Alexander Thomas Williams
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexander Thomas Williams has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Pedro Cabrales
University of California San Diego
10 shared publications Cynthia R. Muller
William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, Ohio
4 shared publicationsAndre F. Palmer
William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, Ohio
3 shared publicationsAlfredo Lucas
Department of Bioengineering, University of California San Diego, La Jolla, California
2 shared publicationsAllyn M. Eaker
Department of Bioengineering, University of California San Diego, La Jolla, California
2 shared publications- Andre Francis Palmer
The Ohio State University
2 shared publications
Latest Publications
- Open Access
- 2 May 2023
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 116 (1) , 103987
Prony Analysis of Left Ventricle Pressure and Volume
Direct measurement of cardiac pressure-volume (PV) relationships is the gold standard for assessment of ventricular hemodynamics, but few innovations have been made to "multi-beat" PV analysis beyond traditional signal processing. The Prony method solves the signal recovery problem with a series of dampened exponentials or sinusoids. It achieves this by extracting the amplitude, frequency, dampening, and phase of each component. Since its inception, application of the Prony method to biologic and medical signal has demonstrated a relative degree of success, as a series of dampened complex sinusoids easily generalizes to multifaceted physiological processes. In cardiovascular physiology, the Prony analysis has been used to determine fatal arrythmia from electrocardiogram signals. However, application of the Prony method to simple left ventricular function based on pressure and volume analysis is absent. We have developed a new pipeline for analysis of pressure volume signals recorded from the left ventricle. We propose fitting pressure-volume data from cardiac catheterization to the Prony method for pole extraction and quantification of the transfer function. We implemented the Prony algorithm using open-source Python packages and analyzed the pressure and volume signals before and after severe hemorrhagic shock, and after resuscitation with stored blood. Each animal (n = 6 per group) underwent a 50% hemorrhage to induce hypovolemic shock, which was maintained for 30 min, and resuscitated with 3-week-old stored RBCs until 90% baseline blood pressure was achieved. Pressure-volume catheterization data used for Prony analysis were 1 s in length, sampled at 1000 Hz, and acquired at the time of hypovolemic shock, 15 and 30 min after induction of hypovolemic shock, and 10, 30, and 60 min after volume resuscitation. We next assessed the complex poles from both pressure and volume waveforms. To quantify deviation from the unit circle, which represents deviation from a Fourier series, we counted the number of poles at least 0.2 radial units away from it. We found a significant decrease in the number of poles after shock (p = 0.0072 vs. baseline) and after resuscitation (p = 0.0091 vs. baseline). No differences were observed in this metric pre and post volume resuscitation (p = 0.2956). We next found a composite transfer function using the Prony fits between the pressure and volume waveforms and found differences in both the magnitude and phase Bode plots at baseline, during shock, and after resuscitation. In summary, our implementation of the Prony analysis shows meaningful physiologic differences after shock and resuscitation and allows for future applications to broader physiological and pathophysiological conditions.
- 2 May 2023
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 116 (1) , 103987
Open AccessProny Analysis of Left Ventricle Pressure and Volume
Direct measurement of cardiac pressure-volume (PV) relationships is the gold standard for assessment of ventricular hemodynamics, but few innovations have been made to "multi-beat" PV analysis beyond traditional signal processing. The Prony method solves the signal recovery problem with a series of dampened exponentials or sinusoids. It achieves this by extracting the amplitude, frequency, dampening, and phase of each component. Since its inception, application of the Prony method to biologic and medical signal has demonstrated a relative degree of success, as a series of dampened complex sinusoids easily generalizes to multifaceted physiological processes. In cardiovascular physiology, the Prony analysis has been used to determine fatal arrythmia from electrocardiogram signals. However, application of the Prony method to simple left ventricular function based on pressure and volume analysis is absent. We have developed a new pipeline for analysis of pressure volume signals recorded from the left ventricle. We propose fitting pressure-volume data from cardiac catheterization to the Prony method for pole extraction and quantification of the transfer function. We implemented the Prony algorithm using open-source Python packages and analyzed the pressure and volume signals before and after severe hemorrhagic shock, and after resuscitation with stored blood. Each animal (n = 6 per group) underwent a 50% hemorrhage to induce hypovolemic shock, which was maintained for 30 min, and resuscitated with 3-week-old stored RBCs until 90% baseline blood pressure was achieved. Pressure-volume catheterization data used for Prony analysis were 1 s in length, sampled at 1000 Hz, and acquired at the time of hypovolemic shock, 15 and 30 min after induction of hypovolemic shock, and 10, 30, and 60 min after volume resuscitation. We next assessed the complex poles from both pressure and volume waveforms. To quantify deviation from the unit circle, which represents deviation from a Fourier series, we counted the number of poles at least 0.2 radial units away from it. We found a significant decrease in the number of poles after shock (p = 0.0072 vs. baseline) and after resuscitation (p = 0.0091 vs. baseline). No differences were observed in this metric pre and post volume resuscitation (p = 0.2956). We next found a composite transfer function using the Prony fits between the pressure and volume waveforms and found differences in both the magnitude and phase Bode plots at baseline, during shock, and after resuscitation. In summary, our implementation of the Prony analysis shows meaningful physiologic differences after shock and resuscitation and allows for future applications to broader physiological and pathophysiological conditions.
- 1 February 2022
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 132 (2) , 489-496
Attenuating ischemia-reperfusion injury with polymerized albumin
Polymerized human serum albumin reduced reperfusion injury and preservers microvascular hemodynamics. Polymerized human serum albumin reduces fluid extravasation and prevents fluid extravasation. Consequently, the tissue viability of ischemic tissue is preserved by polymerized human serum.
- 1 February 2022
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 132 (2) , 489-496
Attenuating ischemia-reperfusion injury with polymerized albumin
Polymerized human serum albumin reduced reperfusion injury and preservers microvascular hemodynamics. Polymerized human serum albumin reduces fluid extravasation and prevents fluid extravasation. Consequently, the tissue viability of ischemic tissue is preserved by polymerized human serum.
- 2 July 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 321 (2) , H400-H411
Increased hemoglobin affinity for oxygen with GBT1118 improves hypoxia tolerance in sickle cell mice
Therapeutic agents that increase the Hb affinity for oxygen (O2) could, in theory, lead to decreased O2 release from Hb and impose a hypoxic risk to tissues. In this study, GBT1118, an allosteric modifier of Hb affinity for O2, was used to assess the impact of increasing Hb affinity for O2 on brain tissue oxygenation, blood pressure, heart rate, O2 delivery, and tolerance to hypoxia in Townes transgenic sickle cell disease (SCD) mice. Brain oxygenation and O2 delivery were studied during normoxia and severe hypoxic challenges. Chronic treatment with GBT1118 increased Hb affinity for O2, reducing the Po2 for 50% HbO2 saturation (P50) in SCD mice from 31 mmHg to 18 mmHg. This treatment significantly reduced anemia, increasing hematocrit by 33%, improved cardiac output (CO), and O2 delivery and extraction. Chronically increasing Hb affinity for O2 with GBT1118 preserved cortical O2 tension during normoxia, improved cortical O2 tension during hypoxia, and increased tolerance to severe hypoxia in SCD mice. Independent of hematological changes induced by chronic treatment, a single dose of GBT1118 significantly improved tolerance to hypoxia, highlighting the benefits of increasing Hb affinity for O2 and consequently reducing sickling of RBCs in blood during hypoxia in SCD. NEW & NOTEWORTHY Chronic pharmacologically increased hemoglobin affinity for oxygen in sickle cell disease mice alleviated hematological consequences of sickle cell disease, increasing RBC half-life, hematocrit, and hemoglobin concentration, while also decreasing reticulocyte count. Additionally, chronically increased hemoglobin affinity for oxygen significantly improved survival as well as cortical tissue oxygenation in sickle cell disease mice during hypoxia, suggesting that oxygen delivery and utilization is improved by increased hemoglobin affinity for oxygen.
- 2 July 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 321 (2) , H400-H411
Increased hemoglobin affinity for oxygen with GBT1118 improves hypoxia tolerance in sickle cell mice
Therapeutic agents that increase the Hb affinity for oxygen (O2) could, in theory, lead to decreased O2 release from Hb and impose a hypoxic risk to tissues. In this study, GBT1118, an allosteric modifier of Hb affinity for O2, was used to assess the impact of increasing Hb affinity for O2 on brain tissue oxygenation, blood pressure, heart rate, O2 delivery, and tolerance to hypoxia in Townes transgenic sickle cell disease (SCD) mice. Brain oxygenation and O2 delivery were studied during normoxia and severe hypoxic challenges. Chronic treatment with GBT1118 increased Hb affinity for O2, reducing the Po2 for 50% HbO2 saturation (P50) in SCD mice from 31 mmHg to 18 mmHg. This treatment significantly reduced anemia, increasing hematocrit by 33%, improved cardiac output (CO), and O2 delivery and extraction. Chronically increasing Hb affinity for O2 with GBT1118 preserved cortical O2 tension during normoxia, improved cortical O2 tension during hypoxia, and increased tolerance to severe hypoxia in SCD mice. Independent of hematological changes induced by chronic treatment, a single dose of GBT1118 significantly improved tolerance to hypoxia, highlighting the benefits of increasing Hb affinity for O2 and consequently reducing sickling of RBCs in blood during hypoxia in SCD. NEW & NOTEWORTHY Chronic pharmacologically increased hemoglobin affinity for oxygen in sickle cell disease mice alleviated hematological consequences of sickle cell disease, increasing RBC half-life, hematocrit, and hemoglobin concentration, while also decreasing reticulocyte count. Additionally, chronically increased hemoglobin affinity for oxygen significantly improved survival as well as cortical tissue oxygenation in sickle cell disease mice during hypoxia, suggesting that oxygen delivery and utilization is improved by increased hemoglobin affinity for oxygen.
- 11 March 2021
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 130 (4) , 1226-1234
High fat high sucrose diet-induced dyslipidemia in guinea pigs
In this study, we show a new animal model for diet-induced disease metabolic disorders without obesity in guinea pigs. Moreover, results suggest a strong relation between liver disease and increased cardiovascular risks.
- 11 March 2021
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 130 (4) , 1226-1234
High fat high sucrose diet-induced dyslipidemia in guinea pigs
In this study, we show a new animal model for diet-induced disease metabolic disorders without obesity in guinea pigs. Moreover, results suggest a strong relation between liver disease and increased cardiovascular risks.
- 1 December 2020
- Published by Elsevier in Free Radical Biology and Medicine
- Vol. 161, 15-22
Control of systemic inflammation through early nitric oxide supplementation with nitric oxide releasing nanoparticles
- 1 December 2020
- Published by Elsevier in Free Radical Biology and Medicine
- Vol. 161, 15-22
Control of systemic inflammation through early nitric oxide supplementation with nitric oxide releasing nanoparticles
- 3 August 2020
- Published by Wiley in The Journal of Physiology
- Vol. 598 (18) , 3817-3818
What determines blood viscosity at the highest city in the world?
- 3 August 2020
- Published by Wiley in The Journal of Physiology
- Vol. 598 (18) , 3817-3818
What determines blood viscosity at the highest city in the world?
- 19 June 2020
- Published by American Society of Hematology in Blood Advances
- Vol. 4 (12) , 2739-2750
Apohemoglobin-haptoglobin complexes attenuate the hypertensive response to low-molecular-weight polymerized hemoglobin
Polymerized hemoglobin (PolyHb) is a promising hemoglobin (Hb)-based oxygen carrier currently undergoing development as a red blood cell substitute. Unfortunately, commercially developed products are composed of low-molecular-weight (LMW) PolyHb molecules, which extravasate, scavenge nitric oxide, and result in vasoconstriction and hypertension. The naturally occurring Hb-scavenging species haptoglobin (Hp), combined with the purified heme-scavenging species apohemoglobin (apoHb), is a potential candidate to alleviate the pressor effect of PolyHb. This study evaluated the protective activity of administering the apoHb-Hp complex to mitigate the vasoactive response induced by the transfusion of LMW PolyHb. Hp binding to PolyHb was characterized in vitro. The effectiveness of apoHb–Hp administration on reducing the vasoconstriction and pressor effects of PolyHb was assessed by measuring systemic and microcirculatory hemodynamics. Transfusion of LMW PolyHb to vehicle control pretreated animals increased mean arterial pressure while decreasing arteriole diameter and functional capillary density. However, transfusion of LMW PolyHb to apoHb–Hp pretreated animals prevented changes in mean arterial pressure, heart rate, arteriole diameter, blood flow, and functional capillary density relative to before transfusion. These results indicate that the increased size of PolyHb after binding to the apoHb-Hp complex may help compartmentalize PolyHb in the vascular space and thus reduce extravasation, nitric oxide scavenging, and toxicity responsible for vasoconstriction and systemic hypertension.
- 19 June 2020
- Published by American Society of Hematology in Blood Advances
- Vol. 4 (12) , 2739-2750
Apohemoglobin-haptoglobin complexes attenuate the hypertensive response to low-molecular-weight polymerized hemoglobin
Polymerized hemoglobin (PolyHb) is a promising hemoglobin (Hb)-based oxygen carrier currently undergoing development as a red blood cell substitute. Unfortunately, commercially developed products are composed of low-molecular-weight (LMW) PolyHb molecules, which extravasate, scavenge nitric oxide, and result in vasoconstriction and hypertension. The naturally occurring Hb-scavenging species haptoglobin (Hp), combined with the purified heme-scavenging species apohemoglobin (apoHb), is a potential candidate to alleviate the pressor effect of PolyHb. This study evaluated the protective activity of administering the apoHb-Hp complex to mitigate the vasoactive response induced by the transfusion of LMW PolyHb. Hp binding to PolyHb was characterized in vitro. The effectiveness of apoHb–Hp administration on reducing the vasoconstriction and pressor effects of PolyHb was assessed by measuring systemic and microcirculatory hemodynamics. Transfusion of LMW PolyHb to vehicle control pretreated animals increased mean arterial pressure while decreasing arteriole diameter and functional capillary density. However, transfusion of LMW PolyHb to apoHb–Hp pretreated animals prevented changes in mean arterial pressure, heart rate, arteriole diameter, blood flow, and functional capillary density relative to before transfusion. These results indicate that the increased size of PolyHb after binding to the apoHb-Hp complex may help compartmentalize PolyHb in the vascular space and thus reduce extravasation, nitric oxide scavenging, and toxicity responsible for vasoconstriction and systemic hypertension.
- 18 June 2020
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 129 (1) , 97-107
Balance between oxygen transport and blood rheology during resuscitation from hemorrhagic shock with polymerized bovine hemoglobin
Large-molecular diameter polymerized bovine hemoglobin avoided vasoconstriction and impairment of cardiac function during resuscitation from hemorrhagic shock that was seen with previous hemoglobin-based O2 carriers by increasing blood viscosity in a concentration-dependent manner. Supplementation of O2-carrying capacity played a smaller role in maintaining cardiac function than increased blood and plasma viscosity.
- 18 June 2020
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 129 (1) , 97-107
Balance between oxygen transport and blood rheology during resuscitation from hemorrhagic shock with polymerized bovine hemoglobin
Large-molecular diameter polymerized bovine hemoglobin avoided vasoconstriction and impairment of cardiac function during resuscitation from hemorrhagic shock that was seen with previous hemoglobin-based O2 carriers by increasing blood viscosity in a concentration-dependent manner. Supplementation of O2-carrying capacity played a smaller role in maintaining cardiac function than increased blood and plasma viscosity.
- 14 April 2020
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 3 (5) , 2976-2985
Polymerized Hemoglobin With Increased Molecular Size Reduces Toxicity in Healthy Guinea Pigs
Hemoglobin (Hb) based oxygen (O2) carriers (HBOCs) have been developed as an alternative to red blood cells (RBCs) for use in transfusion medicine. HBOCs have many benefits over RBCs; however, previous generations of HBOCs failed in clinical trials due to unanticipated cardiotoxicity. These problems likely originated from vasoconstriction, hypertension, oxidative stress, and the presence of low molecular weight (MW) Hb species in the HBOC formulation. Therefore, the objective of this study is to compare the toxicity of small MW PolyHb (SPolyHb) to large MW PolyHb (LPolyHb) in guinea pigs, since they lack the ability to synthesize vitamin C and are more sensitive to oxidative stress relative to other preclinical animal models. Study groups were defined by study solutions, and the control group received 5% human serum albumin (HSA). Solutions were injected as a hypervolemic (topload) infusion of 10% of the blood volume into animals. A set of animals was monitored for 2 hours, in terms of mean arterial pressure, heart rate, and blood gases; and another set of animals was monitored for 24 hours for pharmacokinetics. SPolyHb caused a 50% elevation in MAP from baseline, while LPolyHb caused only a small increase in MAP. Both PolyHbs also increased markers of organ damage, and tissue and systemic inflammation compared to controls. SPolyHb caused significant changes in tissue function and vital organ toxicity markers compared to LPolyHb, specifically markers related to kidney, liver, and lung injury, as well as systemic inflammation and iron transport by the reticuloendothelial system. LPolyHb had a longer half-life than SPolyHb, which correlates with the observations made in the reticuloendothelial and iron transport systems. These studies indicate that the molecular size of PolyHb determines vasoactivity, circulation time, mechanism of elimination, toxicity and inflammation induced by its infusion.
- 14 April 2020
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 3 (5) , 2976-2985
Polymerized Hemoglobin With Increased Molecular Size Reduces Toxicity in Healthy Guinea Pigs
Hemoglobin (Hb) based oxygen (O2) carriers (HBOCs) have been developed as an alternative to red blood cells (RBCs) for use in transfusion medicine. HBOCs have many benefits over RBCs; however, previous generations of HBOCs failed in clinical trials due to unanticipated cardiotoxicity. These problems likely originated from vasoconstriction, hypertension, oxidative stress, and the presence of low molecular weight (MW) Hb species in the HBOC formulation. Therefore, the objective of this study is to compare the toxicity of small MW PolyHb (SPolyHb) to large MW PolyHb (LPolyHb) in guinea pigs, since they lack the ability to synthesize vitamin C and are more sensitive to oxidative stress relative to other preclinical animal models. Study groups were defined by study solutions, and the control group received 5% human serum albumin (HSA). Solutions were injected as a hypervolemic (topload) infusion of 10% of the blood volume into animals. A set of animals was monitored for 2 hours, in terms of mean arterial pressure, heart rate, and blood gases; and another set of animals was monitored for 24 hours for pharmacokinetics. SPolyHb caused a 50% elevation in MAP from baseline, while LPolyHb caused only a small increase in MAP. Both PolyHbs also increased markers of organ damage, and tissue and systemic inflammation compared to controls. SPolyHb caused significant changes in tissue function and vital organ toxicity markers compared to LPolyHb, specifically markers related to kidney, liver, and lung injury, as well as systemic inflammation and iron transport by the reticuloendothelial system. LPolyHb had a longer half-life than SPolyHb, which correlates with the observations made in the reticuloendothelial and iron transport systems. These studies indicate that the molecular size of PolyHb determines vasoactivity, circulation time, mechanism of elimination, toxicity and inflammation induced by its infusion.
- Open Access
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 7, 1-9
Prediction of Recovery From Severe Hemorrhagic Shock Using Logistic Regression
This paper implements logistic regression models (LRMs) and feature selection for creating a predictive model for recovery form hemorrhagic shock (HS) with resuscitation using blood in the multiple experimental rat animal protocols. A total of 61 animals were studied across multiple HS experiments, which encompassed two different HS protocols and two resuscitation protocols using blood stored for short periods using five different techniques. Twenty-seven different systemic hemodynamics, cardiac function, and blood gas parameters were measured in each experiment, of which feature selection deemed only 25% of the them as relevant. The reduced feature set was used to train a final logistic regression model. A final test set accuracy is 84% compared to 74% for a baseline classifier using only MAP and HR measurements. Receiver operating characteristics (ROC) curve analysis and Cohens kappa statistics were also used as measures of performance, with the final reduced model outperforming the model, including all parameters. Our results suggest that LRMs trained with a combination of systemic hemodynamics, cardiac function, and blood gas parameters measured at multiple timepoints during HS can successfully classify HS recovery groups. Our results show the predictive ability of traditional and novel hemodynamic and cardiac function features and their combinations, many of which had not previously been taken into consideration, for monitoring HS. Furthermore, we have devised an effective methodology for feature selection and shown ways in which the performance of such predictive models should be assessed in future studies.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 7, 1-9
Open AccessPrediction of Recovery From Severe Hemorrhagic Shock Using Logistic Regression
This paper implements logistic regression models (LRMs) and feature selection for creating a predictive model for recovery form hemorrhagic shock (HS) with resuscitation using blood in the multiple experimental rat animal protocols. A total of 61 animals were studied across multiple HS experiments, which encompassed two different HS protocols and two resuscitation protocols using blood stored for short periods using five different techniques. Twenty-seven different systemic hemodynamics, cardiac function, and blood gas parameters were measured in each experiment, of which feature selection deemed only 25% of the them as relevant. The reduced feature set was used to train a final logistic regression model. A final test set accuracy is 84% compared to 74% for a baseline classifier using only MAP and HR measurements. Receiver operating characteristics (ROC) curve analysis and Cohens kappa statistics were also used as measures of performance, with the final reduced model outperforming the model, including all parameters. Our results suggest that LRMs trained with a combination of systemic hemodynamics, cardiac function, and blood gas parameters measured at multiple timepoints during HS can successfully classify HS recovery groups. Our results show the predictive ability of traditional and novel hemodynamic and cardiac function features and their combinations, many of which had not previously been taken into consideration, for monitoring HS. Furthermore, we have devised an effective methodology for feature selection and shown ways in which the performance of such predictive models should be assessed in future studies.