DHDavid. A. Horsley

David. A. Horsley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David. A. Horsley has a total of 152 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Observation of the Effect of Fractional Synchronization on Amplitude and Frequency Stability in Micromechanical Oscillators

    by Parsa Taheri-Tehrani, Martial Defoort, David A. Horsley

    In this paper, we present observations of the amplitude and frequency noise of two self-sustained oscillating modes of a single micromechanical resonator under fractional synchronization. The resonant modes which comprise the self-sustained oscillators have a 3:1 ratio of frequencies. Increasing the amplitude of the low-frequency oscillator increases the range of frequencies over which the oscillations synchronize; inversely, increasing the amplitude of the high-frequency oscillator decreases the synchronization range. We show that by increasing the amplitude of either mode, the white noise in amplitude and frequency of the higher mode will decrease in the synchronized regime. We also show that when synchronized the frequency fluctuations of the higher frequency mode can be reduced by four times in comparison with the fluctuations of the same oscillator operating at the same amplitude when not synchronized. The same amount of reduction is also observed in the amplitude fluctuations of the higher frequency mode. These observations create a path toward exploitation of fractional synchronization for the purposes of noise reduction in both amplitude and frequency of micromechanical oscillators. [2018-0301]


  • Open Access

    Hybrid GMR Sensor Detecting 950 pT/sqrt(Hz) at 1 Hz and Room Temperature

    by André Guedes, Rita Macedo, Gerardo Jaramillo, Susana Cardoso, Paulo P. Freitas, David A. Horsley

    Advances in the magnetic sensing technology have been driven by the increasing demand for the capability of measuring ultrasensitive magnetic fields. Among other emerging applications, the detection of magnetic fields in the picotesla range is crucial for biomedical applications. In this work Picosense reports a millimeter-scale, low-power hybrid magnetoresistive-piezoelectric magnetometer with subnanotesla sensitivity at low frequency. Through an innovative noise-cancelation mechanism, the 1/f noise in the MR sensors is surpassed by the mechanical modulation of the external magnetic fields in the high frequency regime. A modulation efficiency of 13% was obtained enabling a final device’s sensitivity of ~950 pT/Hz1/2 at 1 Hz. This hybrid device proved to be capable of measuring biomagnetic signals generated in the heart in an unshielded environment. This result paves the way for the development of a portable, contactless, low-cost and low-power magnetocardiography device.


  • Synchronization of a micromechanical oscillator in different regimes of electromechanical nonlinearity

    by P. Taheri-Tehrani, M. Defoort, D. A. Horsley

    In this letter, we investigate the dynamics of injection-locking a nonlinear micromechanical oscillator operating in different regimes of electromechanical nonlinearity to an external tone generated by a secondary oscillator. The micromechanical oscillator exhibits a combination of mechanical and electrostatic nonlinearities that were tuned using a bias voltage to adjust the relative importance of third-order and fifth-order stiffness nonlinearities. While it is well-known that third-order stiffness (Duffing) nonlinearity results in a synchronization range that increases with an oscillator's amplitude, little is known about the impact of other nonlinearities. We show that when using Duffing nonlinearity cancellation, higher order nonlinearities dominate, the synchronization range is smaller but has a greater rate-of-increase with oscillation amplitude. When both mechanical stiffness-hardening and electrostatic stiffness-softening nonlinearities are present, the frequency response follows an “s-curve” and, unlike the other conditions, the synchronization range does not increase monotonically with amplitude but instead reaches a minimum when both nonlinearities have similar magnitude. We develop a nonlinear resonator model and show that this model achieves good quantitative prediction of the measured synchronization range in all nonlinear operating regimes studied.


  • Open Access

    Mutual 3:1 subharmonic synchronization in a micromachined silicon disk resonator

    by Parsa Taheri-Tehrani, Andrea Guerrieri, Martial Defoort, Attilio Frangi, David A. Horsley

    We demonstrate synchronization between two intrinsically coupled oscillators that are created from two distinct vibration modes of a single micromachined disk resonator. The modes have a 3:1 subharmonic frequency relationship and cubic, non-dissipative electromechanical coupling between the modes enables their two frequencies to synchronize. Our experimental implementation allows the frequency of the lower frequency oscillator to be independently controlled from that of the higher frequency oscillator, enabling study of the synchronization dynamics. We find close quantitative agreement between the experimental behavior and an analytical coupled-oscillator model as a function of the energy in the two oscillators. We demonstrate that the synchronization range increases when the lower frequency oscillator is strongly driven and when the higher frequency oscillator is weakly driven. This result suggests that synchronization can be applied to the frequency-selective detection of weak signals and other mechanical signal processing functions.


  • Impact of Synchronization in Micromechanical Gyroscopes

    by Martial Defoort, Parsa Taheri-Tehrani, Sarah H. Nitzan, David A. Horsley

    In this paper, we study the occurrence of synchronization between the two degenerate resonance modes of a microdisk resonator gyroscope. Recently, schemes involving the simultaneous actuation of the two vibration modes of the gyroscope have been implemented as a promising new method to increase their performance. However, this strategy might result in synchronization between the two modes, which would maintain frequency mode-matching but also may produce problems, such as degrading stability and sensitivity. Here, we demonstrate for the first time synchronization between the degenerate modes of a microgyroscope and show that synchronization arising from mutual coupling dramatically reduces frequency instability at the cost of increased amplitude instability. We present an alternative synchronization scheme that suppresses this drawback while still taking advantage of a passive frequency mode-match operation.


  • Open Access

    A 170nW CMOS wake-up receiver with −60 dBm sensitivity using AlN high-Q piezoelectric resonators

    by Scott T. Block, Xiaonan Jiang, Brad Harris, Can Cui, Jeronimo Segovia Fernandez, Rajeevan Amirtharajah, David A. Horsley, Hooman Rashtian, Xiaoguang Leo Liu

    A new wake-up receiver (WuRx) designed in 0.13 μm CMOS process is hybrid-integrated with a micro-electromechanical system (MEMS) RF resonator. While only consuming 166 nW of power (18.8 nW for the comparator and 147 nW for periphery), the WuRx is capable of detecting RF signals as weak as -60 dBm. In order to achieve this sensitivity, a passive voltage-boosting network comprised of a high quality factor (high-Q) piezoelectric MEMS resonator is utilized, in place of an inductor, to amplify the received voltages applied to a CMOS rectifier. The output of the rectifier is then applied to a low-power comparator used to set a logical bit that indicates when an RF signal has been detected. The trade-offs in designing the voltage boosting network are explained and an equation for the optimum number of rectifier stages is derived.


  • Flexural Piezoelectric Resonators

    by David Horsley, Yipeng Lu, Ofer Rozen


  • Exploiting nonlinear amplitude-frequency dependence for temperature compensation in silicon micromechanical resonators

    by M. Defoort, P. Taheri-Tehrani, D. A. Horsley

    Resonators used in frequency-reference oscillators must maintain a stable frequency output even when subjected to temperature variations. The traditional solution is to construct the resonator from a material with a low temperature coefficient, such as AT-cut quartz, which can achieve absolute frequency stability on the order of ±25 ppm over commercial temperature ranges. In comparison, Si microresonators suffer from the disadvantage that silicon's temperature coefficient of frequency (TCF) is approximately two orders of magnitude greater than that of AT-cut quartz. In this paper, we present an in situ passive temperature compensation scheme for Si microresonators based on nonlinear amplitude-frequency coupling which reduces the TCF to a level comparable with that of an AT-quartz resonator. The implementation of this passive technique is generic to a variety of Si microresonators and can be applied to a number of frequency control and timing applications.


  • Microcrystalline diamond cylindrical resonators with quality-factor up to 0.5 million

    by Daisuke Saito, Chen Yang, Amir Heidari, Hadi Najar, Liwei Lin, David A. Horsley

    We demonstrate high quality-factor 1.5 mm diameter batch-fabricated microcrystalline diamond cylindrical resonators (CR) with quality-factors limited by thermoelastic damping (TED) and surface loss. Resonators were fabricated 2.6 and 5.3 μm thick in-situ boron-doped microcrystalline diamond films deposited using hot filament chemical vapor deposition. The quality-factor (Q) of as-fabricated CR's was found to increase with the resonator diameter and diamond thickness. Annealing the CRs at 700 °C in a nitrogen atmosphere led to a three-fold increase in Q, a result we attribute to thinning of the diamond layer via reaction with residual O2 in the annealing furnace. Post-anneal Q exceeding 0.5 million (528 000) was measured at the 19 kHz elliptical wineglass modes, producing a ring-down time of 8.9 s. A model for Q versus diamond thickness and resonance frequency is developed including the effects of TED and surface loss. Measured quality factors are shown to agree with the predictions of this model.