Andrija Volkanovski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrija Volkanovski has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Andrej Prošek
Jozef Stefan Institute
3 shared publications Marko Čepin
3 shared publications- Blazhe Gjorgiev
Institute of Energy and Process Engineering, ETH Zurich, Zurich, Switzerland
2 shared publications Duško Kančev
2 shared publications- Andrea Antenucci
Reliability and Risk Engineering Laboratory, Institute of Energy Technology, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
1 shared publication Andrej Prošek
Jozef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana, Slovenia
1 shared publication
Latest Publications
- Open Access
- 1 July 2019
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 51 (4) , 1017-1023
Electric power frequency and nuclear safety - Subsynchronous resonance case study
- 1 July 2019
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 51 (4) , 1017-1023
Open AccessElectric power frequency and nuclear safety - Subsynchronous resonance case study
- 13 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Reliability
- Vol. 69 (2) , 740-753
An FTA Method for the Unavailability of Supply in Gas Networks Supported by Physical Models
This paper presents a fault tree analysis (FTA) method for the unavailability of supply of gas networks. The method is based on the automatic generation of fault trees, which estimate the probability of disruption of the gas delivery from terminals/storages to the demand nodes. Moreover, it allows probabilistic analyses of the availability of gas supply to individual demand nodes and to the overall gas network. To assess the importance of each network component, the risk achievement worth and the risk reduction worth importance measures are utilized. The developed method can identify weakness in the gas network and can guide expansion planning and maintenance scheduling activities. Furthermore, the developed framework is enriched by steady-state analysis of the gas network operations performed using a physical flow/pressure model. The impact of a component failure on the gas supply interruption at different demand nodes is assessed by the physical model in retrospective to the FTA results. The framework is exemplified with reference to the reduced gas network of Great Britain. The results provide insights to support a robust reliability assessment of the gas network. Moreover, the probability mapping of the most important components in the gas network informs optimal strategies for maintenance scheduling as well for prioritizing improvements of the gas network aimed at significant risk reduction. Remarkably, the failure of components identified as most important according to the FTA importance measures may not have significant effects on the gas supply. A discussion on the range of applicability and limitations of the two methodologies is provided.
- 13 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Reliability
- Vol. 69 (2) , 740-753
An FTA Method for the Unavailability of Supply in Gas Networks Supported by Physical Models
This paper presents a fault tree analysis (FTA) method for the unavailability of supply of gas networks. The method is based on the automatic generation of fault trees, which estimate the probability of disruption of the gas delivery from terminals/storages to the demand nodes. Moreover, it allows probabilistic analyses of the availability of gas supply to individual demand nodes and to the overall gas network. To assess the importance of each network component, the risk achievement worth and the risk reduction worth importance measures are utilized. The developed method can identify weakness in the gas network and can guide expansion planning and maintenance scheduling activities. Furthermore, the developed framework is enriched by steady-state analysis of the gas network operations performed using a physical flow/pressure model. The impact of a component failure on the gas supply interruption at different demand nodes is assessed by the physical model in retrospective to the FTA results. The framework is exemplified with reference to the reduced gas network of Great Britain. The results provide insights to support a robust reliability assessment of the gas network. Moreover, the probability mapping of the most important components in the gas network informs optimal strategies for maintenance scheduling as well for prioritizing improvements of the gas network aimed at significant risk reduction. Remarkably, the failure of components identified as most important according to the FTA importance measures may not have significant effects on the gas supply. A discussion on the range of applicability and limitations of the two methodologies is provided.
- Open Access
- 9 July 2018
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2018, 1-21
Analysis of Loss of Essential Power System Reported in Nuclear Power Plants
The essential power supply system is important for the nuclear safety and accident mitigation of the currently operating nuclear power plants. This system provides electrical power to the essential instrumentation and control systems of the nuclear power plant when all alternate current power sources are lost. This event is known as station blackout (SBO) event. Operational events of failure or deficiency of the essential power supply system are analyzed in this paper. The relevant events were searched and identified in four databases of operational events. The report includes events identified in French SAPIDE and German VERA operational events records for the time period 1996 to 2015. The International Atomic Energy Agency (IAEA) IRS and Nuclear Regulatory Commission (NRC) LER operational events databases were screened for relevant events that occurred in the period between 2000 and 2016. In total, 308 relevant events are identified in the SAPIDE, 103 in VERA, 56 in LER, and 15 in IRS operational events database. Classification and in-depth analysis were done on the identified events considering the following predefined categories: the plant status during the event, circumstances, affected equipment, cause of the event (direct and root), and implications of the event on plant safety. Main findings from the evaluation of the events are presented. Observations of the causes resulting in the events and potential actions that can decrease the number and consequences of the events are presented.
- 9 July 2018
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2018, 1-21
Open AccessAnalysis of Loss of Essential Power System Reported in Nuclear Power Plants
The essential power supply system is important for the nuclear safety and accident mitigation of the currently operating nuclear power plants. This system provides electrical power to the essential instrumentation and control systems of the nuclear power plant when all alternate current power sources are lost. This event is known as station blackout (SBO) event. Operational events of failure or deficiency of the essential power supply system are analyzed in this paper. The relevant events were searched and identified in four databases of operational events. The report includes events identified in French SAPIDE and German VERA operational events records for the time period 1996 to 2015. The International Atomic Energy Agency (IAEA) IRS and Nuclear Regulatory Commission (NRC) LER operational events databases were screened for relevant events that occurred in the period between 2000 and 2016. In total, 308 relevant events are identified in the SAPIDE, 103 in VERA, 56 in LER, and 15 in IRS operational events database. Classification and in-depth analysis were done on the identified events considering the following predefined categories: the plant status during the event, circumstances, affected equipment, cause of the event (direct and root), and implications of the event on plant safety. Main findings from the evaluation of the events are presented. Observations of the causes resulting in the events and potential actions that can decrease the number and consequences of the events are presented.
- 1 April 2016
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 148, 11-20
Time-dependent unavailability of equipment in an ageing NPP: Sensitivity study of a developed model
- 1 April 2016
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 148, 11-20
Time-dependent unavailability of equipment in an ageing NPP: Sensitivity study of a developed model
- 3 September 2015
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 1 (4) , 041016
RELAP5/MOD3.3 Analyses for Prevention Strategy of Extended Station Blackout
The purpose of the study was to investigate the application of deterministic safety analysis for a prevention strategy of the extended station blackout (SBO). A method for the assessment of portable pump flow rates for a steam generator (SG) makeup is proposed. The RELAP5/MOD3.3 computer code and input model of a two-loop pressurized water reactor (PWR) is used for analyses, assuming different injection start times, flow rates, and reactor coolant system (RCS) losses. The calculated results show the effectiveness of the proposed extended SBO prevention strategy. The results demonstrate the need for mitigation of the common cause failure (CCF) potential of the on-site and off-site power sources.
- 3 September 2015
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 1 (4) , 041016
RELAP5/MOD3.3 Analyses for Prevention Strategy of Extended Station Blackout
The purpose of the study was to investigate the application of deterministic safety analysis for a prevention strategy of the extended station blackout (SBO). A method for the assessment of portable pump flow rates for a steam generator (SG) makeup is proposed. The RELAP5/MOD3.3 computer code and input model of a two-loop pressurized water reactor (PWR) is used for analyses, assuming different injection start times, flow rates, and reactor coolant system (RCS) losses. The calculated results show the effectiveness of the proposed extended SBO prevention strategy. The results demonstrate the need for mitigation of the common cause failure (CCF) potential of the on-site and off-site power sources.
- 1 March 2015
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 283, 193-201
Impact of component unavailability uncertainty on safety systems unavailability
- 1 March 2015
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 283, 193-201
Impact of component unavailability uncertainty on safety systems unavailability
- Open Access
- 1 January 2015
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2015, 1-9
Delayed Station Blackout Event and Nuclear Safety
The loss of off-site power (LOOP) event occurs when all electrical power to the nuclear power plant from the power grid is lost. Complete failure of both off-site and on-site alternating current (AC) power sources is referred to as a station blackout (SBO). Combined LOOP and SBO events are analyzed in this paper. The analysis is done for different time delays between the LOOP and SBO events. Deterministic safety analysis is utilized for the assessment of the plant parameters for different time delays of the SBO event. Obtained plant parameters are used for the assessment of the probabilities of the functional events in the SBO event tree. The results show that the time delay of the SBO after the LOOP leads to a decrease of the core damage frequency (CDF) from the SBO event tree. The reduction of the CDF depends on the time delay of the SBO after the LOOP event. The results show the importance of the safety systems to operate after the plant shutdown when the decay heat is large. Small changes of the basic events importance measures are identified with the introduction of the delay of the SBO event.
- 1 January 2015
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2015, 1-9
Open AccessDelayed Station Blackout Event and Nuclear Safety
The loss of off-site power (LOOP) event occurs when all electrical power to the nuclear power plant from the power grid is lost. Complete failure of both off-site and on-site alternating current (AC) power sources is referred to as a station blackout (SBO). Combined LOOP and SBO events are analyzed in this paper. The analysis is done for different time delays between the LOOP and SBO events. Deterministic safety analysis is utilized for the assessment of the plant parameters for different time delays of the SBO event. Obtained plant parameters are used for the assessment of the probabilities of the functional events in the SBO event tree. The results show that the time delay of the SBO after the LOOP leads to a decrease of the core damage frequency (CDF) from the SBO event tree. The reduction of the CDF depends on the time delay of the SBO after the LOOP event. The results show the importance of the safety systems to operate after the plant shutdown when the decay heat is large. Small changes of the basic events importance measures are identified with the introduction of the delay of the SBO event.
- 1 September 2014
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 71, 304-312
Alternative off-site power supply improves nuclear power plant safety
- 1 September 2014
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 71, 304-312
Alternative off-site power supply improves nuclear power plant safety
- Open Access
- 1 January 2014
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2014, 1-13
Nuclear Power Plant Maintenance Optimization with Heuristic Algorithm
The test and maintenance activities are conducted in the nuclear power plants in order to prevent or limit failures resulting from the ageing or deterioration. The components and systems are partially or fully unavailable during the maintenance activities. This is especially important for the safety systems and corresponding equipment because they are important contributors to the overall nuclear power plant safety. A novel method for optimization of the maintenance activities in the nuclear power plant considering the plant safety is developed and presented. The objective function of the optimization is the mean value of the selected risk measure. The risk measure is assessed from the minimal cut sets identified in the Probabilistic Safety Assessment. The optimal solution of the objective function is estimated with genetic algorithm. The proposed method is applied on probabilistic safety analysis model of the selected safety system of the reference nuclear power plant. Obtained results show that optimization of maintenance decreases the risk and thus improves the plant safety. The implications of the consideration of different constraints on the obtained results are investigated and presented. The future prospects for the optimization of the maintenance activities in the nuclear power plants with the presented method are discussed.
- 1 January 2014
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2014, 1-13
Open AccessNuclear Power Plant Maintenance Optimization with Heuristic Algorithm
The test and maintenance activities are conducted in the nuclear power plants in order to prevent or limit failures resulting from the ageing or deterioration. The components and systems are partially or fully unavailable during the maintenance activities. This is especially important for the safety systems and corresponding equipment because they are important contributors to the overall nuclear power plant safety. A novel method for optimization of the maintenance activities in the nuclear power plant considering the plant safety is developed and presented. The objective function of the optimization is the mean value of the selected risk measure. The risk measure is assessed from the minimal cut sets identified in the Probabilistic Safety Assessment. The optimal solution of the objective function is estimated with genetic algorithm. The proposed method is applied on probabilistic safety analysis model of the selected safety system of the reference nuclear power plant. Obtained results show that optimization of maintenance decreases the risk and thus improves the plant safety. The implications of the consideration of different constraints on the obtained results are investigated and presented. The future prospects for the optimization of the maintenance activities in the nuclear power plants with the presented method are discussed.
- 23 November 2012
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 255, 16-27
Extension of station blackout coping capability and implications on nuclear safety
- 23 November 2012
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 255, 16-27
Extension of station blackout coping capability and implications on nuclear safety