Walter Katsumi Sakamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Walter Katsumi Sakamoto has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- José Antonio Malmonge
Universidade Estadual Paulista, Brasil
10 shared publications - Aparecido Augusto de Carvalho
Universidade Estadual Paulista, Brazil
6 shared publications - Luiz Francisco Malmonge
Universidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteira, Ilha Solteira, Brazil
6 shared publications D. H. F. Kanda
University of São Paulo State—UNESP
4 shared publicationsD. K. Das-Gupta
University of Wales–-Bangor
3 shared publicationsD.K. Das-Gupta
3 shared publications
Latest Publications
- 14 July 2017
- Published by Springer Nature
- p. 195-215
Piezoelectric Composites: Fabrication, Characterization, and Its Application as Sensor
- 14 July 2017
- Published by Springer Nature
- p. 195-215
Piezoelectric Composites: Fabrication, Characterization, and Its Application as Sensor
- 16 August 2016
- Published by Springer Nature in Polymer Bulletin
- Vol. 74 (5) , 1483-1492
PVDF-PAni blend: a free-standing film with variable electrical resistance
- 16 August 2016
- Published by Springer Nature in Polymer Bulletin
- Vol. 74 (5) , 1483-1492
PVDF-PAni blend: a free-standing film with variable electrical resistance
- 25 May 2016
- Published by Springer Nature
- p. 1-7
Development and Characterization of an ITO Nanocomposite Film Sensor for Damage Detection
- 25 May 2016
- Published by Springer Nature
- p. 1-7
Development and Characterization of an ITO Nanocomposite Film Sensor for Damage Detection
- 10 April 2015
- Published by Springer Nature in Polymer Bulletin
- Vol. 72 (7) , 1787-1797
Electrical and mechanical characterization of a flexible conducting composite
- 10 April 2015
- Published by Springer Nature in Polymer Bulletin
- Vol. 72 (7) , 1787-1797
Electrical and mechanical characterization of a flexible conducting composite
- 1 December 2014
- Published by Elsevier in Polymer Testing
- Vol. 40, 99-105
Influence of cellulose nanofibrils on soft and hard segments of polyurethane/cellulose nanocomposites and effect of humidity on their mechanical properties
- 1 December 2014
- Published by Elsevier in Polymer Testing
- Vol. 40, 99-105
Influence of cellulose nanofibrils on soft and hard segments of polyurethane/cellulose nanocomposites and effect of humidity on their mechanical properties
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10994734,p. 295-297
Polymer matrix-based piezoelectric composite for structural health monitoring
Structural health monitoring (SHM) refers to the procedure of assessing the structure conditions continuously so it is an alternative to conventional nondestructive evaluation (NDE) techniques [1]. With the growing developments in sensor technology acoustic emission (AE) technology has been attracting attention in SHM applications. AE are characterized by waves produced by the sudden internal stress redistribution caused by the changes in the internal structure, such as fatigue, crack growth, corrosion, etc. Piezoelectric materials such as Lead Zirconate Titanate (PZT) ceramic have been widely used as sensor due to its high electromechanical coupling factor and piezoelectric d coefficients. Because of the poor mechanical characteristic and the lack in the formability of the ceramic, polymer matrix-based piezoelectric composites have been studied in the last decade in order to obtain better properties in comparison with a single phase material. In this study a composite film made of polyurethane (PU) and PZT ceramic particles partially recovered with polyaniline (PAni) was characterized and used as sensor for AE detection. Preliminary results indicate that the presence of a semiconductor polymer (PAni) recovering the ceramic particles, make the poling process easier and less time consuming. Also, it is possible to observe that there is a great potential to use such type of composite as sensor for structure health monitoring.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10994734,p. 295-297
Polymer matrix-based piezoelectric composite for structural health monitoring
Structural health monitoring (SHM) refers to the procedure of assessing the structure conditions continuously so it is an alternative to conventional nondestructive evaluation (NDE) techniques [1]. With the growing developments in sensor technology acoustic emission (AE) technology has been attracting attention in SHM applications. AE are characterized by waves produced by the sudden internal stress redistribution caused by the changes in the internal structure, such as fatigue, crack growth, corrosion, etc. Piezoelectric materials such as Lead Zirconate Titanate (PZT) ceramic have been widely used as sensor due to its high electromechanical coupling factor and piezoelectric d coefficients. Because of the poor mechanical characteristic and the lack in the formability of the ceramic, polymer matrix-based piezoelectric composites have been studied in the last decade in order to obtain better properties in comparison with a single phase material. In this study a composite film made of polyurethane (PU) and PZT ceramic particles partially recovered with polyaniline (PAni) was characterized and used as sensor for AE detection. Preliminary results indicate that the presence of a semiconductor polymer (PAni) recovering the ceramic particles, make the poling process easier and less time consuming. Also, it is possible to observe that there is a great potential to use such type of composite as sensor for structure health monitoring.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 350-351
Measurement of radiant energy using pyroelectric polymer/ceramic composite
Monitoring non-ionizing radiant energy is increasingly demanded for many applications such as automobile, biomedical and security system. Thermal type infrared (IR) sensors can operate at room temperature and pyroelectric materials have high sensitivity and accuracy for that application. Working as thermal transducer pyroelectric sensor converts the non-quantified thermal flux into the output measurable quantity of electrical charge, voltage or current. In the present study the composite made of poly(vinylidene fluoride) - PVDF and lead zirconate titanate (PZT) partially recovered with polyaniline (PAni) conductor polymer has been used as sensor element. The pyroelectric coefficient p(T) was obtained by measuring the pyroelectric reversible current, i.e., measuring the thermally stimulated depolarization current (TSDC) after removing all irreversible contribution to the current such as injected charge during polarization of the sample. To analyze the sensing property of the pyroelectric material, the sensor is irradiated by a high power light source (halogen lamp of 250 W) that is chopped providing a modulated radiation. A device assembled in the laboratory is used to change the light intensity sensor, an aluminum strip having openings with diameters ranging from 1 to 10 mm incremented by one millimeter. The sensor element is assembled between two electrodes while its frontal surface is painted black ink to maximize the light absorption. The signal from the sensor is measured by a Lock-In amplifier model SR530 - Stanford Research Systems. The behavior of the output voltage for an input power at several frequencies for PZT-PAni/PVDF (30/70 vol%) composite follows the inverse power law (1/f) and the linearity can be observed in the frequency range used.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 350-351
Measurement of radiant energy using pyroelectric polymer/ceramic composite
Monitoring non-ionizing radiant energy is increasingly demanded for many applications such as automobile, biomedical and security system. Thermal type infrared (IR) sensors can operate at room temperature and pyroelectric materials have high sensitivity and accuracy for that application. Working as thermal transducer pyroelectric sensor converts the non-quantified thermal flux into the output measurable quantity of electrical charge, voltage or current. In the present study the composite made of poly(vinylidene fluoride) - PVDF and lead zirconate titanate (PZT) partially recovered with polyaniline (PAni) conductor polymer has been used as sensor element. The pyroelectric coefficient p(T) was obtained by measuring the pyroelectric reversible current, i.e., measuring the thermally stimulated depolarization current (TSDC) after removing all irreversible contribution to the current such as injected charge during polarization of the sample. To analyze the sensing property of the pyroelectric material, the sensor is irradiated by a high power light source (halogen lamp of 250 W) that is chopped providing a modulated radiation. A device assembled in the laboratory is used to change the light intensity sensor, an aluminum strip having openings with diameters ranging from 1 to 10 mm incremented by one millimeter. The sensor element is assembled between two electrodes while its frontal surface is painted black ink to maximize the light absorption. The signal from the sensor is measured by a Lock-In amplifier model SR530 - Stanford Research Systems. The behavior of the output voltage for an input power at several frequencies for PZT-PAni/PVDF (30/70 vol%) composite follows the inverse power law (1/f) and the linearity can be observed in the frequency range used.
- 9 January 2013
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 22 (2)
Effect of controlled conductivity on thermal sensing property of 0–3 pyroelectric composite
- 9 January 2013
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 22 (2)
Effect of controlled conductivity on thermal sensing property of 0–3 pyroelectric composite
- Open Access
- 15 March 2012
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 15 (2) , 198-203
Pyroelectric composite film for X-ray intensity detection
Composite material obtained with modified lead titanate (Pz34) ferroelectric ceramic and polyether-ether-ketone (PEEK) polymer matrix was used as sensitive component to measure X-ray intensity in a novel detection system. The sensing element works as a thermal transducer, converting a non-quantified thermal flux into an output measurable quantity of electrical voltage. The samples were obtained up to 60 vol.% of ceramic, by hot pressing the mixture of Pz34 and PEEK powders at 368 °C and applying 12 MPa pressure for 2.0 hours. The sensor response varies from 2.70 to 0.80 V in the energy fluence rate range of 6.30 to 37.20 W.m-2. The absorbed incident energy was analyzed as a function of the ionizing energy. Furthermore, by measuring the pyroelectric activity of the composite film it was observed that there is no degradation of the sensor after the irradiation
- 15 March 2012
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 15 (2) , 198-203
Open AccessPyroelectric composite film for X-ray intensity detection
Composite material obtained with modified lead titanate (Pz34) ferroelectric ceramic and polyether-ether-ketone (PEEK) polymer matrix was used as sensitive component to measure X-ray intensity in a novel detection system. The sensing element works as a thermal transducer, converting a non-quantified thermal flux into an output measurable quantity of electrical voltage. The samples were obtained up to 60 vol.% of ceramic, by hot pressing the mixture of Pz34 and PEEK powders at 368 °C and applying 12 MPa pressure for 2.0 hours. The sensor response varies from 2.70 to 0.80 V in the energy fluence rate range of 6.30 to 37.20 W.m-2. The absorbed incident energy was analyzed as a function of the ionizing energy. Furthermore, by measuring the pyroelectric activity of the composite film it was observed that there is no degradation of the sensor after the irradiation
- 1 February 2011
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 82 (2) , 023903
Photopyroelectric response of PTCa/PEEK composite
A pyroelectric composite made of calcium modified lead titanate ceramic and polyether–ether–ketone high performance polymer was obtained in the film form by hot pressing the ceramic/polymer mixture into the desired composition. After polarization with a suitable electric field, a ceramic composite film (60% vol.) exhibited a pyroelectric figure of merit three times higher than that of a lead zirconate titanate ceramic. The material was used as infrared radiation sensor. The voltage responsivity decreases with the inverse of the frequency showing the same behavior of the thermally thick sensor. The reproducibility of the sensor responses was observed.
- 1 February 2011
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 82 (2) , 023903
Photopyroelectric response of PTCa/PEEK composite
A pyroelectric composite made of calcium modified lead titanate ceramic and polyether–ether–ketone high performance polymer was obtained in the film form by hot pressing the ceramic/polymer mixture into the desired composition. After polarization with a suitable electric field, a ceramic composite film (60% vol.) exhibited a pyroelectric figure of merit three times higher than that of a lead zirconate titanate ceramic. The material was used as infrared radiation sensor. The voltage responsivity decreases with the inverse of the frequency showing the same behavior of the thermally thick sensor. The reproducibility of the sensor responses was observed.