Mehmed Ozkan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mehmed Ozkan has a total of 119 co-authors. Here are the top co-authors by number of shared publications:
- Burak Güçlü
Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
6 shared publications Dilek Goksel Duru
Biomedical Engineering Department, Istanbul Arel University, Istanbul, 34537 Turkey
6 shared publicationsAhmet Atasoy
Boğaziçi University
5 shared publications- Dilek Goksel Duru
Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, 34684 Istanbul, Turkey
5 shared publications Erkan Kaplanoglu
Mekatronik Muhendisligi Bolumu, Marmara Univ., Istanbul, Turkey
4 shared publicationsA. Atasoy
Boğaziçi University, Institute of Biomedical Engineering, İstanbul, Turkey
3 shared publications
Latest Publications
- Open Access
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 101051-101065
Force Control of SMA Springs Using RNNs
Shape memory alloys (SMAs), generally composed of nickel-titanium, have unique properties that enable them to transition from the martensite phase to the austenite phase when heated. During this transformation, SMAs can shorten and revert to their original shape, which makes them valuable as actuators. SMAs’ biocompatibility, high power-to-weight ratio, low noise, and ability to generate substantial force position them as essential materials in robotic and biomedical applications. However, their control is complicated by inherent nonlinearity and hysteresis. When cooled in the austenite phase, SMAs elongate and deform, with different phase transformation temperatures observed during heating and cooling due to hysteresis. These complexities highlight the need for advanced control techniques. Artificial intelligence models, particularly recurrent neural networks (RNNs), are well-suited for capturing the intricate relationships within SMA behavior. This study introduces an approach that utilizes RNNs and real-time measurements for force control in SMAs. A compact test setup equipped with sensors collects data on voltage, current, and generated force, enabling the system’s dynamic behavior analysis. RNNs effectively model the nonlinear characteristics of SMA actuators, leveraging their capacity to learn complex temporal relationships from the collected data. This innovative approach aims to enhance the control of SMAs and expand their applications in various fields.
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 101051-101065
Open AccessForce Control of SMA Springs Using RNNs
Shape memory alloys (SMAs), generally composed of nickel-titanium, have unique properties that enable them to transition from the martensite phase to the austenite phase when heated. During this transformation, SMAs can shorten and revert to their original shape, which makes them valuable as actuators. SMAs’ biocompatibility, high power-to-weight ratio, low noise, and ability to generate substantial force position them as essential materials in robotic and biomedical applications. However, their control is complicated by inherent nonlinearity and hysteresis. When cooled in the austenite phase, SMAs elongate and deform, with different phase transformation temperatures observed during heating and cooling due to hysteresis. These complexities highlight the need for advanced control techniques. Artificial intelligence models, particularly recurrent neural networks (RNNs), are well-suited for capturing the intricate relationships within SMA behavior. This study introduces an approach that utilizes RNNs and real-time measurements for force control in SMAs. A compact test setup equipped with sensors collects data on voltage, current, and generated force, enabling the system’s dynamic behavior analysis. RNNs effectively model the nonlinear characteristics of SMA actuators, leveraging their capacity to learn complex temporal relationships from the collected data. This innovative approach aims to enhance the control of SMAs and expand their applications in various fields.
- Open Access
- 1 January 2025
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2025 (1)
Tailored Multibody Tibiofemoral Joint Model for Precision Care
Knee motion involves intricate coordination among various anatomical structures. Effective treatment of knee pathologies requires precise identification of deformities and accurate surgical interventions, which often involve rapid tissue modification based on established knowledge. However, motion disorders are typically detected long after surgery. To address this, a simulation environment is proposed to plan and analyze surgical impacts on knee motion. Comprehensive knee joint modeling is crucial for a successful simulation. Clinically accepted movement procedures based on passive knee motion make tibiofemoral articulation modeling sufficient. Proposed model tibiofemoral articulation, incorporating 15 ligaments, tibial and femoral bones, and cartilages. Ligaments’ tensile, bones’, and cartilages’ contact forces (CFs) define internal force interactions. Anatomical structures, their shapes, positions, and attachment points are identified from MRI, ensuring patient‐specific modeling. Simulation results are compared to cadaver data using passive knee motion. Two rotational and three translational dependent joint motions (JMs) are compared pairwise. The results are highly correlated with the clinical benchmark. Pearson’s correlation show a strong association between experimental and simulated passive knee flexions (PKFs; r > 0.89). The comparison is statistically significant with p < 0.05. Anterior–posterior translation showed the highest correlation ( R 2 = 0.994). The findings indicate that the simulated model closely replicates actual knee responses.
- 1 January 2025
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2025 (1)
Open AccessTailored Multibody Tibiofemoral Joint Model for Precision Care
Knee motion involves intricate coordination among various anatomical structures. Effective treatment of knee pathologies requires precise identification of deformities and accurate surgical interventions, which often involve rapid tissue modification based on established knowledge. However, motion disorders are typically detected long after surgery. To address this, a simulation environment is proposed to plan and analyze surgical impacts on knee motion. Comprehensive knee joint modeling is crucial for a successful simulation. Clinically accepted movement procedures based on passive knee motion make tibiofemoral articulation modeling sufficient. Proposed model tibiofemoral articulation, incorporating 15 ligaments, tibial and femoral bones, and cartilages. Ligaments’ tensile, bones’, and cartilages’ contact forces (CFs) define internal force interactions. Anatomical structures, their shapes, positions, and attachment points are identified from MRI, ensuring patient‐specific modeling. Simulation results are compared to cadaver data using passive knee motion. Two rotational and three translational dependent joint motions (JMs) are compared pairwise. The results are highly correlated with the clinical benchmark. Pearson’s correlation show a strong association between experimental and simulated passive knee flexions (PKFs; r > 0.89). The comparison is statistically significant with p < 0.05. Anterior–posterior translation showed the highest correlation ( R 2 = 0.994). The findings indicate that the simulated model closely replicates actual knee responses.
- 16 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (2) , 428-435
A Macro-Structural Dispersion Characteristic of Brain White Matter and Its Application to Bipolar Disorder
Objective: Our goal is to find distinct characteristics of brain white matter in bipolar disorder, of which the development of diagnostic imaging measures is necessary for early diagnosis and prospective studies. Methods: Given a tractogram dataset which is a dense set of white matter fiber pathways of the whole brain obtained from diffusion magnetic resonance imaging, we propose to compute a global measure for a voxel from the dispersion statistics of a set of fibers which indicates the complexity of the white matter voxel not locally but at macroscopic scales. Results: Our findings demonstrate that macro-structural dispersion information is significant for discrimination of the bipolar patients from the healthy controls, particularly in the frontally associative bundles such as cingulum and inferior occipito-frontal fascicles. Conclusion: The proposed measure is as informative as the local diffusion measures for the detection of changes in the white matter regions. Significance: Our findings show that the proposed measure is a potential diagnostic imaging marker in bipolar disorder and the proposed novel dispersion map of the brain could be used for other neurological applications.
- 16 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (2) , 428-435
A Macro-Structural Dispersion Characteristic of Brain White Matter and Its Application to Bipolar Disorder
Objective: Our goal is to find distinct characteristics of brain white matter in bipolar disorder, of which the development of diagnostic imaging measures is necessary for early diagnosis and prospective studies. Methods: Given a tractogram dataset which is a dense set of white matter fiber pathways of the whole brain obtained from diffusion magnetic resonance imaging, we propose to compute a global measure for a voxel from the dispersion statistics of a set of fibers which indicates the complexity of the white matter voxel not locally but at macroscopic scales. Results: Our findings demonstrate that macro-structural dispersion information is significant for discrimination of the bipolar patients from the healthy controls, particularly in the frontally associative bundles such as cingulum and inferior occipito-frontal fascicles. Conclusion: The proposed measure is as informative as the local diffusion measures for the detection of changes in the white matter regions. Significance: Our findings show that the proposed measure is a potential diagnostic imaging marker in bipolar disorder and the proposed novel dispersion map of the brain could be used for other neurological applications.
- 11 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 27 (5) , 1053-1062
Real-Time Performance of a Tactile Neuroprosthesis on Awake Behaving Rats
With the advancement of electrode and equipment technology, neuroprosthetics have become a promising alternative to partially compensate for the loss of sensorimotor function in amputees and patients with neurological diseases. Cortical neural interfaces are suitable especially for spinal cord injuries and amyotrophic lateral sclerosis. Although considerable success has been achieved in the literature by spike decoding of motor signáis from the human brain, somatosensory feedback is essential for better motor control, interaction with objects, and the embodiment of prosthetic devices. In this study, we present a tactile neuroprosthesis for rats based on intracortical microstimulation (ICMS). The rats wore mechanically-isolated boots covered with tactile sensors while performing a psychophysical detection task. The vibrotactile stimuli were measured by the artificial sensors, and by using a real-time processor, this information was converted to electrical current pulses for ICMS. Some parameters of the real-time processor algorithm were specific to individual rats and were based on psychometric equivalence functions established earlier. Rats could detect the effects of the vibrotactile stimuli better (Le. higher sensitivity Indices) when the tactile neuroprosthesis was switched on compared to the boot only condition during active movement. In other words, the rats could decode the tactile information embedded in ICMS and use that in a behaviorally relevant manner. The presented animal model without peripheral nerve injury or amputation is also a promising tool to test various hardware and software components of neuroprosthetic Systems in general.
- 11 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 27 (5) , 1053-1062
Real-Time Performance of a Tactile Neuroprosthesis on Awake Behaving Rats
With the advancement of electrode and equipment technology, neuroprosthetics have become a promising alternative to partially compensate for the loss of sensorimotor function in amputees and patients with neurological diseases. Cortical neural interfaces are suitable especially for spinal cord injuries and amyotrophic lateral sclerosis. Although considerable success has been achieved in the literature by spike decoding of motor signáis from the human brain, somatosensory feedback is essential for better motor control, interaction with objects, and the embodiment of prosthetic devices. In this study, we present a tactile neuroprosthesis for rats based on intracortical microstimulation (ICMS). The rats wore mechanically-isolated boots covered with tactile sensors while performing a psychophysical detection task. The vibrotactile stimuli were measured by the artificial sensors, and by using a real-time processor, this information was converted to electrical current pulses for ICMS. Some parameters of the real-time processor algorithm were specific to individual rats and were based on psychometric equivalence functions established earlier. Rats could detect the effects of the vibrotactile stimuli better (Le. higher sensitivity Indices) when the tactile neuroprosthesis was switched on compared to the boot only condition during active movement. In other words, the rats could decode the tactile information embedded in ICMS and use that in a behaviorally relevant manner. The presented animal model without peripheral nerve injury or amputation is also a promising tool to test various hardware and software components of neuroprosthetic Systems in general.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 732-736
Biomechanical Design of an Anthropomorphic Prosthetic Hand
The anatomical structure of the hand and its parts; muscles, tendons, bones, and ligaments give the hand its dexterous capabilities in a very efficient way. Studying these structures is important for adapting anthropomorphic features in prosthetic devices. Giving the anthropomorphic features to a prosthetic hand increases the complexity of the mechanical design; therefore, the control of the system. However, we can simplify the mechanical structure of the hand, but still keep the essential functions of the hand with advances in technology. With this motivation, the current study achieves a design for an anthropomorphic hand that imitates a natural hand, taking into account the essential anatomical and functional features.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 732-736
Biomechanical Design of an Anthropomorphic Prosthetic Hand
The anatomical structure of the hand and its parts; muscles, tendons, bones, and ligaments give the hand its dexterous capabilities in a very efficient way. Studying these structures is important for adapting anthropomorphic features in prosthetic devices. Giving the anthropomorphic features to a prosthetic hand increases the complexity of the mechanical design; therefore, the control of the system. However, we can simplify the mechanical structure of the hand, but still keep the essential functions of the hand with advances in technology. With this motivation, the current study achieves a design for an anthropomorphic hand that imitates a natural hand, taking into account the essential anatomical and functional features.
- 6 June 2018
- Published by Springer Nature
- p. 452-463
Evaluation of Sensory Feedback from a Robotic Hand: A Preliminary Study
- 6 June 2018
- Published by Springer Nature
- p. 452-463
Evaluation of Sensory Feedback from a Robotic Hand: A Preliminary Study
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Determination of newborn jaundice level by transcutaneous bilirubin measurement
Diffuse reflectance spectroscopy is a method for obtaining optical properties of skin to determine the biochemical and physiological information. Transcutaneous bilirubin (TcB) measurement is a practice that uses reflectance spectroscopy based on visible spectrum to determine the jaundice level in newborns. It has some advantages over total serum bilirubin (TSB) such as being non-invasive, non-infectious, painless, instantaneous etc. In this study, it is aimed to develop a jaundice level prediction algorithm with artificial neural network (ANN) by using the diffuse reflectance spectra that are obtained by an in-house developed device. For this purpose, TcB and TSB measurements were taken from 314 infants and the algorithm was developed. The predicted jaundice levels were compared with the TSB results in terms of root mean squared error (RMSE) and correlation (r). The developed algorithm gave satisfying results in the sense of accurately predicting the jaundice level. The obtained r value between TSB and TcB is nearly 0.94.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Determination of newborn jaundice level by transcutaneous bilirubin measurement
Diffuse reflectance spectroscopy is a method for obtaining optical properties of skin to determine the biochemical and physiological information. Transcutaneous bilirubin (TcB) measurement is a practice that uses reflectance spectroscopy based on visible spectrum to determine the jaundice level in newborns. It has some advantages over total serum bilirubin (TSB) such as being non-invasive, non-infectious, painless, instantaneous etc. In this study, it is aimed to develop a jaundice level prediction algorithm with artificial neural network (ANN) by using the diffuse reflectance spectra that are obtained by an in-house developed device. For this purpose, TcB and TSB measurements were taken from 314 infants and the algorithm was developed. The predicted jaundice levels were compared with the TSB results in terms of root mean squared error (RMSE) and correlation (r). The developed algorithm gave satisfying results in the sense of accurately predicting the jaundice level. The obtained r value between TSB and TcB is nearly 0.94.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
SMA actuator design considerations
This study is concerned with the correct selection of features that will enable shape memory alloy/materials to be used an efficient, lightweight, silent actuators. Shape memory alloys (SHA) have good potential with their muscle-like working principles. SMA wires and springs are investigated whether they are capable of being used as actuators of a finger on a prosthetic hand.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
SMA actuator design considerations
This study is concerned with the correct selection of features that will enable shape memory alloy/materials to be used an efficient, lightweight, silent actuators. Shape memory alloys (SHA) have good potential with their muscle-like working principles. SMA wires and springs are investigated whether they are capable of being used as actuators of a finger on a prosthetic hand.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Ionic Electroactive Polymer Actuated Prosthetic Finger Design
The proposed work covers an ionic electroactive polymer actuator production for use in a prosthetic finger design. The best mechanical design will be possible if it considers anatomical features of the real finger/hand structure. A number of different finger movements for different purposes are formed by the antagonistic pairs of muscles. Ionic electroactive polymer actuators are intended to be used instead of intrinsic muscles, which enable precise movement of the hand beyond the force required for movement due to their low power consumption, low noise, high power/mass ratio.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Ionic Electroactive Polymer Actuated Prosthetic Finger Design
The proposed work covers an ionic electroactive polymer actuator production for use in a prosthetic finger design. The best mechanical design will be possible if it considers anatomical features of the real finger/hand structure. A number of different finger movements for different purposes are formed by the antagonistic pairs of muscles. Ionic electroactive polymer actuators are intended to be used instead of intrinsic muscles, which enable precise movement of the hand beyond the force required for movement due to their low power consumption, low noise, high power/mass ratio.