Devendra Kumar Dubey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Devendra Kumar Dubey has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Deepak Pardasani
VERTOX Laboratory, Defence R&D Establishment, Gwalior, India
34 shared publicationsVijay Tak
Vertox Laboratory, Defence Research and Development Establishment, Jhansi Road, Gwalior 474002, India
22 shared publicationsPankaj K. Kanaujia
Vertox Laboratory, Defence Research and Development Establishment, Gwalior 474002, India
13 shared publicationsMeehir Palit
VERTOX Laboratory , Defence Research and Development Establishment , Jhansi Road , Gwalior 474002 , Madhya Pradesh , India
11 shared publications- Avik Mazumder
Vertox Laboratory, Defence Research and Development Establishment, Jhansi Road, Gwalior 474002, India
10 shared publications Ajay Kumar Purohit
VERTOX Laboratory, Defence R&D Establishment, Gwalior, India
7 shared publications
Latest Publications
- 11 November 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (48) , 5839-5845
Gas chromatography-mass spectrometric identification of cyanide using a nucleophilic substitution based derivatization with S-phenyl benzenethiosulfonate
A novel, simple and efficient analytical method for GC-MS based identification of cyanide has been developed using a single step nucleophilic substitution based derivatization of cyanide in aqueous medium. The nucleophilic substitution reaction of cyanide with S-phenyl benzenethiosulfonate results in the formation of phenyl thiocyanate as a cyanide derivative and it was found that the relative response of the resultant cyanide derivative was much higher than that of the cyanide derivatives resulting from disulfide based derivatizing agents. The sample preparation protocol for the identification of cyanide in aqueous samples was also optimized with the new derivatizing agent. Derivatization followed by liquid–liquid extraction was employed for the preparation of aqueous samples containing cyanide salts. The resultant samples were subjected to GC-MS analysis for the identification of the cyanide derivative. Under optimized conditions, the detection and quantification limits for cyanide aqueous samples were found to be 0.075 μg mL−1 and 0.25 μg mL−1 respectively. The calibration curve had a linear relationship with y = 0.086x − 0.076 and r2 = 0.997 for the working range of 0.25 μg mL−1 to 50 μg mL−1. The intraday RSDs were between 2.24 and 8.17%, and the interday RSDs were between 2.22 and 12.85%. The method can also be successfully employed for the identification of hydrogen cyanide in aqueous medium. The applicability of the present method was demonstrated by analysing a real sample from apple seed extraction.
- 11 November 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (48) , 5839-5845
Gas chromatography-mass spectrometric identification of cyanide using a nucleophilic substitution based derivatization with S-phenyl benzenethiosulfonate
A novel, simple and efficient analytical method for GC-MS based identification of cyanide has been developed using a single step nucleophilic substitution based derivatization of cyanide in aqueous medium. The nucleophilic substitution reaction of cyanide with S-phenyl benzenethiosulfonate results in the formation of phenyl thiocyanate as a cyanide derivative and it was found that the relative response of the resultant cyanide derivative was much higher than that of the cyanide derivatives resulting from disulfide based derivatizing agents. The sample preparation protocol for the identification of cyanide in aqueous samples was also optimized with the new derivatizing agent. Derivatization followed by liquid–liquid extraction was employed for the preparation of aqueous samples containing cyanide salts. The resultant samples were subjected to GC-MS analysis for the identification of the cyanide derivative. Under optimized conditions, the detection and quantification limits for cyanide aqueous samples were found to be 0.075 μg mL−1 and 0.25 μg mL−1 respectively. The calibration curve had a linear relationship with y = 0.086x − 0.076 and r2 = 0.997 for the working range of 0.25 μg mL−1 to 50 μg mL−1. The intraday RSDs were between 2.24 and 8.17%, and the interday RSDs were between 2.22 and 12.85%. The method can also be successfully employed for the identification of hydrogen cyanide in aqueous medium. The applicability of the present method was demonstrated by analysing a real sample from apple seed extraction.
- 9 April 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (17) , 16027-16039
Triazine-Based Covalent Organic Framework: A Promising Sorbent for Efficient Elimination of the Hydrocarbon Backgrounds of Organic Sample for GC–MS and 1H NMR Analysis of Chemical Weapons Convention Related Compounds
The strict monitoring and precise measurements of Chemical Warfare Agents (CWAs) in environmental and other complex samples with high accuracy have great practical significance from the forensic and Chemical Weapons Convention (CWC) verification point of view. Therefore, this study was aimed to develop an efficient extraction and enrichment method for identification and quantification of toxic agents, especially with high sensitivity and multi-detection ability in complex samples. It is the first study on solid phase extraction (SPE) of CWAs and their related compounds from hydrocarbon background using covalent triazine-based frameworks (CTFs). This nitrogen rich CTFs sorbent has shown an excellent SPE performance towards sample clean-up by selective elimination of hydrocarbon backgrounds and enrich the CWC related analytes in comparison with the conventional and other reported methods. The best enrichment of the analytes was found with the washing solvent 1 mL n-hexane and the extraction solvent 1 mL dichloromethane (DCM). Under the optimized conditions, the SPE method had good linearity in concentration range of 0.050−10.0 μg mL−1 for organophosphorus esters, 0.040−20.0 μg mL−1 for nerve agents and 0.200−20.0 μg mL−1 for mustards with correlation coefficients (r2) between 0.9867–0.9998 for all analytes. Limits of detection (LOD) (S:N=3:1) in SIM mode was found to be in the range of 0.015−0.050 μg mL−1 for organophosphorus esters, 0.010−0.030 μg mL−1 for nerve agents and 0.050−0.100 μg mL−1 for blister agents. Limit of quantification (LOQ) (S:N=10:1) were found in the range of 0.050 – 0.200 μg mL−1 for organophosphorus esters, 0.040 – 0.100 μg mL−1 for nerve agents and 0.180 – 0.350 μg mL−1 for blister agents in SIM mode. The recoveries of all analytes ranged from 87−100 % with the relative standard deviations (RSDs) ranging 1− 8 %. This method was also successfully applied for the sample preparation of 1H-NMR analysis of sulfur and nitrogen mustards in presence of hydrocarbon backgrounds. Therefore, this SPE method provides single sample preparation for both NMR and GC-MS analysis.
- 9 April 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (17) , 16027-16039
Triazine-Based Covalent Organic Framework: A Promising Sorbent for Efficient Elimination of the Hydrocarbon Backgrounds of Organic Sample for GC–MS and 1H NMR Analysis of Chemical Weapons Convention Related Compounds
The strict monitoring and precise measurements of Chemical Warfare Agents (CWAs) in environmental and other complex samples with high accuracy have great practical significance from the forensic and Chemical Weapons Convention (CWC) verification point of view. Therefore, this study was aimed to develop an efficient extraction and enrichment method for identification and quantification of toxic agents, especially with high sensitivity and multi-detection ability in complex samples. It is the first study on solid phase extraction (SPE) of CWAs and their related compounds from hydrocarbon background using covalent triazine-based frameworks (CTFs). This nitrogen rich CTFs sorbent has shown an excellent SPE performance towards sample clean-up by selective elimination of hydrocarbon backgrounds and enrich the CWC related analytes in comparison with the conventional and other reported methods. The best enrichment of the analytes was found with the washing solvent 1 mL n-hexane and the extraction solvent 1 mL dichloromethane (DCM). Under the optimized conditions, the SPE method had good linearity in concentration range of 0.050−10.0 μg mL−1 for organophosphorus esters, 0.040−20.0 μg mL−1 for nerve agents and 0.200−20.0 μg mL−1 for mustards with correlation coefficients (r2) between 0.9867–0.9998 for all analytes. Limits of detection (LOD) (S:N=3:1) in SIM mode was found to be in the range of 0.015−0.050 μg mL−1 for organophosphorus esters, 0.010−0.030 μg mL−1 for nerve agents and 0.050−0.100 μg mL−1 for blister agents. Limit of quantification (LOQ) (S:N=10:1) were found in the range of 0.050 – 0.200 μg mL−1 for organophosphorus esters, 0.040 – 0.100 μg mL−1 for nerve agents and 0.180 – 0.350 μg mL−1 for blister agents in SIM mode. The recoveries of all analytes ranged from 87−100 % with the relative standard deviations (RSDs) ranging 1− 8 %. This method was also successfully applied for the sample preparation of 1H-NMR analysis of sulfur and nitrogen mustards in presence of hydrocarbon backgrounds. Therefore, this SPE method provides single sample preparation for both NMR and GC-MS analysis.
- 28 March 2019
- Published by Springer Nature in Archives of Toxicology
- Vol. 93 (6) , 1473-1484
Adductomics: a promising tool for the verification of chemical warfare agents’ exposures in biological samples
Humans are constantly exposed to a wide range of reactive and toxic chemicals from the different sources in everyday life. Identification of the exposed chemical helps in the detection and understanding the exposure associated adverse health effects. Covalent adducts of proteins and DNA formed after xenobiotics exposure may serve as readily measurable indicators of these exposures. Measuring the exposed chemicals with focus on adducts resulting from the nucleophilic interactions with blood proteins is useful in the development of diagnostic markers. Particularly, the most abundant proteins such as albumin and hemoglobin acts as dominant scavengers for many reactive chemicals in blood and can serve as excellent diagnostic candidates to determine the type of chemical exposure. This review focuses on the potential application of an adductomics approach for the screening of bimolecular adducts of chemical warfare agents (CWAs). Recent incidents of CWAs use in Syria, Malaysia, and the UK illustrate the continuing threat of chemical warfare agents in the modern world. Detection of CWAs and their metabolites in blood or in other body fluids of victims depends on immediate access to victims. Concentrations of intact CWAs in body fluids of surviving victims may decline rapidly within a few days. Certain CWAs, particularly nerve agents and vesicants, form covalent bonds with certain amino acids to form CWA-protein adducts. Proteins that are abundant in the blood, including albumin and hemoglobin, may carry these adducts longer after the original exposure. We searched MEDLINE and ISI Web of Science databases using the key terms “adductomics” “adducts of CWAs,” “CWAs adducts detection in the biological samples,” “protein adducts of CWAs,” alone and in combination with the keywords “detection” “intoxication” “exposure” “adverse effects” and “toxicity.” We also included non-peer-reviewed sources such as text books, relevant newspaper reports, and applicable Internet resources. We screened bibliographies of identified articles for additional relevant studies including non-indexed reports. These searches produced 1931 citations of which only relevant and nonduplicate citations were considered for this review. The analysis of biomedical samples has several purposes including detecting and identifying the type of chemical agent exposed, understanding the biological mechanism, assists in giving adequate treatment, determining the cause of death and providing evidence in a court of justice for forensic investigations. Rapid advances in the mass spectrometry to acquire high-quality data with greater resolution enabled the analysis of protein and DNA adducts of xenobiotics including CWAs and place the rapidly advancing ‘adductomics’ next to the other “-omics” technologies. Adductomics can serve as a powerful bioanalytical tool for the verification of CWAs exposure. This review mostly describes the protein adducts for nerve agents and vesicants, outlines the procedures for measuring adducts, and suggests the evolving (or future) use of adducts in the detection and verification of CWAs.
- 28 March 2019
- Published by Springer Nature in Archives of Toxicology
- Vol. 93 (6) , 1473-1484
Adductomics: a promising tool for the verification of chemical warfare agents’ exposures in biological samples
Humans are constantly exposed to a wide range of reactive and toxic chemicals from the different sources in everyday life. Identification of the exposed chemical helps in the detection and understanding the exposure associated adverse health effects. Covalent adducts of proteins and DNA formed after xenobiotics exposure may serve as readily measurable indicators of these exposures. Measuring the exposed chemicals with focus on adducts resulting from the nucleophilic interactions with blood proteins is useful in the development of diagnostic markers. Particularly, the most abundant proteins such as albumin and hemoglobin acts as dominant scavengers for many reactive chemicals in blood and can serve as excellent diagnostic candidates to determine the type of chemical exposure. This review focuses on the potential application of an adductomics approach for the screening of bimolecular adducts of chemical warfare agents (CWAs). Recent incidents of CWAs use in Syria, Malaysia, and the UK illustrate the continuing threat of chemical warfare agents in the modern world. Detection of CWAs and their metabolites in blood or in other body fluids of victims depends on immediate access to victims. Concentrations of intact CWAs in body fluids of surviving victims may decline rapidly within a few days. Certain CWAs, particularly nerve agents and vesicants, form covalent bonds with certain amino acids to form CWA-protein adducts. Proteins that are abundant in the blood, including albumin and hemoglobin, may carry these adducts longer after the original exposure. We searched MEDLINE and ISI Web of Science databases using the key terms “adductomics” “adducts of CWAs,” “CWAs adducts detection in the biological samples,” “protein adducts of CWAs,” alone and in combination with the keywords “detection” “intoxication” “exposure” “adverse effects” and “toxicity.” We also included non-peer-reviewed sources such as text books, relevant newspaper reports, and applicable Internet resources. We screened bibliographies of identified articles for additional relevant studies including non-indexed reports. These searches produced 1931 citations of which only relevant and nonduplicate citations were considered for this review. The analysis of biomedical samples has several purposes including detecting and identifying the type of chemical agent exposed, understanding the biological mechanism, assists in giving adequate treatment, determining the cause of death and providing evidence in a court of justice for forensic investigations. Rapid advances in the mass spectrometry to acquire high-quality data with greater resolution enabled the analysis of protein and DNA adducts of xenobiotics including CWAs and place the rapidly advancing ‘adductomics’ next to the other “-omics” technologies. Adductomics can serve as a powerful bioanalytical tool for the verification of CWAs exposure. This review mostly describes the protein adducts for nerve agents and vesicants, outlines the procedures for measuring adducts, and suggests the evolving (or future) use of adducts in the detection and verification of CWAs.
- 16 June 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (14) , 8295-8299
Efficient Extraction of Sulfur and Nitrogen Mustards from Nonpolar Matrix and an Investigation on Their Sorption Behavior on Silica
Extraction of vesicant class of chemical warfare agents (CWAs) such as sulfur mustard and nitrogen mustards from the environmental matrices is of prime importance; from forensic & verification view point of the Chemical Weapons Convention (CWC). For extraction of Convention Related Compounds from nonpolar organic medium, commercially available silica cartridges are used extensively. But silica cartridges exhibit limited efficiency towards vesicant classes of compounds. It is expected that sulfur mustard being nonpolar do not retain sufficiently on silica surface and nitrogen mustards (being basic) are strongly adsorbed on acidic silica surface, resulting in their poor recoveries. Contrary to expected higher recovery of sulfur mustard over nitrogen mustards, it was observed that the recovery of sulfur mustard was lower than that of nitrogen mustards with silica based sorbent. The reason for this typical behavior of these agents on silica was investigated. This study was aimed to develop an analytical method for efficient extraction and enrichment of sulfur & nitrogen mustards from hydrophobic matrices. In this work, polymeric sorbent was synthesized with polar methacrylic acid (MAA) as monomer and ethylene glycol dimethacrylate (EGDMA) as crosslinker and used for solid phase extraction (SPE) of sulfur mustard and nitrogen mustards. The extraction efficiency of the polymeric sorbent was optimized and compared with that of silica cartridges. Both classes of analytes were recovered in good amounts from the polymeric sorbent compared to silica. The extraction parameters were optimized for the proposed method which included extraction solvent ethyl acetate and washing solvent 1 mL n-hexane. The recoveries of the analytes ranged from 75-87 % with relative standard deviations (RSDs) lower than 9 %. The limit of detection (LOD) was found to be in the range of 0.075-0.150 μg mL-1 and limit of quantification (LOQ) was > 0.25 μg mL-1. Linear dynamic range of optimized method was found to be 0.50 – 20 μg mL-1 (r2 = 0.9994) for sulfur mustard and 0.25 – 20 μg mL-1 (r2 = 0.9897–0.9987) for nitrogen mustards respectively.
- 16 June 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (14) , 8295-8299
Efficient Extraction of Sulfur and Nitrogen Mustards from Nonpolar Matrix and an Investigation on Their Sorption Behavior on Silica
Extraction of vesicant class of chemical warfare agents (CWAs) such as sulfur mustard and nitrogen mustards from the environmental matrices is of prime importance; from forensic & verification view point of the Chemical Weapons Convention (CWC). For extraction of Convention Related Compounds from nonpolar organic medium, commercially available silica cartridges are used extensively. But silica cartridges exhibit limited efficiency towards vesicant classes of compounds. It is expected that sulfur mustard being nonpolar do not retain sufficiently on silica surface and nitrogen mustards (being basic) are strongly adsorbed on acidic silica surface, resulting in their poor recoveries. Contrary to expected higher recovery of sulfur mustard over nitrogen mustards, it was observed that the recovery of sulfur mustard was lower than that of nitrogen mustards with silica based sorbent. The reason for this typical behavior of these agents on silica was investigated. This study was aimed to develop an analytical method for efficient extraction and enrichment of sulfur & nitrogen mustards from hydrophobic matrices. In this work, polymeric sorbent was synthesized with polar methacrylic acid (MAA) as monomer and ethylene glycol dimethacrylate (EGDMA) as crosslinker and used for solid phase extraction (SPE) of sulfur mustard and nitrogen mustards. The extraction efficiency of the polymeric sorbent was optimized and compared with that of silica cartridges. Both classes of analytes were recovered in good amounts from the polymeric sorbent compared to silica. The extraction parameters were optimized for the proposed method which included extraction solvent ethyl acetate and washing solvent 1 mL n-hexane. The recoveries of the analytes ranged from 75-87 % with relative standard deviations (RSDs) lower than 9 %. The limit of detection (LOD) was found to be in the range of 0.075-0.150 μg mL-1 and limit of quantification (LOQ) was > 0.25 μg mL-1. Linear dynamic range of optimized method was found to be 0.50 – 20 μg mL-1 (r2 = 0.9994) for sulfur mustard and 0.25 – 20 μg mL-1 (r2 = 0.9897–0.9987) for nitrogen mustards respectively.
- 26 April 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (11) , 7025-7032
Polymeric Sorbent with Controlled Surface Polarity: An Alternate for Solid-Phase Extraction of Nerve Agents and Their Markers from Organic Matrix
Extraction and identification of lethal nerve agents and their markers in complex organic background have prime im-portance from the forensic & verification view point of the Chemical Weapons Convention (CWC). Liquid-liquid extraction with acetonitrile and commercially available solid phase silica cartridges are extensively used for this purpose. Silica car-tridges exhibit limited applicability for relatively polar analytes and acetonitrile extraction shows limited efficacy towards relatively nonpolar analytes. The present study describes synthesis of polymeric sorbents with tunable surface polarity and their application as a solid-phase extraction (SPE) materials against nerve agents and their polar as well as nonpolar markers from nonpolar organic matrices. In comparison with the acetonitrile extraction and commercial silica cartridges the new sorbent showed better extraction efficiency towards analytes of varying polarity. The extraction parameters were optimized for the proposed method which included the ethyl acetate as extraction solvent¬¬¬ and n-hexane as washing solvent. Under optimized conditions method linearity ranged from 0.10 – 10 μg mL-1 (r2 = 0.9327 – 0.9988) for organophosphorus esters and 0.05 – 20 μg mL-1 (r2 = 0.9976 – 0.9991) for nerve agents. Limits of detection (S:N=3:1) in SIM mode were found in the range of 0.03 – 0.075 μg mL-1 for organophosphorus esters and 0.015 – 0.025 μg mL-1 for nerve agents. Limit of quan-tification (S:N=10:1) were found in the range of 0.100 – 0.25 μg mL-1 for organophosphorus esters and 0.05 – 0.100 μg mL-1 for nerve agents in SIM mode. The recoveries of nerve agents and their markers ranged from 90% to 98% and 75.0% to 95.0% respectively. The repeatability and reproducibility (with relative standard deviations (RSDs) %) for organophosphorus esters were found in the range of 1.35 – 8.61% and 2.30 – 9.25% respectively. For nerve agents, the repeatability range from 1.00 to 7.75% and reproducibility were found in the range of 2.17 – 6.90%.
- 26 April 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (11) , 7025-7032
Polymeric Sorbent with Controlled Surface Polarity: An Alternate for Solid-Phase Extraction of Nerve Agents and Their Markers from Organic Matrix
Extraction and identification of lethal nerve agents and their markers in complex organic background have prime im-portance from the forensic & verification view point of the Chemical Weapons Convention (CWC). Liquid-liquid extraction with acetonitrile and commercially available solid phase silica cartridges are extensively used for this purpose. Silica car-tridges exhibit limited applicability for relatively polar analytes and acetonitrile extraction shows limited efficacy towards relatively nonpolar analytes. The present study describes synthesis of polymeric sorbents with tunable surface polarity and their application as a solid-phase extraction (SPE) materials against nerve agents and their polar as well as nonpolar markers from nonpolar organic matrices. In comparison with the acetonitrile extraction and commercial silica cartridges the new sorbent showed better extraction efficiency towards analytes of varying polarity. The extraction parameters were optimized for the proposed method which included the ethyl acetate as extraction solvent¬¬¬ and n-hexane as washing solvent. Under optimized conditions method linearity ranged from 0.10 – 10 μg mL-1 (r2 = 0.9327 – 0.9988) for organophosphorus esters and 0.05 – 20 μg mL-1 (r2 = 0.9976 – 0.9991) for nerve agents. Limits of detection (S:N=3:1) in SIM mode were found in the range of 0.03 – 0.075 μg mL-1 for organophosphorus esters and 0.015 – 0.025 μg mL-1 for nerve agents. Limit of quan-tification (S:N=10:1) were found in the range of 0.100 – 0.25 μg mL-1 for organophosphorus esters and 0.05 – 0.100 μg mL-1 for nerve agents in SIM mode. The recoveries of nerve agents and their markers ranged from 90% to 98% and 75.0% to 95.0% respectively. The repeatability and reproducibility (with relative standard deviations (RSDs) %) for organophosphorus esters were found in the range of 1.35 – 8.61% and 2.30 – 9.25% respectively. For nerve agents, the repeatability range from 1.00 to 7.75% and reproducibility were found in the range of 2.17 – 6.90%.
- 1 January 2018
- Published by Elsevier in European Polymer Journal
- Vol. 98, 105-115
A simplistic designing of molecularly imprinted polymers for derivative of nerve agents marker using 31P{1H}NMR
- 1 January 2018
- Published by Elsevier in European Polymer Journal
- Vol. 98, 105-115
A simplistic designing of molecularly imprinted polymers for derivative of nerve agents marker using 31P{1H}NMR
- 1 February 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1434, 39-49
Magnetic hydrophilic–lipophilic balance sorbent for efficient extraction of chemical warfare agents from water samples
- 1 February 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1434, 39-49
Magnetic hydrophilic–lipophilic balance sorbent for efficient extraction of chemical warfare agents from water samples
- 1 December 2015
- Published by Elsevier in Journal of Chromatography A
- Vol. 1426, 16-23
A glass capillary based microfluidic electromembrane extraction of basic degradation products of nitrogen mustard and VX from water
- 1 December 2015
- Published by Elsevier in Journal of Chromatography A
- Vol. 1426, 16-23
A glass capillary based microfluidic electromembrane extraction of basic degradation products of nitrogen mustard and VX from water