publications Graham D. Milward
Minnova Medical Foundation CIC, Wilmslow, UK
2 shared publications
Latest Publications
- Open Access
- 24 February 2026
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 15 (2) , 69-72
In vivo corrosion of esophageal stents: An emerging materials problem
Hans-Ulrich Laasch, Connor J Weaver, Stephen J Black, Graham C Smith, and Derek William Edwards. Int J Gastrointest Interv -0001;0:. https://doi.org/10.18528/ijgii250085
- 24 February 2026
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 15 (2) , 69-72
Open AccessIn vivo corrosion of esophageal stents: An emerging materials problem
Hans-Ulrich Laasch, Connor J Weaver, Stephen J Black, Graham C Smith, and Derek William Edwards. Int J Gastrointest Interv -0001;0:. https://doi.org/10.18528/ijgii250085
- Open Access
- 10 January 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-7
A standardised comparison of chest and percutaneous drainage catheters to evaluate the applicability of the ‘French’ sizing units
A variety of medical specialities undertake percutaneous drainage but understanding of device performance outside radiology is often limited. Furthermore, the current catheter sizing using the “French” measurement of outer diameter is unhelpful; it does not reflect the internal diameter and gives no information on flow rate. To illustrate this and to improve catheter selection, notably for chest drainage, we assessed the variation of drain performance under standardised conditions. Internal diameter and flow rates of 6Fr.-12Fr. drainage catheters from 8 manufacturers were tested to ISO 10555-1 standard: Internal diameters were measured with Meyer calibrated pin-gauges. Flow rates were calculated over a period of 30s after achieving steady state. Evaluation demonstrated a wide range of internal diameters for the 6Fr., 8Fr., 10Fr. and 12Fr. catheters. Mean measurements were 1.49 mm (SD:0.07), 1.90 mm (SD:0.10), 2.43 mm (SD:0.11) and 2.64 mm (SD:0.03) respectively. Mean flow rates were 128 mL/min (SD:37.6), 207 mL/min (SD: 55.1), 291 mL/min (SD:36.7) and 303 mL/min (SD:20.2) respectively. There was such variance that there was overlap between catheters of different size: thin-walled 10Fr. drains performed better than 12Fr. “Seldinger” chest drains. Better understanding of drain characteristics and better declaration of performance data by manufacturers are required to allow optimum drain choice for individual patients and optimum outcomes.
- 10 January 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-7
Open AccessA standardised comparison of chest and percutaneous drainage catheters to evaluate the applicability of the ‘French’ sizing units
A variety of medical specialities undertake percutaneous drainage but understanding of device performance outside radiology is often limited. Furthermore, the current catheter sizing using the “French” measurement of outer diameter is unhelpful; it does not reflect the internal diameter and gives no information on flow rate. To illustrate this and to improve catheter selection, notably for chest drainage, we assessed the variation of drain performance under standardised conditions. Internal diameter and flow rates of 6Fr.-12Fr. drainage catheters from 8 manufacturers were tested to ISO 10555-1 standard: Internal diameters were measured with Meyer calibrated pin-gauges. Flow rates were calculated over a period of 30s after achieving steady state. Evaluation demonstrated a wide range of internal diameters for the 6Fr., 8Fr., 10Fr. and 12Fr. catheters. Mean measurements were 1.49 mm (SD:0.07), 1.90 mm (SD:0.10), 2.43 mm (SD:0.11) and 2.64 mm (SD:0.03) respectively. Mean flow rates were 128 mL/min (SD:37.6), 207 mL/min (SD: 55.1), 291 mL/min (SD:36.7) and 303 mL/min (SD:20.2) respectively. There was such variance that there was overlap between catheters of different size: thin-walled 10Fr. drains performed better than 12Fr. “Seldinger” chest drains. Better understanding of drain characteristics and better declaration of performance data by manufacturers are required to allow optimum drain choice for individual patients and optimum outcomes.
- 28 November 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (12) , 981
Unlicensed stent use creating the need for additional procedures
We congratulate Gupta et al. on managing to remove a partially covered Ultraflex stent after fixation by epithelial hyperplasia [1]. However, only fully covered removable stents are licensed for benign conditions. Specifically, this stent was used off-label contravening the specific instructions by the manufacturer, which clearly detail it is only for malignant strictures [2]. Can the authors state whether the stent was placed intentionally, and did the patient consent procedure cover this off-label application and the expected difficult removal? While coagulating the ingrowth is a useful adjunct in managing complications of esophageal stenting, using partially covered stents in benign conditions cannot be advocated as good practice. They are designed to allow epithelial hyperplasia for fixation and may be impossible to remove. This patient was put through four separate removal procedures, including two stent-in-stent placements with all their inherent risks. The stent-in-stent technique is problematic with an Ultraflex because of its unique tulip-shaped configuration that prevents good compression of the hyperplastic tissue. There are many fully covered, removable stents designed and licensed for temporary stenting of benign conditions, and also much easier to deploy. In the absence of an associated stricture, obviously an oversized or very conformable stent must be chosen. Many operators have little understanding of the wide range of devices and are limited to the stents sold by the suppliers of their endoscopic equipment. Users of the “covered” Ultraflex are commonly unaware it is only partially covered and not designed for removal. In our experience it is the stent with the most unmanageable late complications, precluding simple revision by exchange. In one case this led to death from aspiration pneumonia due to hyperplasia occluding the stent. This was after failed attempts at removal by the original operator and while awaiting stent-in-stent removal in our department. The book by Kozarek et al. [3] deals with all aspects of stenting and is essential reading. Article published online: 28 November 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 28 November 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (12) , 981
Unlicensed stent use creating the need for additional procedures
We congratulate Gupta et al. on managing to remove a partially covered Ultraflex stent after fixation by epithelial hyperplasia [1]. However, only fully covered removable stents are licensed for benign conditions. Specifically, this stent was used off-label contravening the specific instructions by the manufacturer, which clearly detail it is only for malignant strictures [2]. Can the authors state whether the stent was placed intentionally, and did the patient consent procedure cover this off-label application and the expected difficult removal? While coagulating the ingrowth is a useful adjunct in managing complications of esophageal stenting, using partially covered stents in benign conditions cannot be advocated as good practice. They are designed to allow epithelial hyperplasia for fixation and may be impossible to remove. This patient was put through four separate removal procedures, including two stent-in-stent placements with all their inherent risks. The stent-in-stent technique is problematic with an Ultraflex because of its unique tulip-shaped configuration that prevents good compression of the hyperplastic tissue. There are many fully covered, removable stents designed and licensed for temporary stenting of benign conditions, and also much easier to deploy. In the absence of an associated stricture, obviously an oversized or very conformable stent must be chosen. Many operators have little understanding of the wide range of devices and are limited to the stents sold by the suppliers of their endoscopic equipment. Users of the “covered” Ultraflex are commonly unaware it is only partially covered and not designed for removal. In our experience it is the stent with the most unmanageable late complications, precluding simple revision by exchange. In one case this led to death from aspiration pneumonia due to hyperplasia occluding the stent. This was after failed attempts at removal by the original operator and while awaiting stent-in-stent removal in our department. The book by Kozarek et al. [3] deals with all aspects of stenting and is essential reading. Article published online: 28 November 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 3 September 2024
- Published by Elsevier in Clinical Radiology
- Vol. 79 (12) , e1490-e1496
EEG bispectral index sensor guidance improves accuracy and safety of procedural sedation
- 3 September 2024
- Published by Elsevier in Clinical Radiology
- Vol. 79 (12) , e1490-e1496
EEG bispectral index sensor guidance improves accuracy and safety of procedural sedation
- Open Access
- 31 January 2024
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 13 (1) , 8-10
Safety of EEG BIS-guided nurse-administered procedural sedation during gastro-intestinal intervention
Alexander Oh, Sviatlana Vasileuskaya, Nabil Kibriya, Paula Puro, Damian Mullan, and Hans-Ulrich Laasch. Int J Gastrointest Interv 2024;13:8-10. https://doi.org/10.18528/ijgii240001
- 31 January 2024
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 13 (1) , 8-10
Open AccessSafety of EEG BIS-guided nurse-administered procedural sedation during gastro-intestinal intervention
Alexander Oh, Sviatlana Vasileuskaya, Nabil Kibriya, Paula Puro, Damian Mullan, and Hans-Ulrich Laasch. Int J Gastrointest Interv 2024;13:8-10. https://doi.org/10.18528/ijgii240001
- Open Access
- 21 December 2023
- Published by Springer Nature in Research Square
Standardised comparison of chest and percutaneous drainage catheters: Size is not everything
A variety of medical specialities undertake percutaneous drainage but understanding of device performance outside radiology is often limited. Furthermore, the current catheter sizing using the “French” measurement of outer diameter is unhelpful; it does not reflect the internal diameter and gives no information on flow rate. To illustrate this and to improve catheter selection, notably for chest drainage, we assessed the variation of drain performance under standardised conditions. Internal diameter and flow rates of 6Fr.-12Fr. drainage catheters from 7 manufacturers were tested to ISO 10555-1 standard: Internal diameters were measured with Meyer calibrated pin-gauges. Flow rates were calculated over a period of 30s after achieving steady state. Evaluation demonstrated a wide range of internal diameters for the 6Fr., 8Fr., 10Fr. and 12Fr. catheters. Mean measurements were 1.49mm (SD:0.07), 1.90mm (SD:0.10), 2.43mm (SD:0.11) and 2.64mm (SD:0.03) respectively. Mean flow rates were 128mL/min (SD:37.6), 207mL/min (SD: 55.1), 291mL/min (SD:36.7) and 303mL/min (SD:20.2) respectively. There was such variance that there was overlap between catheters of different size: thin-walled 10Fr. drains performed better than 12Fr. “Seldinger” chest drains. Better understanding of drain characteristics and better declaration of performance data by manufacturers are required to allow optimum drain choice for individual patients and optimum outcomes.
- 21 December 2023
- Published by Springer Nature in Research Square
Open AccessStandardised comparison of chest and percutaneous drainage catheters: Size is not everything
A variety of medical specialities undertake percutaneous drainage but understanding of device performance outside radiology is often limited. Furthermore, the current catheter sizing using the “French” measurement of outer diameter is unhelpful; it does not reflect the internal diameter and gives no information on flow rate. To illustrate this and to improve catheter selection, notably for chest drainage, we assessed the variation of drain performance under standardised conditions. Internal diameter and flow rates of 6Fr.-12Fr. drainage catheters from 7 manufacturers were tested to ISO 10555-1 standard: Internal diameters were measured with Meyer calibrated pin-gauges. Flow rates were calculated over a period of 30s after achieving steady state. Evaluation demonstrated a wide range of internal diameters for the 6Fr., 8Fr., 10Fr. and 12Fr. catheters. Mean measurements were 1.49mm (SD:0.07), 1.90mm (SD:0.10), 2.43mm (SD:0.11) and 2.64mm (SD:0.03) respectively. Mean flow rates were 128mL/min (SD:37.6), 207mL/min (SD: 55.1), 291mL/min (SD:36.7) and 303mL/min (SD:20.2) respectively. There was such variance that there was overlap between catheters of different size: thin-walled 10Fr. drains performed better than 12Fr. “Seldinger” chest drains. Better understanding of drain characteristics and better declaration of performance data by manufacturers are required to allow optimum drain choice for individual patients and optimum outcomes.
- Open Access
Influence of the Manufacturing Process on the Corrosion and Mechanical Behavior of Esophageal Stents
Esophageal nitinol stents are an established method for treating swallowing difficulties caused by obstructing cancer. This raesearch investigates the influence of different qualities of raw metal alloys in combination with production technology on corrosion resistance in standardized simulated gastric fluid (SGF). Four different international stent manufacturers produced samples of their standard stents from nitinol sourced from three different alloy manufacturers. The stents were subjected to a 6-week immersion in SGF. During the immersion, the surface was studied at specified intervals using microscopy. The surface of the samples was also studied by X-ray Photoelectron Spectroscopy and after immersion the released ions were analyzed. Results demonstrated that both raw material and certain steps in the manufacturing process negatively affect corrosion resistance. Analysis of the SGF showed that the amount of nickel released is proportional to the degree of corrosion attack. Finally, current accepted standard test methods are inadequate for assessing susceptibility to corrosion by gastric acid and should take the low pH of the implanted environment into account. Conversely, certain measures in the manufacturing process are able to reduce the impact of the base material on corrosion susceptibility.
Open AccessInfluence of the Manufacturing Process on the Corrosion and Mechanical Behavior of Esophageal Stents
Esophageal nitinol stents are an established method for treating swallowing difficulties caused by obstructing cancer. This raesearch investigates the influence of different qualities of raw metal alloys in combination with production technology on corrosion resistance in standardized simulated gastric fluid (SGF). Four different international stent manufacturers produced samples of their standard stents from nitinol sourced from three different alloy manufacturers. The stents were subjected to a 6-week immersion in SGF. During the immersion, the surface was studied at specified intervals using microscopy. The surface of the samples was also studied by X-ray Photoelectron Spectroscopy and after immersion the released ions were analyzed. Results demonstrated that both raw material and certain steps in the manufacturing process negatively affect corrosion resistance. Analysis of the SGF showed that the amount of nickel released is proportional to the degree of corrosion attack. Finally, current accepted standard test methods are inadequate for assessing susceptibility to corrosion by gastric acid and should take the low pH of the implanted environment into account. Conversely, certain measures in the manufacturing process are able to reduce the impact of the base material on corrosion susceptibility.
- Open Access
- 30 April 2022
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 11 (2) , 89-93
Distal migration of a partially covered duodenal stent requiring emergency surgical extraction
Luca Giovanni Campana, Rebecca Fish, Owen Thomas Dickinson, Mairéad Geraldine McNamara, Sarah Theresa O’Dwyer, and Hans-Ulrich Laasch. Int J Gastrointest Interv 2022;11:89-93. https://doi.org/10.18528/ijgii210044
- 30 April 2022
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 11 (2) , 89-93
Open AccessDistal migration of a partially covered duodenal stent requiring emergency surgical extraction
Luca Giovanni Campana, Rebecca Fish, Owen Thomas Dickinson, Mairéad Geraldine McNamara, Sarah Theresa O’Dwyer, and Hans-Ulrich Laasch. Int J Gastrointest Interv 2022;11:89-93. https://doi.org/10.18528/ijgii210044
- Open Access
- 26 March 2021
- Published by Springer Nature in Cureus
- Vol. 13 (3)
Retrograde Radiological Gastrostomy Technique and Retrograde Stent Placement in a Completely Occluded Cervical Esophagus
Malignant obstruction of the cervical esophagus presents some anatomical and technical challenges when considering radiologic or endoscopic intervention. This case report describes the failure of antegrade access to place a gastrostomy tube and stent due to complete luminal occlusion from an esophageal tumor. The ultrasound-guided percutaneous gastric puncture was performed to achieve retrograde pneumodistension to allow radiologic gastrostomy insertion. Subsequently, the cervical esophagus was retrogradely cannulated via insertion of a guidewire from the gastrostomy site. A distal release esophageal stent was then inserted over the wire and deployed from the mouth in an antegrade manner. However, due to the unpredictable proximal shortening of distal release stents, this stent was eventually shortened and displaced so that it no longer covered the top of the tumor stricture, and further antegrade access failed. Once more, a retrograde access approach was adopted via the gastrostomy stoma, a guidewire and catheter were passed retrogradely through the original stent and out through the mouth. A distal release stent system was then inserted in a retrograde manner via the gastrostomy stoma, effectively making it a proximal release stent which enabled more precise positioning of the stent above the tumor. Palliation was achieved until death, and beyond expected mean survival.
- 26 March 2021
- Published by Springer Nature in Cureus
- Vol. 13 (3)
Open AccessRetrograde Radiological Gastrostomy Technique and Retrograde Stent Placement in a Completely Occluded Cervical Esophagus
Malignant obstruction of the cervical esophagus presents some anatomical and technical challenges when considering radiologic or endoscopic intervention. This case report describes the failure of antegrade access to place a gastrostomy tube and stent due to complete luminal occlusion from an esophageal tumor. The ultrasound-guided percutaneous gastric puncture was performed to achieve retrograde pneumodistension to allow radiologic gastrostomy insertion. Subsequently, the cervical esophagus was retrogradely cannulated via insertion of a guidewire from the gastrostomy site. A distal release esophageal stent was then inserted over the wire and deployed from the mouth in an antegrade manner. However, due to the unpredictable proximal shortening of distal release stents, this stent was eventually shortened and displaced so that it no longer covered the top of the tumor stricture, and further antegrade access failed. Once more, a retrograde access approach was adopted via the gastrostomy stoma, a guidewire and catheter were passed retrogradely through the original stent and out through the mouth. A distal release stent system was then inserted in a retrograde manner via the gastrostomy stoma, effectively making it a proximal release stent which enabled more precise positioning of the stent above the tumor. Palliation was achieved until death, and beyond expected mean survival.