Juan Manuel Suárez-Grau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Juan Manuel Suárez-Grau has a total of 247 co-authors. Here are the top co-authors by number of shared publications:
Salvador Morales-Conde
Virgen del Rocío University Hospital, Seville, Spain
6 shared publicationsCarolina Rubio Chaves
University Hospital Virgen del Rocio
5 shared publicationsJ. A. Martín Cartes
University Hospital Virgen del Rocio
5 shared publicationsJ. M. Álamo Martínez
University Hospital Virgen del Rocio, Sevilla, Spain
5 shared publications- Miguel Angel Gomez Bravo
Department of Surgery, Hospital Universitario Virgen del Rocío, 41013 Sevilla, Spain
5 shared publications C. Rubio Chaves
Department of Surgery, University Hospital Virgen del Rocío, Avda. Manuel Siurot s/n, 41013, Seville, Spain
4 shared publications
Latest Publications
- Open Access
- 1 May 2024
- Published by Frontiers Media SA in Journal of Abdominal Wall Surgery
- Vol. 3, 12562
Closure of the Peritoneum in Laparoscopic Transabdominal Preperitoneal Inguinal Hernia Repair (TAPP) With Cyanoacrylate Glue in a Microdroplet Device: A Single Surgeon Prospective Comparison vs. Barbed Suture
Purpose: To describe and compare a peritoneal closure technique using cyanoacrylate glue (Glubran 2®, GEM, Cardiolink SL) with a microdroplet device (Glutack®, GEM, Cardiolink SL) in laparoscopic transabdominal preperitoneal repair (TAPP) of inguinal hernia with the routinely used barbed suture peritoneal closure (V-Lock 3.0, Covidien France).Materials and methods: From January to August 2022, 60 patients undergoing TAPP repair for uni- or bilateral inguinal hernia were randomized into one of two groups. One using as mesh fixation and peritoneal closure the Glutack® device with Glubran 2® cyanoacrylate glue (Glu-close group) and the other using mesh fixation with cyanoacrylate and peritoneal closure with V-lock 3.0 (Sut-close group), with a follow-up of 12 months. Demographic variables, operative time, peritoneal closure time, main surgical findings and main intra- and postoperative complications were analyzed prospectively.Results: 63 patients were included with no losses to follow-up. The mean operative time was 34 min (range 58.25) for the glu-close group and 40 (range 64.25) for the sut-close group, with no conversion (0%) for either group. The mean flap closure time was 1.18 min (SD 24 0.19) for the glu-close group and 3.24 min (SD 0.78) for the sut-close group, with statistically significant differences (p < 0.001). The intraoperative complication rate was 0 for the glu-close group and 0 for the sut-close group, with no significant difference. The median hospital stay was 0.8 days (range, 0–1) for both groups. The median duration of follow-up was 12 months and none had hernia recurrence. The postoperative VAS score at the first and second check-up at 1 month and 3 months was 2.83 (SD 1.341) and 0.60 (SD 0.621) in the sut-close group and 1.03 (0.984) and 0.24 (SD 0.435) in the glue-close group, with significant differences (p < 0.001 and p < 0.012).Conclusion: The data demonstrated by the study are that the glue can be used safely to close the peritoneum and that the method provides a small, statistically significant but not clinically relevant reduction in the time to close the peritoneal flap, as well as in postoperative pain after surgery in short and medium term.
- 1 May 2024
- Published by Frontiers Media SA in Journal of Abdominal Wall Surgery
- Vol. 3, 12562
Open AccessClosure of the Peritoneum in Laparoscopic Transabdominal Preperitoneal Inguinal Hernia Repair (TAPP) With Cyanoacrylate Glue in a Microdroplet Device: A Single Surgeon Prospective Comparison vs. Barbed Suture
Purpose: To describe and compare a peritoneal closure technique using cyanoacrylate glue (Glubran 2®, GEM, Cardiolink SL) with a microdroplet device (Glutack®, GEM, Cardiolink SL) in laparoscopic transabdominal preperitoneal repair (TAPP) of inguinal hernia with the routinely used barbed suture peritoneal closure (V-Lock 3.0, Covidien France).Materials and methods: From January to August 2022, 60 patients undergoing TAPP repair for uni- or bilateral inguinal hernia were randomized into one of two groups. One using as mesh fixation and peritoneal closure the Glutack® device with Glubran 2® cyanoacrylate glue (Glu-close group) and the other using mesh fixation with cyanoacrylate and peritoneal closure with V-lock 3.0 (Sut-close group), with a follow-up of 12 months. Demographic variables, operative time, peritoneal closure time, main surgical findings and main intra- and postoperative complications were analyzed prospectively.Results: 63 patients were included with no losses to follow-up. The mean operative time was 34 min (range 58.25) for the glu-close group and 40 (range 64.25) for the sut-close group, with no conversion (0%) for either group. The mean flap closure time was 1.18 min (SD 24 0.19) for the glu-close group and 3.24 min (SD 0.78) for the sut-close group, with statistically significant differences (p < 0.001). The intraoperative complication rate was 0 for the glu-close group and 0 for the sut-close group, with no significant difference. The median hospital stay was 0.8 days (range, 0–1) for both groups. The median duration of follow-up was 12 months and none had hernia recurrence. The postoperative VAS score at the first and second check-up at 1 month and 3 months was 2.83 (SD 1.341) and 0.60 (SD 0.621) in the sut-close group and 1.03 (0.984) and 0.24 (SD 0.435) in the glue-close group, with significant differences (p < 0.001 and p < 0.012).Conclusion: The data demonstrated by the study are that the glue can be used safely to close the peritoneum and that the method provides a small, statistically significant but not clinically relevant reduction in the time to close the peritoneal flap, as well as in postoperative pain after surgery in short and medium term.
- 23 July 2019
- Published by Springer Nature in Hernia
- Vol. 24 (6) , 1245-1251
Could we reduce adhesions to the intra-abdominal mesh in the first week? Experimental study with different methods of fixation
Adhesion formation is a major problem when a mesh is exposed to intraabodminal viscera, with potential severe complications (bowel occlusion, fistulas or abscesses). New methods for preventing adhesions from a polypropylene mesh placed intra-abdominally or to solve difficult situations, such as when the peritoneum cannot be closed during a TAPP repair for an inguinal hernia, are still being seeked. This study mimics in an animal model a situation that can be found in clinical practice during laparoscopic inguinal hernioplasty. A polypropylene mesh could be exposed to the intra-abdominal cavity even when the peritoneum is closed due to different circumstances, with no options to guarantee the prosthetic material of being exposed to the intrabdominal viscera. Different options have been suggested to solve these situations, being proposed in this study to cover the visceral surface of the mesh with an absorbable sponge containing thrombin, fibrinogen, and clotting factors (Tachosil®, Nycomed, Takeda, Osaka, Japan), to assess its use as a barrier to prevent postoperative adhesion formation.
- 23 July 2019
- Published by Springer Nature in Hernia
- Vol. 24 (6) , 1245-1251
Could we reduce adhesions to the intra-abdominal mesh in the first week? Experimental study with different methods of fixation
Adhesion formation is a major problem when a mesh is exposed to intraabodminal viscera, with potential severe complications (bowel occlusion, fistulas or abscesses). New methods for preventing adhesions from a polypropylene mesh placed intra-abdominally or to solve difficult situations, such as when the peritoneum cannot be closed during a TAPP repair for an inguinal hernia, are still being seeked. This study mimics in an animal model a situation that can be found in clinical practice during laparoscopic inguinal hernioplasty. A polypropylene mesh could be exposed to the intra-abdominal cavity even when the peritoneum is closed due to different circumstances, with no options to guarantee the prosthetic material of being exposed to the intrabdominal viscera. Different options have been suggested to solve these situations, being proposed in this study to cover the visceral surface of the mesh with an absorbable sponge containing thrombin, fibrinogen, and clotting factors (Tachosil®, Nycomed, Takeda, Osaka, Japan), to assess its use as a barrier to prevent postoperative adhesion formation.
- 18 September 2018
- Published by Elsevier in Cirugía Española
- Vol. 97 (4) , 233-234
Utilidad del verde de indocianina para la localización del uréter de forma intra-operatoria en cirugía colorrectal compleja
- 18 September 2018
- Published by Elsevier in Cirugía Española
- Vol. 97 (4) , 233-234
Utilidad del verde de indocianina para la localización del uréter de forma intra-operatoria en cirugía colorrectal compleja
- 1 May 2018
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 105 (5) , 1575
Biomechanical Three-Dimensionally Printed Implant Will Be the Future Reconstructive Surgery
- 1 May 2018
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 105 (5) , 1575
Biomechanical Three-Dimensionally Printed Implant Will Be the Future Reconstructive Surgery
- 1 May 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 624, 1031-1040
Unraveling the impact of chronic exposure to metal pollution through human gallstones
- 1 May 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 624, 1031-1040
Unraveling the impact of chronic exposure to metal pollution through human gallstones
- 17 January 2018
- Published by Springer Nature in Surgical Endoscopy
- Vol. 32 (8) , 3502-3508
Laparoscopic intracorporeal rectus aponeuroplasty (LIRA technique): a step forward in minimally invasive abdominal wall reconstruction for ventral hernia repair (LVHR)
Closing the defect (CD) during laparoscopic ventral hernia repair began to be performed in order to decrease seroma, to improve the functionality of the abdominal wall, and to decrease the bulging effect. However, tension at the incision after CD in large defects is related to an increased rate of pain and recurrence. We present the preliminary results of a new technique for medium midline hernias as an alternative to conventional CD.
- 17 January 2018
- Published by Springer Nature in Surgical Endoscopy
- Vol. 32 (8) , 3502-3508
Laparoscopic intracorporeal rectus aponeuroplasty (LIRA technique): a step forward in minimally invasive abdominal wall reconstruction for ventral hernia repair (LVHR)
Closing the defect (CD) during laparoscopic ventral hernia repair began to be performed in order to decrease seroma, to improve the functionality of the abdominal wall, and to decrease the bulging effect. However, tension at the incision after CD in large defects is related to an increased rate of pain and recurrence. We present the preliminary results of a new technique for medium midline hernias as an alternative to conventional CD.
- 1 December 2017
- Published by Elsevier in Journal of Trace Elements in Medicine and Biology
- Vol. 44, 339-348
New insights into the metal partitioning in different microphases of human gallstones
- 1 December 2017
- Published by Elsevier in Journal of Trace Elements in Medicine and Biology
- Vol. 44, 339-348
New insights into the metal partitioning in different microphases of human gallstones
- 25 October 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (12) , 5463
Correction to: Safety and effectiveness of self-adhesive mesh in laparoscopic ventral hernia repair using transabdominal preperitoneal route
The metadata listed the wrong given names and family names.
- 25 October 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (12) , 5463
Correction to: Safety and effectiveness of self-adhesive mesh in laparoscopic ventral hernia repair using transabdominal preperitoneal route
The metadata listed the wrong given names and family names.
- Open Access
- 14 August 2017
- Published by Biomedical Research Network, LLC in Biomedical Journal of Scientific & Technical Research
- Vol. 1 (3)
Laparoscopic Removal of Intra Abdominal Migrated Intrauterine Device Involved in the Omentum
- 14 August 2017
- Published by Biomedical Research Network, LLC in Biomedical Journal of Scientific & Technical Research
- Vol. 1 (3)
Open AccessLaparoscopic Removal of Intra Abdominal Migrated Intrauterine Device Involved in the Omentum