Temesghen Tekeste
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Temesghen Tekeste has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Baker Mohammad
Khalifa University, Abu Dhabi, United Arab Emirates
8 shared publications Hani Saleh
Khalifa University of Science and Technology
4 shared publications- Hani Saleh
Khalifa University
4 shared publications Mohammed Ismail
Wayne State University
4 shared publications- Mohammed Ismail
Wayne State University
4 shared publications - Ahsan Habib Khandoker
Department of Biomedical Engineering and Biotechnology Khalifa University Abu Dhabi United Arab Emirates
2 shared publications
Latest Publications
- 12 March 2019
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 99 (2) , 413-426
A novel algorithm for the prediction and detection of ventricular arrhythmia
- 12 March 2019
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 99 (2) , 413-426
A novel algorithm for the prediction and detection of ventricular arrhythmia
- 18 February 2019
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 99 (2) , 325-338
A novel SIFT architecture and ASIC implementation for real time SOC application
- 18 February 2019
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 99 (2) , 325-338
A novel SIFT architecture and ASIC implementation for real time SOC application
- 26 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 66 (2) , 669-679
Ultra-Low Power QRS Detection and ECG Compression Architecture for IoT Healthcare Devices
An ultra-low power electrocardiogram (ECG) processing architecture with an adequate level of accuracy is a necessity for Internet of Things (IoT) medical wearable devices. This paper presents a novel real-time QRS detector and an ECG compression architecture for IoT healthcare devices. An absolute-value curve length transform (A-CLT) is proposed that effectively enhances the QRS complex detection with minimized hardware resources. The proposed architecture requires adders, shifters, and comparators only, and removes the need for any multipliers. QRS detection was accomplished by using adaptive thresholds in the A-CLT transformed ECG signal, and achieved a sensitivity of 99.37% and the predictivity of 99.38% when validated using Physionet ECG database. Furthermore, a lossless compression technique was incorporated into the proposed architecture that uses the ECG signal first derivative and entropy encoding. An average compression ratio of 2.05 was achieved when evaluated using MIT-BIH database. The proposed QRS detection architecture deals with almost all the ECG signal artifacts, such as low-frequency noise, baseline drift, and high-frequency interference with minimum hardware resources. The proposed QRS architecture was synthesized using 65-nm low-power process using standard-cell-based flow. The power consumption of the design was 6.5 nW while operating at a supply of 1 V and a frequency of 250 Hz. Moreover, the system could benefit from duty-cycling.
- 26 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 66 (2) , 669-679
Ultra-Low Power QRS Detection and ECG Compression Architecture for IoT Healthcare Devices
An ultra-low power electrocardiogram (ECG) processing architecture with an adequate level of accuracy is a necessity for Internet of Things (IoT) medical wearable devices. This paper presents a novel real-time QRS detector and an ECG compression architecture for IoT healthcare devices. An absolute-value curve length transform (A-CLT) is proposed that effectively enhances the QRS complex detection with minimized hardware resources. The proposed architecture requires adders, shifters, and comparators only, and removes the need for any multipliers. QRS detection was accomplished by using adaptive thresholds in the A-CLT transformed ECG signal, and achieved a sensitivity of 99.37% and the predictivity of 99.38% when validated using Physionet ECG database. Furthermore, a lossless compression technique was incorporated into the proposed architecture that uses the ECG signal first derivative and entropy encoding. An average compression ratio of 2.05 was achieved when evaluated using MIT-BIH database. The proposed QRS detection architecture deals with almost all the ECG signal artifacts, such as low-frequency noise, baseline drift, and high-frequency interference with minimum hardware resources. The proposed QRS architecture was synthesized using 65-nm low-power process using standard-cell-based flow. The power consumption of the design was 6.5 nW while operating at a supply of 1 V and a frequency of 250 Hz. Moreover, the system could benefit from duty-cycling.
- 4 September 2018
- Published by Springer Nature
- p. 141-152
Ultra-Low-Power ECG Processor for IoT SOCs
- 12 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (4) , 739-750
A Nanowatt Real-Time Cardiac Autonomic Neuropathy Detector
This paper presents an electrocardiogram (ECG) processor on chip for full ECG feature extraction and cardiac autonomic neuropathy (CAN) classification. Full ECG extraction is performed using absolute value curve length transform (A-CLT) for QRS peak detection and using low-pass differentiation for other ECG features such as QRS on , QRS off , P wave , and T wave . The proposed QRS detector attained a sensitivity of 99.37% and predictivity of 99.38%. The extracted QRS peak to QRS peak intervals (RR intervals) along with QT intervals enable CAN severity detection, which is a cardiac arrhythmia usually seen in diabetic patients leading to increased risk of sudden cardiac death. This paper presents the first hardware real-time implementation of CAN severity detector that is based on RR variability and QT variability analysis. RR variability metrics are based on mean RR interval and root mean square of standard differences of the RR intervals. The proposed architecture was implemented in 65-nm technology and consumed 75 nW only at 0.6 V, when operating at 250 Hz. Ultralow power dissipation of the system enables it to be integrated into wearable healthcare devices.
- 12 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (4) , 739-750
A Nanowatt Real-Time Cardiac Autonomic Neuropathy Detector
This paper presents an electrocardiogram (ECG) processor on chip for full ECG feature extraction and cardiac autonomic neuropathy (CAN) classification. Full ECG extraction is performed using absolute value curve length transform (A-CLT) for QRS peak detection and using low-pass differentiation for other ECG features such as QRS on , QRS off , P wave , and T wave . The proposed QRS detector attained a sensitivity of 99.37% and predictivity of 99.38%. The extracted QRS peak to QRS peak intervals (RR intervals) along with QT intervals enable CAN severity detection, which is a cardiac arrhythmia usually seen in diabetic patients leading to increased risk of sudden cardiac death. This paper presents the first hardware real-time implementation of CAN severity detector that is based on RR variability and QT variability analysis. RR variability metrics are based on mean RR interval and root mean square of standard differences of the RR intervals. The proposed architecture was implemented in 65-nm technology and consumed 75 nW only at 0.6 V, when operating at 250 Hz. Ultralow power dissipation of the system enables it to be integrated into wearable healthcare devices.
- 12 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 64 (9) , 2624-2637
Ultra-Low Power, Secure IoT Platform for Predicting Cardiovascular Diseases
Internet of Things (IoT) promises to revolutionize the health-care sector through remote, continuous, and non-invasive monitoring of patients. However, there are two main challenges faced by the IoT-enabled medical devices: energy-efficiency and security/privacy concerns. Researchers have independently attempted to develop solutions, such as low-power ECG-processors and security protocols, that address these challenges on an individual basis. However, it is imperative to investigate holistic solutions that integrate in a synergistic manner, delivering an overall secure and energy-efficient product. In this paper, we develop an ultra-low power and secure IoT sensing/pre-processing platform for prediction of ventricular arrhythmia using ECG signals. Our proposed solution is able to predict the on-set of the critical cardiovascular events upto 3 h in advance with 86% accuracy. Moreover, the proposed architecture is designed using an Application Specific Integrated Circuits design flow in 65-nm Low Power Enhanced technology; the power it consumes is 62.2% less than that of the state-of-the-art approaches, while occupying 16.0% smaller area. The proposed processor makes use of ECG signals to extract a chip-specific ECG key that enables protection of communication channel. By integrating the ECG key with an existing design-for-trust solution, the proposed platform offers protection also at the hardware level, thwarting hardware security threats, such as reverse engineering and counterfeiting. Through efficient sharing of on-chip resources, the overhead of the multi-layered security infrastructure is kept at 9.5% for area and 0.7% for power with no impact on the speed of the design.
- 12 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 64 (9) , 2624-2637
Ultra-Low Power, Secure IoT Platform for Predicting Cardiovascular Diseases
Internet of Things (IoT) promises to revolutionize the health-care sector through remote, continuous, and non-invasive monitoring of patients. However, there are two main challenges faced by the IoT-enabled medical devices: energy-efficiency and security/privacy concerns. Researchers have independently attempted to develop solutions, such as low-power ECG-processors and security protocols, that address these challenges on an individual basis. However, it is imperative to investigate holistic solutions that integrate in a synergistic manner, delivering an overall secure and energy-efficient product. In this paper, we develop an ultra-low power and secure IoT sensing/pre-processing platform for prediction of ventricular arrhythmia using ECG signals. Our proposed solution is able to predict the on-set of the critical cardiovascular events upto 3 h in advance with 86% accuracy. Moreover, the proposed architecture is designed using an Application Specific Integrated Circuits design flow in 65-nm Low Power Enhanced technology; the power it consumes is 62.2% less than that of the state-of-the-art approaches, while occupying 16.0% smaller area. The proposed processor makes use of ECG signals to extract a chip-specific ECG key that enables protection of communication channel. By integrating the ECG key with an existing design-for-trust solution, the proposed platform offers protection also at the hardware level, thwarting hardware security threats, such as reverse engineering and counterfeiting. Through efficient sharing of on-chip resources, the overhead of the multi-layered security infrastructure is kept at 9.5% for area and 0.7% for power with no impact on the speed of the design.
- 6 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Fused floating point arithmetic for discrete wavelet transform
Floating point arithmetic provides high resolution and wide range for representing numbers. However it requires huge resources and high power consumption which makes it unfavorable for implementation in power constrained wearable devices. In this paper we present fused floating point arithmetic for realizing Discrete Wavelet Transform (DWT). Comparative analysis is performed to determine the advantages of fused floating point. Implementing DWT using fused floating point dot product required 22% less area than using conventional floating point arithmetic. Moreover the required power consumption is 67% less. DWT is chosen in the analysis since it is widely used in wearable ECG processors due to its inherent behavior to suppress noise.
- 6 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Fused floating point arithmetic for discrete wavelet transform
Floating point arithmetic provides high resolution and wide range for representing numbers. However it requires huge resources and high power consumption which makes it unfavorable for implementation in power constrained wearable devices. In this paper we present fused floating point arithmetic for realizing Discrete Wavelet Transform (DWT). Comparative analysis is performed to determine the advantages of fused floating point. Implementing DWT using fused floating point dot product required 22% less area than using conventional floating point arithmetic. Moreover the required power consumption is 67% less. DWT is chosen in the analysis since it is widely used in wearable ECG processors due to its inherent behavior to suppress noise.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 998-1001
Adaptive ECG interval extraction
ECG intervals such as QRS, QT and PR provide significant information and are widely used as clinical parameters for diagnosing cardiac diseases. This paper presents a novel QRS detection technique based on Curve Length Transform (CLT) and a refined delineation of P-wave and T-wave using Discrete Wavelet Transform (DWT). The proposed technique was verified using the PhysioNet database. The QRS detection achieved a sensitivity of 98.59% and a positive predictivity of 97.86%. The QRS duration, QT interval and PR interval had a mean error of -1.56± 28.8ms, -5.39± 42.4ms and 0.86± 40.3ms respectively. The proposed algorithm is computationally efficient and is simpler to implement in hardware, hence, will lead to a faster execution time, smaller design area and consequently low power consumption.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 998-1001
Adaptive ECG interval extraction
ECG intervals such as QRS, QT and PR provide significant information and are widely used as clinical parameters for diagnosing cardiac diseases. This paper presents a novel QRS detection technique based on Curve Length Transform (CLT) and a refined delineation of P-wave and T-wave using Discrete Wavelet Transform (DWT). The proposed technique was verified using the PhysioNet database. The QRS detection achieved a sensitivity of 98.59% and a positive predictivity of 97.86%. The QRS duration, QT interval and PR interval had a mean error of -1.56± 28.8ms, -5.39± 42.4ms and 0.86± 40.3ms respectively. The proposed algorithm is computationally efficient and is simpler to implement in hardware, hence, will lead to a faster execution time, smaller design area and consequently low power consumption.