Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiao Ma has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ultra-Wideband Impedance Spectroscopy of the Nucleus in a Live Cell

    by Xiaotian Du, Caroline Ferguson, Xiao Ma, Xuanhong Cheng, James C. M. Hwang

    This paper describes the first application of a double-shell model in ultra-wideband impedance spectroscopy of a live cell. The impedance spectrum measured from 9 kHz to 9 GHz is analyzed by using the double-shell cell model to separate the contribution of the nucleus from that of the cytoplasm. The model parameters include the nucleus-to-cell radius ratio (r) and a parallel R-C circuit for each of the four cell compartments: the cell membrane (CM), the cytoplasm (CP), the nuclear membrane (NM), and the nucleoplasm (NP). In general, the extracted radius ratio agrees with that measured by optical microscopy, and the extracted resistances and capacitances agree with the literature and order-of-magnitude estimates. For example, for a human lymphocytes cell with r ≈ 0.8, the nuclear contribution is approximately linear. Therefore, the membrane parameters are constant so that RCM = 1.5 MΩ, CCM = 1.5 pF, RNM = 0.05 MΩ, and CNM = 1.2 pF, but the plasma parameters are linearly scaled so that RCP → 0.5(1 − r) MΩ, CCP → 6.7/(1 − r) fF, RNP → 0.12r MΩ, and CNP → 9.4/r fF. Because morphological and structural changes of a cell nucleus are important screening, diagnostic, and prognostic markers, these results suggest that ultra-wideband impedance spectroscopy may be a fast, compact, and label-free technique in cancer cytology.


  • Open Access

    Broadband Electrical Sensing of a Live Biological Cell with In Situ Single-Connection Calibration

    by Xiao Ma, Xiaotian Du, Lei Li, Caroline Ladegard, Xuanhong Cheng, James C. M. Hwang

    Single-connection in situ calibration using biocompatible solutions is demonstrated in single-cell sensing from 0.5 to 9 GHz. The sensing is based on quickly trapping and releasing a live cell by dielectrophoresis on a coplanar transmission line with a little protrusion in one of its ground electrodes. The same transmission line is used as the calibration standard when covered by various solutions of known permittivities. The results show that the calibration technique may be precise enough to differentiate cells of different nucleus sizes, despite the measured difference being less than 0.01 dB in the deembedded scattering parameters. With better accuracy and throughput, the calibration technique may allow broadband electrical sensing of live cells in a high-throughput cytometer.


  • Sensitivity Analysis for Ultra-Wideband 2-Port Impedance Spectroscopy of a Live Cell

    by Xiao Ma, Xiaotian Du, Lei Li, Hang Li, Xuanhong Cheng, James C. M. Hwang

    For ultra-wideband (9 kHz-9 GHz) 2-port impedance spectroscopy of a biological cell, sensitivity analysis was carried out for extracting lumped cell characteristics such as membrane resistance (as large as 1 MΩ) and cytoplasm capacitance (as small as 10 fF) from the scattering parameters. The scattering parameters were measured on a coplanar waveguide with a Jurkat cell trapped by dielectrophoresis either in a series or shunt configuration. The sensitivity analysis validated our previous empirical observation that the insertion loss of a series-trapped cell and the return loss of a shunt-trapped cell were most sensitive to the cell impedance. Additionally, the membrane resistance and cytoplasm capacitance were most sensitive to lowand high-frequency scattering parameters, respectively. In the future, the analysis can be used to optimize the test setup and protocol for fast, compact, and label-free characterization of a cell at the subcelluar level.


  • Validation of Clausius–Mossotti Function in Wideband Single-Cell Dielectrophoresis

    by Xiaotian Du, Xiao Ma, Hang Li, Lei Li, Xuanhong Cheng, James C. M. Hwang

    For the first time, both lower and upper crossover frequencies of the real part of the Clausius-Mossotti function were calculated by using cell parameters measured on the same ultra-wideband setup as that for single-cell dielectrophoresis. The calculation suggests that the lower crossover frequency can be from 0 to 127 kHz and the upper crossover frequency can be from 45 to 108 MHz, in the unlikely case when uncertainties in the cell parameters all add up. The calculated lower crossover frequency was found to be in general agreement with the measured values of 28 ± 4 kHz. However, the calculated upper crossover frequency was significantly different from the measured values of 326 ± 35 MHz The difference can be attributed to the field being highly nonuniform in single-cell dielectrophoresis, especially at higher frequencies. Additionally, with closely spaced electrodes in singlecell dielectrophoresis, adhesive force may have to be considered even for a relatively nonadherent Jurkat cell. In any case, the difference between the calculated and measured crossover frequency suggests that the classical Clausius-Mossotti function, originally derived from the Maxwell-Wagner mixture model of a cell suspension, may not apply to single-cell dielectrophoresis in a straightforward manner, especially at high frequencies.


  • Correlation Between Optical Fluorescence and Microwave Transmission During Single-Cell Electroporation

    by Hang Li, Xiao Ma, Xiaotian Du, Lei Li, Xuanhong Cheng, James C. M. Hwang

    Objective: Multimodal characterization of a mammalian cell by optical and microwave techniques simultaneously during electroporation. Methods: Using a coplanar waveguide with a Jurkat cell trapped in the middle of its center conductor, continuous waves at 100 kHz of different amplitudes were applied for 20 s while microwave transmission coefficients at 9 GHz were measured every 0.4 s. Results: The onset of electroporation was indicated by abrupt changes in both fluorescence intensity and transmission coefficient. Additionally, in measurements that lasted 300 s, the transmission coefficient was found to recover to the pre-poration level, while the fluorescence intensity remained different. Since the cells were confirmed viable through post-poration staining, the recovery of the transmission coefficient suggested reversible electroporation. Conclusion: These experimental results show that the transmission coefficient could serve as a label-free indicator of cell membrane permeability during and after electroporation. Furthermore, it can be used to expeditiously differentiate reversible electroporation from the irreversible one. Significance: This study should aid fundamental analysis of cell physiology, as well as molecular delivery in cell engineering and electrotherapy.


  • Ultra-Wideband Impedance Spectroscopy of a Live Biological Cell

    by Xiao Ma, Xiaotian Du, Hang Li, Xuanhong Cheng, James C. M. Hwang

    For the first time, the impedance spectrum of a live Jurkat T-lymphocytes human cell was characterized in a single sweep, spanning six decades of frequency from 9 kHz to 9 GHz. The ultra-wide bandwidth bridged the traditional impedance spectroscopy at kilohertz-megahertz frequencies with the recently developed microwave dielectric spectroscopy, which can probe the cell interior without being hindered by the cell membrane. Based on the measured scattering parameters and a simple cell model, an equivalent circuit of four nondispersive elements, including membrane resistance, membrane capacitance, cytoplasm resistance, and cytoplasm capacitance, was extracted and found sufficient to explain the so-called β relaxation over the frequencies measured. These extracted cell parameters are in general agreement with the literature but are believed to be more accurate, giving the relatively small standard deviations, the configuration with a cell in intimate contact with the measurement electrodes, and the ultra-wide bandwidth of the measurement.


  • A Multistate Single-Connection Calibration for Microwave Microfluidics

    by Xiao Ma, Nathan D. Orloff, Charles A. E. Little, Christian J. Long, Isaac E. Hanemann, Song Liu, Jordi Mateu, James C. Booth, James C. M. Hwang

    With emerging medical, chemical, and biological applications of microwave-microfluidic devices, many researchers desire a fast and accurate calibration that can be achieved in a single connection. However, traditional on-wafer or coaxial calibrations require measurements of several different artifacts to the data prior to measuring the microwave-microfluidic device. Ideally, a single artifact would be able to present different impedance states to correct the vector network analyzer data, minimizing drift and eliminating artifact-to-artifact connection errors. Here, we developed a multistate single-connection calibration that used a coplanar waveguide loaded with a microfluidic channel. We then used measurements of the uncorrected scattering parameters of the coplanar waveguide with the channel empty, filled with deionized water, and filled with 30 w% (30 grams per liter) of saline to construct an eight-term error model and switch-term correction. After correction, the residuals between measured scattering parameters and with the literature-based finite-element simulations were below -40 dB from 100 MHz to 110 GHz. This multistate single-connection calibration is compatible with both wafer-probed and connectorized microwave-microfluidic devices for accurate impedance spectroscopy and materials characterization without the need for multiple device measurements.