Ashwin Belle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ashwin Belle has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Kayvan Najarian
School of Engineering, Virginia Commonwealth University
7 shared publications- Kayvan Najarian
Gilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, USA
6 shared publications - Kevin R. Ward
Department of Emergency Medicine, University of Michigan, Ann Arbor, USA
4 shared publications Kevin Ward
Department of Emergency Medicine and VCU Reanimation Engineering Shock Center, Virginia Commonwealth University, Richmond VA, USA
3 shared publicationsSardar Ansari
Computer Science Department, Virginia Commonwealth University, Richmond VA, USA
3 shared publicationsAshish K. Khanna
Affiliation Department of Anesthesiology, Section on Critical Care Medicine, Perioperative Outcomes and Informatics Collaborative (POIC), Wake Forest School of Medicine, Atrium Health Wake Forest Baptist, Winston-Salem, North Carolina, United States of America
2 shared publications
Latest Publications
- Open Access
- 24 October 2024
- Published by Public Library of Science (PLoS) in PLOS Digital Health
- Vol. 3 (10) , e0000465
Use of a continuous single lead electrocardiogram analytic to predict patient deterioration requiring rapid response team activation
Identifying the onset of patient deterioration is challenging despite the potential to respond to patients earlier with better vital sign monitoring and rapid response team (RRT) activation. In this study an ECG based software as a medical device, the Analytic for Hemodynamic Instability Predictive Index (AHI-PI), was compared to the vital signs of heart rate, blood pressure, and respiratory rate, evaluating how early it indicated risk before an RRT activation. A higher proportion of the events had risk indication by AHI-PI (92.71%) than by vital signs (41.67%). AHI-PI indicated risk early, with an average of over a day before RRT events. In events whose risks were indicated by both AHI-PI and vital signs, AHI-PI demonstrated earlier recognition of deterioration compared to vital signs. A case-control study showed that situations requiring RRTs were more likely to have AHI-PI risk indication than those that did not. The study derived several insights in support of AHI-PI’s efficacy as a clinical decision support system. The findings demonstrated AHI-PI’s potential to serve as a reliable predictor of future RRT events. It could potentially help clinicians recognize early clinical deterioration and respond to those unnoticed by vital signs, thereby helping clinicians improve clinical outcomes.
- 24 October 2024
- Published by Public Library of Science (PLoS) in PLOS Digital Health
- Vol. 3 (10) , e0000465
Open AccessUse of a continuous single lead electrocardiogram analytic to predict patient deterioration requiring rapid response team activation
Identifying the onset of patient deterioration is challenging despite the potential to respond to patients earlier with better vital sign monitoring and rapid response team (RRT) activation. In this study an ECG based software as a medical device, the Analytic for Hemodynamic Instability Predictive Index (AHI-PI), was compared to the vital signs of heart rate, blood pressure, and respiratory rate, evaluating how early it indicated risk before an RRT activation. A higher proportion of the events had risk indication by AHI-PI (92.71%) than by vital signs (41.67%). AHI-PI indicated risk early, with an average of over a day before RRT events. In events whose risks were indicated by both AHI-PI and vital signs, AHI-PI demonstrated earlier recognition of deterioration compared to vital signs. A case-control study showed that situations requiring RRTs were more likely to have AHI-PI risk indication than those that did not. The study derived several insights in support of AHI-PI’s efficacy as a clinical decision support system. The findings demonstrated AHI-PI’s potential to serve as a reliable predictor of future RRT events. It could potentially help clinicians recognize early clinical deterioration and respond to those unnoticed by vital signs, thereby helping clinicians improve clinical outcomes.
- Open Access
Use of a Continuous Single Lead Electrocardiogram Analytic to Predict Patient Deterioration Requiring Rapid Response Team Activation
Identifying the onset of patient deterioration is challenging despite the potential to respond to patients earlier with better vital sign monitoring and rapid response team (RRT) activation. In this study an ECG based software as a medical device, the Analytic for Hemodynamic Instability Predictive Index (AHI-PI), was compared to the vital signs of heart rate, blood pressure, and respiratory rate, evaluating how early it indicated risk before an RRT activation. A higher proportion of the events had risk indication by AHI-PI (92.71%) than by vital signs (41.67%). AHI-PI indicated risk early, with an average of over a day before RRT events. In events whose risks were indicated by both AHI-PI and vital signs, AHI-PI demonstrated earlier recognition of deterioration compared to vital signs. A case-control study showed that situations requiring RRTs were more likely to have AHI-PI risk indication than those that did not. The study derived several insights in support of AHI-PI’s efficacy as a clinical decision support system. The findings demonstrated AHI-PI’s potential to serve as a reliable predictor of future RRT events. It could potentially help clinicians recognize early clinical deterioration and respond to those unnoticed by vital signs, thereby helping clinicians improve clinical outcomes. Author Summary Recognizing patient deterioration remains challenging even for experienced clinicians and nurses. RRTs can help mobilize resources to respond to patients earlier. However, determining when to activate RRTs is difficult. We retrospectively evaluated a software as a medical device, AHI-PI, compared the vital signs of heart rate, blood pressure, and respiratory rate to understand if AHI-PI could provide an earlier indicator of patient deterioration than vital signs. Our findings demonstrated AHI-PI’s potential to serve as a reliable predictor of future RRT events, before vital sign changes occur. This could potentially help clinicians recognize patients at risk for clinical deterioration and improve clinical outcomes through early targeted therapy or interventions.
Open AccessUse of a Continuous Single Lead Electrocardiogram Analytic to Predict Patient Deterioration Requiring Rapid Response Team Activation
Identifying the onset of patient deterioration is challenging despite the potential to respond to patients earlier with better vital sign monitoring and rapid response team (RRT) activation. In this study an ECG based software as a medical device, the Analytic for Hemodynamic Instability Predictive Index (AHI-PI), was compared to the vital signs of heart rate, blood pressure, and respiratory rate, evaluating how early it indicated risk before an RRT activation. A higher proportion of the events had risk indication by AHI-PI (92.71%) than by vital signs (41.67%). AHI-PI indicated risk early, with an average of over a day before RRT events. In events whose risks were indicated by both AHI-PI and vital signs, AHI-PI demonstrated earlier recognition of deterioration compared to vital signs. A case-control study showed that situations requiring RRTs were more likely to have AHI-PI risk indication than those that did not. The study derived several insights in support of AHI-PI’s efficacy as a clinical decision support system. The findings demonstrated AHI-PI’s potential to serve as a reliable predictor of future RRT events. It could potentially help clinicians recognize early clinical deterioration and respond to those unnoticed by vital signs, thereby helping clinicians improve clinical outcomes. Author Summary Recognizing patient deterioration remains challenging even for experienced clinicians and nurses. RRTs can help mobilize resources to respond to patients earlier. However, determining when to activate RRTs is difficult. We retrospectively evaluated a software as a medical device, AHI-PI, compared the vital signs of heart rate, blood pressure, and respiratory rate to understand if AHI-PI could provide an earlier indicator of patient deterioration than vital signs. Our findings demonstrated AHI-PI’s potential to serve as a reliable predictor of future RRT events, before vital sign changes occur. This could potentially help clinicians recognize patients at risk for clinical deterioration and improve clinical outcomes through early targeted therapy or interventions.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23258861,p. 1181-1184
Multi-modal integrated approach towards reducing false arrhythmia alarms during continuous patient monitoring: The Physionet Challenge 2015
This work presents a solution for the Physionet Challenge 2015 regarding false alarm reduction in ICU. False alarms can result in alarm fatigue, i.e. reduced responsiveness of the ICU personnel to the true alarms due to an enormous number of false alarms. As a result, it is necessary to effectively suppress the false alarms while ensuring that the true alarms are not ignored. The challenge data contains five different types of alarms which are treated as independent problems in this paper. A separate subroutine is used for each alarm which is composed of two stages, peak detection and alarm verification. This paper uses a multi-modal peak detection algorithm that uses the information from all the available signals and combines the results from several peak detection algorithms to create a robust peak detection algorithm. The alarm verification stage is alarm dependent, composed of simple decision criteria or a complicated neural network model. The proposed approach achieves an overall score of 74.48 for the real-time event, where only the portions of the signals prior to the alarm are utilized, and 76.57 for the retrospective event, where 30 seconds of the signals after the alarm are used as well.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23258861,p. 1181-1184
Multi-modal integrated approach towards reducing false arrhythmia alarms during continuous patient monitoring: The Physionet Challenge 2015
This work presents a solution for the Physionet Challenge 2015 regarding false alarm reduction in ICU. False alarms can result in alarm fatigue, i.e. reduced responsiveness of the ICU personnel to the true alarms due to an enormous number of false alarms. As a result, it is necessary to effectively suppress the false alarms while ensuring that the true alarms are not ignored. The challenge data contains five different types of alarms which are treated as independent problems in this paper. A separate subroutine is used for each alarm which is composed of two stages, peak detection and alarm verification. This paper uses a multi-modal peak detection algorithm that uses the information from all the available signals and combines the results from several peak detection algorithms to create a robust peak detection algorithm. The alarm verification stage is alarm dependent, composed of simple decision criteria or a complicated neural network model. The proposed approach achieves an overall score of 74.48 for the real-time event, where only the portions of the signals prior to the alarm are utilized, and 76.57 for the retrospective event, where 30 seconds of the signals after the alarm are used as well.
- 10 December 2013
- Published by Springer Nature
- p. 229-259
Rule-based Computer Aided Decision Making for Traumatic Brain Injuries
- 10 December 2013
- Published by Springer Nature
- p. 229-259
Rule-based Computer Aided Decision Making for Traumatic Brain Injuries
- Open Access
- 13 April 2013
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 74,p. e3871
Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
In this paper we present an automated system based mainly on the computed tomography (CT) images consisting of two main components: the midline shift estimation and intracranial pressure (ICP) pre-screening system. To estimate the midline shift, first an estimation of the ideal midline is performed based on the symmetry of the skull and anatomical features in the brain CT scan. Then, segmentation of the ventricles from the CT scan is performed and used as a guide for the identification of the actual midline through shape matching. These processes mimic the measuring process by physicians and have shown promising results in the evaluation. In the second component, more features are extracted related to ICP, such as the texture information, blood amount from CT scans and other recorded features, such as age, injury severity score to estimate the ICP are also incorporated. Machine learning techniques including feature selection and classification, such as Support Vector Machines (SVMs), are employed to build the prediction model using RapidMiner. The evaluation of the prediction shows potential usefulness of the model. The estimated ideal midline shift and predicted ICP levels may be used as a fast pre-screening step for physicians to make decisions, so as to recommend for or against invasive ICP monitoring.
- 13 April 2013
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 74,p. e3871
Open AccessAutomated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
In this paper we present an automated system based mainly on the computed tomography (CT) images consisting of two main components: the midline shift estimation and intracranial pressure (ICP) pre-screening system. To estimate the midline shift, first an estimation of the ideal midline is performed based on the symmetry of the skull and anatomical features in the brain CT scan. Then, segmentation of the ventricles from the CT scan is performed and used as a guide for the identification of the actual midline through shape matching. These processes mimic the measuring process by physicians and have shown promising results in the evaluation. In the second component, more features are extracted related to ICP, such as the texture information, blood amount from CT scans and other recorded features, such as age, injury severity score to estimate the ICP are also incorporated. Machine learning techniques including feature selection and classification, such as Support Vector Machines (SVMs), are employed to build the prediction model using RapidMiner. The evaluation of the prediction shows potential usefulness of the model. The estimated ideal midline shift and predicted ICP levels may be used as a fast pre-screening step for physicians to make decisions, so as to recommend for or against invasive ICP monitoring.
- 1 February 2013
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 27 (3) , 289-302
Heart rate variability analysis during central hypovolemia using wavelet transformation
Detection of hypovolemia prior to overt hemodynamic decompensation remains an elusive goal in the treatment of critically injured patients in both civilian and combat settings. Monitoring of heart rate variability has been advocated as a potential means to monitor the rapid changes in the physiological state of hemorrhaging patients, with the most popular methods involving calculation of the R–R interval signal’s power spectral density (PSD) or use of fractal dimensions (FD). However, the latter method poses technical challenges, while the former is best suited to stationary signals rather than the non-stationary R–R interval. Both approaches are also limited by high inter- and intra-individual variability, a serious issue when applying these indices to the clinical setting. We propose an approach which applies the discrete wavelet transform (DWT) to the R–R interval signal to extract information at both 500 and 125 Hz sampling rates. The utility of machine learning models based on these features were tested in assessing electrocardiogram signals from volunteers subjected to lower body negative pressure induced central hypovolemia as a surrogate of hemorrhage. These machine learning models based on DWT features were compared against those based on the traditional PSD and FD, at both sampling rates and their performance was evaluated based on leave-one-subject-out fold cross-validation. Results demonstrate that the proposed DWT-based model outperforms individual PSD and FD methods as well as the combination of these two traditional methods at both sample rates of 500 Hz (p value p value <0.0001) in detecting the degree of hypovolemia. These findings indicate the potential of the proposed DWT approach in monitoring the physiological changes caused by hemorrhage. The speed and relatively low computational costs in deriving these features may make it particularly suited for implementation in portable devices for remote monitoring.
- 1 February 2013
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 27 (3) , 289-302
Heart rate variability analysis during central hypovolemia using wavelet transformation
Detection of hypovolemia prior to overt hemodynamic decompensation remains an elusive goal in the treatment of critically injured patients in both civilian and combat settings. Monitoring of heart rate variability has been advocated as a potential means to monitor the rapid changes in the physiological state of hemorrhaging patients, with the most popular methods involving calculation of the R–R interval signal’s power spectral density (PSD) or use of fractal dimensions (FD). However, the latter method poses technical challenges, while the former is best suited to stationary signals rather than the non-stationary R–R interval. Both approaches are also limited by high inter- and intra-individual variability, a serious issue when applying these indices to the clinical setting. We propose an approach which applies the discrete wavelet transform (DWT) to the R–R interval signal to extract information at both 500 and 125 Hz sampling rates. The utility of machine learning models based on these features were tested in assessing electrocardiogram signals from volunteers subjected to lower body negative pressure induced central hypovolemia as a surrogate of hemorrhage. These machine learning models based on DWT features were compared against those based on the traditional PSD and FD, at both sampling rates and their performance was evaluated based on leave-one-subject-out fold cross-validation. Results demonstrate that the proposed DWT-based model outperforms individual PSD and FD methods as well as the combination of these two traditional methods at both sample rates of 500 Hz (p value p value <0.0001) in detecting the degree of hypovolemia. These findings indicate the potential of the proposed DWT approach in monitoring the physiological changes caused by hemorrhage. The speed and relatively low computational costs in deriving these features may make it particularly suited for implementation in portable devices for remote monitoring.
- Open Access
- 1 January 2013
- Published by Wiley in The Scientific World Journal
- Vol. 2013 (1) , 896056
A Hierarchical Method for Removal of Baseline Drift from Biomedical Signals: Application in ECG Analysis
Noise can compromise the extraction of some fundamental and important features from biomedical signals and hence prohibit accurate analysis of these signals. Baseline wander in electrocardiogram (ECG) signals is one such example, which can be caused by factors such as respiration, variations in electrode impedance, and excessive body movements. Unless baseline wander is effectively removed, the accuracy of any feature extracted from the ECG, such as timing and duration of the ST‐segment, is compromised. This paper approaches this filtering task from a novel standpoint by assuming that the ECG baseline wander comes from an independent and unknown source. The technique utilizes a hierarchical method including a blind source separation (BSS) step, in particular independent component analysis, to eliminate the effect of the baseline wander. We examine the specifics of the components causing the baseline wander and the factors that affect the separation process. Experimental results reveal the superiority of the proposed algorithm in removing the baseline wander.
- 1 January 2013
- Published by Wiley in The Scientific World Journal
- Vol. 2013 (1) , 896056
Open AccessA Hierarchical Method for Removal of Baseline Drift from Biomedical Signals: Application in ECG Analysis
Noise can compromise the extraction of some fundamental and important features from biomedical signals and hence prohibit accurate analysis of these signals. Baseline wander in electrocardiogram (ECG) signals is one such example, which can be caused by factors such as respiration, variations in electrode impedance, and excessive body movements. Unless baseline wander is effectively removed, the accuracy of any feature extracted from the ECG, such as timing and duration of the ST‐segment, is compromised. This paper approaches this filtering task from a novel standpoint by assuming that the ECG baseline wander comes from an independent and unknown source. The technique utilizes a hierarchical method including a blind source separation (BSS) step, in particular independent component analysis, to eliminate the effect of the baseline wander. We examine the specifics of the components causing the baseline wander and the factors that affect the separation process. Experimental results reveal the superiority of the proposed algorithm in removing the baseline wander.
- Open Access
- 1 January 2013
- Published by Wiley in The Scientific World Journal
- Vol. 2013 (1) , 769639
Biomedical Informatics for Computer‐Aided Decision Support Systems: A Survey
The volumes of current patient data as well as their complexity make clinical decision making more challenging than ever for physicians and other care givers. This situation calls for the use of biomedical informatics methods to process data and form recommendations and/or predictions to assist such decision makers. The design, implementation, and use of biomedical informatics systems in the form of computer‐aided decision support have become essential and widely used over the last two decades. This paper provides a brief review of such systems, their application protocols and methodologies, and the future challenges and directions they suggest.
- 1 January 2013
- Published by Wiley in The Scientific World Journal
- Vol. 2013 (1) , 769639
Open AccessBiomedical Informatics for Computer‐Aided Decision Support Systems: A Survey
The volumes of current patient data as well as their complexity make clinical decision making more challenging than ever for physicians and other care givers. This situation calls for the use of biomedical informatics methods to process data and form recommendations and/or predictions to assist such decision makers. The design, implementation, and use of biomedical informatics systems in the form of computer‐aided decision support have become essential and widely used over the last two decades. This paper provides a brief review of such systems, their application protocols and methodologies, and the future challenges and directions they suggest.
- Open Access
- 1 January 2013
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2013, 1-10
An Entropy-Based Automated Cell Nuclei Segmentation and Quantification: Application in Analysis of Wound Healing Process
The segmentation and quantification of cell nuclei are two very significant tasks in the analysis of histological images. Accurate results of cell nuclei segmentation are often adapted to a variety of applications such as the detection of cancerous cell nuclei and the observation of overlapping cellular events occurring during wound healing process in the human body. In this paper, an automated entropy-based thresholding system for segmentation and quantification of cell nuclei from histologically stained images has been presented. The proposed translational computation system aims to integrate clinical insight and computational analysis by identifying and segmenting objects of interest within histological images. Objects of interest and background regions are automatically distinguished by dynamically determining 3 optimal threshold values for the 3 color components of an input image. The threshold values are determined by means of entropy computations that are based on probability distributions of the color intensities of pixels and the spatial similarity of pixel intensities within neighborhoods. The effectiveness of the proposed system was tested over 21 histologically stained images containing approximately 1800 cell nuclei, and the overall performance of the algorithm was found to be promising, with high accuracy and precision values.
- 1 January 2013
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2013, 1-10
Open AccessAn Entropy-Based Automated Cell Nuclei Segmentation and Quantification: Application in Analysis of Wound Healing Process
The segmentation and quantification of cell nuclei are two very significant tasks in the analysis of histological images. Accurate results of cell nuclei segmentation are often adapted to a variety of applications such as the detection of cancerous cell nuclei and the observation of overlapping cellular events occurring during wound healing process in the human body. In this paper, an automated entropy-based thresholding system for segmentation and quantification of cell nuclei from histologically stained images has been presented. The proposed translational computation system aims to integrate clinical insight and computational analysis by identifying and segmenting objects of interest within histological images. Objects of interest and background regions are automatically distinguished by dynamically determining 3 optimal threshold values for the 3 color components of an input image. The threshold values are determined by means of entropy computations that are based on probability distributions of the color intensities of pixels and the spatial similarity of pixel intensities within neighborhoods. The effectiveness of the proposed system was tested over 21 histologically stained images containing approximately 1800 cell nuclei, and the overall performance of the algorithm was found to be promising, with high accuracy and precision values.
- Open Access
- 9 August 2012
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2012, 1-12
An Automated Optimal Engagement and Attention Detection System Using Electrocardiogram
This research proposes to develop a monitoring system which uses Electrocardiograph (ECG) as a fundamental physiological signal, to analyze and predict the presence or lack of cognitive attention in individuals during a task execution. The primary focus of this study is to identify the correlation between fluctuating level of attention and its implications on the cardiac rhythm recorded in the ECG. Furthermore, Electroencephalograph (EEG) signals are also analyzed and classified for use as a benchmark for comparison with ECG analysis. Several advanced signal processing techniques have been implemented and investigated to derive multiple clandestine and informative features from both these physiological signals. Decomposition and feature extraction are done using Stockwell-transform for the ECG signal, while Discrete Wavelet Transform (DWT) is used for EEG. These features are then applied to various machine-learning algorithms to produce classification models that are capable of differentiating between the cases of a person being attentive and a person not being attentive. The presented results show that detection and classification of cognitive attention using ECG are fairly comparable to EEG.
- 9 August 2012
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2012, 1-12
Open AccessAn Automated Optimal Engagement and Attention Detection System Using Electrocardiogram
This research proposes to develop a monitoring system which uses Electrocardiograph (ECG) as a fundamental physiological signal, to analyze and predict the presence or lack of cognitive attention in individuals during a task execution. The primary focus of this study is to identify the correlation between fluctuating level of attention and its implications on the cardiac rhythm recorded in the ECG. Furthermore, Electroencephalograph (EEG) signals are also analyzed and classified for use as a benchmark for comparison with ECG analysis. Several advanced signal processing techniques have been implemented and investigated to derive multiple clandestine and informative features from both these physiological signals. Decomposition and feature extraction are done using Stockwell-transform for the ECG signal, while Discrete Wavelet Transform (DWT) is used for EEG. These features are then applied to various machine-learning algorithms to produce classification models that are capable of differentiating between the cases of a person being attentive and a person not being attentive. The presented results show that detection and classification of cognitive attention using ECG are fairly comparable to EEG.