JLJakob Heydorn Lagerlöf

Jakob Heydorn Lagerlöf

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jakob Heydorn Lagerlöf has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Peter Bernhardt

    Department of Radiation Physics, University of Gothenburg, Gothenburg, Sweden

    9 shared publications
  • Jon Kindblom

    Department of Oncology, Sahlgrenska University Hospital, Göteborg 41345, Sweden

    4 shared publications
  • Peter Tarnow

    4 shared publications
  • Giovanni Maltese

    From the Departments of *Plastic Surgery, and †Radiation Physics, Institute for Clinical Sciences, Sahlgrenska Academy, Göteborg University, Sahlgrenska University Hospital, Göteborg, Sweden

    3 shared publications
  • Lars Kölby

    Department of Plastic Surgery, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg

    3 shared publications
  • Annelie Lindström

    Department of Radiation Physics, Göteborg University, Göteborg, Sweden

    2 shared publications

Latest Publications

  • Open Access

    Comparison of Otsu and an adapted Chan–Vese method to determine thyroid active volume using Monte Carlo generated SPECT images

    by Jonas Högberg, Christoffer Andersén, Tobias Rydén, Jakob H. Lagerlöf

    Background: The Otsu method and the Chan–Vese model are two methods proven to perform well in determining volumes of different organs and specific tissue fractions. This study aimed to compare the performance of the two methods regarding segmentation of active thyroid gland volumes, reflecting different clinical settings by varying the parameters: gland size, gland activity concentration, background activity concentration and gland activity concentration heterogeneity. Methods: A computed tomography was performed on three playdough thyroid phantoms with volumes 20, 35 and 50 ml. The image data were separated into playdough and water based on Hounsfield values. Sixty single photon emission computed tomography (SPECT) projections were simulated by Monte Carlo method with isotope Technetium-99 m ( $$^{\text {99m}}$$ 99m Tc). Linear combinations of SPECT images were made, generating 12 different combinations of volume and background: each with both homogeneous thyroid activity concentration and three hotspots of different relative activity concentrations (48 SPECT images in total). The relative background levels chosen were 5 %, 10 %, 15 % and 20 % of the phantom activity concentration and the hotspot activities were 100 % (homogeneous case) 150 %, 200 % and 250 %. Poisson noise, (coefficient of variation of 0.8 at a 20 % background level, scattering excluded), was added before reconstruction was done with the Monte Carlo-based SPECT reconstruction algorithm Sahlgrenska Academy reconstruction code (SARec). Two different segmentation algorithms were applied: Otsu’s threshold selection method and an adaptation of the Chan–Vese model for active contours without edges; the results were evaluated concerning relative volume, mean absolute error and standard deviation per thyroid volume, as well as dice similarity coefficient. Results: Both methods segment the images well and deviate similarly from the true volumes. They seem to slightly overestimate small volumes and underestimate large ones. Different background levels affect the two methods similarly as well. However, the Chan–Vese model deviates less and paired t-testing showed significant difference between distributions of dice similarity coefficients (p-value $$<0.01$$ < 0.01 ). Conclusions: The investigations indicate that the Chan–Vese model performs better and is slightly more robust, while being more challenging to implement and use clinically. There is a trade-off between performance and user-friendliness.


  • Open Access

    Computational study of the effect of hypoxia on cancer response to radiation treatment

    by T. Korhonen, J. H. Lagerlöf, A. Muntean

    We perform a computational study of the propagation of the oxygen concentration within a two-dimensional slice of a heterogeneous tumour region where the position and shape of the blood vessels are known. Exploiting the parameters space, we explore which effect is noticeable what concerns the formation of hypoxic zones. We use this information to anticipate a patient-specific radiation treatment with controlled response of the cancer growth.

  • Open Access

    Oxygen Distributions—Evaluation of Computational Methods, Using a Stochastic Model for Large Tumour Vasculature, to Elucidate the Importance of Considering a Complete Vascular Network

    by Jakob H. Lagerlöf, Peter Bernhardt

    To develop a general model that utilises a stochastic method to generate a vessel tree based on experimental data, and an associated irregular, macroscopic tumour. These will be used to evaluate two different methods for computing oxygen distribution. A vessel tree structure, and an associated tumour of 127 cm3, were generated, using a stochastic method and Bresenham’s line algorithm to develop trees on two different scales and fusing them together. The vessel dimensions were adjusted through convolution and thresholding and each vessel voxel was assigned an oxygen value. Diffusion and consumption were modelled using a Green’s function approach together with Michaelis-Menten kinetics. The computations were performed using a combined tree method (CTM) and an individual tree method (ITM). Five tumour sub-sections were compared, to evaluate the methods. The oxygen distributions of the same tissue samples, using different methods of computation, were considerably less similar (root mean square deviation, RMSD≈0.02) than the distributions of different samples using CTM (0.001< RMSD<0.01). The deviations of ITM from CTM increase with lower oxygen values, resulting in ITM severely underestimating the level of hypoxia in the tumour. Kolmogorov Smirnov (KS) tests showed that millimetre-scale samples may not represent the whole. The stochastic model managed to capture the heterogeneous nature of hypoxic fractions and, even though the simplified computation did not considerably alter the oxygen distribution, it leads to an evident underestimation of tumour hypoxia, and thereby radioresistance. For a trustworthy computation of tumour oxygenation, the interaction between adjacent microvessel trees must not be neglected, why evaluation should be made using high resolution and the CTM, applied to the entire tumour.

  • Open Access

    Oxygen distribution in tumors: A qualitative analysis and modeling study providing a novel Monte Carlo approach

    by Jakob H. Lagerlöf, Jon Kindblom, Peter Bernhardt

    Purpose:: To construct a Monte Carlo (MC)‐based simulation model for analyzing the dependence of tumor oxygen distribution on different variables related to tumor vasculature [blood velocity, vessel‐to‐vessel proximity (vessel proximity), and inflowing oxygen partial pressure (pO2)].Methods:: A voxel‐based tissue model containing parallel capillaries with square cross‐sections (sides of 10 μm) was constructed. Greenˈs function was used for diffusion calculations and Michaelis‐Mentenˈs kinetics to manage oxygen consumption. The model was tuned to approximately reproduce the oxygenational status of a renal carcinoma; the depth oxygenation curves (DOC) were fitted with an analytical expression to facilitate rapid MC simulations of tumor oxygen distribution. DOCs were simulated with three variables at three settings each (blood velocity, vessel proximity, and inflowing pO2), which resulted in 27 combinations of conditions. To create a model that simulated variable oxygen distributions, the oxygen tension at a specific point was randomly sampled with trilinear interpolation in the dataset from the first simulation. Six correlations between blood velocity, vessel proximity, and inflowing pO2 were hypothesized. Variable models with correlated parameters were compared to each other and to a nonvariable, DOC‐based model to evaluate the differences in simulated oxygen distributions and tumor radiosensitivities for different tumor sizes.Results:: For tumors with radii ranging from 5 to 30 mm, the nonvariable DOC model tended to generate normal or log‐normal oxygen distributions, with a cut‐off at zero. The pO2 distributions simulated with the six‐variable DOC models were quite different from the distributions generated with the nonvariable DOC model; in the former case the variable models simulated oxygen distributions that were more similar to in vivo results found in the literature. For larger tumors, the oxygen distributions became truncated in the lower end, due to anoxia, but smaller tumors showed undisturbed oxygen distributions. The six different models with correlated parameters generated three classes of oxygen distributions. The first was a hypothetical, negative covariance between vessel proximity and pO2 (VPO‐C scenario); the second was a hypothetical positive covariance between vessel proximity and pO2 (VPO+C scenario); and the third was the hypothesis of no correlation between vessel proximity and pO2 (UP scenario). The VPO‐C scenario produced a distinctly different oxygen distribution than the two other scenarios. The shape of the VPO‐C scenario was similar to that of the nonvariable DOC model, and the larger the tumor, the greater the similarity between the two models. For all simulations, the mean oxygen tension decreased and the hypoxic fraction increased with tumor size. The absorbed dose required for definitive tumor control was highest for the VPO+C scenario, followed by the UP and VPO‐C scenarios.Conclusions:: A novel MC algorithm was presented which simulated oxygen distributions and radiation response for various biological parameter values. The analysis showed that the VPO‐C scenario generated a clearly different oxygen distribution from the VPO+C scenario; the former exhibited a lower hypoxic fraction and higher radiosensitivity. In future studies, this modeling approach might be valuable for qualitative analyses of factors that affect oxygen distribution as well as analyses of specific experimental and clinical situations.


  • The impact of including spatially longitudinal heterogeneities of vessel oxygen content and vascular fraction in 3D tumor oxygenation models on predicted radiation sensitivity

    by Jakob H. Lagerlöf, Jon Kindblom, Peter Bernhardt

    Purpose:: Oxygen distribution models have been used to analyze the influences of oxygen tensions on tissue response after radiotherapy. These distributions are often generated assuming constant oxygen tension in the blood vessels. However, as red blood cells progress through the vessels, oxygen is continuously released into the plasma and the surrounding tissue, resulting in longitudinally varying oxygen levels in the blood vessels. In the present study, the authors investigated whether a tumor oxygenation model that incorporated longitudinally varying oxygen levels would provide different predictions of necrotic fractions and radiosensitivity compared to commonly used models with a constant oxygen pressure.Methods:: Our models simulated oxygen diffusion based on a Greenˈs function approach and oxygen consumption according to the Michaelis‐Menten equation. The authors constructed tumor models with different vascular fractions (VFs), from which they generated depth oxygenation curves and a look‐up table of oxygen pressure gradients. The authors evaluated models of spherical tumors of various sizes, from 1 to 104 mg. The authors compared the results from a model with constant vessel oxygen (CVO) pressure to those from models with longitudinal variations in oxygen saturation and either a constant VF (CVF) or variable VF (VVF) within the tumor tissue. The authors monitored the necrotic fractions, defined as tumor regions with an oxygen pressure below 1 mmHg. Tumor radiation sensitivity was expressed as D99, the homogeneous radiation dose required for a tumor control probability of 0.99.Results:: In the CVO saturation model, no necrosis was observed, and decreasing the VF could only decrease the D99 by up to 10%. Furthermore, the D99 vs VF dependence was similar for different tumor masses. Compared to the CVO model, the extended CVF and VVF models provided clearly different results, including pronounced effects of VF and tumor size on the necrotic fraction and D99, necrotic fractions ranging from 0% to 97%, and a maximal D99 increment of 57%. Only minor differences were observed between different vessel architectures, i.e., CVF vs VVF. In the smallest tumor with a low necrotic fraction, the D99 strictly decreased with increasing blood velocity. Increasing blood velocity also decreased the necrotic fraction in all tumor sizes. VF had the most profound influence on both the necrotic fraction and on D99.Conclusions:: Our present analysis of necrotic formation and the impact of tumor oxygenation on D99 demonstrated the importance of including longitudinal variations in vessel oxygen content in tumor models. For small tumors, radiosensitivity was particularly dependent on VF and slightly dependent on the blood velocity and vessel arrangement. These dependences decreased with increasing tumor size, because the necrotic fraction also increased, thereby decreasing the number of viable tumor cells that required sterilization. The authors anticipate that the present model will be useful for estimating tumor oxygenation and radiation response in future detailed studies.


  • Intracranial Volume Before and After Surgical Treatment for Isolated Metopic Synostosis

    by Giovanni Maltese, Peter Tarnow, Emma Wikberg, Peter Bernhardt, Jakob Heydorn Lagerlöf, Robert Tovetjärn, Lars Kölby

    Metopic synostosis results in a keel-shaped forehead, hypotelorism, and an increased interparietal width. This study aimed to measure the frontal and total intracranial volume in patients with metopic synostosis before and after surgery and to compare the effect of 2 different operation methods. All patients operated for isolated metopic synostosis between 2002 and 2008 at Sahlgrenska University Hospital who had undergone preoperative and/or postoperative computed tomographic examination (at 3 y of age) were included. The patients were grouped according to operation method: (1) forehead remodeling in combination with a bone graft or (2) forehead remodeling in combination with a spring. Sex- and age-matched controls were identified. A previously developed MATLAB computer program was used to measure the frontal and total intracranial volumes. Sixty patients and 198 controls were included. Preoperatively, the patients with metopic synostosis had significantly lower frontal volumes than those of the controls (P < 0.001) but equal total intracranial volumes. The operations redistributed the intracranial volume and resulted in an improved, frontal-total intracranial volume ratio. However, at 3 years of age, the frontal volume (P < 0.001), total intracranial volume (P ≤ 0.002), and ratio between the 2 (P < 0.001) were significantly lower in the patients than in the controls. The 2 operation methods were equally efficient in creating an improved frontal-total ratio. Surgery for metopic synostosis improves the distribution of the intracranial volume but does not result in normal total intracranial volume or frontal volume at 3 years of age.


  • New objective measurement of forehead symmetry in unicoronal craniosynostosis – comparison between fronto-orbital advancement and forehead remodelling with a bone graft

    by Giovanni Maltese, Peter Tarnow, Annelie Lindström, Jakob Heydorn Lagerlöf, Peter Bernhardt, Robert Tovetjärn, Lars Kölby

    Patients with unicoronal synostosis (UCS) present with ipsilateral forehead flattening, contralateral frontal bossing, and rotation of the facial midline. Uni- or bilateral fronto-orbital advancement (FOA) techniques are the most common surgical approaches for correction of UCS. The purpose of this study was to objectively evaluate the surgical outcome in patients for UCS, using a new MATLAB computer tool programmed to measure the symmetry of the two halves of the forehead.Files were reviewed from a consecutive series of patients treated for UCS at the unit, from 1979–2008. The patients were grouped according to the method of operation used. The computer tool evaluated preoperative and postoperative cephalograms and CT scans. Eighty-eight patients were included. The male-to-female ratio was 1:2.4. Forty-six patients had been operated on with FOA and 42 with forehead remodelling using a calvarial bone graft. Forehead symmetry was significantly improved by both techniques (p < 0.001 for both), but the postoperative forehead symmetry was significantly better after forehead remodelling (p = 0.025). The reoperation rate was much lower for the second group (6.5 vs 37.2%, p < 0.001). It is concluded that forehead remodelling with a calvarial bone graft creates a more symmetrical forehead than FOA and may, therefore, be a better alternative for treatment of unicoronal synostosis.


  • Image-based 3D modeling study of the influence of vessel density and blood hemoglobin concentration on tumor oxygenation and response to irradiation

    by Jakob H. Lagerlöf, Jon Kindblom, Eliane Cortez, Kristian Pietras, Peter Bernhardt


  • A Novel Quantitative Image-Based Method for Evaluating Cranial Symmetry and Its Usefulness in Patients Undergoing Surgery for Unicoronal Synostosis

    by Peter Bernhardt, Annelie Lindström, Giovanni Maltese, Peter Tarnow, Jacob Heydorn Lagerlöf, Lars Kölby

    Background Unicoronal synostosis presents with cranial asymmetry. Fixed points are difficult to identify; surgical results are therefore difficult to evaluate. The aim of this study was to develop a computer-based method for evaluation of forehead symmetry to enable evaluation of surgical results in unicoronal synostosis. Methods The MATLAB tool was programmed to segment computed tomographic images, leaving the outermost contour. Cephalometric images were segmented manually due to lower contrast. A center-point (O) and an end-point were manually defined in the midline of the forehead and at the nonfused coronal suture, respectively. The program then found a point (p) on the fused side, at the same distance from the O as the end-point. The contours of the left and right side of the forehead were thereafter superimposed, and the position of minimal area mismatch of the sides was identified. To correct for growth between preoperative images and follow-up, the number of mismatching pixels was related to the area outlined by the contour of the forehead, the end-point and p. Two quantities, the relative symmetry change and the absolute symmetry change, were defined and evaluated by repeated measurements on spherical and elliptical phantoms and 15 patients. Results Measurements with the MATLAB program were reliable with an SD of 0.26% to 5.39% for the expected range of differences. The SD was lower for measurements on computed tomographic images than for measurements on cephalometric images. The SD was also lower in patients with large surgical improvement than in patients with little improvement. The results support the use of relative symmetry change to evaluate surgical results. Conclusions Our new computer-based method is capable of measuring forehead symmetry with good precision. This method can be used for systematic evaluation of surgical outcome for unicoronal synostosis and other asymmetric skull deformities.


  • A new computer tool for systematic evaluation of intracranial volume and its capacity to evaluate the result of the operation for metopic synostosis

    by Emma Wikberg, Peter Bernhardt, Giovanni Maltese, Peter Tarnow, Jakob Heydorn Lagerlöf, Lars Kölby

    The aim of this project was to develop a tool for systematic evaluation of volumetric changes after surgery for craniosynostosis. A computer program using MATLAB was developed to measure total intracranial volume and frontal volume, anterior to the coronary sutures, by multiplying the area with slice thickness of each slice from just above foramen magnum to just beneath the vertex in CT examinations. The ratio between frontal volume and total volume was used for evaluation of the clinical result in 12 patients operated on for metopic synostosis. In 0.625 and 5 millimetre slices the coefficients of variation were 0.00049 and 0.00058, respectively, for measurements of total volume. The highest coefficient of variation was found in postoperative measurements of the frontal volume and was 0.014 in 0.625 millimetre slices. Measurements in 5 millimetre slices resulted in 3.8% ± 1.5% (mean ± SD) lower total volumes and 5.8% ± 5.3% lower frontal volumes than measurements in 0.625 millimetre slices. In patients operated on for metopic synostosis the ratio between frontal volume and total volume increased 25% ± 16% for patients operated on with cranioplasty in combination with a spring (n = 6) and 20% ± 13% for patients operated on with cranioplasty in combination with a bone transplant (n = 6). In summary, this study has developed a tool that can determine frontal and total intracranial volume with little variation. This tool can be used for systematic evaluation of the result of the operation for metopic synostosis.