Graciela M. Escandar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Graciela M. Escandar has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Cesar Olivieri
Departamento de Química Analítica, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531, 2000, Rosario, Argentina; Instituto de Química Rosario (CONICET-UNR), 27 de Febrero 210 Bis, 2000, Rosario, Argentina
8 shared publications Rocío B. Pellegrino Vidal
Instituto de Química Rosario (CONICET-UNR), Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531, 2000 Rosario, Argentina
5 shared publications- Gabriela A. Ibañez
Departamento de Química Analítica, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, and Instituto de Química Rosario (IQUIR), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Suipacha 531, Rosario S2002LRK, Argentina
4 shared publications Juan A. Arancibia
Instituto de Química Rosario (CONICET-UNR), Departamento de Química Analítica, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531, (2000) Rosario, Argentina
4 shared publications- Juan A. Arancibia
Instituto de Química Rosario (CONICET-UNR), Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531 (2000), Rosario, Argentina
4 shared publications Maira D. Carabajal
Instituto de Química Rosario (CONICET-UNR), Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531 (2000), Rosario, Argentina
4 shared publications
Latest Publications
- 18 October 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (7) , 1219-1228
Contribution of multiway calibration to White Analytical Chemistry
In this article, the compatibility between second- and third-order calibration and White Analytical Chemistry (WAC) is exposed and discussed. The WAC concept and the principles on which it is based are briefly presented. Multiway calibration methods, which consist of performing analyte(s) quantification by processing second- or higher-order instrumental data using chemometric models, are analyzed in light of their contribution to the whiteness of an analytical method. Special emphasis is directed towards the chemometric property called “second-order advantage,” which offers the possibility of modeling sample interferences without either needing to remove them nor knowing their identity. With the purpose of illustrating to the analytical community the valuable contribution of multiway calibration to the development of white methodologies, some examples selected from our laboratory are here presented. Graphical Abstract
- 18 October 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (7) , 1219-1228
Contribution of multiway calibration to White Analytical Chemistry
In this article, the compatibility between second- and third-order calibration and White Analytical Chemistry (WAC) is exposed and discussed. The WAC concept and the principles on which it is based are briefly presented. Multiway calibration methods, which consist of performing analyte(s) quantification by processing second- or higher-order instrumental data using chemometric models, are analyzed in light of their contribution to the whiteness of an analytical method. Special emphasis is directed towards the chemometric property called “second-order advantage,” which offers the possibility of modeling sample interferences without either needing to remove them nor knowing their identity. With the purpose of illustrating to the analytical community the valuable contribution of multiway calibration to the development of white methodologies, some examples selected from our laboratory are here presented. Graphical Abstract
- Open Access
- 27 October 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (44) , 39574-39585
A Critical Review on the Development of Optical Sensors for the Determination of Heavy Metals in Water Samples. The Case of Mercury(II) Ion
Recent publications are reviewed concerning the development of sensors for the determination of mercury in drinking water, based on spectroscopic methodologies. A critical analysis is made of the specific details and figures of merit of the developed protocols. Special emphasis is directed to the validation and applicability to real samples in the usual concentration range of mercury, considering the maximum allowed limits in drinking water established by international regulations. It was found that while most publications describe in detail the synthesis, structure, and physicochemical properties of the sensing phases, they do not follow the state of the art in the analytical developments. Recommendations are provided regarding the proper method development and validation, including the setting of the calibration concentration range, the correct estimation of the limits of detection and quantitation, the concentration levels to be set for producing spiked water samples, the number of real samples for adequate validation, the comparison of the developed method with a reference technique, and other analytical features which should be followed.
- 27 October 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (44) , 39574-39585
Open AccessA Critical Review on the Development of Optical Sensors for the Determination of Heavy Metals in Water Samples. The Case of Mercury(II) Ion
Recent publications are reviewed concerning the development of sensors for the determination of mercury in drinking water, based on spectroscopic methodologies. A critical analysis is made of the specific details and figures of merit of the developed protocols. Special emphasis is directed to the validation and applicability to real samples in the usual concentration range of mercury, considering the maximum allowed limits in drinking water established by international regulations. It was found that while most publications describe in detail the synthesis, structure, and physicochemical properties of the sensing phases, they do not follow the state of the art in the analytical developments. Recommendations are provided regarding the proper method development and validation, including the setting of the calibration concentration range, the correct estimation of the limits of detection and quantitation, the concentration levels to be set for producing spiked water samples, the number of real samples for adequate validation, the comparison of the developed method with a reference technique, and other analytical features which should be followed.
- Open Access
Chromatographic Applications in the Multi-Way Calibration Field
In this review, recent advances and applications using multi-way calibration protocols based on the processing of multi-dimensional chromatographic data are discussed. We first describe the various modes in which multi-way chromatographic data sets can be generated, including some important characteristics that should be taken into account for the selection of an adequate data processing model. We then discuss the different manners in which the collected instrumental data can be arranged, and the most usually applied models and algorithms for the decomposition of the data arrays. The latter activity leads to the estimation of surrogate variables (scores), useful for analyte quantitation in the presence of uncalibrated interferences, achieving the second-order advantage. Recent experimental reports based on multi-way liquid and gas chromatographic data are then reviewed. Finally, analytical figures of merit that should always accompany quantitative calibration reports are described.
Open AccessChromatographic Applications in the Multi-Way Calibration Field
In this review, recent advances and applications using multi-way calibration protocols based on the processing of multi-dimensional chromatographic data are discussed. We first describe the various modes in which multi-way chromatographic data sets can be generated, including some important characteristics that should be taken into account for the selection of an adequate data processing model. We then discuss the different manners in which the collected instrumental data can be arranged, and the most usually applied models and algorithms for the decomposition of the data arrays. The latter activity leads to the estimation of surrogate variables (scores), useful for analyte quantitation in the presence of uncalibrated interferences, achieving the second-order advantage. Recent experimental reports based on multi-way liquid and gas chromatographic data are then reviewed. Finally, analytical figures of merit that should always accompany quantitative calibration reports are described.
- 1 February 2019
- Published by Elsevier in Journal of Chromatography A
- Vol. 1587, 2-13
Multi-way chromatographic calibration—A review
- 1 February 2019
- Published by Elsevier in Journal of Chromatography A
- Vol. 1587, 2-13
Multi-way chromatographic calibration—A review
- Open Access
- 20 November 2018
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 3 (11) , 15771-15779
Online Third-Order Liquid Chromatographic Data with Native and Photoinduced Fluorescence Detection for the Quantitation of Organic Pollutants in Environmental Water
Third-order liquid chromatographic data were generated online for the simultaneous quantitation of six organic environmental pollutants. The employed strategy consists in reducing the linear flow rate at the column outlet. A postcolumn UV reactor and a fluorimetric detector allowed to properly record both photoinduced and native excitation–emission fluorescence matrices (EEPIFMs and EEFMs, respectively). The obtained third-order liquid chromatography data were chemometrically processed with the multivariate curve resolution–alternating least-squares model. The sensitivity of the overall analytical method was enhanced by a very simple solid-phase extraction with C18 membranes, to be able to successfully apply it to natural water samples tested as real matrices. Favorable detection limits for the investigated pollutants, ranging from 0.02 to 0.27 ng mL–1, were attained, with relative prediction errors between 2 and 7%. Since the studied samples contain uncalibrated interferents, the applied strategy achieves the second-order advantage. Implications regarding the potential achievement of the third-order advantage are discussed.
- 20 November 2018
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 3 (11) , 15771-15779
Open AccessOnline Third-Order Liquid Chromatographic Data with Native and Photoinduced Fluorescence Detection for the Quantitation of Organic Pollutants in Environmental Water
Third-order liquid chromatographic data were generated online for the simultaneous quantitation of six organic environmental pollutants. The employed strategy consists in reducing the linear flow rate at the column outlet. A postcolumn UV reactor and a fluorimetric detector allowed to properly record both photoinduced and native excitation–emission fluorescence matrices (EEPIFMs and EEFMs, respectively). The obtained third-order liquid chromatography data were chemometrically processed with the multivariate curve resolution–alternating least-squares model. The sensitivity of the overall analytical method was enhanced by a very simple solid-phase extraction with C18 membranes, to be able to successfully apply it to natural water samples tested as real matrices. Favorable detection limits for the investigated pollutants, ranging from 0.02 to 0.27 ng mL–1, were attained, with relative prediction errors between 2 and 7%. Since the studied samples contain uncalibrated interferents, the applied strategy achieves the second-order advantage. Implications regarding the potential achievement of the third-order advantage are discussed.
- Open Access
- 1 December 2017
- Published by Elsevier in Journal of Chromatography A
- Vol. 1527, 61-69
On-line generation of third-order liquid chromatography–excitation-emission fluorescence matrix data. Quantitation of heavy-polycyclic aromatic hydrocarbons
- 1 December 2017
- Published by Elsevier in Journal of Chromatography A
- Vol. 1527, 61-69
Open AccessOn-line generation of third-order liquid chromatography–excitation-emission fluorescence matrix data. Quantitation of heavy-polycyclic aromatic hydrocarbons
- 28 June 2017
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 142 (16) , 2862-2873
A road map for multi-way calibration models
A road map is proposed for the selection of a multi-way calibration model according to the data properties.
- 28 June 2017
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 142 (16) , 2862-2873
A road map for multi-way calibration models
A road map is proposed for the selection of a multi-way calibration model according to the data properties.