Michael Discher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael Discher has a total of 167 co-authors. Here are the top co-authors by number of shared publications:
Clemens Woda
10 shared publicationsHyoungtaek Kim
Radiation Safety Management Division Korea Atomic Energy Research Institute Yuseong Daejeon Republic of Korea
9 shared publicationsJungil Lee
6 shared publicationsCéline Bassinet
4 shared publications- Clemens Woda
HMGU – Helmholtz Zentrum München-German Research Center for Environmental Health, Neuherberg, Germany
3 shared publications Min Chae Kim
3 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 252
Thermoluminescence characterization of smartphone screen glass for emergency retrospective dosimetry across selected phone models
- 5 November 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 252
Open AccessThermoluminescence characterization of smartphone screen glass for emergency retrospective dosimetry across selected phone models
- Open Access
- 18 November 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (11)
Testing different luminescence measurement protocols for display glass as an accident dosimeter
Luminescence dosimetry plays an essential role in retrospective assessments of radiation exposure, particularly in scenarios involving accidental overexposure. This study examines the effectiveness of various luminescence measurement protocols applied to display glass from mobile phones, specifically targeting their potential as accident dosimeters. The efficacy of established protocols, including the pre-bleached thermoluminescence (TL) protocol, the photo-transferred TL (PTTL) protocol, and the thermally assisted optically stimulated luminescence (Ta-OSL) protocols, was evaluated in order to ascertain their performance in accurately reconstructing absorbed doses. An intact Samsung Galaxy S3 smartphone was subjected to gamma irradiation using a Cs-137 source at the Korea Atomic Energy Research Institute (KAERI), thereby simulating a realistic exposure scenario. Following the gamma irradiation, the display glass was chemically pre-treated before being shipped to the Luminescence Laboratory in Salzburg for further measurements and analysis. The luminescence signals were measured using a luminescence reader, with specific stimulation wavelengths (violet, blue and infrared) and readout temperatures tailored to each protocol. The results show that the accuracy of dose reconstruction is slightly different for the different protocols, but in general the results indicate that all protocols (PTTL and the various Ta-OSL protocols) have at least equivalent performance to the established pre-bleached TL protocol. Furthermore, the study compares the signal fading correction methods using a universal or an individual correction approach, which is crucial for correcting the signal loss due to sample storage time since the exposure. This research highlights the potential of mobile phone display glass as a practical and accessible item for retrospective dosimetry, contributing to the field of radiation protection and emergency response. The findings provide a basis for future studies aimed at refining luminescence measurement techniques and extending their application in real-world scenarios.
- 18 November 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (11)
Open AccessTesting different luminescence measurement protocols for display glass as an accident dosimeter
Luminescence dosimetry plays an essential role in retrospective assessments of radiation exposure, particularly in scenarios involving accidental overexposure. This study examines the effectiveness of various luminescence measurement protocols applied to display glass from mobile phones, specifically targeting their potential as accident dosimeters. The efficacy of established protocols, including the pre-bleached thermoluminescence (TL) protocol, the photo-transferred TL (PTTL) protocol, and the thermally assisted optically stimulated luminescence (Ta-OSL) protocols, was evaluated in order to ascertain their performance in accurately reconstructing absorbed doses. An intact Samsung Galaxy S3 smartphone was subjected to gamma irradiation using a Cs-137 source at the Korea Atomic Energy Research Institute (KAERI), thereby simulating a realistic exposure scenario. Following the gamma irradiation, the display glass was chemically pre-treated before being shipped to the Luminescence Laboratory in Salzburg for further measurements and analysis. The luminescence signals were measured using a luminescence reader, with specific stimulation wavelengths (violet, blue and infrared) and readout temperatures tailored to each protocol. The results show that the accuracy of dose reconstruction is slightly different for the different protocols, but in general the results indicate that all protocols (PTTL and the various Ta-OSL protocols) have at least equivalent performance to the established pre-bleached TL protocol. Furthermore, the study compares the signal fading correction methods using a universal or an individual correction approach, which is crucial for correcting the signal loss due to sample storage time since the exposure. This research highlights the potential of mobile phone display glass as a practical and accessible item for retrospective dosimetry, contributing to the field of radiation protection and emergency response. The findings provide a basis for future studies aimed at refining luminescence measurement techniques and extending their application in real-world scenarios.
- Open Access
- 28 October 2025
- Published by Elsevier in Radiation Measurements
- Vol. 190
Evaluating SMD resistors in electronic devices as accident dosimeters using red thermoluminescence
- 28 October 2025
- Published by Elsevier in Radiation Measurements
- Vol. 190
Open AccessEvaluating SMD resistors in electronic devices as accident dosimeters using red thermoluminescence
- Open Access
- 23 April 2024
- Published by Elsevier in Radiation Measurements
- Vol. 174
On the use of new vs. heated sample carriers for luminescence measurements
- 23 April 2024
- Published by Elsevier in Radiation Measurements
- Vol. 174
Open AccessOn the use of new vs. heated sample carriers for luminescence measurements
- Open Access
- 29 March 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 221
Assessment of existing emergency dosimetry protocols for electronic devices - a feasibility study to support emergency response
- 29 March 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 221
Open AccessAssessment of existing emergency dosimetry protocols for electronic devices - a feasibility study to support emergency response
- Open Access
- 30 August 2023
- Published by Elsevier in Radiation Measurements
- Vol. 167
Feasibility study of using earbuds and wireless headphones for retrospective dosimetry
- 30 August 2023
- Published by Elsevier in Radiation Measurements
- Vol. 167
Open AccessFeasibility study of using earbuds and wireless headphones for retrospective dosimetry
- Open Access
- 16 March 2023
- Published by Elsevier in Optical Materials: X
- Vol. 18
A TL study of protective glasses of mobile phones for retrospective dosimetry
- 16 March 2023
- Published by Elsevier in Optical Materials: X
- Vol. 18
Open AccessA TL study of protective glasses of mobile phones for retrospective dosimetry
- Open Access
- 1 February 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 54 (2) , 429-436
Thermally assisted IRSL and VSL measurements of display glass from mobile phones for retrospective dosimetry
- 1 February 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 54 (2) , 429-436
Open AccessThermally assisted IRSL and VSL measurements of display glass from mobile phones for retrospective dosimetry
- Open Access
- 1 January 2022
- Published by Elsevier in Radiation Measurements
- Vol. 150
A small-scale realistic inter-laboratory accident dosimetry comparison using the TL/OSL from mobile phone components
- 1 January 2022
- Published by Elsevier in Radiation Measurements
- Vol. 150
Open AccessA small-scale realistic inter-laboratory accident dosimetry comparison using the TL/OSL from mobile phone components